Platelet Agitator Operation Manual

Similar documents
Undercounter Refrigerator Operation Manual

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Freezer Operation Manual

Undercounter Refrigerator / Freezer

Platelet Storage. i.series Horizon Series

Platelet Storage. i.series Horizon Series

MEDICAL DEVICES. Refrigerators HELMER HIGH QUALITY REFRIGERATORS

Ultra-Low Freezer Operation Manual

Automatic Cell Washing System Operation Manual

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Refrigerators. Upright Blood Bank. i.series Horizon Series

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

General safety precautions English

General safety precautions English

Freezers. Laboratory & Plasma. i.series Horizon Series

Pass-Thru Refrigerators. Pharmacy & Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Laboratory & Pharmacy Refrigerators

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

Undercounter Refrigerators and Freezers. Laboratory/Pharmacy Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series Scientific Series

ZP2 Series Operation Manual

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

O-Two Self-Study Guide. eseries Transport Ventilator Control and Function Keys and Connections

General safety precautions English

Operator s Manual. IP-100 Immersion Probe Cooler

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

ec Preheater User Manual

KFP-CF Series Operation Manual

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

General safety precautions English

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

MDF-U333 MDF-U537 MDF-U537D

Important Safety Notice

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Refrigerated Incubator Model and Operating Instructions

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

GigaCore RPSU. Redundant power supply for GigaCore 14R and 16Xt. Quick Start Guide. V2.0.0 Rev1. English

Operating Instructions

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

1.1 Setup Installation

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

ULTRA LOW TEMPERATURE FREEZER. User Manual

TTT Digital Incubator

Silent TS2 Nr /

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

OPERATOR S MODEL MPC-21L MPC-222 MULTIPURPOSE PASS-THRU HOLDING CABINET. Read instructions before operating the appliance

General safety precautions English

Hi-Temp Bath Installation and Operation Manual

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

OPERATOR S MODEL HCN-5 HHC-136 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

Installation Instructions Built-In Wine Coolers, Beverage Centers

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Corning LSE 6L Digital Water Bath

QUICK START GUIDE. Modular 3000 Series. 115 V / 60 Hz

INSTALLATION INSTRUCTIONS ESS 7.0

CabLite Luminous Auto Light Control Installation Manual

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

2kW Wall Mounted Electric Fire Complete with flat glass front panel. Installation Instructions & Operating Manual

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

General safety precautions English

Owner s Manual & Safety Instructions

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

SILENT compact /

Alarm System SECURE AS 302

MD-MINI Dry Bath. Instruction Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT-900. HCT-900 User Guide _C

Operation Manual (Version 1.5.1)

- Data Brochure Addendum

KM300 Carbon Monoxide Detection System Installation Manual

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Pasto Sous vide water bath

OneControl Unity Board M Series

700G Series. Pressure Gauge. Safety Information

Operation Manual. (Version 1.5.1)

MDF-U7586SC MDF-U5586SC. Operating Instructions. Ultra-Low Temperature Freezer MDF-U7586SC

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Installation Requirements for Models:

Operating Instructions

Cisco TelePresence MCU 4200 Series safety and compliance information

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Microplate Heat Sealer, Variable Temperature

OPERATING MANUAL MODEL NO MODEL NO AND MODEL NO MODEL NO

CR24 INSTALLATION INSTRUCTIONS

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

i.c³ User Guide for Compartmental Access Refrigerators

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Infrared Thermometer. Getting Started

OPERATOR S MANUAL. BASIC PROJECT CENTERS Some instructions and drawings may not apply to your specific unit. SAFETY SERVICE PARTS CAPACITIES

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

WSK300 Multifunction Wall Control

Introduction... 1 System Overview... 1 System Diagram... 2

SAVE THESE INSTRUCTIONS

Owner s Manual Super-Slim Four-Way Cassette

Transcription:

Platelet gitator Operation Manual i.series and Horizon Series Model Group i.series Horizon Series Countertop PF15i, PF48i, PF96i (Version ) PF15h, PF48h, PF96h (Version ) Floor PF396i (Version ) - HELMER SCIENTIFIC 14400 ergen oulevard Noblesville, IN 46060 US PH +1.317.773.9073 FX +1.317.773.9082 US and Canada 800.743.5637 360092-1/P ISO 13485:2003 CERTIFIED

Document History Revision Date CO Supersession Revision Description M 28 JUN 2013* 8414 Supersedes,, C, D, E, F, G, Revised layout for ease of navigation and locating information. H, I, J, K, L N 23 DEC 2013* 8965 N supersedes M dded 100 V information. dded caution note for remote alarm interface. Revised clearance statement. Revised section I for consistency with existing manuals. O 31 JN 2014* 9113 O supersedes N Changed voltage for remote alarm contacts. P 22 MY 2014* 9497 P supersedes O dded information to environmental/application specifications from technical audit. Revised specifications for remote alarm contacts. * Date submitted for Change Order review. ctual release date may vary. 360092-1/P i

Contents Section I: General Information... 4 1 bout this Manual... 4 1.1 Intended udience...................................................................... 4 1.2 Model References...4 1.3 Copyright and Trademark...4 2 Safety... 4 2.1 Safety Definitions...4 2.2 Product Labels...5 2.3 voiding Injury...5 3 General Recommendations................................................... 6 3.1 Intended Use...6 3.2 General Use...6 3.3 Initial Loading...6 4 Specifications... 6 5 Compliance... 7 5.1 Regulatory Compliance...7 5.2 WEEE Compliance...7 6 Installation... 8 6.1 Location Requirements...8 6.1.1 Placement...8 7 Maintenance Schedule... 9 Section II: i.series Models......................................... 10 8 Operation... 10 8.1 Initial Start Up...10 8.2 Configure the Platelet gitator for Use in an i.series Incubator (Optional)...10 8.3 Motion larm...10 8.3.1 Enable and Disable Motion larm...10 8.3.2 Set larm Delay...11 8.3.3 Set larm Volume...11 8.4 Enable or Disable Motion...12 8.4.1 Stand-lone Platelet gitators...12 8.4.2 Platelet gitators Installed in i.series Platelet Incubators...12 9 Load the gitator... 13 10 Components... 14 10.1 Front...14 10.2 Left Side...15 10.3 Right Side...16 10.4 Rear...17 10.5 ottom...18 360092-1/P ii

Section III: Horizon Series Models... 19 11 Operation... 19 11.1 Initial Start Up...19 11.2 Enable and Disable Motion...19 11.2.1 Stand-lone Platelet gitators...19 11.2.2 Platelet gitators Installed in Horizon Series Platelet Incubators...19 12 Load the gitator... 20 13 Components... 21 13.1 Front...21 13.2 Left Side...21 13.3 Rear...22 13.4 ottom...22 360092-1/P iii

Section I: General Information General Information 1 bout this Manual 1.1 Intended udience This manual is intended for use by end users of the platelet agitator and authorized service technicians. 1.2 Model References Generic references are used throughout this manual to group models that contain similar features. For example, PF48 models refers to all models of that size (PF48i, PF48h). This manual covers all platelet agitators, which may be identified singly, by their size, or by their respective Series. 1.3 Copyright and Trademark Helmer, i.series, Horizon Series, and Rel.i are registered trademarks or trademarks of Helmer, Inc. in the United States of merica. Copyright 2014 Helmer, Inc. ll other trademarks and registered trademarks are the property of their respective owners. Helmer, Inc., doing business as (D) Helmer Scientific and Helmer. 2 Safety The operator or technician performing maintenance or service on Helmer Scientific products must (a) inspect the product for abnormal wear and damage, (b) choose a repair procedure which will not endanger his/her safety, the safety of others, the product, or the safe operation of the product, and (c) fully inspect and test the product to ensure the maintenance or service has been performed properly. 2.1 Safety Definitions The following general safety alerts appear with all safety statements within this manual. Read and abide by the safety statement that accompanies the safety alert symbol. WRNING The safety statement that follows this safety alert symbol indicates a hazardous situation which, if not avoided, could result in serious injury. CUTION The safety statement that follows this safety alert symbol indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE The safety statement that follows this safety alert symbol indicates a situation which, if not avoided, could result in damage to the product or stored inventory. 360092-1/P 4

General Information 2.2 Product Labels The following general safety and information alerts appear on the product to identify potential hazards to the operator or service technician. Caution: Risk of damage Caution: Unlock all casters to equipment or danger to operator Caution: Hot surface Earth / ground terminal Caution: Shock/electrical hazard Protective earth / ground terminal 2.3 voiding Injury Review safety instructions before installing, using, or maintaining the equipment. efore moving unit, remove contents from the drawers. Do not open multiple drawers at the same time. efore moving unit, disconnect the C power cord and secure the cord. When moving unit, use assistance from a second person. Never physically restrict any moving component. void removing electrical service panels and access panels unless so instructed. Keep hands away from pinch points when agitation motion is enabled. void sharp edges when working inside the electrical compartment. Ensure biological materials are stored at recommended temperatures determined by standards, literature, or good laboratory practices. Proceed with caution when adding and removing samples from the platelet agitator. Use supplied power cord only. Using the equipment in a manner not specified by Helmer Scientific may impair the protection provided by the equipment. Decontaminate parts prior to sending for service or repair. Contact Helmer Scientific or your distributor for decontamination instructions and a Return uthorization Number. Ensure biological materials are stored safely, in accordance with all applicable organizational, regulatory, and legal requirements. The platelet agitator is not considered to be a storage cabinet for flammable or hazardous materials. 360092-1/P 5

3 General Recommendations General Information 3.1 Intended Use Helmer platelet agitators are intended to provide the continuous gentle agitation conditions required for the storage of platelet products. The devices are intended to be operated by personnel who have procedures in place for meeting FD,, EU or any other applicable regulations for the processing and storage of platelet products. 3.2 General Use llow platelet agitator to come to room temperature before switching power on. During initial startup, motion alarm may sound if the motion is disabled. 3.3 Initial Loading fter platelet agitator reaches room temperature, begin storing product. 4 Specifications PF15 PF48 PF96 PF396i Physical Height 12.50 (318 mm) 15.25 (387 mm) 15.25 (387 mm) 62 (1575 mm) Width (1, 2) 13.00 (330 mm) 17.50 (445 mm) 33.00 (838 mm) 37 (940 mm) Depth 9.25 (235 mm) 14.50 (368 mm) 14.50 (368 mm) 27 (686 mm) Weight 26.5 lbs (12 kg) 51.0 lbs (23 kg) 82.0 lbs (37 kg) 250.0 lbs (114 kg) Electrical Input Voltage and Frequency Voltage Tolerance 100 V, 50/60 Hz / 115 V, 60 Hz 230 V, 50 Hz / 230 V, 60 Hz ±10% 0.5 (100 V, 115 V, quantity 1) Fuses (3) 0.3 (230 V, quantity 2) Power 0.4 (100 V, 115 V) Consumption (4) 0.25 (230 V) Power Source (5) gitation Speed (cycles / minute) Remote larm Capacity Control and Monitoring larms Varies (refer to product specification label) 72 (100 V / 115 V) 60 (230 V, 50 Hz) 72 (230 V, 60 Hz) 115 V, 60 Hz 230 V, 50 Hz 230 V, 60 Hz 6.3 (115 V, quantity 1) 5.0 (230 V, quantity 2) 3.0 (115 V) 2.0 (230 V) 60 (115 V) 60 (230 V, 50 Hz) 72 (230 V, 60 Hz) i.series: 0.5 at 30 V (RMS); 1.0 at 24 V (DC) Horizon Series: 0.25 at 30 V (RMS); 0.25 at 60 V (DC) Motion 360092-1/P 6

General Information Environmental pplication PF15 PF48 PF96 PF396i Indoor use only ltitude (maximum): 2000 m mbient temperature range: 5 C to 35 C Relative humidity (maximum for ambient temperature): 80% for temperatures up to 31 C, decreasing linearly to 50% at 40 C Overvoltage category: II Pollution degree: 2 Mains supply voltage: ±10% of nominal voltage (1) dd 0.5 (13 mm) to the width for PF15i, PF48i, and PF96i platelet agitators to accommodate the alarm buzzer. (2) dd 1.5 (38 mm) to the width for PF15i, PF48i, and PF96i platelet agitators to accommodate the storage frame when agitation motion is enabled. (3) Fuses are 5 mm x 20 mm, time lag (Type T). (4) Power consumption is measured in full-load mperes. (5) Product specification label is located on the bottom of the platelet agitator (PF15) or the rear of the platelet agitator (PF48, PF96, PF396i). CUTION The interface on the remote alarm monitoring system is intended for connection to the end user s central alarm system(s) that uses normally-open or normally-closed dry contacts. If an external power supply exceeding 30 V (RMS) or 60 V (DC) is connected to the remote alarm monitoring system s circuit, the remote alarm will not function properly; may be damaged; or may result in injury to the user. 360092-1/P 7

5 Compliance General Information 5.1 Regulatory Compliance This device complies with the requirements of directive 93/42/EEC concerning Medical Devices, as amended by 2007/47/EC. Sound level is less than 70 d(). EC REP Emergo Europe Molenstraat 15 2513 H The Hague, Netherlands PF396i platelet agitator is not CE compliant. 5.2 WEEE Compliance The WEEE (waste electrical and electronic equipment) symbol (right) indicates compliance with European Union Directive WEEE 2002/96/EC and applicable provisions. The directive sets requirements for the labeling and disposal of certain products in affected countries. When disposing of this product in countries affected by this directive: Do not dispose of this product as unsorted municipal waste. Collect this product separately. Use the collection and return systems available locally. 6 Installation For more information on the return, recovery, or recycling of this product, contact your local distributor. 6.1 Location Requirements Has a sturdy, level surface. Has a grounded outlet meeting the electrical requirements listed on the product specification label. Is clear of direct sunlight, high temperature sources, and heating and air conditioning vents. Minimum 0.5 (13 mm) in front and behind. Minimum 1 (25 mm) on left and right sides (when installed in a corresponding Helmer platelet incubator). Minimum 2 (50 mm) on left and right sides (when installed in a stand-alone configuration). Meets limits specified for ambient temperature and relative humidity. power cord is supplied to configure the platelet agitator for stand-alone use. 360092-1/P 8

6.1.1 Placement General Information WRNING To prevent tipping, ensure the casters are unlocked (PF396i). 1 Ensure all casters are unlocked (PF396i). 2 Place platelet agitator on study surface or roll platelet agitator into place and lock casters (PF396i). 3 Ensure platelet agitator is level. NOTICE Countertop models: When lifting platelet agitator, lift using the ends of the base. If the base is not accessible, lift using the ends of the storage frame. PF396i: When moving the platelet agitator, push using the sides of the base, not the front or back. 7 Maintenance Schedule Maintenance tasks should be completed according to the following schedule. Refer to the service manual for more detail on the various tasks. These are recommended minimum requirements. Regulations for your organization or physical conditions at your organization may require maintenance items to be performed more frequently, or only by designated service personnel. Task Test the motion alarm. Clean the fan (except PF396i). Clean the vents in the base (PF396i). Check the backup battery for the motion alarm system after an extended power failure and change it if necessary, or change the battery if it has been in service for one year. Check moving parts for wear. Clean and lubricate moving parts. Replace moving parts if worn. Clean the exterior of the platelet agitator. Frequency Quarterly nnually s Needed (i.series) (i.series) Clean the fan on a quarterly basis. During a power failure (when the motion alarm is enabled), the backup battery provides power to the motion alarm. If the backup battery is not functioning, the motion alarm will not be activated. If the backup battery does not provide power to the alarm system during the motion alarm test, replace the battery. i.series: If battery has been in service for one year, replace battery. 360092-1/P 9

Section II: i.series Models i.series Models 8 Operation 8.1 Initial Start Up 1 Switch the agitation ON/OFF switch OFF. 2 Plug the power cord into a grounded outlet that meets the electrical requirements on the product specification label. 3 Connect the backup battery for the motion alarm. 4 Switch C ON/OFF switch ON. 8.2 Configure the Platelet gitator for Use in an i.series Incubator (Optional) Helmer i.series platelet agitators may be installed in a stand-alone configuration, or in a Helmer i.series platelet incubator. When installed in a Helmer platelet incubator, motion information is transmitted from the platelet agitator to the platelet incubator through a data cable. Refer to the platelet agitator service manual for information regarding the installation of a platelet agitator in a platelet incubator. 8.3 Motion larm When platelet agitator motion stops the motion alarm is activated. The alarm condition is communicated as follows: Red alarm LED illuminates. udible alarm buzzer sounds. Through a dry (no voltage) connection to an external monitoring device (if connected). Through a 9 V connection to an external monitoring device (if connected). Through a data cable to the i.series countertop platelet incubator (if platelet agitator is installed in an i.series platelet incubator). 8.3.1 Enable and Disable Motion larm Motion alarm switch (circled). Switch the motion alarm ON/OFF switch ON. Switch the motion alarm ON/OFF switch OFF. NOTICE If motion stops while the motion alarm is switched off, communication of the alarm (visual, audible, and signals to external devices) is suppressed. Stand-lone Platelet gitators Enable the motion alarm when using the platelet agitator. Disable the motion alarm when not using the platelet agitator. Lack of motion triggers the alarm. Platelet gitators Installed in i.series Platelet Incubators Disable the motion alarm when installing the platelet agitator in a Helmer i.series platelet incubator. 360092-1/P 10

i.series Models Motion information is transmitted through the data cable to the platelet incubator, even when the motion alarm is disabled. The platelet incubator interprets the motion information and generates its own motion alarm, based on its own alarm delay period. If the motion alarm is not disabled on the platelet agitator, the motion alarms on both devices will sound. 8.3.2 Set larm Delay The duration of time between when agitation stops and when the alarm sounds is the alarm delay. The alarm delay is set using the alarm delay control. larm delay control (circled). The default motion alarm delay is set at the halfway point (approximately 4 to 5 minutes). To change the motion alarm delay, use a small flat-head screwdriver. Rotate the control to the left (counterclockwise) to shorten the motion alarm delay. Rotate the control to the right (clockwise) to extend the motion alarm delay. Do not set the alarm delay to 0 minutes. Default alarm delay is set at the halfway point (approximately 4 to 5 minutes). Maximum alarm delay is 8 minutes. 8.3.3 Set larm Volume larm volume control (circled). The motion alarm has three settings (low, medium, high). Default setting is medium (switch is in the middle position). Slide the motion alarm switch to the appropriate position for the desired volume level. 360092-1/P 11

8.4 Enable or Disable Motion i.series Models gitation switch. 8.4.1 Stand-lone Platelet gitators Start gitation: 1 Switch the agitation ON/OFF switch ON. 2 Switch the motion alarm switch ON/OFF switch ON. Stop gitation: 1 Switch the motion alarm switch ON/OFF switch OFF. 2 Switch the agitation ON/OFF switch OFF. 8.4.2 Platelet gitators Installed in i.series Platelet Incubators The door switch on Helmer platelet incubators controls power to the installed platelet agitator(s). When the platelet incubator doors(s) is opened, power to the installed platelet agitator(s) is interrupted and agitation motion is paused. When the platelet incubator door(s) is closed, agitation motion is resumed. Ensure the platelet agitator motion alarm switch ON/OFF is switched OFF. Start gitation: 1 Open the platelet incubator door(s). gitation motion stops. 2 Load items into the platelet agitator. 3 Close the platelet incubator door(s). gitation motion resumes. For a platelet agitator installed in a stand-alone configuration, switching the agitation ON/OFF switch ON will start the agitation motion. Stop gitation: 1 Open the platelet incubator door(s). The platelet agitator motion stops. 2 Remove items from the platelet agitator. 3 Close the platelet incubator door(s). gitation motion will resume if the agitation ON/OFF switch is not switched OFF. For a platelet agitator installed in a stand-alone configuration, switching the agitation ON/OFF switch OFF will stop the agitation motion. 360092-1/P 12

9 Load the gitator i.series Models PF48i agitator with platelet bags (shown in a Helmer PC900i incubator). Model Capacity Random ags pheresis ags PF15i 15 5-10 PF48i 48 16 PF96i 96 32 PF396i 396 132 CUTION When opening drawer, grasp handle (not label holder). Open one drawer at a time. Open the drawer to be loaded and lay the platelet bags flat. void stacking bags. Maintain enough space around each bag for air circulation. For thicker bags, remove drawers. Place the tubing under or around the bag. 360092-1/P 13

10 Components i.series Models 10.1 Front C D E F G Front features (multiple models shown). Label C D E F G Description Storage frame Drawer (not included on PF15i) ase gitation switch Motion alarm lamp Motion alarm switch larm buzzer 360092-1/P 14

10.2 Left Side i.series Models C D E F Left side features (PF15i shown). Label C D E F Description Power connector Fuse Data cable port Fan larm volume control larm delay control 360092-1/P 15

10.3 Right Side i.series Models C D E Right side features (multiple models shown). Label C D E Description ccess hole larm buzzer Data cable port larm volume control larm delay control 360092-1/P 16

10.4 Rear i.series Models C D E F G Rear features (multiple models shown). Label C D E F G Description Product specification label Power connector Vent Fuse Data cable port larm volume control larm delay control 360092-1/P 17

10.5 ottom i.series Models ottom features (multiple models shown). Label Description Product specification label Fan 360092-1/P 18

Section III: Horizon Series Models Horizon Series Models 11 Operation 11.1 Initial Start Up 1 Switch the agitation ON/OFF switch OFF. 2 Plug the power cord into a grounded outlet that meets the electrical requirements on the product specification label. 3 Switch C ON/OFF switch ON. 11.2 Enable and Disable Motion gitation switch. 11.2.1 Stand-lone Platelet gitators Start gitation: 1 Switch the agitation ON/OFF switch ON. 2 Switch the motion alarm switch ON/OFF switch ON. Stop gitation: 1 Switch the motion alarm switch ON/OFF switch OFF. 2 Switch the agitation ON/OFF switch OFF. 11.2.2 Platelet gitators Installed in Horizon Series Platelet Incubators Start gitation: 1 Open the platelet incubator door(s). 2 Switch the agitation ON/OFF switch ON. 3 Close the platelet incubator door(s). gitation motion starts. For a platelet agitator installed in a platelet incubator, if the agitation ON/OFF switch is switched ON, closing the platelet incubator door(s) will start the agitation. Stop gitation: 1 Open the platelet incubator door(s). 2 Switch the agitation ON/OFF switch OFF. 3 Close the platelet incubator door(s). gitation motion stops. For a platelet agitator installed in a platelet incubator, if the agitation ON/OFF switch is switched ON, opening the platelet incubator door(s) will stop the agitation motion. 360092-1/P 19

12 Load the gitator Horizon Series Models PF48h agitator with platelet bags (shown in a Helmer PC900h incubator). Model Capacity Random ags pheresis ags PF15h 15 5-10 PF48h 48 16 PF96h 96 32 CUTION When opening drawer, grasp handle (not label holder). Open one drawer at a time. Open the drawer to be loaded and lay the platelet bags flat. void stacking bags. Maintain enough space around each bag for air circulation. For thicker bags, remove drawers. Place the tubing under or around the bag. 360092-1/P 20

13 Components Horizon Series Models 13.1 Front D C Front features (multiple models shown). Label C D Description Storage frame Drawer (not included on PF15h) ase gitation switch 13.2 Left Side C Left side features (PF15h shown). Label C Description Power connector Fuse Fan 360092-1/P 21

13.3 Rear Horizon Series Models Rear features (multiple models shown). C Label C Description Product Specification label Power connector Fuse 13.4 ottom ottom features (multiple models shown). Label Description Product Specification label Fan END OF MNUL 360092-1/P 22

HELMER SCIENTIFIC 14400 ergen oulevard Noblesville, IN 46060 US PH +1.317.773.9073 FX +1.317.773.9082 www.helmerinc.com