VIBRA-series: VIBRA, VIBRA +

Similar documents
Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Nardalert S3 TM Non-Ionizing Radiation Monitor

CMCS Ltd. Precision monitoring for the construction industry to help manage risk

D3 Wireless temperature alarm & monitoring system family. tek-troniks

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

FLX380-30x FlexTester OTDR

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

ACCESS Master MT9085 Series. Product Introduction

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

Laboratory Refrigerator/Deep Freezer TC 802

HOBO U14 Data Logger User Manual

Cold chain monitoring technologies. Facility monitoring

DATAssure. Laboratory wireless alarm & monitoring system

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

The Next Generation of Dynamo Subwoofer Systems

PRODUCT CATALOGUE INFRA Field Monitoring System

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

EasyLog Data Logger Series

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Outdoor Temperature Sensor

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Specification for On-Line UPS Battery Monitoring and Data Management System

SMS GSM Alarm Messenger

Chromatographic Air circulated Refrigerator, two-door TC 603

RAE Systems Systems. User Presentation. October Protection Through Detection

ADVANCED TEXCEL MONITOR

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

OLIP SYSTEMS INC. OLIP Intelligent Wireless Condition Monitoring System

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Refrigerator/Freezer Thermometer

CAN unit for Analog Sensors

Panel Mounted Fault Annunciator Series

THE BELLMAN & SYMFON WAY Visit technical training

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

ALTAIR 5X Multigas Detector Product Specification

Snifter. User Manual. Distributor

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics

Typical applications include the vibration detector. Detection of vibrations and shocks

M700-Series Multifunction OTDR

More Precision. thermometer // Non-contact IR temperature sensors

Refrigerator/Freezer Thermometer

OPTISENS TUR 2000 Technical Datasheet

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

VD8. mode VD8. Digital Compact Vacuum Meters Data Loggers

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

EXPANDABLE SMART HOME SECURITY KIT

Omniguard 4: Features

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

IMR IX176 Portable Gas Detector User Manual

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Dew point set DS 400

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

YOUR PARTNER IN FIRE & GAS DETECTION

WS3650IT. Pro Family weather station with T/H sensor, pluviometer, anemometer & PC connection.

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

SoundEar 3. Measure, monitor and manage noise in hospitals.

Continuous, real-time detection, alarming and analysis of partial discharge events

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment

Trident User s Manual

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Microtherm Heat Stress WBGT

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

More Precision. indusensor // Linear inductive displacement sensors

Frequently asked questions: Intelligent Transmitter Series

Introduction. OM-THA2

165 Supplements and Amendments to the MSR 165 User Manual

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

HRX Technical Manual. Version 1.2

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Product data sheet Palas Fidas 200 S

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

HI-PE HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics

For the Safety of Your

Operations Manual TS400. Test Station for G450/G460 Gas Detector

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

Mark 25 Ultrapure Water Conductivity Analyzer

EL-USB-1-LCD Temperature Data Logger with LCD

Panel Mounted Fault Annunciator Series

AV6416 OTDR. Product Overview: Main Features:

ANEMOMETER 4403-RF-BAT

EL-USB-1-LCD Temperature Data Logger with LCD

THX-DL Data Logger USER & INSTALLATION MANUAL V

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Our Extended Personal Electronic Dosimeter (PED) Family

Di-440 The Modular Analyser

Company Introduction. Logtech! to aim at best of vibration & noise field

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

Operating instructions for moisture analyzers - UX 3001 (UX 3011, UX 3031, UX 3081) series

MGC Dock User s Manual

Transcription:

DATASHEET VIBRA-series (VIB.00100/..120/..130) VIBRA-series: VIBRA, VIBRA + Profound VIBRA-series Vibrations from pile driving, construction, road or rail traffic, demolition work and blasting can create nuisance or cause damage to buildings and sensitive equipment. These vibrations are accurately quantified with a system of the Profound VIBRAseries. The VIBRA s robust aluminium housing is IP65 watertight. The system is easily portable, lightweight and battery-operated which allows for up to 4 weeks of continuous and unmanned operation. Depending on the chosen model VIBRA or VIBRA +, the system complies with national and international standards and is according to DIN 45669-1:2010. The specific characteristics of each model are further outlined in the VIBRA features overview. Setting up the system on site is easy: attach the 3-dimensional sensor to the structure to be monitored, switch on the system and start measuring. While measuring the VIBRA displays date, time, time interval and the current peak vibration values including frequency in all 3 directions. In advance an alarm level can be set. Peak values including dominant frequencies, are directly stored in memory. For full interpretation measurement signals are transferred via USB to a computer for further analysis. The VIBRA pc software automatically generates tables and graphs of peak values and signals for use in reports. The data can also be easily exported as a csv-file. The VIBRA + can be set up for wireless automatic data transfer including sms alerts via the integrated 3G modem. Data can also be continuously uploaded to any FTP server for real-time online monitoring. As an alternative Profound offers a turnkey online monitoring service. Technical specifications VIBRA-series Velocity (PPV), frequency In x, y, z-direction per time interval and acceleration (PPA) Displacement (VIBRA + only) In x, y, z-direction per time interval Sensor type 3-channel geophone Geophone correction Digital IR filter Velocity range 0 100 mm/s Resolution display 0.01 mm/s Resolution AD-converter 0.001 mm/s (24 bits ADC) Frequency range and accuracy DIN 45669-1:2010-09 or SBR part A, B 2002 Storage capacity 4 MB. Fixed or ring memory incl. buffer Storage interval 1, 2, 5, 10, 20, 30, 60 s Data save level Adjustable between 0.01-100.00 mm/s (or always) Alarm level Adjustable between 0.01-100.00 mm/s (or none) Data retention 10 years (minimum) at 25 C Clock stability Within 5 minutes/year at 25 C Temperature range - 20 C to + 60 C (operating) Housing Robust hard anodized aluminium case Dimensions (l x w x h) 216 x 160 x 50 mm 2 kg Display 4 Lines; display backlight; anti-reflex coating; anti-scratch Batteries 3 x 1.5 V Alkaline D-size batteries Battery life 28 days (continuous operation) I/O functionality PC operating system Accessories Geophone, mini-usb WIN10/WIN8/WIN7 VIB.00320 Cable reel (50m) VIB.00407 Alarm beacon VIB.00420 USB adapter. External power via USB adapter: V mains 100 240 V, 47 63 Hz

DATASHEET VIBRA-series (VIB.00100/..120/..130) VIBRA-series: VIBRA, VIBRA + Detailed features overview VIBRA VIBRA + Maximum velocity v and frequency Maximum acceleration a Maximum displacement u Trace option AD-converter Resolution display Resolution AD-converter DIN SBR Velocity versus time curve 24 bits delta sigma data conversion 0.01 mm/s 0.001 mm/s Accuracy DIN 45669-1:2010-09 Frequency characteristic Lower limit: 1 Hz Dominant frequency determination Upper limit I: 80 Hz Upper limit II: 315 Hz Zero Crossing Method Data processing DIN 4150-2 FFT (Hanning window) DIN 4150-3 Accuracy Part A and B, 2002 0.85 Δ 1.15 Frequency characteristic Part A: Lower limit (-3 db): 0.8 Hz Upper limit (-3 db): 125 Hz Part B: Lower limit (-3 db): 0.8 Hz Upper limit (-3 db): 100 Hz Dominant frequency determination Method I, Method II Data processing SBR Part A, SBR Part B Sample frequency Velocity data save level Alarm level velocity v Alarm level displacement u Alarm level acceleration a 1024 Hz Adjustable between 0.01-100 mm/s (or always) Adjustable between 0.01-100 mm/ s (or none) Adjustable in mm (or none) Adjustable in m/s 2 (or none) Clock stability 5 minutes/year at 25 C Smart alarm level Optical signal device External power Wireless data transmission including FTP, SMS, e-mail Ring memory VIBRA PC Trace Recorder VIBRA geophone Geophone detection Digital correction of the sensitivity Digital correction of the f res and Q Automatic inclination check Automatic calibration check PC software WIN 10/WIN 8/WIN 7 Processing according to SBR-guidelines Processing according to a.o. DIN-guidelines Frequency dependent velocity alarm, complying with DIN/SBR Flashing wireless alarm beacon 5 Volt supplied to the VIBRA USB connector Transfer via integrated GPRS/3G modem Including ring buffer in FTP mode Continuous time/velocity trace recording Extensive graphical data presentation including precise date time axis. Various data exporting options, e.g. as ASCII-(*.csv) file VIBRA PC Remote Control VIB010/02/2016

DATASHEET VIBRA-series (VIB.00300) VIBRA geophone Profound VIBRA geophone The Profound geophone for the VIBRA-series has been designed for high-performance vibration monitoring. Advanced mounting The ball joint in combination with the wall bracket facilitates precise orientation of the geophone in the correct x-, y- or z-direction, as well as enabling fine tuning of the vial. The geophone has an electronic datasheet, which also includes the serial number. Therefore, the source of measurement data can always be traced. High-performance Besides continuously monitoring the x-, y- and z-direction, the VIBRA also automatically corrects the measurement data for the individual sensitivity of each geophone channel. This guarantees high-quality measurements and performance. Technical specifications VIBRA geophone Channels 3 (x-, y-, z-direction) Sensitivity 23.3 Vs/m Resonance frequency (fres) 8 Hz ± 0.5 Hz Output Resistance (Rout) 330 Ohm Quality factor (Q) 0.75 Distortion at 18 mm/s < 0.2 % and 12 Hz fres within tolerance < 15 Sensitivity of the vial 53 arc minutes (R130 mm) Electronic datasheet (ID) Serial number; calibration date; sensitivity; fres ; Rout ; Q Temperature range - 20 C to + 60 C (operating) Size Ø 74 mm Mass 0.48 kg Moving mass 11 ± 0.5 g (each channel) Accessories VIB.00320 Cable reel of 50 m VIB.00340 Geophone DIN mounting plate VIBRA + The VIBRA geophone in combination with the VIBRA + offers the following extras: Detection of the geophone s inclination, assuring that measurements are carried out with a correctly positioned geophone. Based on data from the electronic datasheet, the VIBRA + not only corrects the sensitivity, but also the resonance frequency and the quality factor with the help of digital correction filters. More information about the VIBRA-series can be found in the datasheets.

DATASHEET VIBRA-series (VIB.00350) VIBRA geophone cone Profound VIBRA geophone cone The Profound geophone cone for the VIBRA range has been designed for high-performance ground vibration monitoring, measuring dynamic soil parameters. Installation of the geophone cone with standard cone penetration rods can be done by pushing it to the desired depth. When the desired depth has been reached, the rod is slightly retracted to minimise the vibration influence of the penetration rods. The geophone cone has an electronic datasheet including the serial number. Therefore, the source of measurement data can always be traced. High-performance Besides continuously monitoring the x-, y- and z-direction, the VIBRA also automatically corrects the measurement data for the individual sensitivity of each geophone channel. This guarantees high-quality measurements and performance. VIBRA + The VIBRA geophone cone in combination with the VIBRA + offers the following extras: Detection of the geophone s inclination, assuring that measurements are carried out with a correctly positioned geophone. Based on data from the electronic datasheet, the VIBRA + not only corrects the sensitivity, but also the resonance frequency and the quality factor with the help of digital correction filters. Technical specifications VIBRA geophone cone Channels Sensitivity (typical) Resonance frequency (fres) Output Resistance (Rout) Quality factor (Q) 0.75 Distortion at 18 mm/s and < 0.2 % 12 Hz fres within tolerance < 15 3 (X-, Y-, Z-direction) 23.3 Vs/m 8 Hz ± 0.5 Hz 330 Ohm Max. inclination 5 Electronic datasheet (ID) Serial number; calibration date; sensitivity; fres; Rout; Q Protection rating IP66 according to DIN 40 050/IEC 529 Material 42CrMo4V Density 4500 kg/m 3 Cone diameter Ø 49.5 mm Cone length 190 mm 1.28 kg Moving mass 11 ± 0.5 g (each channel) Screw thread GeoMil standard for CPT tubes VIBRA connector LEMO K Series Cable length 15 m cable Accessory VIB.00320 cable reel 50 m 10 2 MEASURING RANGE VIBRA velocity [mm/s] 10 1 Geophone f= 8 Hz Q=0.707 DIN 45669-1 calibration point DIN 45669-2 free standing geophone a < 3m/s 2 and f < 100 Hz Geophone displacement limit 0.8 mm Geophone displacement limit 0.8 mm inclination 5 degrees Vibra v max = 100 mm/s u max < 0.8 mm 10 0 10 0 10 1 10 2 frequency [Hz]

DATASHEET VIBRA-series (VIB.00407) VIBRA wireless alarm beacon 2.0 Profound VIBRA alarm beacon The VIBRA wireless alarm beacon is a rechargeable battery powered portable alarm that provides a visible alarm signal for a vibration monitoring system from the VIBRA-series. After starting a measurement and upon exceeding a preset alarm threshold, the VIBRA system will automatically show an alarm text on the display. Simultaneously the VIBRA system transmits a wireless alarm signal to the alarm beacon. The high intensity LED s of the alarm beacon effectively notify personnel of an exceeded vibration threshold. Flexible use The VIBRA wireless alarm beacon will receive alarm signals from all VIBRA systems within range, but can also be programmed to solely receive alarm signals from specifically linked VIBRA systems. Several beacons can also be linked to one VIBRA system. Due to the wireless design and the integrated mounting options the beacon can easily be placed at clearly visible locations. If another alarm device is required, the internal relay of the VIBRA wireless alarm beacon offers a flexible opportunity to link to other alarm devices. Long operating life The internal battery guarantees a long operating life. To indicate that the battery needs to be charged, the beacon will give a clearly visible red signal. Technical specifications VIBRA wireles alarm beacon 2.0 Flashing frequency LED colours Max. luminous intensity Alarm colour Alarm threshold range Alarm duration Max. distance between beacon and VIBRA Internal battery Operating life: standby Operating life: flashing Auto shut-off f flash = 0.5 5 Hz Various signal patterns for different status Red, orange, green 3 x 25 cd High intensity red 0.1 to 99.9 mm/s (set with the VIBRA) During 1, 2, 5, 10, 15, 30, 60 minutes or manual switch off (set with the VIBRA) 30 metres Lithium-ion battery Charger 12V [charging time: 1 hour (80%)] ± 14 days ± 15 hours > 12 hours after last operation and no wireless signal received Battery-low indication f flash = 2 Hz (during alarm) f flash = 1 Hz (in standby mode) additional red flash during green or orange signal Temperature range - 10 C to + 50 C Housing Body: Black Pom Lens: PMMA Dimensions 85 mm, Ø 110 mm 0.8 kg Mounting options Bottom side : 5/8" screw thread Connector M12 speedcon, 5-pos. Relais contact AC 125V/1A Linking option for all models Up to 100 VIBRA systems to one beacon or several beacons to a single VIBRA Accessories Charger 12V 0.3A Car charger VIB.00434 Connection cable between VIBRA mini USB and alarm beacon VIB.00436 Fly-lead cable for connection to internal relay