Series 9000 Total Hydrocarbon Analyzer

Similar documents
HFID Heated Total Hydrocarbon Analyzer Module

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

FIXED GAS ANALYZER (FGA)

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

A New Standard of Excellence

Toxic Gas Detection. Model F12. Toxic Gas Detection

Model D12-IR. Digital Gas Transmitter...

Warranty Registration

Process Gas Chromatograph

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

CALIDUS tm the Modular micro Gas Chromatograph

SAM-MAX Refrigerant Monitors

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Recent Improvements in Process GC Instrumentation

931D Style B Process Gas Chromatograph

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Tri-Tech Medical Inc.

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Monitoring Flammable Vapors and Gases in Industrial Processes

ALTAIR 5X Multigas Detector Product Specification

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Complete Gas Analysis

ULTIMA X5000. MSAX5000.com

Frequently Asked Questions

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Gas Detection - GD -

Med Touch Combination Alarm Conversion Kits

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

MSA Fixed Gas & Flame Detection for the Automotive Industry

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

CS744 Series: Carbon/Sulfur by Combustion

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd

Products and performance

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Constant climate chambers

APPLICATION DATA SHEET

Mercury Vapor Monitor VM-3000

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL

Dew-Point Transmitters and Instruments

SERVOMEX PRODUCT GUIDE

VM-3000 Mercury Vapor Monitor

APPLICATION DATA SHEET

Thermo Scientific TVA2020 Introduction

VM-3000 Mercury Vapor Monitor

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

EuroFID Gas Analyzers for Measurement of the Total Hydrocarbon Content

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Sieger Apex. Flexibility that meets your requirements

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Operation and Maintenance Manual

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Dräger X-am 7000 Multi-Gas Detection

Recalibrate the way you look at gas detection

APPLICATION DATA SHEET

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Two-Channel Gas Controller

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Constant climate chambers

S5000 Gas Monitor. GMS5000.com

T.ex Single Gas Detector VISA

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview

PUV, PIR and PFO Series BROCHURE

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Analyze IT. Process Gas Chromatograph. PGC2000 Series

GAS ANALYSIS / DETECTION Gas Detector

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Constant climate chambers

Trace Moisture Analyzer for Inert, Passive,Toxic, and Corrosive Gases

Process Gas Chromatograph

Process Gas Chromatograph

PRODUCT CONFORMITY CERTIFICATE

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

SERIES 4030 HEATED THC

Constant climate chamber with humidity

Datalogging as standard

IGD.CO.UK

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

EXAMPLES OF HOW TO ORDER

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Model D12. Digital Gas Transmitter

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze

Transcription:

Series 9000 Total Hydrocarbon Analyzer Analyzer The Baseline Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides unparalleled flexibility and offers continuous, fully automated gas analysis over a broad range of concentrations. The 9000 has a dynamic range from less than 10 ppb on the low range version and up to 100% as methane on the high range version. The analyzer has a generous complement of analog, digital and logic output capabilities. The analyzer is based on a flame ionization detector (FID) with FlowGuard electronic control that delivers a small portion of the sample gas to the detector flame. During the combustion process, organic or hydrocarbon-based gases in the sample are ionized then they are detected by the instrument and reported as a concentration. The Series 9000 can be configured with internal components for single or multipoint analysis of non-condensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument. These features place the instrument well ahead of the competition in performance, automation, and configurability. Applications The Series 9000 is designed to continuously monitor the total hydrocarbon content of non-condensing gases in a variety of applications, such as: Beverage grade CO analysis 2 Scrubber & oxidizer efficiency Carbon bed breakthrough detection Contaminant analysis in pure/ultrapure inert gases Well logging Industrial hygiene & safety monitoring Fenceline (perimeter) monitoring around industrial sites LEL monitoring Features Flame ionization detector. 3U case, 19 (48.3cm) rack mountable. Automatic calibration at user-defined intervals. Internal, multipoint sampling option. FlowGuard electronic control of fuel, air and sample. Electronic back-pressure regulator with sample bypass system ensures fast response. Discrete, multilevel concentration & fault alarms. Analog output ranges programmable from 1ppm 100% full scale. Programmable relays for concentration alarms, events and diagnostics. Automatic FID ignition, with automatic shut-off of sample, fuel and combustion air. Remote operation via RS-232 and Ethernet. Graphical display and easy to use menu system. Optional 9000 Keeper software to monitor and control the instrument remotely. www.baseline-mocon.com

Series 9000 Total Hydrocarbon Analyzer Analytical Detector: Flame ionization detector (FID). Ranges: User definable based upon calibration within: MDQ 0.01ppm, Full-scale 1-200ppm (Methane) MDQ 0.1ppm, Full-scale 1-2,000ppm (Methane) MDQ 0.3ppm, Full-scale 1-20,000ppm (Methane) MDQ 0.003%, Full-scale 0.01-100% (Methane) Repeatability: +/- 1% Full-scale response. Drift: +/- 1% of full-scale over 24 hours. Response Time: < 5 seconds to 90% of final reading. Alarms: Multilevel concentration and fault alarms that result in audible and visual alarms. Alarms may also be mapped to relays to control external equipment. Sampling: Internal single or multipoint modules, for pre-filtered (<0.1 microns) non-condensing samples, with or without sample pump. Calibration: Programmable automatic or manual calibration. Support Gas: Hydrogen 35 cc/min, Air 175 cc/min (typical). Hydrocarbon content must be less than 1 ppm. Fuel blend options available, consult Baseline. Physical Dimensions: 19.00 (48.3cm) W x 14.25 (36.2cm) D x 5.25 (13.3cm) H. Weight: < 20 lb (9.07kg). Configuration: Bench-top or rack-mount 19 (48.3cm) panel. Connections: 1/4 (6.35mm) tube fitting connectors. Operating Temperature: 32-104 F (0-40 C). Operating Humidity: 0 95% (non-condensing). Electrical Power: 90 230 VAC, 50/60Hz, 3A. Display: 3.4 (8.6cm) x 4.5 (11.4cm) graphical display. Relay Outputs: 5 programmable form A relays rated to 3A @ 230V AC (optional additional 9 relay output Analog Outputs: 1 programmable 0-20mA or 4-20mA isolated output (optional additional 3 analog output Digital Outputs: RS-232, Ethernet. P.O. Box 649, 19661 Highway 36 Lyons, CO 80540 P: 1.800.321.4665 1.303.823.6661 F: 303.823.5151 E: Sales@BaselineIndustries.com D011.4

Series 9000 NMHC NonMethane Hydrocarbon Analyzer Analyzer The Baseline Series 9000 NMHC is a specialized member of the extraordinary Series 9000 family of gas analyzers. The Series 9000 is the candidate of choice whenever accurate, reliable total, Methane, and NonMethane analysis is required. The Series 9000 analyzer provides unparalleled flexibility and offers continuous, fully automated gas analysis over a broad range of concentrations. The Series 9000 NMHC is designed to measure the total, methane, and non-methane hydrocarbon content of gas samples. The analyzer has a generous complement of analog, digital and logic output capabilities. The analyzer is based on a flame ionization detector (FID) and an oxidation catalyst that is switched in and out of a portion of the sample stream. The catalyst oxidizes all hydrocarbons except methane, for a methane measurement. The methane value is then automatically subtracted from the total hydrocarbon concentration to determine the nonmethane hydrocarbon reading. The Series 9000 NMHC can be configured with internal components for single or multipoint analysis of noncondensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument. These features place the instrument well ahead of the competition in performance, automation, and configurability. Applications The Series 9000 NMHC is designed to continuously monitor the total hydrocarbon content of non-condensing gases in a variety of applications, such as: Ambient Air Monitoring Networks Clean Rooms Air & Oxygen Purity in Air Separation Plants Features Flame ionization detector. 3U case, 19 (48.3cm) rack mountable. Hydrocarbon detection from sub-ppm to 1000ppm (Methane). Automatic calibration at user-defined intervals. Internal, multipoint sampling option. FlowGuard electronic control of fuel, air and sample. Electronic back-pressure regulator with sample bypass system ensures fast response. Discrete, multilevel concentration & fault alarms. Programmable analog output ranges. Programmable relays for concentration alarms, events and diagnostics. Automatic FID ignition, with automatic shut-off of sample, fuel and combustion air. Remote operation via RS-232 and Ethernet. Graphical display and easy to use menu system. Optional 9000 Keeper software to monitor and control the instrument remotely. www.baseline-mocon.com

Series 9000 NMHC NonMethane Hydrocarbon Analyzer Analytical Detector: Flame ionization detector (FID). Oxidizer: Oxidizes NonMethane gases. Range: User definable based upon calibration within: MDQ 0.06ppm, Full-scale 1-200ppm (Air Balance) MDQ 0.1ppm, Full-scale 1-1000ppm (Air Balance) MDQ 0.03ppm, Full-scale 1-200ppm (O 2 Balance) Repeatability: +/- 1% Full-scale response. Drift: +/- 1% of Full-Scale over 24 hours. Response Time: T90 < 30 sec. Alarms: Multilevel concentration and fault alarms that result in audible and visual alarms. Alarms may also be mapped to relays to control external equipment. Sampling: Internal single or multipoint modules for pre-filtered (<0.1 microns), non-condensing samples with or without sample pump. Calibration: Programmable automatic or manual calibration. Support Gas: Hydrogen 35 cc/min (H 2 He Blend 100cc/ min), Air 175 cc/min (typical). Hydrocarbon content must be less than 1 ppm. Fuel blend options available, consult Baseline. Physical Dimensions: 19.00 (48.3cm) W x 14.25 (36.2cm) D x 5.25 (13.3cm) H. Weight: < 20 lb (9.07kg). Configuration: Bench-top or rack-mount 19 (48.3cm) panel. Connections: 1/4 (6.35mm) tube fitting connectors. Operating Temperature: 32-104 F (0-40 C). Operating Humidity: 0 95% (non-condensing). Electrical Power: 90 230 VAC, 50/60Hz, 3A. Display: 3.4 (8.6cm) x 4.5 (11.4cm) graphical display. Relay Outputs: 5 programmable form A relays rated to 3A @ 230V AC (optional additional 9 relay output Analog Outputs: 1 programmable 0-20mA or 4-20mA isolated output (optional additional 3 analog output Digital Outputs: RS-232, Ethernet. P.O. Box 649, 19661 Highway 36 Lyons, CO 80540 P: 1.800.321.4665 1.303.823.6661 F: 303.823.5151 E: Sales@BaselineIndustries.com D018.5

Series 9000 TCA Total Carbon Analyzer Analyzer The Baseline Series 9000 TCA is a specialized member of the extraordinary Series 9000 family of gas analyzers. The Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon and total carbon analysis is required. The Series 9000 analyzer provides unparalleled flexibility and offers continuous, fully automated gas analysis over a broad range of concentrations. The Series 9000 TCA has a dynamic range from less than 0.1 ppm to 100 ppm, it s designed to measure total hydrocarbon content and provide a combined carbon monoxide (CO) and carbon dioxide (CO 2 ) reading. The analyzer has a generous complement of analog, digital and logic output capabilities. The analyzer is based on a flame ionization detector (FID) and a reduction catalyst that is switched in and out of a portion of the sample stream. Total hydrocarbons are measured first, and then the catalyst switches in. The catalyst converts the CO & CO 2 to methane and leaves the hydrocarbons unchanged for a total carbon measurement. The total hydrocarbon value is then automatically subtracted from the total carbon concentration to determine the combined CO/CO 2 reading The Series 9000 TCA can be configured with internal components for single or multipoint analysis of noncondensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument. Applications The Series 9000 TCA is designed to continuously monitor total hydrocarbons and trace levels of CO/CO 2 in order to provide a total carbon reading. This specialized analyzer is configured for the detection of hydrocarbon and CO/CO 2 impurities in pure and ultrapure inert gases such as argon, helium, hydrogen, and nitrogen. Samples must be free of oxygen. Features Flame ionization detector. 3U case, 19 (48.3cm) rack mountable. Hydrocarbon detection from sub-ppm to 100 ppm levels. Automatic calibration at user-defined intervals. Internal, multipoint sampling option. FlowGuard electronic control of fuel, air and sample. Electronic back-pressure regulator with sample bypass system ensures fast response. Discrete, multilevel concentration & fault alarms. Analog output ranges programmable from 1ppm 100% full scale. Programmable relays for concentration alarms, events and diagnostics. Automatic FID ignition, with automatic shut-off of sample, fuel and combustion air. Remote operation via RS-232 and Ethernet. Graphical display and easy to use menu system. Optional 9000 Keeper software to monitor and control the instrument remotely. www.baseline-mocon.com

Series 9000 TCA Total Carbon Analyzer Analytical Detector: Flame ionization detector (FID). Methanizer: Converts low levels of CO and CO 2 to methane. Range: User definable based upon calibration within: 0-100 ppm (Methane). MDQ: 0.1 ppm (100 ppb). Repeatability: +/- 1% Full-scale response. Drift: Zero: +/- 1% Full-scale over 24 hours Response Time: T90 < 30 sec. Alarms: Multilevel concentration and fault alarms that result in audible and visual alarms. Alarms may also be mapped to relays to control external equipment. Sampling: Internal single or multipoint modules for pre-filtered (<0.1 microns), non-condensing samples, with or without sample pump. Physical Dimensions: 19.00 (48.3cm) W x 14.25 (36.2cm) D x 5.25 (13.3cm) H. Weight: < 20 lb (9.07kg). Configuration: Bench-top or rack-mount 19 (48.3cm) panel. Connections: 1/4 (6.35mm) tube fitting connectors. Operating Temperature: 32-104 F (0-40 C). Operating Humidity: 0 95% (non-condensing). Electrical Power: 90 230 VAC, 50/60Hz, 3A. Display: 3.4 (8.6cm) x 4.5 (11.4cm) graphical display. Relay Outputs: 5 programmable form A relays rated to 3A @ 230V AC (optional additional 9 relay output Calibration: Programmable automatic or manual calibration. Support Gas: Hydrogen 40 cc/min, Air 200 cc/min. (typical). Hydrocarbon content must be less than 1 ppm. Fuel blend options available, consult Baseline Analog Outputs: 1 programmable 0-20mA or 4-20mA isolated output (optional additional 3 analog output Digital Outputs: RS-232, Ethernet. P.O. Box 649, 19661 Highway 36 Lyons, CO 80540 P: 1.800.321.4665 1.303.823.6661 F: 303.823.5151 E: Sales@BaselineIndustries.com D019.4

Series 9000 H Heated Hydrocarbon Analyzer Analyzer The Baseline Series 9000 H is a high-temperature member of the extraordinary Series 9000 family of gas analyzers. The Series 9000 is the candidate of choice whenever accurate, reliable hydrocarbon analysis is required. The Series 9000 H has a dynamic range from 0.1 ppm to 10% (Propane) or 0.3 ppm to 50% (Methane). The analyzer has a generous complement of analog, digital and logic output capabilities. These features place the instrument well ahead of the competition in performance, automation, and configurability. The analyzer is based on a flame ionization detector (FID) with FlowGuard electronic control that delivers a small portion of the sample gas to the detector flame. During the combustion process, organic or hydrocarbon-based gases in the sample are ionized then they can be detected by the instrument and reported as a concentration. The Series 9000 H is configured for single point analysis of samples heated up to 376 F (191 C). The automatic calibration feature enhances the long-term analytical stability of the instrument. Applications The Series 9000 H is designed to continuously monitor the total hydrocarbon content of gases and maintain the temperature of heated sample above their dew point. This extremely versitile instrument can be configured to support a variety of applications, such as: Compliance monitoring for EPA Methods 25A & 503 Continuous Emission Monitoring (CEM) of source hydrocarbons Scrubber & oxidizer efficiency Carbon bed breakthrough detection LEL monitoring Vehicle emissions Chemical process blending Features Flame ionization detector. 3U case, 19 (48.3cm) rack mountable. Hydrocarbon detection from sub-ppm to 50% levels (Methane). Automatic calibration at user-defined intervals. FlowGuard electronic control of fuel, air and sample. Electronic back-pressure regulator with sample bypass system ensures fast response. Discrete, multilevel concentration & fault alarms. Programmable relays for concentration alarms, events and diagnostics. Automatic FID ignition, with automatic shut-off of sample, fuel and combustion air. Remote operation via RS-232 and Ethernet. Graphical display and easy to use menu system. Optional 9000 Keeper software to monitor and control the instrument remotely. www.baseline-mocon.com

Series 9000 H Heated Hydrocarbon Analyzer Analytical Detector: Flame ionization detector (FID). Sample Temperature: Up to 376 F (191 C). Ranges: User definable based upon calibration within: MDQ 0.3ppm, Full-scale 1 to 2,000ppm (Methane) MDQ 0.6ppm, Full-scale 1 20,000ppm (Methane) MDQ 0.003%, Full-scale 0.01 50% (Methane) Repeatability: +/- 1% Full-scale response. Drift: +/- 1% of Full-Scale over 24 hours. Response Time: T90 < 5 sec. Alarms: Multilevel concentration and fault alarms that result in audible and visual alarms. Alarms may also be mapped to relays to control external equipment. Sampling: Internal single module for pre-filtered (<0.1 microns), non-condensing samples, with or without sample pump. Calibration: Programmable automatic or manual calibration. Support Gas: Hydrogen 40 cc/min, Air 200 cc/min. (typical). Hydrocarbon content must be less than 1 ppm. Fuel blend options available, consult Baseline Physical Dimensions: 19.00 (48.3cm) W x 14.25 (36.2cm) D x 5.25 (13.3cm) H. Weight: < 25 lb (11.3kg). Configuration: Bench-top or rack-mount 19 (48.3cm) panel. Connections: 1/4 (6.35mm) tube fitting connectors. Operating Temperature: 32-104 F (0-40 C). Operating Humidity: 0 95% (non-condensing). Electrical Power: 90 230 VAC, 50/60Hz, 3A. Display: 3.4 (8.6cm) x 4.5 (11.4cm) graphical display. Relay Outputs: 5 programmable form A relays rated to 3A @ 230V AC. Analog Outputs: 1 programmable 0-20mA or 4-20mA isolated output. Digital Outputs: RS-232, Ethernet. P.O. Box 649, 19661 Highway 36 Lyons, CO 80540 P: 1.800.321.4665 1.303.823.6661 F: 303.823.5151 E: Sales@BaselineIndustries.com D025.3

Series 9000 Analyzer Versions Model 9000 THA 9000 NMHC 9000 H 9000 TCA Description Fully Automated Hydrocarbon Analyzer Methane / Non-Methane Hydrocarbons Fully Automated Heated Hydrocarbon Analyzer Total Carbon Analyzer (THC+CO+CO 2 in inert gases, except air & O 2 ) Detector FID FID with Oxidizer Catalyst FID FID with Methanizer Catalyst Sample Points 1 and 4 point 1 and 4 point 1 point 1 and 4 point Sampling Type 4 point is Sequential 4 point is Sequential Continuous 4 point is Sequential Outputs Standard: 5 relays, 1 analog, RS-232, Ethernet Optional: Additional 9 relays & 3 analogs Standard: 5 relays, 1 analog, RS-232, Ethernet Optional: Additional 9 relays & 3 analogs Standard: 5 relays, 1 analog, RS-232, Ethernet Standard: 5 relays, 1 analog, RS-232, Ethernet Optional: Additional 9 relays & 3 analogs Internal Wetted Parts Stainless Steel Stainless Steel Stainless Steel Stainless Steel Sample Temperature Ambient Ambient Up to 191 C (376 F) Ambient Repeatability Drift +/- 1% full scale +/- 1% full scale +/- 1% full scale +/- 1% full scale +/- 1% over 24 hours +/- 1% over 24 hours +/- 1% over 24 hours +/- 1% over 24 hours Gas Flow Control Electronic Electronic Electronic Electronic User selectable within: User selectable within: User selectable within: User selectable within: 0.01 to 100ppm 0.06 to 200ppm (Air balance) 0.3 to 2000ppm 0.1 to 100ppm Ranges & MDQ 0.1 to 2000ppm 0.1 to 1000ppm (Air balance) 0.6 to 20000ppm (as Methane) 0.3 to 20000ppm 0.03 to 200ppm (O 2 balance) 0.003% to 50% 0.003% to 100% Calibration Automatic or Manual Automatic or Manual Automatic or Manual Automatic or Manual Calibration Plumbing Optional: Internal Zero/Span Valves Optional: Internal Zero/Span Valves Optional: Internal Zero/Span Valves Optional: Internal Zero/Span Valves www.baseline-mocon.com P.O. Box 649, 19661 Highway 36 Lyons, CO 80540 P: 1.800.321.4665 1.303.823.6661 F: 303.823.5151 E: Info@BaselineIndustries.com D031.1