Jülich Solar Power Tower System Behavior During Downtime

Similar documents
Compression of Fins pipe and simple Heat pipe Using CFD

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Incorporating Aluminum Honeycomb to Increase Efficiency of U-tube Removable Heat Exchanger

ENSC 388: Engineering Thermodynamics and Heat Transfer

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

Performance Study of Triple Concentric Pipe Heat Exchanger

Computer Modelling and Simulation of a Smart Water Heater

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Effect of the Use Pattern on Performance of Heat Pump Water Heater

2. HEAT EXCHANGERS MESA

NEBRASKA MODIFIED ROOF POND: 1985 SUMMER PERFORMANCE RESULTS

PCM-module to improve hot water heat stores with stratification: first tests in a complete solar system

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

(Refer Slide Time: 00:00:40 min)

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Don t Turn Active Beams Into Expensive Diffusers

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

BEKA ceiling heating versus traditional underfloor heating

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

How is the heat transfer?

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

Desiccant Cooling with Solar Energy

Induction Billet Heaters with Enthalpy Controlled Zone Heating

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Drying Parawood with Superheated Steam

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

PERFORMANCE MONITORING OF A HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMP WITH INJECTION CYCLE INSTALLED IN A LOW-INSULATED SINGLE-FAMILY HOUSE IN BELGIUM

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

MINIMISING THE RISK OF WATER HAMMER AND OTHER PROBLEMS AT THE BEGINNING OF STAGNATION OF SOLAR THERMAL PLANTS- A THEORETICAL APPROACH

An experimental study of the impact of tunnel suppression on tunnel ventilation

Falling Film Heat Exchangers for Solar Water Heaters

Design and Experimental Studies on Modified Solar Dryer

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Investigating the Effects of Sprinkler Sprays on Fire-Induced Doorway Flows: A Two-Part Study. Jeremiah Crocker and Dr. Bin Xiao New Technology Team

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

Numerical study of heat pipe application in heat recovery systems

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Pocket Dilution Cooler

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Investigation of a Novel Ceiling Panel for Heat and Moisture Control in Buildings

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Boiler Venting. Definitions, Theory and Applications. Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX

Figure 1: Overview of CO 2 evaporator types

Efficient Steam System Design

American International Journal of Research in Science, Technology, Engineering & Mathematics

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

Purdue e-pubs. Purdue University

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

So far, we have covered the basic concepts of heat transfer and properties.

Mathematical Simulation of Longan Fruit Drying

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Impact of TXV and Compressor in the Stability of a High-End Computer Refrigeration System

Transcription:

Jülich Solar Power Tower System Behavior During Downtime Torsten Baumann 1, a), Felix Göhring 1, b), Hannes Stadler 1,c) and Till Doerbeck 2,d) 1 German Aerospace Center (DLR), Institute of Solar Research, Karl-Heinz-Beckurts-Str. 13, 52428 Jülich, Germany 2 Kraftanlagen München GmbH, Solar Technology/Energy and Environment Technology, Ridlerstraße 31c, 80339 München, Germany a) Corresponding author: torsten.baumann@dlr.de b) felix.goehring@dlr.de c) hannes.stadler@dlr.de d) till.doerbeck@kraftanlagen.com Abstract. At the Jülich Solar Power Tower, two new shut-off dampers have been installed in the hot air piping system in order to reduce thermal losses during downtime of the plant. The thermodynamic behavior of the thermal energy storage and the steam boiler has been investigated with respect to heat losses after shut-down of the plant. Also, the change of temperature and the pressure drop at both shut-off dampers during downtime has been analyzed. Results show that for the storage, a reduction of thermal losses can be achieved by closing the damper overnight. Regarding the steam boiler, no improvements on heat losses were observed. If only two of the four storage chambers have been charged during operation, heat transfer between the chambers is observed after shut-down. It is concluded that natural convection is not the main source of thermal overnight losses, however, it can be lowered thanks to the dampers. Heat conduction and convectional heat transfer at the surfaces also contribute to the decrease of thermal energy, which can be lowered by thicker insulation layers in the future. INTRODUCTION The Jülich Solar Power Tower is Germany s first and only solar tower power plant for experimental and demonstration purposes applying an open volumetric receiver technology and is described in [1] and [2] in more detail. During solar operation, ambient air is sucked in and is being heated by a solar heated ceramic structure of the receiver. Subsequently, the hot air (up to 700 C) flows either through the thermal energy storage (TES) or through the steam boiler. A schematic of the plant is shown in Fig. 1. The TES is a regenerator heat storage type with a ceramic honeycomb structure as sensible storage material. The plant s steam generator is a shell boiler with the hot air running through tubes and water in the shell. During power plant operation, the hot air runs the steam generator, which in turn generates steam in order to run a Rankine cycle. Part of the hot air is used to simultaneously charge the TES during solar operation, e.g. if excess radiation is available. For a commercial CSP plant, the storage is usually fully charged at daytime and subsequently discharged in the evening or night time in order to keep the steam boiler running. The steam boiler runs at operation pressure before the plant is shut-down each day. If the storage is not discharged during operation (e.g. due to a low energy demand or due to test reasons like in this case), the system is shut down in a high thermodynamic state. This state can be favorable for a quick start-up of the system the next morning, since theoretically no heat-up phase is necessary. In practice, not the full thermal energy is available after overnight standstill due to thermal losses.

FIGURE 1. Schematic of the Jülich Solar Power Tower with the two new shut-off dampers Internal studies have shown that a certain amount of heat is lost overnight presumably due to convectional heat losses. Since the air loop of the plant is not a fully closable system, convection is induced by the temperature difference to the ambient. This in turn leads to a decreasing temperature in the storage and a decreasing pressure in the steam boiler. In order to overcome the convectional losses of the air piping system, two shut-off dampers had been installed: one between the air inlet, which is the receiver, and the TES, and another between the air inlet and the steam generator. The position of both dampers is shown in Fig. 1. Both dampers should be shut close after system shut-down in order to keep the thermal energy inside the storage and the steam boiler, respectively. This study focuses on how this effort contributes to the reduction of thermal losses and the characterization of both dampers. The transient local temperature and pressure loss at each damper is analyzed as well as the temperatures inside the storage and the steam pressure of the steam boiler. EXPERIMENTAL SETUP The TES consists of four equally sized chambers, each virtually separated into eight levels. The chambers can be charged and discharged independently. All chambers of the storage are equipped with 24 thermocouples, three of them in each level. These thermocouples will be applied in order to account for the local temperature changes in each chamber over standstill time. In order to quantify the thermal state of the boiler, the steam pressure is taken into account. Since the pressure of the steam directly depends on the steam temperature, the pressure represents the enthalpy of the steam. Additionally, the temperature and the pressure loss behavior at the new dampers will be characterized. To that end, thermocouples and pressure transducers have been installed at each inlet and outlet of the two shut-off valves. Some of the measurement sensors were already pre-installed, some others (e.g. all of the pressure sensors) had to be retrofittet for this campaign. The transient behavior of temperature and pressure will be derived from the unsteady state directly after switching off the system. The pressure loss measurement also allows for the determination of the pressure loss coefficient from different steady state operations.

FIGURE 2. Hot air piping system from the receiver to the storage and the steam boiler with the new shut-off dampers In order to achieve controllable and constant temperatures in the air loop for these tests, a gas burner which is installed directly behind the air inlet (see Fig. 1.) is used to heat up the incoming air from the receiver. Thus, no solar operation is applied for the experiments. This allows for constant temperatures up to 600 C at the air inlet with mass flow rates between 5 kg/s and 10 kg/s during operation. The data for unsteady behavior are recorded usually for 12 h directly after shut-down for different system configurations are summarized in table 1. At shut-down, all valves of the piping system are being closed (partially excluding the both new dampers) and the blower is shut off. As can be seen from the table, each configuration has been run with both dampers closed and opened as well. The open cases represent a system without the new shut-off dampers. The boiler was set to a pressure of approx. 20 bars before shut-down for each case. The storage was charged with approx. 600 C for all four chambers or only two chambers, respectively. If only two chambers have been charged during operation, the other two have been left with their current temperature. They still may remain warm from former experiments, although the temperature is noted as 20 C in table 1. All experiments have been carried out in October 2015, with ambient temperatures between 7 C and 15 C. TABLE 1. Parameters for the test campaign; all values are target temperatures and pressures, respectively T Storage [ C] p Boiler [bar] New dampers Inventory dampers 600 20 closed closed 600 20 open closed 600/20 20 closed closed 600/20 20 open closed RESULTS AND DISCUSSION In this section, firstly, the overnight thermodynamic behavior of the storage and the steam generator will be presented. Additionally, the unsteady progress of temperature and the pressure at each damper will be looked at. Thermodynamic behavior of TES The progress of the mean TES temperature versus standstill time is shown in Fig. 3 for all chambers fully loaded with the damper at the storage left open, Fig. 4 shows the same diagram with the damper closed. Both figures show a decrease of the mean temperature within 12 h. For the closed damper case, the cooling rate is somewhat lower than for the open damper case: The linear cooling rates for the first and the second case are 1.64 K/h and 1.51 K/h, respectively. The difference in cooling rates represents a reduction of thermal losses of 8 % if the shut-off damper at the TES is closed.

In order to analyze the temperature progress inside the storage more closely, the local temperatures at each level of the four chambers are plotted over the storage height at both shut-down and before restart in Fig. 5 and Fig. 6. All four chambers exhibit the same temperature profiles. It should be noted that the temperature is not equally distributed in each chamber: the lower levels exhibit significantly lower temperatures than the upper levels. This is due to technical restrictions since the air blower, which is located behind the storage, must not take temperatures higher than 200 C. To that end, the charging process of the TES is stopped as soon as the outlet temperature at the lower end of each chamber comes close to 200 C, that is why an almost linear decrease of temperature from level one to level three develops. Storage temperature Storage temperature Time Time FIGURE 3. Mean temperature of TES with damper open FIGURE 4. Mean temperature of TES with damper closed It is obvious that the temperature generally decreases from start (time of shut-down of the plant) to end of the measurement, as already described above. It becomes clear that a high amount of thermal energy losses take place at the uppermost part of the storage. In the upper mid section (level 5 to 7), the temperature remains almost constant, a clear deviation is visible between level 3 and 5. In the lower levels, only very little change of temperature happens during standstill. To easily locate the areas of significant temperature change, the local temperature differences after 12 h in all chambers are plotted as contours in Fig. 7 and Fig. 8 for both cases. It becomes obvious that the highest thermal losses take place at level 8 and also the area around level 3. This indicates that a significant amount of heat from the storage gets lost to the dome and the piping connection to the storage. A drawing of the thermal energy story of the Jülich Power Tower is shown in Fig. 9. It is assumed that heat conduction through the storage and piping material causes the thermal energy loss, since the temperature gradient of the piping, which leads to the receiver, induces heat flow through the material. This in turn leads to a reallocation of isothermals inside the storage since hot air moves upwards to the top of the storage, which is why the temperature in the core of the storage chambers also decreases in some regions as the cooled region expands. The most significant peak of local temperature change is observed in chamber 2 for both cases. The effects seem to be almost independent from the damper being open or closed, which is owed to heat conduction through the piping material, although the temperature decrease is somewhat lower for the closed damper case. Due to the closed damper, the heat loss is restricted, which suggests that the total heat loss is only partially conduction but also convection. With the damper at the TES closed, more thermal energy remains in the storage. An additional measurement has been conducted for a 56 h standstill period with the damper at the TES closed. It can be noted that the mean temperature of storage decreases almost linearly with the same cooling rate as for the 12 h case.

FIGURE 5. Temperature profiles of the four chambers with storage damper open at shut-down (start) and after 12 h (end) FIGURE 6. Temperature profiles of the four chambers with storage damper closed at shut-down (start) and after 12 h (end) FIGURE 7. Isothermal lines of temperature change during downtime of 12 h with damper open FIGURE 8. Isothermal lines of temperature change during downtime of 12 h with damper closed

FIGURE 9. Thermal Energy Storage of the Jülich Solar Power Tower [3] The picture is different if only two of the four storage chambers have been charged during operation. As expected, the mean temperature is significantly reduced in comparison to the former case (175 C vs. 460 C at start of measurement). Simultaneously, the cooling rate is lower (0.67 K/h for the closed, 1,0 K/h for the open damper). This is due to the lower temperature difference to the ambient, which is much higher when the storage is fully charged. Also, there is thermal crossmixing between the hot and the cold chambers, which means that heat transfer occurs through the chamber walls from the charged to the uncharged chambers. On this account the temperature in the charged chambers decreases, the temperature in the cold chambers is almost stable and even increases during downtime if the damper is closed. The temperature profiles in the hot chambers are somewhat the same, no matter if the damper is open or closed. Fig. 10 and Fig. 11 show the mean temperature of all four chambers over time for the open and the closed damper case, respectively. FIGURE 10. Mean temperature of all four chambers as function of downtime with storage damper open FIGURE 11. Mean temperature of all four chambers as function of downtime with storage damper closed

FIGURE 12. Temperature profiles of the four chambers with storage damper open, at shut-down (start) and after 12 h (end); with only chamber 1 and 2 being charged FIGURE 13. Temperature profiles of the four chambers with storage damper closed, at shut-down (start) and after 12 h (end); with only chamber 1 and 2 being charged As can be seen from the temperature profiles in Fig. 12 and Fig. 13, the heat exchange is very intense in the upper part of the storage. Here, the local temperatures of the cool chambers partially exceed those of the hot chambers. This suggests that inside the top of the storage, that is the dome, which is not filled with ceramic material, air convection is induced due to the temperature gradient between the chambers. Also, heat conduction through the wall between chambers contributes to the heat exchange. With the storage partially charged and the storage damper closed, the thermal losses were reduced by 35 % compared to the case with no damper in between the receiver and the TES. Nevertheless, the total enthalpy level in this case is also reduced due to the lower temperature in two chambers. Only the two hot chambers would offer the same amount of exergy as in the fully charged case. In practice, chambers with temperatures below 200 C are useless for operating the power plant since no steam with acceptable parameters can be generated. Hence, the reduction of the usable thermal energy is only 7 % and thus comparable to the case of four charged chambers. Thermodynamic behavior of the steam boiler The transient behavior of the steam boiler, which was operated at a steam pressure of 20 bar before shut-down, is shown in Fig. 14 for the open damper and in Fig. 15 for the closed damper at the boiler. The pressure represents the level of enthalpy stored in the steam. Similar to the overnight storage temperature, the steam pressure decreases almost linearly with standstill time. After nine hours, the pressure decreased by 18 %. No difference is observed whether the damper is open or closed. The rate of pressure decrease is 0.35 bar/h for both cases. Despite the damper is closed, no reduction of thermal energy loss is achieved. This leads to the conclusion that convection in the air piping is not the primary reason for thermal losses of the system and thus negligible. The majority of heat loss to the ambient takes place via the surface of the boiler and its numerous valves and accessories, which are not or only weakly insulated for technical reasons.

FIGURE 14. Steam pressure in the steam boiler as function of downtime with damper open FIGURE 15. Steam pressure in the steam boiler as function of downtime with damper closed The TES, on the other hand, is much better insulated as a whole and the inventory has a high heat capacity. Convection in the piping contributes significantly to the total heat loss of the storage. Temperature and pressure drop at the storage-sided shut-off damper The temperatures at both sides of the damper, the one facing the receiver and the one facing the storage, during downtime are shown in Fig. 16 and Fig. 17 with the damper open and closed, respectively. While for both cases each temperature decreases with time, the receiver-sided one decreases faster. FIGURE 16. Temperatures in front (receiver-facing) and back (storage-facing) of the open storage damper as function of downtime FIGURE 17. Temperatures in front (receiver-facing) and back (storage-facing) of the closed storage damper as function of downtime The storage-facing temperature with the damper open and closed decreases by 74 K and 48 K, respectively. The difference between the two temperatures is higher for the closed damper case, while the storage-facing temperature is more stable than for the open damper case. If the damper is closed, the difference is always higher than if the damper was open. Hence, if the damper is closed, convection from the hot storage to the cooler receiver is diminished during downtime. Pressure drop at the storage damper for different overnight configurations are shown in Fig. 18. With the damper closed, the pressure drop at shut-down is below 15 Pa. The higher pressure drop with the open damper is due to free air convection (chimney effect). The air flow in the piping induces a pressure difference at the damper. The pressure drop decreases continuously in all cases within 12 h. This can be explained with the temperature at the receiver-facing side, which is decreasing faster than at the storage-facing side. This results in a decreasing driving temperature difference and thus, pressure drop.

Since a pressure drop also develops when the damper is closed it can be assumed that air continuously flows through the closed damper. Hence, the damper does not seal the cross section entirely and thermal energy gets lost due to convection. Additional pressure loss measurements have been conducted during power plant operation in order to determine the pressure loss coefficient for the open dampers. The pressure loss coefficient is a parameter of each damper and can be computed applying equation 1: ζ = 2Δp ρw 2 (1) Here, Δp is the measured pressure loss, ρ is the air density at current temperature, and w is the air velocity. Air mass flows between 5 kg/s and 10 kg/s in both directions and temperatures up to 600 C were used for these measurements. The results can be found in table 2. From the results it can be seen that pressure loss, and thus the pressure loss coefficient, is a function of flow direction. In the air direction towards the storage (used for charging), the coefficient is about 1.8 times higher than for the discharge direction. The reason for this effect is that the damper leaf is not parallel to the air flow but somewhat angled and pressure loss depends on the direction of the incident flow. It should be mentioned that within the measurement section there is a 90 -elbow installed in the piping. It is assumed the elbow contributes to the pressure loss coefficient by 0.34 (estimated according to [4]), thus this amount was subtracted from an originally computed value, in order to account for influence of the elbow in the serial chain of flow obstructions in the measurement section. FIGURE 18. Pressure drop at the storage damper for various configurations TABLE 2. Corrected values for the pressure loss coefficients at storage-sided and boiler-sided shut-off damper Damper ξ charge [-] ξ discharge [-] Storage 0.81 0.29 Boiler 0.92 - Temperature and pressure drop at the boiler-sided shut-off damper The same investigations as for the storage damper have been conducted for the steam boiler sided damper. In Fig. 19 and Fig. 20, the temperatures at the open and the closed damper are shown, respectively. Again, the differences between the temperature in front and the back of the damper are higher for the closed damper case. Also, the declining trend over time can be found. In contrary to the storage damper, the thermal losses are significantly higher, which becomes apparent by the much lower temperatures after 10 and 12 hours, respectively. The reason for this is the lower heat storage capacity of the boiler in contrast to the storage, as well as the already discussed heat losses via the surface and external instrumentations of the boiler.

FIGURE 19. Temperatures in front and back of the open boiler damper FIGURE 20. Temperatures in front and back of the open boiler damper Also, the influence of the damper on the boiler-related heat losses are considerably lower: After 10 hours, the temperature difference between the front and the back are 37 K for the closed damper (and 5 K for the open damper). Thus, the thermal losses are reduced only marginally if the damper is closed. In Fig. 21, the progression of pressure loss at the closed boiler damper over downtime is displayed. If the damper is closed, pressure drop drecreases from 19 Pa to 14 Pa during 12 h. As for the storage damper, it is assumed that there is an unintended leakage flow at the damper due to the chimney effect. The decrease of pressure drop over time is owed by the decreasing temperature difference between the front and the back of the damper. As for the storage damper, the pressure loss coefficient has also been determined for the boiler damper. In contrast to the storage damper, this one can only be flowed through in one direction (from receiver to boiler). The calculated coefficient can be found in table 2. Within the measurement section, there is a complicated change of cross section which has been accounted for with a share of 0.12, which has been subtracted of an originally calculated value. The corrected value of 0.92 is somewhat higher than for the storage damper, which may result from its slightly different geometry and fitting situation (see Fig. 2). FIGURE 21. Pressure drop at the closed boiler damper CONCLUSIONS The investigation on the new shut-off dampers, which have been installed in the air piping system of the Juelich Solar Power Tower, showed that a reduction of thermal losses can be achieved. After the shut-off dampers have been installed, thermal losses of the fully charged thermal energy storage were reduced by about 7 % by reducing convection in the piping. At the steam boiler, no such significant reduction has been reached, which is due to the

high amount of convectional heat transfer via its surface. Here, heat losses due to the chimney effect in the piping are almost negligible. Additionally, the dampers cannot perfectly seal the flow way (which would be technically impossible), which allows for air flow during down-time of the power plant system. Also, heat conduction through the damper leafs may induce additional heat losses. Same goes for the inventory dampers which may also account for heat losses during downtime. The rather low efficiency of the effort indicates that natural convection in the piping is not the major thermal loss mechanism, but heat conduction in the material and heat transfer via the surfaces. With respect to the TES, the high surface area of its dome accounts for a significant amount of heat loss. These losses can be reduced applying thicker insulation layers at the appropriate locations. Future commercial CSP plants will also feature more sophisticated steam boilers which will account for lower convectional surface losses. Although those dampers wouldn t be used on a daily basis in the first place since the storage wouldn t be fully charged overnight for normal commercial operation, they are considered useful for particular modes, e.g. if the storage should keep a certain amount of thermal energy during downtime for a quick start-up the next morning. REFERENCES 1. S. Zunft, M. Händel, M. Krüger, V. Dreißigacker, F. Göhring, E. Wahl. Jülich Solar Power Tower Experimental Evaluation of the Storage Subsystem and Performance Calculation, Journal of Solar Energy Engineering 133/3 (2011) 2. V. Kronhardt, S. Alexopoulos, M. Reißel, J. Sattler, B. Hoffschmidt, M. Hänel, T. Doerbeck. High-temperature thermal storage system for solar tower power plants with open-volumetric air receiver simulation and energy balancing of a discretized model, SolarPACES 2013, Energy Procedia 49 (2014) 3. KBA MetalPrint, www.kba-metalprint.com (2013) 4. W. Wagner, Strömung und Druckverlust, Vogel Buchverlag, 7th edition (2012)