FORM NO. PTZ-786 Supersedes Form No. PTZ-765 Rev. 2 TZPL SERIES Manufactured for Thermal Zone Philadelphia, PA 13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum fins. Includes factory installed low pressure control. Strong, attractive cabinetlouvered design protects the coil from damage. Expansion Valves with Internal Check ValveProvides for quieter refrigerant metering. Demand Defrost Control Non-Cycling Reversing Valve Hot Gas Muffler Service Valves Grille/motor mount for quiet fan operation. Easily accessible control box. Bi-Directional Filter Drier (shipped not installed) Certified and rated under AHRI Standard 240. U.L listed. Accessories/Options Heat Pump Thermostat Warning Light Kit (Model No. RXPX-D01) Low Ambient Control (Model No. RXAD-A08) Outdoor Thermostats (Model No. RXPT-A01, A02, A03 or A04) Heat Pump Monitor (Model No. RXPM-B01) Thermostats and Subbases (Available through the PROSTOCK department) Compressor Time Delay Control (Model No. RXMD-B01) Blower Time Delay Control (Model No. RXMD-C04) RXMD-C04 is not required if the outdoor unit is matched with a Thermal Zone furnace or air handler, or if the furnace or air handler used has a blower off time delay built-in. Sound Enclosure* High Pressure Control (Model No. RXAB-A07) Start Components* *Available through the PROSTOCK department. Applications Thermal Zone remote heat pumps offer comfort and dependability for single, multi-family and light commercial applications.
Model Identification Number TZ P L 3 36 C A THERMAL P = HEAT PUMP L = R-410A 3 = 13 SEER NOMINAL COOLING CAPACITY C = 200/230V - 3 PH - 60 Hz ZONE D = 460V - 5 PH - 60 Hz 36 = 36,000 R [10.55 kw] Y = 575V - 5 PH - 60 Hz 42 = 42,000 R [12.31 kw] 48 = 48,000 R [14.07 kw] 60 = 60,000 R [17.58 kw] DESIGN SERIES Performance Data AHRI Standard Conditions:Three Phase Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. Outdoor Unit TZPL Rev. 8/06/09 336-CA 336-DA Model Numbers Coil and/or Air Handler TZHSL-3617 (RCSL-H*3617) ➀ TCFL-H*3617 -Z92UP603TA TCFL-H*3621 -Z92UP603TA TZHLL-3617 (RCSL-H*3617) TZHSL-3617 (RCSL-H*3617) ➀ TCFL-H*3617 -Z92UP603TA TCFL-H*3621 -Z92UP603TA TZHLL-3617 (RCSL-H*3617) Total Capacity 34,800 35,400 35,000 34,800 35,400 35,200 35,600 35,000 34,800 35,400 35,000 34,800 35,400 35,200 35,600 35,000 AHRI Cooling Performance 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35.0 C] DB Sens. 25,350 [7.4] 24,350 [7.1] 27,150 24,350 [7.1] 27,150 26,550 [7.8] 27,300 25,950 [7.6] 25,350 [7.4] 24,350 [7.1] 27,150 24,350 [7.1] 27,150 26,550 [7.8] 27,300 25,950 [7.6] Latent 8,450 8,250 8,650 8,450 8,250 8,650 8,300 8,450 8,250 8,650 8,450 8,250 8,650 8,300 ➀ Highest sales volume tested combination required by D.O.E. test procedures. EER SEER 11.10 13.00 Snd. Rate db 75 10.95 13.00 75 1 13.00 75 11.40 13.00 75 11.50 13.50 75 10.95 13.00 75 1 13.00 75 11.45 13.50 75 11.55 13.50 75 11.65 13.50 75 12.00 14.00 75 11.10 13.00 75 10.95 13.00 75 1 13.00 75 11.40 13.00 75 11.50 13.50 75 10.95 13.00 75 1 13.00 75 11.45 13.50 75 11.55 13.50 75 11.65 13.50 75 12.00 14.00 75 CFM [L/s] 1,200 [566] 1,070 [507] 1,170 [554] 1,150 [543] 1,070 [507] 1,170 [554] 1,150 [543] 1,200 [566] 1,200 [566] 1,070 [507] 1,170 [554] 1,150 [543] 1,070 [507] 1,170 [554] 1,150 [543] 1,200 [566] AHRI Htg. Performance (70 F [21.0 C] ) 47 F DB/43 F WB [8.5 C/6.0 C] DOE High Temp. 34,000 34,000 3.44 3.46 3.40 3.48 3.50 3.46 3.40 3.48 3.52 3.52 3.44 3.46 3.40 3.48 3.50 3.46 3.40 3.48 3.52 3.52 17 F DB/15 F WB [ 8.5 C/ 9.5 C] DOE Low Temp. 22,000 [6.4] 22,00 [6.4] 2.40 DOE Region IV HSPF 8.50 2.36 9.00 2.40 9.20 2.42 9.25 2.36 9.00 2.42 9.20 2.44 9.30 2.44 9.30 2.46 9.00 2.36 9.00 2.40 9.20 2.42 9.25 2.36 9.00 2.42 9.20 2.44 9.30 2.44 9.30 2.46 9.00 2
Performance Data AHRI Standard Conditions:Three Phase (cont.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. Outdoor Unit TZPL Rev. 8/06/09 342-CA 342-DA 348-CA Model Numbers Coil and/or Air Handler TZHSL-4221 ➀ () () () () TZHSL-4221 ➀ () () () () TZHSL-4821 () ➀ TZHLL-4824 TZHSL-4824 Total Capacity 42,000 [12.3] 42,000 [12.3] 47,500 [13.9] 48,000 [14.1] Sens. 31,050 [9.1] 31,050 [9.1] 31,350 [9.2] 31,050 [9.1] 31,050 [9.1] 31,350 [9.2] 34,950 36,500 [10.7] AHRI Cooling Performance 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35.0 C] DB Latent 10,400 [3.0] 10,450 10,400 [3.0] 10,450 10,400 [3.0] 10,450 10,400 [3.0] 10,450 11,500 [3.4] ➀ Highest sales volume tested combination required by D.O.E. test procedures. EER 11.05 13.00 10.90 13.00 77 77 10.90 SEER Snd. Rate db 13.00 77 11.05 13.00 77 11.25 13.00 77 11.50 14.00 77 CFM [L/s] 1,625 [767] AHRI Htg. Performance (70 F [21.0 C] ) 47 F DB/43 F WB [8.5 C/6.0 C] DOE High Temp. 3.56 3.56 3.62 3.56 3.56 3.62 3.72 17 F DB/15 F WB [ 8.5 C/ 9.5 C] DOE Low Temp. 27,800 27,400 27,800 27,400 27,000 [7.9] 27,800 27,400 27,800 27,400 27,000 [7.9] 2.54 DOE Region IV HSPF 8.50 2.56 9.35 2.60 9.50 2.56 9.35 2.60 9.50 2.66 9.00 2.56 9.35 2.60 9.50 2.56 9.35 2.60 9.50 2.66 9.00 2.60 8.50 2.60 8.50 3
Performance Data AHRI Standard Conditions:Three Phase (cont.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. Outdoor Unit TZPL Rev. 8/06/09 348-DA 348-YA 360-CA 360-DA 360-YA Model Numbers Coil and/or Air Handler TZHSL-4821 () ➀ TZHLL-4824 TZHSL-4824 TZHSL-4821 () ➀ TZHLL-4824 TZHSL-4824 TZHLL-6024 (RCSL-H*6024) ➀ TZHLL-6024 (RCSL-H*6024) ➀ TZHLL-6024 (RCSL-H*6024) ➀ Total Capacity 47,500 [13.9] 48,000 [14.1] 47,500 [13.9] 48,000 [14.1] 58,500 [17.1] 58,500 [17.1] 58,500 [17.1] Sens. 34,950 36,500 [10.7] 34,950 36,500 [10.7] 41,750 41,750 41,750 AHRI Cooling Performance 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35.0 C] DB Latent 11,500 [3.4] 11,500 [3.4] 16,750 [4.9] 16,750 [4.9] 16,750 [4.9] EER 10.90 13.00 10.85 13.00 77 77 11.25 SEER Snd. Rate db 13.00 77 11.25 13.00 77 10.90 ➀ Highest sales volume tested combination required by D.O.E. test procedures. 13.00 77 CFM [L/s] 1,625 [767] 1,625 [767] 1,775 [838] 1,775 [838] 1,775 [838] AHRI Htg. Performance (70 F [21.0 C] ) 47 F DB/43 F WB [8.5 C/6.0 C] DOE High Temp. 56,000 [16.4] 56,000 [16.4] 56,000 [16.4] 3.72 3.72 17 F DB/15 F WB [ 8.5 C/ 9.5 C] DOE Low Temp. 2.60 DOE Region IV HSPF 8.50 2.60 8.50 2.60 8.50 2.60 8.50 2.50 7.70 2.50 7.70 2.50 7.70 4
Electrical and Physical Data: Three Phase ELECTRICAL PHYSICAL Model Compressor Fan Motor Minimum Fuse or HACR Number Phase Outdoor Coil Refrig. Weight Full Load Circuit TZPL Frequency (Hz) Rated Load Locked Rotor Circuit Breaker Per Amperes Ampacity Circuit Voltage (Volts) Amperes Amperes Minimum Maximum Face Area➀ No. (RLA) (LRA) (FLA) Amperes Amperes Amperes Sq. Ft. [m 2 ] Rows CFM [L/s] Shipping Oz. [g] Lbs. [kg] Lbs. [kg] Rev. 8/06/09 336-CA 3-60-208/230 16.3/16.3 73 1.3 22/22 30/30 35/35 16.39 [1.52] 1 3575 [1687] 109 [3090] 215 [97.5] 227 [103] 336-DA 3-60-460 5.8 38 0.6 9 15 15 16.39 [1.52] 1 3575 [1687] 109 [3090] 215 [97.5] 227 [103] 342-CA 3-60-208/230 13.5/13.5 88 1.3 21/21 25/25 35/35 21.85 [2.03] 1 3575 [1687] 150 [4252] 202 [91.6] 214 [97.1] 342-DA 3-60-460 6 44 0.6 9 15 15 21.85 [2.03] 1 3575 [1687] 150 [4252] 202 [91.6] 214 [97.1] 348-CA 3-60-208/230 13.7/13.7 83.1 1.3 21/21 25/25 35/35 21.85 [2.03] 1 3575 [1687] 141 [3997] 205 [93] 217 [98.4] 348-DA 3-60-460 6.2 41 0.6 10 15 15 21.85 [2.03] 1 3575 [1687] 141 [3997] 205 [93] 217 [98.4] 348-YA 3-60-575 4.8 33 0.5 8 15 15 21.85 [2.03] 1 3575 [1687] 141 [3997] 205 [93] 217 [98.4] 360-CA 3-60-208/230 15.6/15.6 110 1.3 24/24 30/30 40/40 21.85 [2.03] 1 3575 [1687] 228 [6464] 209 [94.8] 221 [100.2] 360-DA 3-60-460 7.8 52 0.6 12 15 15 21.85 [2.03] 1 3575 [1687] 228 [6464] 209 [94.8] 221 [100.2] 360-YA 3-60-575 5.8 38.9 0.5 9 15 15 21.85 [2.03] 1 3575 [1687] 228 [6464] 209 [94.8] 221 [100.2] NOTES: ➀ 20 Fins per inch. 5
Unit Dimensions W L H SEE DETAIL A Model Number TZPL Height H (Inches) [mm] Length L (Inches) [mm] Width W (Inches) [mm] 36/42/48/60 35 3 /8 [898.53] 31 5 /8 [803.27] 31 5 /8 [803.27] 6
Heat Pump Refrigerant Line Size Information System Capacity 3 Ton 3 1 /2 Ton 4 Ton 5 Ton Liquid Line Connection Size (Inch I.D.) [mm] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] NOTES: *Standard line size N/A = Application not recommended. Liquid Line Size (R-22) Line Size Outdoor Unit Above or Below Coil (Heat Pumps Only) (Inch O.D.) Total Equivalent LengthFeet [m] [mm] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72] Maximum Vertical SeparationFeet [m] 5/16 [7.94] 25 [7.62] 15 [4.57] 4 [1.22] N/A N/A N/A 3/8* [9.53] 25 [7.62] 30 [9.14] 26 [7.92] 23 [7.01] 19 [5.79] 16 [4.88] 5/16 [7.94] 25 [7.62] 17 [5.18] 2 [0.61] N/A N/A N/A 3/8* [9.53] 25 [7.62] 37 [11.28] 32 [9.75] 28 [8.53] 23 [7.01] 18 [5.49] 3/8* [9.53] 25 [7.62] 33 [10.06] 27 [8.23] 21 [6.40] 15 [4.57] 9 [2.74] 1/2 [12.7] 25 [7.62] 43 [13.11] 42 [12.80] 40 [12.19] 39 [11.89] 38 [11.58] 3/8* [9.53] 25 [7.62] 25 [7.62] 17 [5.18] 8 [2.44] 0 [10.67] N/A 1/2 [12.7] 25 [7.62] 39 [11.89] 37 [11.28] 36 [10.97] 34 [10.36] 32 [9.75] 25' [7.62] 50' [15.24] 100' [30.48] 150' [45.72] Standard Standard Standard Standard Suction Line Length/Size versus Capacity Multiplier (R-22) Unit Size 3 Ton 3 1 /2 Ton 4 Ton 5 Ton Suction Line Connection Size Suction Line Feet [m] NOTES: *Standard line size N/A = Line size not recommended due to inadequate oil return. 3/4" [19.05 mm] O.D. Opt. 7/8" [22.23 mm] O.D. Std.*.95.93.94 7/8" [22.23 mm] I.D. 3/4" [19.05 mm] O.D. Opt. 7/8" [22.23 mm] O.D. Std.* 1 1 /8" [28.58 mm] O.D. Opt..97.93.92.94 7/8" [22.23 mm] O.D. Opt. 1 1 /8" [28.58 mm] O.D. Std.*.95.93.97.95.93 7
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. GENERAL TERMS OF LIMITED WARRANTY Thermal Zone will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See the Thermal Zone Warranty Card. Condenser Coil leaks caused by factory defects...five (5) Years Compressor...Five (5) Years Any Other Part...Five (5) Years Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. In keeping with its policy of continuous progress and product improvement, the right is reserved to make changes without notice. PRINTED IN U.S.A. 6-10 DC FORM NO. PTZ-786 Supersedes Form No. PTZ-786