Standard response. elo sprinklers

Similar documents
STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS

quick response Sprinkler 105a October 25, 2010

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

standard response large orifice dry

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

standard response/ quick response extended coverage

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers

Microfast quick response Fusible element hsw sprinkler

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

standard response Fusible Link Upright sprinkler VK204 (K8.0)

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

TECHNICAL DATA OBSOLETE

standard response fusible link sidewall sprinkler VK112 (K5.6)

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

esfr dry pendent sprinkler Vk502 (k14.0)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

microfast sr/qr extended coverage pendent sprinkler

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

esfr dry pendent sprinkler Vk501 (k14.0)

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

microfast quick response Pendent sprinkler VK302 (K5.6)

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

December 14, 2015 Page 1 of 7 TECHNICAL DATA

micromatic standard response Upright sprinkler VK100 (K5.6)

micromatic Standard response Horizontal Sidewall sprinkler

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

STANDARD/quick. Sprinkler 42o. August 8, 2011

standard response elo upright sprinkler

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

standard response elo upright and pendent sprinklers (storage-density/area)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

micromatic Standard response Horizontal Sidewall sprinkler

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

microfast quick response extended coverage hsw sprinkler vk606

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

quick response horizontal sidewall sprinkler vk360 (K8.0)

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

TECHNICAL DATA. Page 1 of 5

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

micromatic standard response stainless steel sprinklers

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

Standard Spray concealed horizontal sidewall sprinkler VK481

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

microfast and microfasthp quick conventional sprinklers

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

sprinkler vk538 (K11.2)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

Transcription:

Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent ELO sprinklers are FM Approved for storage and non-storage applications. In certain FM cold storage installations, the dry ELO sprinklers can provide a design advantage with lower overall water demands. In these applications, the dry ELO must be installed on a wet pipe system, per FM data sheet 8-9. In non-storage applications, when used in dry or preaction systems, the sprinklers are designed to prevent water or condensation from entering the drop nipple before the sprinkler operates. Viking Standard Response Dry Pendent ELO Sprinklers are available in various finishes and temperature ratings to meet design requirements. The optional dry sprinkler boot assembly is intended to slow the exchange of air between the inside and outside of the freezer (or any dry sprinkler installation) to help prevent humidity and temperature differential in the area around the sprinkler. Condensation can lead to ice build-up, which could inhibit sprinkler operation or cause premature operation. If using the insulating boot assemblies included with your sprinklers (optional for installation), follow the installation instructions in this technical data page. Insulating boot assemblies, if used, shall be installed on smooth, flat, and clean surfaces. There are specific installation situations, as with corrugated ceiling panels, where alternative penetration sealing methods may be utilized. For additional information contact Viking Technical Services. 2. LISTINGS AND APPROVALS FM Approved: Classes 2013 and 2015 Refer to Approval Chart and Design Criteria on page 4 for FM Approval requirements that must be followed. Thread Size 1-1/4 NPT (32 mm BSP) K-Factor 11.2 (161.3 Metric) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1-1/4 NPT or 32 mm BSP Nominal K-Factor: 11.2 U.S. (161.3 metric**) for all listed and approved lengths. * FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). **Metric K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass Fusible Link Assembly: Beryllium Nickel, coated with Polyurethane Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C36000 Pip Cap Adapter: Brass UNS-C36000 Orifice: Brass UNS-C36000 Tube: ERW Hydraulic Steel Tube Barrel End and Threads: QM Brass Support (Internal): QM Brass Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Replaces Form No. F_040815 Rev 15.1 (Revised Finishes, Approval Chart and Ordering Information)

Page 2 of 9 Boot Assemblies (optional): Seal: Neoprene/EPDM/SBR Over Seal Ring and Under Seal Ring: Cold Rolled Steel Finish: White Paint #10 Screws: Stainless Steel Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 Ordering Information: (Also refer to the current Viking price list.) Order Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ( A dimension) to sprinkler base part number. Order in a specific length noted as the A dimension (see Figures 2 through 4). The A dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 12 to 48 (305 mm to 1,22 m), to be ordered in 6 (153 mm) increments, for adjustable standard, adjustable recessed, and plain barrel styles. NOTE: These sprinklers are only available to order in 6 (153 mm) increments. Finish Suffix: Brass = A (Plain Barrel version only), Chrome = F, and White Polyester = M-/W Temperature Suffix ( F/ C): 165 /74 = C, 205 /96 = E, 280 /138 = G For example, sprinkler VK548 with 1-1/4 NPT Threads, a Chrome finish and a 165 F/74 C temperature rating, and A length of 12 = Part No. 19833FC12. The Adjustable Recessed version is not available in 280 F (138 C) Available Finishes and Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. For Recessed Adjustable sprinklers, use the wrench for recessed sprinklers: Part No. 19748 B. For Plain Barrel and Standard Adjustable sprinklers use a pipe wrench applied on the inlet housing. A ½ ratchet is required (not available from Viking). Replacement Escutcheons: A. Adjustable Standard Dry Escutcheon: Base Part No. 19730 B. Recessed Dry Escutcheon Cup: Base Part No. 19728 4. Installation Refer to the applicable FM Loss Prevention data sheets. Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to suppress the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability The Viking Standard Response Dry Pendent Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly.

Page 3 of 9 Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Frame Paint Color Ordinary 165 F (74 C) 100 F (38 C) None Intermediate 205 F (96 C) 150 F (65 C) White High 3 280 F (138 C) 225 F (107 C) Blue Sprinkler Finishes: Brass 4, Chrome, and White Polyester 1 The sprinkler temperature rating is stamped on the deflector. Footnotes 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The Adjustable Recessed version is not available with High Temperature rating. 4 Only the Plain Barrel version is available in Brass. Step 1: Carefully slide the wrench sideways around the sprinkler deflector. Wrench 19748** must be used for installing recessed dry sprinklers. **A 1/2 ratchet is required (not available from Viking). Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 1: Wrench 19748 for Adjustable Recessed Dry Pendent Sprinklers

Page 4 of 9 Sprinkler Base Part No. 1 SIN Style Approval Chart FM Standard Response ELO Dry Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Thread Size Nominal K-Factor 2 Order Length Increment FM Approvals 4 (Refer also to Design Criteria below.) NPT BSP U.S. Metric 3 Inches mm 19830 Plain 1-1/4 -- 11.2 -- 6 -- A1 VK544 19831 Barrel -- 32 mm -- 161.3 -- 153 A1 19835 VK545 Adjustable 1-1/4 -- 11.2 -- 6 -- B2 19836 Recessed -- 32 mm -- 161.3 -- 153 B2 19840 VK546 Adjustable 1-1/4 -- 11.2 -- 6 -- A3 19841 Standard -- 32 mm 161.3 -- 153 A3 Approved Temperature Ratings A - 165 F (74 C), 205 F (96 C) and 280 F (138 C) B - 165 F (74 C) and 205 F (96 C) Approved Finishes and A Dimensions 1 - Brass, Chrome, and White Polyester, with A dimensions 12 to 48 (305 to 1,22 m) 2 - Chrome and White Polyester, with A dimensions 12 to 48 (305 to 1,22 m) 3 - Chrome, and White Polyester iwth a Chrome or White Polyester Sleeve and Escutcheon with A dimensions 12 to 48 (305 to 1,22 m) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ( A Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 4 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. FM Approval Requirements: DESIGN CRITERIA - FM (Also refer to Approval Chart above.) ELO Dry Pendent Sprinklers in the Approval Chart above are FM Approved as standard response, standard spray storage sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Page 5 of 9 For A Dimension: 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 6 (153 mm) increment between 12 and 48 (305 mm and 1,22 m). 3. Per A dimension, the deflector will be located approximately 4 (102 mm) below the ceiling. 1-1/4 (32 mm) tee 1-1/4 NPT (32 mm) A Minimum ceiling opening diamter: 2 (51 mm) Maximum ceiling opening diameter: 2-3/8 (61 mm) Finished ceiling 13/16 (21 mm) Sleeve finish matches escutcheon 1-7/8 (48 mm) diameter 3-7/8 (99 mm) Deflector at minimum distance below ceiling. NOTE: To locate the deflector at the minimum distance below the ceiling, with no upward adjustment available, order the dry pendent sprinkler as per the A dimension. 4 (102 mm) Minimum Deflector at maximum distance below ceiling. NOTE: To locate the deflector at the maximum distance below the ceiling, with no downward adjustment available, order the dry pendent sprinkler 6 (153 mm) longer than the A dimension. 10 (254 mm) Maximum Figure 2: Adjustable Standard Dry Pendent Sprinkler

Page 6 of 9 For A Dimension: 1. Determine the distance from the face of the tee to the finished ceiling. 2. For adjustable recessed the A dimension must be a minimum of 12 (305 mm) up to 48 (1,22 m) in 6 (153 mm) increments. 1-1/4 (32 mm) tee 1-1/4 NPT (32 mm) Minimum ceiling opening diameter: 2-5/8 (67 mm) Maximum ceiling opening diameter: 3 (77 mm) NOTE: The sprinkler will be recessed approximately 5/16 (8 mm) above the finished ceiling with 5/8 (16 mm) vertical adjustment available. Adjustment: 5/16 (8 mm) Minimum: 1 (26 mm) Maximum: 1-5/8 (43 mm) Finished ceiling 3-5/8 (80 mm) Figure 3: Adjustable Recessed Dry Pendent Sprinkler

Page 7 of 9 For A Dimension: 1. Determine the distance from the face of the tee to the base of the sprinkler. 2. Round up to the next higher 6 (153 mm) increment between 12 and 48 (305 mm and 1,22 m) 1-1/4 (32 mm) tee 1-1/4 NPT (32 mm) Outside diamter: 1-11/16 (43 mm) 2-1/16 (53 mm) Figure 4: Plain Barrel Dry Pendent Sprinkler

Page 8 of 9 Ambient Temperature of Protected Area* at the Discharge End of the Sprinkler Exposed Barrel Ambient Temperature 40 F(4 C) Exposed Minimum Barrel Length** Face of Tee to Top of Ceiling In. (mm) 40 ºF(4 ºC) 0 0 0 30 ºF(-4 ºC) 20 ºF(-7 ºC) 10 ºF(-12 ºC) 0 ºF(-18 ºC) -10 ºF(-23 ºC) 0 4 (102) 8 (203) 1 (26) 12 (305) 3 (76) 14 (356) 50 F(10 C) 60 F(16 C) 0 0 0 0 4 (102) 0 0 1 (26) Install 1-1/4 NPT (32 mm BSP) threaded end of dry pendent sprinkler into the 1-1/4 NPT (32 mm BSP) outlet of a malleable iron tee fitting per ANSI B 16.3 (Class 150) or cast iron threaded tee fitting per ANSI 16.4 (Class 125) Exposed barrel Minimum ceiling opening diameter: 2 (51 mm) Maximum ceiling opening diameter: 2-3/8 (61 mm) -20 ºF(-29 ºC) -30 ºF(-34 ºC) -40 ºF(-40 ºC) -50 ºF(-46 ºC) -60 ºF(-51 ºC) 14 (356) 16 (406) 18 (457) 20 (508) 20 (508) 6 (152) 8 (203) 8 (203) 10 (254) 10 (254) 3 (76) 4 (102) 4 (102) 6 (152) 6 (152) Ceiling 1-7/8 (48 mm) diameter (Protected area) 3-7/8 (99 mm) 13/16 (21 mm) Sleeve finish matches escutcheon Seal the clearance space around the sprinkler to avoid leakage of air into the protected area and consequent formation of condensate around the frame, which could inhibit operation or cause premature operation. Refer to Figure 6 below. If humidity and temperature differential causes condensation on the exposed dry sprinkler, consider wrapping the exposed barrel with insulation, foam insulating tape, or equivalent. Deflector at minimum distance below ceiling. NOTE: To locate the deflector at the minimum distance below the ceiling, with no upward adjustment available, order the dry pendent as per the A dimension. 4 (102 mm) Minimum NOTE: To locate the deflector at the maximum distance below the ceiling, with no downward adjustment available, order the dry pendent sprinkler 6 (153 mm) longer than the A dimension. 10 (254 mm) Maximum Deflector at maximum distance below ceiling. *The protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. **The minimum required barrel length is not the same as the A dimension. Refer to Figures 2-4 for the A dimension. NOTE: Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 5: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is shown)

Page 9 of 9 Boot assembly (optional) Part No. 19330M/W (or equivalent method) Clearance opening Insulated ceiling Dry Sprinkler Seal on the Exterior of the ceiling Seal Insulated ceiling Dry Sprinkler Seal Within the ceiling Figure 6: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown)