Amec Foster Wheeler- Fired Heater Division

Similar documents
Coker Heaters Performance Improvement. Don Tran LyondellBasell, Houston Refinery & Ashutosh Garg Furnace Improvements Sugar Land, TX

Burners Flares Incinerators Vapor Combustion

High tube metal temperatures

Fired Heaters Key to Efficient Operation of Refineries and Petrochemicals

OIL AND GAS INDUSTRY

LOW-NOX BURNER RETROFIT CHALLENGE

Shale Oils Designing for Improved Crude Preheat Train Reliability and Performance

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

Improving Fired Heaters Reliability using Inclined Firing Technology

2007 KBC Advanced Technologies plc. All Rights Reserved.

THE WORLD S FIRST FLAMELESS CRUDE HEATER

HYDROCARBONENGINEERING June June 2015

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces

Revamp Fired Heaters to Increase Capacity Use these guidelines to ensure a successful project

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

The World s First Flameless Crude Heater

Fired Heater Flooding

KBC Petro-SIM Design Tools Integrated Equipment Operations. Al Shelton - KBC

BHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy

The following report is prepared and published by:

Kolmetz Handbook of Process Equipment Design REFINERY FURNACE DESIGN, SIZING AND TROUBLESHOOTING (ENGINEERING DESIGN GUIDELINE

CASE STUDY ON EFFICIENCY & AVAILABILITY DETERIORATION IN AN AFBC BOILER

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS

MaxiCoking Technology Breakthrough Technology for Improved Existing Delayed Coker Performance

Flameless Technology Demonstration Heater

INCREASED RELIABILITY / REDUCED RISK BY APPLYING INTELLIGENT PIGGING TECHNOLOGY TO INSPECT COILS IN PROCESS HEATERS

Boiler Basics. Design and operation

Document Code: 1 (15) Issuing date: Status:

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

BALANCED FLOW METER PLATE APPLICATIONS

A Newsletter published by ESI. The Steam and Power SPECIAL FORCES

Efficiency & Savings through On-Line Chemical Cleaning

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

INDUSTRIAL WATERTUBE BOILERS

Tube Skin Temperature Sensors

Overview of Gas Range Types

HOW TO BOOST THE PERFORMANCE OF FIRED HEATERS

Fired heaters for refineries and petrochemical plants. Presentation of our Projects

Waste/Multi Oil Boilers from Flexiheat

A TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS

A Summary of Almost 50 Years of Glass Furnace Preheating

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

The world s standard in efficiency. CBEX FIRETUBE

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

QuestIntegrity.com CHALLENGE CONVENTION

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

SHELL AND TUBE HEAT EXCHANGER (STHE) - part b

B - BEST O - ORIGINAL. R - Renown. N - Name. I n H e a t e r s

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

Ohio Energy. Workshop HH. Strategies & Technologies to Improve the Boiler Room Efficiency. Wednesday, February 21, p.m. to 3:15 p.m.

Zeeco recently had the opportunity

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Steam Temperature. HanPHI Catches at KNPC: Naphtha Unit. Early Warnings Generated by HanPHI

CHIMNEY INSTALLATION. Technical Bulletin #1

On-Load Boiler Cleaning with Steam

The key element for your process

HOT AIR AIR HEATER. (888) Copyright 2010 Paragon Airheater Technologies, All Right Reserved

Thermal Fluid Heaters

Vacuum distillation APPLICATION REPORT

Originators of the Flexible Water Tube design

Burner Comparisons. Typical Competitor s Burner

OPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

PUSHING THE LIMITS OF WHAT IS POSSIBLE

G215 G315 Cast Iron Residential Boilers

Diocese of Cleveland Facilities Services Corporation

WATER-TUBE POOL HEATERS

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

Importance of a Draught Regulator

Boiler Draft Equipment

Raypak Residential Products

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

1.1 This section applies to air handling units for HVAC Systems.

On-Load Boiler Cleaning with Steam

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

City of Duluth Festival Center 04/25

SPRAY COOLING BOF HOODS by David A. Lehr, Senior Engineer UCAR Carbon Company Inc., Parma, OH

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Boiler MACT Webinar Q/A

WATER-TUBE POOL HEATERS

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS

G315/6 Cast Iron Boiler

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Fire Patterns. Introduction. Skills Objectives. Fire Effects and Fire Patterns (2 of 2) 12/20/ Knowledge Objectives

Efficient Steam System Design

PIP PNE00004 Steam Trap Guidelines

PACKAGED COMMERCIAL WATERTUBE BOILERS

High Performance Diesel Fueled Cabin Heater. Abstract

DIVISION FINNED WATER-TUBE WATER HEATERS

Engineering Standard. Saudi Aramco DeskTop Standards

Refining and Petrochemical Heater trouble shooting

G124X - G234X - G334X Atmospheric Gas Boilers

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

A CASE STUDY ON BOILER TUBE FAILURE AT JPL

9600 SERIES GAS FURNACES napoleonheatingandcooling.com

DESIGN PHILOSOPHY. Indirect bath heaters have a wide variety of successful applications in the oil and gas

Transcription:

Amec Foster Wheeler 2016

Amec Foster Wheeler- Fired Heater Division Amec Foster Wheeler 2016

Amec Foster Wheeler Delayed Coker Heater - Best Practices Patrick Bernhagen Director of Sales

Agenda 1. Overview Amec Foster Wheeler in delayed coking 2. Fired Heater best practices 3. Delayed coker heater best practices 4. When it all comes together 5. Questions 4

Industry recognition and acceptance Delayed coker heaters since 1959 150 delayed coker heaters 86 Terrace Wall delayed coker heaters 66 delayed coker heaters in last 10 years 12 delayed coker heaters under contract 5

Delayed coking and the fired heater Amec Foster Wheeler has more than half the licensed delayed coking unit market share in the world Alignment of the process licensor and the proprietary heater supplier provides the client the focused attention to providing the best heater design to the process requirements Amec Foster Wheeler Fired Heater Division has the largest market share of delayed coker heaters in the world with over 150 heaters since 1959 We are the largest supplier of the highly reliable double fired coker heater with our trademark design the Terrace Wall delayed coker heater 6

Best practices Fired heaters general 7

Fired heater DCS monitoring Data to bring into DCS Arch draft alarm high as well as low Stack damper setting Radiant section O 2 readings preferably several in firebox Burner pressure-burner test set points Combustible analyzers Process conditions in/out (and crossover) TSTC APH Skin TIs Damper settings - fans, bypass, stack Air and flue gas temperatures/pressures 8

Fired heater best practices Proper draft profile Excess air / oxygen in flue gas Tramp air air infiltration Burner selection Convection section monitoring Air preheat monitoring 9

Draft monitoring Draft should be measured under the first row of convection tubes High draft causes more air leakage and lowers the heater s efficiency, the higher the draft higher the leakage High draft changes the burner flame pattern-longer flames High draft can cause a heater to be firing/flue gas limited Low draft could mean a positive and dangerous fire box, especially the sight doors 10

Oxygen monitoring Fired heaters are designed for 10-25% excess air that translates to 2-5% oxygen in the flue gases First the O 2 must be measured in the radiant section and not the stack- air infiltration will distort the true reading Higher O 2 transfers duty to the convection section and raises the crossover temperature from convection to radiant section. At higher capacities, it can be a benefit to unload the radiant flux It lowers the bridgewall temperature which reduces fouling/coking tendencies Higher O 2 causes higher firing of the burners If the burners are near their operating limits higher O 2 will increase flame stability issues 11

Tramp air infiltration - oxygen readings Air infiltration causes erroneous O 2 readings that after safe operation of the heater. Air infiltration causes efficiency losses. 160,000 Heat Loss - 1 Square Inch Area 140,000 120,000 Heat Loss Btu/hr 100,000 80,000 60,000 40,000 Firebox Losses Convection Losses Hot Duct Losses Stack Losses 20,000-1 2 3 4 5 Draft inches W.C. 12

Tramp air infiltration - fan loadings Tramp air can load up ID fans and impact abilities to meet capacity requirements 16,000 Air Leakage by area size 14,000 12,000 10,000 flow (lb/hr) 8,000 6,000 4,000 6" x 6" 4" x 4" 2" x 2" 1" X 1" 2,000-0.10 0.50 1.00 2.00 5.00 Draft inches W.C. 13

Burner selection Sizing and spacing requirements of API standards Type selected for the heater geometry, draft, fuel & combustion air conditions Emissions require extensive coordination with burner vendors A distinct flame pattern is usually desired by the heater designerheight and spread of the flame Burner testing to verify above, it also sets high and low pressure alarm points for proper monitoring 14

Poor burner pattern Draft too high or too low? O 2 too high or too low? Burner registers opened or closed? Burner tips plugged? Considerably different fuels? High fuel pressure? Flame impingement? Burners shut off? Air preheat temperature? 15

Convection section monitoring 150ºF (85 C) approach temperature (flue gas out to process in) is a rule of thumb design benchmark More means a fouled convection Steam generation lowers this slightly Draft across the convection section should be ~0.3-0.5 7.5-12.5mm) WC Higher if fouling in convection tube s extended surface Or if increased flue gas flow rate due to high O2/ air leakage Check crossover temperatures between passes for fouling or blockage Thermally scan convection wall for refractory damage Measure draft under first row of tubes instead of radiant arch 16

Air preheat system monitoring APH systems may have steam-air preheat coils, cold air bypass ducts, skin TI s & fan dampers to monitor and control heater efficiency Steam-air coils assist in cold weather conditions to keep APH surfaces above dew point temperatures- monitor with the skin TIs Cold air bypasses can also assist in cold weather but should normally be closed- loss of efficiency and impacts ID fan operations Operations with the cold air bypass opened causes higher burner firing due to colder air and more volume in ID fan due to warmer and more flue gas Pressure drop across APH systems can occur it is best to benchmark the pressure profile on start up Thermally scan ducts for refractory damage should be planned prior to any shutdown 17

Best practices Delayed coker heaters 18

Delayed coker heater best practices Srini s rules for coker heater design Single- and double-fired designs Oil firing India market Vintage versus current practices 19

Srini s rules for coker heater design Individual pass control and firing required High cold oil velocities- 6-7 fps (1.8 m/s) minimum Generous fire box dimensions Proper velocity medium injection rate Minimum residence times above the cracking temperature Optimum heat flux with no mal-distribution Constantly rising temperature profile (no dead zones) Symmetrical pass arrangement and connected piping Uniform heat flux= long runs Cold oil velocity= velocity at 60F 20

Individual pass control and firing DCU heaters are controlled differently than refinery heaters - the flow rate per pass is set and the firing is adjusted for the critical outlet conditions Completely isolated passes allow for different operations on each pass without impacting adjacent passes to meet the outlet conditions In normal operation, a faster coking pass can be adjusted to continue operations until a spall can be planned For proper spalling operations this isolation is the key - it allows a high degree of firing control and TMT control to get a good spall There is an negative economic impact on plant operations if multiple passes must be removed for a spalling operation Amec Foster Wheeler has designed this way for decades and continues to design in this fashion whether a single- or double-fired coker heater 21

Single- versus double-fired design Relative Fouling Index by Deposit Weight (FIDW) 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 AREA 1 Readily fouling, Difficult feed. Advanced design heater required. AREA 2 Borderline feed tending towards unacceptable fouling. Advanced design heater recommended or conservative conventional design with on line spalling required. AREA 3 Acceptable fouling with conventional heater design. 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 22 Relative Fouling Index by Temperature Difference (FITD)

Single- versus double-firing As seen there are overlaps with conservative single fired designs and double fired designs Oil firing requires a single fired design as there are burner selection and operation issues on double fired designs due to the sizes A single fired design can achieve good run lengths with: Generous firebox dimensions Proper flux and COV selection Optimum burner sizing and spacing Attention to sootblower design Proper APH system selection Double firing can be used in all cases following Srini s rules 23

Single fired heaters Peak heat flux is 80% above average heat flux 24

Double fired heaters Peak heat flux is only 20% above average heat flux 25

Indian Delayed Coker Heater Due to the oil firing requirements in most plants - only single-fired delayed coker heaters are provided As indicated in the previous graph- conservative single fired designs can provide good and reasonable run lengths Generous firebox sizing and optimum heat flux with no maldistribution are key design rules for these heaters This classic delayed coker heater design has been improved upon over the years and incorporated in recent heaters Bridgewalls included in radiant sections for individual pass firing Set up for on-line spalling and off line pigging A comparison of vintage versus current practices follows 26

Vintage single-fired coker heater Single fired with bridgewall Roof tubes - sometimes double row Mule ears both ends - in header boxes Angled burner firing Multiple tube diameters in radiant section 6 fps (1.8 mps) COV Oil & gas firing 27

Current single-fired units oil firing No roof tubes Straight up burner firing Single size radiant tubes Contoured plug headers one end Heavy back wall return bends one end Bridgewalls for individual pass firing COV 6 fps (1.8 mps) minimum Oil or gas burner firing 28

Velocity injection Vintage units Steam used as medium Injection rate - 1-2% by weight Injection sites Inlet Crossover ~4 th tube from outlet Current units Steam or condensate medium Condensate preferred as its use in spalling operations provides better spalls Injection rate - variable versus capacity - curve is provided Injection sites Inlet Crossover 29

Velocity injection Velocity mediums - steam or condensate are determined by the licensor and are unique for each heater design Velocity medium rates have gone from 1-2% to a variable rate used currently dependent on % of design capacity The licensor should provide an appropriate curve of the velocity medium injection rates and this should be programmed into the control system Injection sites for the medium where at inlet, crossover and in the radiant section; all injection medium now is injected before the convection section and a crossover connection is provided and rarely used; the radiant connection has been eliminated This same medium can be used for on-line spalling which leads to condensate being preferred in many case With high inlet pressures condensate may be required if HP steam is not available 30

Velocity medium injection rate vs feed rate 50% 100% 31

Tube design Vintage units 5Cr or 9Cr Calculated TMT with a margin - ~1200F (650C) Pump shut off pressure ~500-600 psig (35-42 kg/cm2) Pipe schedule thicknesses Current units 9 Cr-1Mo Maximum temperature of material - 1300F (705C) Pump shut off pressure ~800-900 psig (55-65 kg/cm2) Minimum wall tubing specified thicknesses 32

Mule ear plug headers - vintage designs Plug headers both ends of the tube Contained in radiant header boxes Rolled joint attachment to the tubes Leaked but allowed mechanical cleaning access to the tube ID 33

Contour plug header current designs Plug headers one or both ends of the tube Contained in radiant header boxes Welded joint attachment to the tubes Leakage minimizes but allowed mechanical cleaning access to the tube ID - used when fully coked off 34

Return bends Current design has heavy wall cast return bends on one end of the tube Cast returns are selected to maintain the tube ID throughout the bend Intermediate vintage return bends used heavier sch. thickness but caused higher velocities with smaller ID 35

Radiant header boxes - a continued feature Plug headers require header boxes Return bends in header boxes operate at fluid temperature not at tube TMT a benefit for the erosive nature of spalling The lower temperatures translate to higher stresses in the material since the return bends are still designed for firebox conditions A new Amec Foster Wheeler patent to cover SS tubes in the firebox but the more erosion/wear resistant 9Cr-1Mo return bends in header boxes 36

Decoking methods Vintage Steam-air decoking Off line execution by owner s staff Mechanical Off line execution by owner or outside contractor Current Spalling On line by owner s staff Pigging Off line by contractors Steam air Off line by owner Mechanical Off line by owner or outside contractor 37

Pigging- developed for inorganic fouling Courtesy of Quest Integrity Pig Smart pigging capability 38

Spalling Steam/condensate sparging with thermal cycling Spalling was a patented process developed in the 1980s Spalling is a reliable method for organic fouling removal on-line with the right procedure Spalling relies on temperature cycling of the tubes to be effective It is an on-line operation so the effluent must be handled by the process downstream of the heater Spalling does not require the heater to be cool to perform It is most effective when the heater is set up with individual passes for isolation and separate burners for each pass for firing control Spalling can be performed by properly trained plant personnel 39

On-line spalling single-fired Rachet effect 40

Online spalling double-fired Clean TMT 41

Best practices Terrace Wall Delayed Coker Heater As presented in Bahrain Refcomm Conference 2015 42

When it all comes together! SATORP Coker Heater presentation Bahrain meeting Terrace Wall coker heater 1 year run without spalling Running at design rates and recycle Design COV (cold oil velocity) Design velocity medium injection rate Design crossover temperature Feed stock same as design basis Fluid properties per design Residence time and cracking as design Coker off gas fuel same as design basis Burners firing at normal rates Burners firing at shop test conditions 43

Q&A 44

Thank you! Patrick Bernhagen patrick.bernhagen@amecfw.com +1 936 448 6323 www.amecfw.com 45

Amec Foster Wheeler 2016