Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Similar documents
Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger REGARD -1 Control System

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Flame 5000 Flame Detection

Dräger REGARD -1 Control System

Dräger PIR 7200 Detection of toxic gases and oxygen

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger REGARD 3900 Series Control System

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger QuadGard Control System

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger PIR 7000 Flammable Gas Detection

The SharpEye 40/40I (IR3) Flame Detection

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger Pac 3500 Single-Gas Detection Device

Dräger Flame 5000 Flame Detection

Dräger REGARD -1 Control System

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger PEX 3000 Flammable Gas Detection

Dräger X-am 2500 Multi-Gas Detector

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

The SharpEye 40/40I (IR3) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection

GS01 (wireless) Detection of flammable gases and vapours

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger X-am 5000 Multi-Gas Detector

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Pac 5500 Single-Gas Detection Device

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger Bump Test Station Calibration and Bump Testing

Dräger X-am 5000 Multi-Gas Detection

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Flame 2100 (UV) Flame Detection

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger X-am 2500 Multi-Gas Detection

Dräger Configuration and Evaluation Software

On-site & Shutdown Safety Service CSE Monitoring

The SharpEye 40/40R (IR) Flame Detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Training Authorised Gas Tester Level 1. Basic Information

Dräger X-zone 5500 Area Monitoring

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Flame 2100 Flame Detection

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger FRT 1000 / ETR 1000 Location Devices

Dräger Bodyguard 1000 Warning Device

Dräger VVP 1000 System Components

Dräger Pac 6000 Single-Gas Detection Device

Training Gas Detection Level 3 Maintenance and Repair

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger Polytron 8310 Stationary gas detector (DSIR)

Tropic 2.0 ultrasonic nebuliser

Dräger Pac 8500 Single-Gas Detection Device

Dräger Pac 8000 Single-Gas Detection Device

Dräger Pac 7000 Single-Gas Detection Device

Dräger Flame 2500 Flame Detection

ST More than the sum of their components GAS DETECTION SYSTEMS

Portable wet chemical extinguishers

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Powder Extinguisher ABC - composite Portable powder extinguishers

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Foam Extinguisher AB - composite Portable foam extinguishers

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Dräger Polytron 7000 Fixed gas detector

Foam Wheeled Extinguisher AB Movable fire extinguishers

Dräger X-zone 5500 Multi-Gas Detection Device

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Oxylog VE300 Emergency & Transport Ventilation

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger X-am 5000 Multi-Gas Detection

Dräger OR Lights Simply good light

Dräger X-zone 5500 Area Monitoring

ST More than the sum of their components GAS DETECTION SYSTEMS

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

VarioVac vacuum regulators Consumables and Accessories

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Transcription:

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours The Dräger Polytron Pulsar 2 is the latest infrared technology in open path gas detection Equipped with all the same functions as the standard Dräger Pulsar, Pulsar 2 is fitted with an ABS moulded cover and is supplied with either a junction box or certified connector to provide complete flexibility during installation ABS moulded cover D-85830-2013 Lens protection cover

02 Dräger Polytron Pulsar 2 Benefits Easy adjustment and commissioning Designed for one man installation and commissioning through use of a hand-held terminal the Pulsar 2 transmitter and receiver can be accurately aligned, gas level zeroed and commissioned with maximum efficiency The factory calibration of the Polytron Pulsar 2 makes manual setting and test gas superfluous System stability The detector is designed so that no fault remains undetected During normal operation, the output signal is between 4 to 20 ma, depending on the measured gas concentration A signal of < 1 ma represents a fault due to a constant beam block or hardware failure requiring immediate attention However, a signal of 2 ma identifies a beam block and will go to fault if this persists for more than 60 minutes The Pulsar will also output a 35 ma signal to indicate pre-warning where the optics may be dirty or miss-aligned During the period which the Pulsar displays Pre-warning it will still detect gas allowing the customer to schedule maintenance on the detector therefore reducing down time With no unrevealed faults, the Pulsar 2 is SIL 2 capable In-built database The receiver logs records and details a report of the last seven working days and a summary of the last 32 weeks These reports contain important information such as measuring values, ie beam block, gas readings, warning signals, signal strength, adjustments, supply voltage and operating temperature Extensive access to data from safe areas The optional Polytron Pulsar Software can provide easy access to configuration, current measured values and the internal data-logger from a non-hazardous area through Digital Communication For large and complex installations, the Pulsar software can allow integration of several devices via the AI5000 Up to 32 AI500's can be multi dropped; therefore allowing access to up to 128 pulsars - useful for planning service and maintenance measures High performance The Pulsar receiver communicates to the transmitter via a digital link which allows the receiver to identify and adjust to fluctuating environmental conditions The microprocessor built into the receiver unit instructs the transmitter unit to increase the flash rate for increased performance and accuracy The Pulsar is immune to influences such as sunlight, gas flares, arc welding or resonance effects due to vibrations of rotating parts, as well as to environmental influences such as mist, drizzle or snow The flash rate is also increased upon the detection of gas to ensure both accuracy and fast response Heated optics Regulated internal lens heaters protect against build up of ice and snow under adverse weather conditions They also prevent condensation on the lenses eliminating interference with the measurement function

Dräger Polytron Pulsar 2 03 Benefits HART-communication The HART-Communication of the Polytron Pulsar allows for digital communication between the explosion-proof and the secure areas Without additional cabling, you can obtain real-time access to the status of individual detectors and to the configuration and historical data of each device Worldwide Approvals The Polytron Pulsar Duct Mount holds a performance approval from FM, and global product approvals including ATEX, IECEx, CSA and UL System Components Dräger REGARD 7000 D-6806-2016 The Dräger REGARD 7000 is a modular and therefore highly expandable analysis system for monitoring various gases and vapours Suitable for gas warning systems with various levels of complexity and numbers of transmitters, the Dräger REGARD 7000 also features exceptional reliability and efficiency An additional benefit is the backward compatibility with the REGARD Dräger REGARD -1 ST-335-2004 The Dräger REGARD -1 is a standalone, self contained single channel control system for the detection of Toxic, Oxygen and Ex hazards The control system is fully configurable for a single input from either a 4 to 20 ma transmitter or a Dräger Polytron SE Ex measuring head

04 Dräger Polytron Pulsar 2 System Components Dräger REGARD 3900 D-27777-2009 The Dräger REGARD 3900 is a standalone, self contained control system for the detection of Toxic, Oxygen and Ex hazards The control system is fully configurable between 1 and 16 channels, depending upon the type and quantity of input/output boards installed Accessories Alignment and test kit ST-977-2001 Alignment kit with hand held terminal, gas test cards and software with case For alignment and function test Order No: 23 50 325 AI500 digital interface ST3531-2003 Digital interface for remote access to up to four Pulsars Order no: 23 50 306

Dräger Polytron Pulsar 2 05 Related Products Dräger Flame 5000 D-49077-2012 The Dräger Flame 5000 is an imaging based explosion proof flame detector This visual flame detection system uses digital image processing and advanced algorithms to process and interpret flame characteristics This principle offers an extended field of view and fewer false alarms Each detector is equipped with a colour CCTV camera Dräger PIR 7000 ST-11659-2007 The Dräger PIR 7000 is an explosion proof point infrared gas detector for continuous monitoring of flammable gases and vapours With its stainless steel SS 316L enclosure and drift-free optics this detector is built for the harshest industrial environments, eg offshore installations Dräger Polytron 5700 IR D-14979-2010 The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive limit (LEL) It uses a high performance infrared Dräger PIR 7000 sensor that will quickly detect most common hydrocarbon gases A 3-wire 4 to 20-mA analogue output with relays makes it compatible with most control systems DrägerSensor IR ST-8821-2005 Upgrade from catalytic bead to infrared technology with ease using the DrägerSensor IR The Sensor IR can replace catalytic ex-sensors (pellistors) from the majority of manufacturers without replacing controllers, cables, junction boxes or control systems

06 Dräger Polytron Pulsar 2 Technical Data Type Explosion proof Open Path gas detector utilizing dual wavelength infrared absorption technic Gases Wide range of hydrocarbons including the alkane series from methane to hexane, propylene, ethanol and methanol Range From 0 to 4 up to 0 to 8 LEL*m Factory calibration Methane or propane, selectable Other hydrocarbon gases on request Operating distance 4 to 60 m, 30 to 120 m or 100 to 200 m, 13 to 197 ft, 98 to 394 ft or 328 to 656 ft separation of transmitter and receiver Signal output Analog Measuring 4 to 20 ma Pre-warning 35 ma, dirty optics or misalignment Beam block 2 ma Fault <1 ma Digital HART ATEX 18 to 30 VDC UL, CSA 18 to 27 VDC Supply Voltage Power Consumption Max 095 A @ 24 V, with full heating and all source lamps operating Response time t95 <2 s Ambient conditions Temperature -40 to +60 C, -40 to +140 F Pressure 800 to 1,100 hpa, 236 to 325 inch Hg Humidity 0 to 100 %RH, non-condensing Enclosure IP66, stainless steel Size (W x H x D, approx) 260 x 340 x 220 mm, 1025" x 133" x 85", each Weight (approx) 6 kg, 122 lbs, each Approvals ATEX II 2GD Ex d [ia] IIC T6/T5, -40 to +40 / +60 C IECEx Ex d [ia] IIC T6/T5, -40 to +40 / +60 C FM/ANSI FM ANSI/FM 6325, ANSI/ISA-12 13-04 DNV A-12526 IEC 60079-29-4 Tested by FM Approvals UL Class I, Div 1, Group C, D CSA, NRTL/C Class I, Div 1, Group C, D Ordering Information Dräger Polytron Pulsar 2 variations by max operating range and approval transmitter and receiver, each fitted with an ABS moulded cover Supplied with EEx e junction box or EEx d certified plug and socket Dräger Polytron Pulsar 2 Accessories Part number Junction Box Dräger Polytron Pulsar 2 ATEX 23 50 298 AI500 Digital Interface Unit for Dräger Polytron Pulsar 2 23 50 306 Dräger Polytron Pulsar 2 Remote Junction Box/HHT Kit 23 50 322 Dräger Polytron Pulsar 2 Alignment Kit, ATEX/CSA 23 50 325 Adapter AI500 to HHT or PC 23 50 326 Dräger Polytron Pulsar 2 PC Software with cable (supports Pulsar, AI500 and HHT) 23 50 327 Attenuator plate AP800 23 50 339 ABS Moulded Cover 23 50 510

Dräger Polytron Pulsar 2 07 Ordering Information Dräger Polytron Pulsar 2 with ABS moulded cover and Ex e certified junction box Part number Dräger Polytron Pulsar 2 ATEX 4 120 m (RX only Ethylene) 23 50 340 Dräger Polytron Pulsar 2 ATEX 100 200 m (RX only Ethylene) 23 50 341 Dräger Polytron Pulsar 2 ATEX 4 60 m (TX only) 23 50 499 Dräger Polytron Pulsar 2 ATEX 30 120 m (TX only) 23 50 500 Dräger Polytron Pulsar 2 ATEX 100 200 m (TX only) 23 50 501 Dräger Polytron Pulsar 2 ATEX 4 120 m (RX only) 23 50 502 Dräger Polytron Pulsar 2 ATEX 100 200 m (RX only) 23 50 503 Dräger Polytron Pulsar 2 with ABS moulded cover and Ex d certified plug and socket connectors Part number Dräger Polytron Pulsar 2 ATEX 4 120 m (RX only Ethylene) 23 50 342 Dräger Polytron Pulsar 2 ATEX 100 200 m (RX only Ethylene) 23 50 343 Dräger Polytron Pulsar 2 ATEX 4 60 m (TX only) 23 50 504 Dräger Polytron Pulsar 2 ATEX 30 120 m (TX only) 23 50 506 Dräger Polytron Pulsar 2 ATEX 100 200 m (TX only) 23 50 507 Dräger Polytron Pulsar 2 ATEX 4 120 m (RX only) 23 50 508 Dräger Polytron Pulsar 2 ATEX 100 200 m (RX only) 23 50 509

90 46 095 1511-3 Communications & Sales Marketing PP LE Printed in Germany Chlorine-free environmentally compatible Subject to modifications 2015 Drägerwerk AG & Co KGaA 08 Dräger Polytron Pulsar 2 Notes Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status CORPORATE HEADQUARTERS REGION DACH REGION MIDDLE EAST, AFRICA Drägerwerk AG & Co KGaA Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom Dräger Safety AG & Co KGaA Branch Office PO Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draegercom REGION EUROPE Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom Locate your Regional Sales Representative at: wwwdraegercom/contact REGION ASIA PACIFIC Draeger Singapore Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asiapacific@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL Complejo Business Park, V tower, 10th floor Panama City Tel +507 377-9100 Fax +507 377-9130 contactcsa@draegercom