MSYS 4490 AC Systems

Similar documents
Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations

Mobile Vendors Bulletin

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003

REQUIREMENTS FOR HOOD PLANS

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

COMMERCIAL KITCHEN FIRE SAFETY

FOUNDATIONS OF MODERN KITCHEN VENTILATION (CKV) DESIGN HANDBOOK

2012 ICC Commercial Kitchen Hoods

2015 ICC Commercial Cooking Systems

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

All the products you need for. Engineered Kitchen Ventilation Systems.

MECHANICAL EXHAUST VENTILATION SYSTEMS FOR RETAIL FOOD FACILITIES. Design, Calculations, and Operational Guidelines

COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Kitchen Ventilation Hood Permit Application

Low Wall Back Shelf Exhaust Canopy

APPLICATION FOR EXEMPTION FROM MECHANICAL VENTILATION

MECHANICAL EXHAUST VENTILATION SYSTEMS Design, Calculations, and Operational Guidelines

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Effective ventilation is necessary for the comfort

Direct Gas-Fired Make-Up Air

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

CHAPTER 5: EXHAUST SYSTEMS

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

The Ultimate in Pizza Baking Variable speed Black granite stone conveyor belt Turbo-Flex Airflow System

Chapter One Commercial Kitchen Fires

Indirect Gas-Fired Make-Up Air

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Modular Supply Make-Up Air Unit

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

MINNESOTA COMMERCIAL KITCHEN

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Notable Changes in the Mechanical Codes

IMC Significant Changes Summary Tier I

Direct Fired Heater Model AD Specification

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Inspection Checklist Mechanical Rough in

SECTION (15833) - HVAC POWER VENTILATORS

EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS

CONTROLLED GOODS AND THE APPLICABLE SAFETY STANDARDS PART I DOMESTIC OR HOUSEHOLD APPLIANCES AND SIMILAR ELECTRICAL APPLIANCES

1.1 This section applies to air handling units for HVAC Systems.

ESPAIR E AIRTM ESPA ESPAIRTM. Kitchen Exhaust Air Treatment System KET Series.

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective

Submittal Data Performance Data Electrical Data

SECTION AIR HANDLING UNIT

FOOD SERVICE EQUIPMENT REBATES

NORDcanopy Kitchen ventilation

GLOBAL FINISHING SOLUTIONS

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Modular Heating & Ventilating Unit Model IGX-HV

Land Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2009

SECTION COMMERCIAL-KITCHEN HOODS

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

Modular Cooking EM Series

2012 International Mechanical Code Significant Changes. About the Significant Changes

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

COHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system.

UNIFORM MECHANICAL CODE SIGNIFICANT CHANGE COMPARISON STUDY

Are you a Quick Service Restaurant? 900XP & 700XP

WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE

Land Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2009

Calgary Fire Department Indoor Special Event Requirements. August calgary.ca /fire call

Commercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems

FEATURES AND BENEFITS

CONTENTS. B. System Design and Performance Requirements

B. System Design and Performance Requirements

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Direct Gas-Fired Make-Up Air Models DG and DGX

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

The Enviro-Clean Air Scrubber keeps the Atmosphere Clear and Creates Clean Air

FRESNO COUNTY HUMAN SERVICES SYSTEM ENVIRONMENTAL HEALTH SYSTEM P.O. Box Fresno, CA Telephone (209)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

KIC Air Curtains. Technical Guide

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

City of Leduc Fire Services Indoor Special Event Requirements

Institutions NUMBER: Food Service Safety And Sanitation

Gas-fired water heaters, volume III, storage water heaters with input ratings above 75,000 Btu per hour, circulating and instantaneous

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

NFPA 101 Life Safety Code Culture change 2012

Union County Vocational - Technical Schools Scotch Plains, New Jersey

A. Codes and Standards that are Standard at the University:

Contents INDEX. TDM Series Indirect Fired Heaters

Gas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Gas-Fired Indoor and Outdoor Duct Furnaces

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Types of Detection. Fusible Link Detection - Most Common

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

READ AND SAVE THESE INSTRUCTIONS Installer: Leave this manual with homeowner.

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Transcription:

MSYS 4490 AC Systems Winter 2015 KITCHEN VENTILATION SYSTEMS By Satwinder Singh 12/02/2015 1 12/02/2015 2 By Satwinder Singh 1

12/02/2015 3 12/02/2015 4 By Satwinder Singh 2

Type I: Types of Hoods used over cooking equipment producing heat and grease laden effluent. Type II: used over non grease producing cooking equipment exhausting heat and condensation. 12/02/2015 5 Type I Canopy Hoods Wall, Single island, Double island Type 1 12/02/2015 6 By Satwinder Singh 3

Type 1 Canopy Hoods 12/02/2015 7 Type 1: Water Wash Hoods 12/02/2015 8 By Satwinder Singh 4

Type II Type II Remove heat, moisture, and odor ridden air from non grease producing appliances Do not contain grease filter banks but rather a duct collar to exhaust the contaminated air. Does not need to be fully welded, instead it can be a standard galvanized duct because there is no grease loading. Flex duct is not allowed for TYPE II hoods 12/02/2015 9 TYPE II Hoods 12/02/2015 10 By Satwinder Singh 5

Hood Certification TYPE I exhaust hoods to bear the Underwriters Laboratory Canada (ULC) label 12/02/2015 11 Classes of Cooking Operation Class 1 Cooking Operation: Class 2 Cooking Operation: Class 3 Cooking Operation: Class 4 Cooking Operation: Class 5 Cooking Operation: Grease laden vapors Steam and heat removal Dwelling units) Self contained No hood 12/02/2015 12 By Satwinder Singh 6

Class 1 Grease Laden Vapors Any cooking process which produces significant smoke or grease laden vapors. Requirements: Full compliance with NFPA 96 (Type I hood) Minimum 50 GPM grease interceptor Mesh filters are not permitted in new installations [NFPA 96, 6.1.3]. It is recommended that mesh filters in existing systems be replaced due to increased fire risk. Example of Equipment: range (burners or hot top), stove, hot plate (gas burner, electric coil or flat top), induction cooker, electric frying pan, conveyor convection oven if used for cooking chicken wings or other bulk meat, oven used for cooking meat, char broiler, wok, fry grill, griddle, salamander, deep fat fryer, pan frying, barbecue, rotisserie, Donair vertical broiler, tilting skillet, braising pan, any equipment recommended to have fire suppression by the manufacturer, any equipment which produces or has been designed by the manufacturer to have the potential to produce comparable amounts of smoke or grease. [NFPA 96, A.10.1.2] 12/02/2015 13 Class 2 Steam and Heat Any cooking equipment or process which produces significant steam or heat but does not produce grease laden vapors. Requirements: Type II hood and exhaust with general HVAC ducting Example of Equipment: Any of the following if they are > 6 kw (20,478 BTU/h)7: closed pizza oven, conveyor pizza oven if used only for pizza or bread, baking oven, coffee maker, coffee roaster, hot dog display heater, pastry oven, popcorn maker, roll warmer, steam reconstitution device, steamer, toaster, warming oven 12/02/2015 14 By Satwinder Singh 7

Class 3 Dwelling Units Any cooking equipment or process where limited smoke and limited greaseladen vapours are produced such as in normal usage in a single family home. This Class of Cooking Operation typically utilizes a domestic range. Requirements: A domestic hood with a grease filter is the required minimum. The exhaust and make up air systems must comply with the requirements for a typical self contained mechanical ventilation system serving only one dwelling unit Example of Equipment: single family usage, a single, four burner domestic range in a Fire Hall, a single, four burner domestic range in an amenity room in a residential building, care home, congregate housing, employee break room or church where there is no cooking that produces grease laden vapours, e.g., used for food warming or baking cakes, a microwave is recommended rather than a range where possible), a homeeconomics classroom in a high school where only domestic cooking is taught domestic range in a Licensed Childcare Facility. a single domestic range used in a showroom that sells non food products, such as a showroom for selling domestic ranges, where the range is used once on the occasional day for a small number of people. Class 3 does not include commercial food operations. 12/02/2015 15 Class 4 Self Contained Cooking equipment listed by an accredited certification organization such as ULC, cul or ETL to ventilate into the room. These devices typically have their own fire suppression and grease filtering systems. Requirements: Comply with the manufacturer s installation, operational and listing requirements. Example of Equipment: Giles Ventless Hood Fryer (previously called Chester Fried Ventless Hood Fryer) Perfect Fryer PFC model series, ventless commercial deep fat fryers Belshaw Donut Robot Fryer with Insider ventless cabinet 12/02/2015 16 By Satwinder Singh 8

Class 5 No Hood Cooking equipment where a hood is not provided. Products from the cooking operation may be removed by the room ventilation. Class 5 does not include cooking procedures which produce significant grease laden vapors, significant steam or significant heat. Requirements: Comply with the manufacturer s installation, operational and listing requirements. Example of Equipment: the following if they are 6 kw: coffee maker, coffee roaster, hot dog display heater, pastry oven, closed pizza oven, baking oven, warming oven, popcorn maker, roll warmer, toaster Pennine grills (for making Pennines, i.e., not for processes which cause grease laden vapours such as grilling or braising meat) microwave oven, crock pot 12/02/2015 17 DESIGN Minimum Exhaust Rate Canopy open on 3 sides Canopy open on 4 sides Medium duty* appliances 80 cfm/sq.ft 125 cfm/sq.ft Heavy duty* appliances 100 cfm/sq.ft 150 cfm/sq.ft Medium Duty cooking appliances include electric discrete element ranges (with or with out oven), electric and gas hot top ranges, electric and gas griddles, electric and gas double sided griddles, electric and gas fryers (including open deep fat fryers, donut fryers, kettle fryers, and pressure fryers), electric and gas pasta cookers, electric and gas conveyor pizza ovens, electric and gas tilting skillets (braising pans) and electric and gas rotisseries. Heavy Duty cooking appliances include electric under fired broilers, electric chain (conveyor) broilers, gas underfired broilers, gas chain (conveyor) broilers, gas open burner ranges (with or with out oven), electric and gas wok ranges, and electric and gas over fired (up right) broilers and salamanders. Note: these requirements are the minimum. The professional engineer is responsible to assure adequate exhaust for capture and containment of the grease laden vapors, 12/02/2015 18 smoke, gas and products of combustion. By Satwinder Singh 9

DESIGN Make up Air Rate Type of make Up Air Unit Make Up Air If not direct fired, min.= 80% If direct fired and openings between kitchen and public area 16 ft 2 90% and 110%. If direct fired and openings between kitchen and public area > 16 ft 2 95.2% and 100% 12/02/2015 19 DESIGN Exhaust Ducts Exhaust duct velocity Required to be 500 fpm and 1800 fpm Type 1 NFPA 96 Compliance Stainless Steel, welded liquid tight construction Type II Standard Duct construction 12/02/2015 20 By Satwinder Singh 10

DESIGN Make Up Air Canopy open on 3 sides Temperature Ductwork Design Must be tempered BCBC 2012 6.2.3.11.(3) 0.1 "WG loss/100 ft Pressurization Ductwork Pressure levels should not exceed negative 0.02 in. wg. Galvanized Sheet Metal Perforated Ceiling Perforated Face supply 12/02/2015 21 Room Pressure 12/02/2015 22 By Satwinder Singh 11

Room Pressure 12/02/2015 23 Room Pressure 12/02/2015 24 By Satwinder Singh 12

Grease Extraction Without proper filtration, grease will: Collect in the exhaust plenum and ducts creating: A fire hazard An increase in the frequency of costly duct cleaning Collect on the fan causing it to become unbalanced and lead to premature failure Create odor in or near the restaurant Collect on the rooftop causing deterioration of roof materials Collect on the rooftop equipment and cooling coils 12/02/2015 25 Filters Baffles Designed to capture grease and drain it into a container Can be removed and cleaned Baffle filters use inertial impaction, which is the principle of the particle s momentum throwing the particle out of the airflow as it changes direction, to remove grease from the airflow. Typical pressure drops for a 9 ft. x 4 ft. hood at 2,050 cfm will be 0.5 0.6 in. wg. 12/02/2015 26 By Satwinder Singh 13

Filters Grease Extractor: Integral part of the ULC listed hoods Series of horizontal baffles that are designed to removed grease and drain to a container. Can be removed and cleaned The use of centrifugal force rather than two dimensional impaction allows the efficiency to be improved without a high penalty in static pressure. Airflow enters the filters louvers and is spun in a chamber until it exits the back of the filter. Grease particles are thrown from the airflow during its helical path. The velocity of the airflow determines how small of a particle can be removed. The static pressure is between a baffle filter and a water wash hood. Typical pressure drops for a 9 ft. x 4 ft. hood at 2050 cfm will be 0.7 0.8 in. wg. 12/02/2015 27 Filters Multi Stage Filter/Extractor: uses a centrifugal type filter as the primary stage of filtration along with a packed bead bed filter as the second stage. Interception is the main filtration mechanism which works by adsorption of grease particles as they come in contact with the packed bead bed. Typical pressure drops for a 9 ft. x 4 ft. hood at 2050 cfm will be 1.1 1.3 in. wg. 12/02/2015 28 By Satwinder Singh 14

Type of Fans Upblast Inline Utility 12/02/2015 29 Uplbast Fans The most common type of kitchen exhaust fan. They use a centrifugal backward inclined fan wheel, are either direct drive or belt driven with an isolated motor, and can be roof or sidewall mounted. Grease drains/traps should be used on the fan to collect grease that has passed through the filtration system and may cause roof damage. A vented curb may be required in heat applications such as kitchen ventilation. Hinged curb cap and cleanout ports allow easy access to the inside of the fan and duct. 12/02/2015 30 By Satwinder Singh 15

Inline Fans Inline exhaust fans use a centrifugal backward inclined fan wheel and are mounted as part of the ductwork, usually inside the building. Access panels are located on the housing allowing disassembly of the fan without removal from the ductwork. These fans are best suited for applications where mounting a fan on the exterior of the building is not possible. Examples would be a high rise building where penetrating multiple floors with ductwork would not be feasible or a building where a fan would detract from its visual appearance. Inline grease fans have an isolated motor, adjustable pulleys, and two grease drain plugs with the capability of being mounted horizontally or vertically. 12/02/2015 31 Utility Fans Utility fans offer a variety of discharge positions and can be mounted inside or outside of the building, offering flexibility with respect to duct design. An isolated motor compartment and adjustable pulleys offer flexible speed adjustment for final system balancing. 12/02/2015 32 By Satwinder Singh 16

Fan Selection Criteria Which fan is suitable for the application? Determine Air Flows Calculate System Pressure Consider Sound Levels Select a fan Each fan has a set of fan curves based on airflow, system resistance, motor power, and fan speed. It is crucial to choose a fan within the limits given by the fan manufacturer on the fan curves. The curve that represents system resistance begins at the origin and has an increasing slope on the fan performance graph. The curve that begins at a higher static pressure at zero airflow and tapers to zero pressure with increasing airflow is the fan performance curve. This is a line of constant fan RPM. To find the correct fan, operating points must fall on the fan performance 12/02/2015 curve to the right of the system resistance curve. 33 Fan Selection Example Given the following information, the table below shows properties of two fans that meet the criteria. However, it has yet to be determined which fan is better for this application. Required Specifications: Upblast Fan, 2500 cfm of airflow, 0.25 in. wg static pressure 12/02/2015 34 By Satwinder Singh 17

Upblast Fan, 2500 cfm of airflow, 0.25 in. wg static pressure 12/02/2015 35 MAKE UP AIR SELECTION UNTEMPERED Not allowed in Canada HEATING: 1. Direct Gas The most common units, especially in the northern half of the United States, are the direct asfired units. These units provide outside air that is usually untempered in the summer months and heated in the fall, winter, and spring months. They have an operating efficiency of nearly 100% because the flame is directly in the airstream. Some efficiency is lost in the combustion process. A temperature sensor is set in the unit to regulate the heating cycle. 2. Direct gas fired units move the air directly over a burner to obtain the desired leaving air temperature. A unit that is running too slowly is likely to introduce unwanted by products into the building airstream. Fortunately, many manufacturers have the ability to operate their units at 70 50% of the total airflow. A modulating damper at the inlet maintains a minimum airflow velocity of 3000 fpm across the burner. It is important to verify the heat and airflow turndown with the manufacturer to prevent costly redesigns. 3. Indirect Gas Similar to direct gas fired, indirect gas fired units also heat the air when needed or otherwise bring in untempered outdoor air during warm months. This process uses a heat exchanger which is 80% efficient. Gas is fired through a clamshell or S tube heat exchanger. Heat is then transferred to the air as it passes over the clamshell or tubes while combustion by products are vented to the outdoors. 4. Steam Coil Air reaches its leaving temperature by flowing over steam heated radiator coils. Steam from a boiler system can be tied into a series of coils in a make up air unit. This allows the use of steam in heating air during cold periods. 5. Hot Water Hot water can be used similar to a steam coil but is uncommon in kitchen applications. 6. Electric Heating Electric heating coils can be placed in a heater control cabinet on a make up air unit to provide heat during cooler periods of the year. However, electric heat can be costly. 12/02/2015 36 By Satwinder Singh 18

MAKE UP AIR SELECTION Criteria 1. Determine required tempering options. If required, decide which type of heating and/or cooling. 2. Determine required supply airflow. 3. Determine external static pressure. 4. Select the proper motor voltage for the application. 12/02/2015 37 General Requirements NFPA 96 1. Use 16 gauge carbon steel or 18 gauge stainless steel (minimum thickness) 2. All joints and seams to be fully welded and liquid tight 3. Ductwork shall lead directly to the building exterior 4. Follow clearance to combustibles 5. Minimum airflow of 500 fpm through ductwork 6. Ductwork shall not be interconnected with any other type of building ductwork 7. To prevent accumulation of grease in horizontal ductwork, cleanout ports are required every 20 feet, and the duct should slope towards the hood 0.25 inches every foot for duct runs under 75 feet. Runs greater than this require a slope of 1 inch per foot. Note: These are only a few of the requirements; NFPA 96 and local codes should be consulted 12/02/2015 38 By Satwinder Singh 19