commercial & industrial electric space heating equipment & controls Electrical Wholesaler Product Guide Valid from 1st February 2011

Similar documents
Product Guide & Price List

Product Guide & Price List

Industrial infrared heater IR

Industrial infrared heater IR For premises with large volumes and high ceilings

HEATXL RVS. Electric Infrared Heater

Manufactured....installed worldwide MADE IN BRITAIN

FLEXEL RADIANT HEATING SYSTEMS

QXD & VECTOR RANGE. this product information has been extracted from. theheatingbook

Manufactured....installed worldwide

Elztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications

Carbon infrared heater IHC

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

THE COMPLETE PRICE GUIDE FLEXEL

Fan heater Panther WALL MOUNTED FAN HEATER

Q-RAD ELECTRIC RADIATOR

Infrared Electric Heaters - General Product Information

CH Series Heavy Duty Metal Sheath Electric Infrared Heater

Commercial Fan Heater

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls

The CAB & DAB Air Curtains

Convector Heater G2CH. 2.0kW. 3 Power settings. Fully adjustable thermostat. Wall mounting option. Illuminated control switch. Fitted with 1.

MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX

OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor (THS-A) EUROPE. The modern, slimline solution for

CASSETTE UNIT. Comfort Circle

FR-A180 FR-A360. Occupancy detector. Use

OUTDOOR HEATING RANGE

Hazardous Area Portable Fan Heater The Bulldog

OUTDOOR HEATING RANGE

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

FLEXEL RADIANT HEATING SYSTEMS

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year.

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

UK PRICE GUIDE. January Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS

SURFACE WARM CEILING HEATERS

Hazardous Area Portable Fan Heater The Bulldog

Energy-efficient heat source provides comfort in large rooms

LUH HORIZONTAL FAN-FORCED UNIT HEATER

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

SHORT WAVE INFRARED PANEL DRYER

The quick and convenient way to heat any room. Generating efficient heat as needed with temporary heaters

CONTENTS. 6 DSCS Series Gas-Fired High-Intensity Patio Heater. 12 DGS Series Filtered Short-Wave Electric Infrared Heater

FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters

Hazardous Area Portable Fan Heater The Bulldog

Elztrip EZ100 Single panel radiant heater for offices, shops etc.

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Comfort Air Curtains with in-built dynamic advertising

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters

Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings!

NEW RANGE OF WARM AIR CURTAINS

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Linergy II. England and Wales Cricket Board, Truro Linergy

EDGE PATIO HEATER. User Manual. English

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

Section 16. Infrared & Fan Heaters

15KW ELECTRIC FAN HEATER

Whats in the box. NS1002-E Installation Guide Rev 1.0

2.8KW ELECTRIC FAN HEATER

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Infrared Heating. Product catalogue INFRARED PANELS. Tel:

Sunhouse SPACE HEATING QUALITY STYLE VALUE

Perimeos. Ceiling Recess. decor. systems

Heating Products M arch 2012

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

RHT RAIL HEATER. Rail & Switch Point Heating System. Pre-Terminated Lengths or Cut-to-Length from the Reel

Radiant heaters - Offices, shops and public premises

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

TECHNICAL DATA AND REFERENCE STANDARDS. Essential electrical data* Resistance at test voltage (V) Insulation resistance (MΩ)

3KW ELECTRIC FAN HEATER

CentaurPlus ZW and HRT4-ZW

5KW ELECTRIC FAN HEATER

30KW ELECTRIC FAN HEATER

User s Manual

Imperial Electric Fires

OPERATING AND MAINTENANCE MANUAL

Revolutionise your smart home at the touch of a button...

Instruction Manual WARNINGS

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

DCS2000 DEMENTIA CARE SYSTEM USER GUIDE. For Software Version 1.2 1

PART NO. COMBUSTION AIR CAP

UK Trade Price List. Sterling CUSTOMER:

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

Commercial Evaporative Cooling

Fan heater Panther Powerful fan heater for large premises

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

Explosion-Proof Forced Air Unit Heater - XGB

Installation, operating and servicing instructions

Safe Heating in Sheltered and Social Housing

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..


Super. Bright. Lumens! Super. Slim!

15. Installation. For 6.2ton and above

NATURAL VENTILATION CONTROL SYSTEMS

Transcription:

commercial & industrial Electrical Wholesaler Product Guide Valid from 1st February 2011 electric space heating equipment & controls 2011

Commercial and In Catalogue Valid from 1st February 2011 The BN Thermic Range is divided into 7 families: Fan Assisted Heaters 700 Series Over door/high Level Heaters 4 CHS Suspended Ceiling Multi-Heater System 8 DSU Destratification Units 15 OUH Industrial Unit Heaters 12 RH Recessed Ceiling Heaters 10 SCH Suspended Ceiling Heaters 6 WHE Compact Heavy Duty Wall Heaters 16 4-16 Convection Heaters BLC Low Level Convector Heaters 17 BLS 110V Convector Heaters 19 SWD Industrial Tubular Heaters 20 17-21 Radiant Heaters CH Ceramic Heaters 28 ESN Black Heat Cassettes 30 HN Halogen Heaters 24 HWP Patio Heaters 22 RP Radiant Ceiling Panels 34 22-35 RL Replacement Lamps 27 Look out for these icons 5 Energy saving products Extended warranty Our extended warranty will cover replacement of a failed component or repair in our factory whichever is appropriate. For UK customers, it will also cover return carriage As a responsible manufacturer BN Thermic has instigated a programme of using recycled and recyclable cardboard in its packaging. In future you can expect to see the Corrugated Recycles logo on the majority of our cardboard boxes. Our new range of super tough tamperproof thermostats - ideal for industrial and public area applications web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

dustrial, Electric Heating and Controls Underfloor Heating EHC Heating Cables 40 EHM Heating Mats 36 LH Heating Film 44 36-47 Mirror Demisters MD Mirror Demister Pads 47 47 Pipe Freeze Protection CCSRJ Self Regulating Cable 48 PGE Pre-terminated Cables 50 48-50 Controls CONTACTORS 59 HARD CASE Tamperproof Thermostats 51 MISCELLANEOUS CONTROLS 58 TIMERS 54 THERMOSTATS 56 51-59 For help in making the right selection for your application contact our Technical Sales Team web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

700 Series High Level Wall or Overdoor Fan Assisted Heaters FAN ASSISTED HEATERS Providing warm inviting commercial premises Smart modern appearance First class whole life value from a product built to the highest possible standard and designed to give many years of trouble free service Low running costs by selecting from a range of control options Typical Applications Overdoor heating in shops and cafes Space heating in a wide variety commercial premises Features Common to all Models Dual function bracket for vertical discharge (overdoor) or angled discharge (general space heating) Attractive white (RAL9010) finish Auto-reset over-temperature protection 1m lead 730 as an overdoor heater 730T wall mounted as Space Heater The complete 700 Series A B Mounting brackets Arrangement A - for Overdoor Heating Arrangement B - for General Space Heating 4 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Controlling the 700 Series 720 2kW Heater and 730 3kW Heater These heaters are generally manually controlled via the panel front rocker switch providing off/heat/fan-only settings. When thermostatic control is required we recommend our tamperproof Hard Case Range (see below). Hard Case thermostats tamperproof design ensures that only authorised personnel can adjust the temperature setting. 730T 3kW Heater with Built-In Thermostat The 730T has a panel front rocker switch providing on/off settings and a built-in electronic thermostat with a panel front adjustment knob. Once energised, the fan will run continuously while the thermostat will monitor the incoming air temperature and adjust the heat output accordingly. 730R 3kW Heater with Remote Mounted Control The 730R has been specifically designed for control using a CS-1 wall-mounted controller (see below). The CS-1 should be positioned in a convenient location and provides on/ off/high heat/low heat/fan-only settings. The 730R has no panel front switches. 745 4.5kW Heater The 745 has a panel front rocker switch with off/half heat/full heat settings. Control by a remote mounted Hard Case Thermostat (see below) is possible but as the heater will draw 20A a suitably rated contactor would be required (see page 59). 760 6kW Heater The 760 has no panel front switches and is generally manually controlled using the required local isolation switch. When thermostatic control is required we recommend our tamperproof Hard Case Range (see below) which can be connected to a rear mounted connector and will switch the heater via the heater s built-in contactor. Hard Case thermostats tamperproof design ensures that only authorised personnel can adjust the temperature setting. 700 Series - Specifications FAN ASSISTED HEATERS Model Volts kw Controls Dimensions (mm) Weight H W D (kg) 720 230 2.0 Heat/Fan-Only 225 635 108 7 730 230 3.0 Heat/Fan-Only 225 635 108 7 730T 230 3.0 Electronic Thermostat 225 635 108 7 730R 230 3.0 Remote (using CS-1) 225 635 108 7 745 230 4.5 Half heat/full heat 225 635 108 9 760 230 6.0 Remote Isolation 225 1105 108 14 Remote Control Devices Model Description Full Details on Page CS-1 Controller for 730R 58 HC-T1 Tamperproof Thermostat 16A 51 HC-D Tamperproof Tool for HC-T1 51 This table only shows the basic HC-T1 Hard Case thermostat. However it is possible that an alternative thermostat from the Hard Case Range may be more suitable for any given installation. Please see page 51 for full details of the Hard Case range. CS-1 HC-T1 HC-D Tamperproof Tool for HC-T1 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 5

FAN ASSISTED HEATERS SCH Fan Assisted Heaters for 600 x 600 Ceiling Grid Providing warm inviting commercial premises Ceiling mounting position allows free use of floor and wall space, an important consideration in retail premises First class whole life value from a product built to the highest possible standard and designed to give many years of trouble free service Low running costs by selecting from a range of control options Specifically designed for quick hassle free installation Typical Applications Shops Changing rooms Entrance areas Features Common to all Models Designed to rest in the T bar of a 600 x 600 suspended ceiling grid Air inlet and outlet through front panel no requirement for air supply from the ceiling void White aluminium egg-crate diffuser Pre-wired to rear mounted terminal enclosure Auto-reset over-temperature protection Insert Depth 210mm Controlling SCH Heaters SCHG-30 3kW Heater The SCHG-30 can be controlled by a CS-1 wall-mounted controller (see opposite page). The CS-1 should be positioned in a convenient location and provides on/off/high heat/low heat/fan-only settings. Where thermostatic control is preferred we recommend our tamperproof Hard Case Range (see opposite page). Hard Case thermostats tamperproof design ensures that only authorised personnel can adjust the temperature setting. SCHG-30E 3kW Heater with Built-In Thermostat The SCHG-30E has a built-in electronic thermostat with a rear mounted adjustment knob. Once energised, the fan will run will run continuously while the thermostst will monitor the incoming air temperature and adjust the heat output accordingly. Where additional manual control is required a CS-1 wall mounted controller should be used (see opposite page). The CS-1 should be positioned in a convenient location and provides on/off/high heat/low heat/ fan-only settings. SCHG-45 4.5kW Heater The SCHG-45 can be controlled by a CS-1 wall-mounted controller (see opposite page). The CS-1 should be positioned in a convenient location and provides on/off/high heat/low heat/fan-only settings. Alternatively thermostatic control can be provided by a remote mounted Hard Case Thermostat (see opposite page) however as the heater will draw 20A a suitably rated contactor would be required (see page 59) SCH Dimensions 6 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

SCH Fan Assisted Heaters - Specifications Model Volts kw Airflow m³/h Controls Weight (kg) Recommended Mounting Height (m) SCHG-30 230 3.0 220 Remote (select option) 9 2.5-3.0 SCHG-30E 230 3.0 220 Built-in Electronic 9 2.5-3.0 Thermostat SCHG-45 230 4.5 330 Remote (select option) 10 3.0-4.0 Optional Remote Mounted Control Device Model Description Full Details on Page CS-1 Controller for all SCH models 58 HC-T1 Tamperproof Thermostat 16A 51 HC-D Tamperproof Tool for HC-T1 51 This table only shows the basic HC-T1 Hard Case thermostat. However it is possible that an alternative thermostat from the Hard Case Range may be more suitable for any given installation. Please see page 51 for full details of the Hard Case range. FAN ASSISTED HEATERS CS-1 HC-T1 HC-D Tamperproof Tool for HC-T1 SCH-30 and diffuser Rear view of SCH-30E showing terminal enclosures and thermostat set-point adjustment knob FOR MULTI-HEATER SYSTEMS WE RECOMMEND OUR CHS SYSTEM - See PAGE 8 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 7

FAN ASSISTED HEATERS CHS System Multi-heater System for 600 x 600 Ceiling Grid Fastest possible installation time for a multi-heater system Efficient and economic temperature control without the need for external contactors or relays Providing warm inviting commercial premises Ceiling mounting position allows free use of floor and wall space, an important consideration in retail premises First class whole life value from a product built to the highest possible standard and designed to give many years of trouble free service Typical Application Larger retail outlets requiring a number of heaters The CHS System The CHS system allows a group of ceiling heaters and optional overdoor heater to be controlled by a single CS-1 remote mounted controller and/or a single remote mounted thermostat. The CHS system comprises one master heater and any quantity of slave heaters including a slave overdoor heater if required. Features Designed to rest in the T bar of a 600 x 600 suspended ceiling grid Air inlet and outlet through front panel no requirement for air supply from the ceiling void White aluminium egg-crate diffuser Pre-wired to rear mounted terminal enclosures Auto-reset over-temperature protection Insert Depth 210mm Optional slave overdoor heater with panel front on/off switch (must be last in the group) CHS Multi-Heater System - Specifications Model kw Master/Slave Recommended Mounting Height (m) CHS-30M 3.0 Master 2.5-3.0 CHS-30S 3.0 Slave 2.5-3.0 730S 3.0 Optional Slave Overdoor Heater Control Device Options Select CS-1 wall mounted controller and/or from a choice of two thermostats 730S Optional slave overdoor heater CS-1 A CS-1 wall-mounted controller provides on/off/high heat/low heat/fan-only settings. It can be used as the sole means of controlling a CHS system or in conjunction with a HC-T1 or PROSTAT-7 thermostat. OR Control a CHS System using a choice of basic or programmable thermostat and/or a CS-1 Controller Choice of basic or programmable thermostat CHS-30M MASTER CHS-30S SLAVE CHS-30S SLAVE 730S Optional slave overdoor heater Select as many slave heaters as required CS-1 Controller (High Heat, Low Heat, Fan-only) 8 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

HC-T1 Hard Case Thermostat The HC-T1 electronic thermostat is tamperproof and vandal resistant and provides extremely accurate temperature control. Hard Case thermostats tamperproof design ensures that only authorised personnel can adjust the temperature setting. The HC-T1 can be used as the sole means of controlling a CHS system or in conjunction with a CS-1 controller. PROSTAT-7 The PROSTAT-7 is a 7-day programmable thermostat. All 7 days can be individually programmed with up to 6 settings per day. The thermostat is powered by 3 x AA batteries (supplied). The PROSTAT-7 can be used as the sole means of controlling a CHS system or in conjunction with a CS-1 controller. Remote Mounted Control Devices for a CHS System Model Description Full Details on Page CS-1 Remote mounted controller 58 HC-T1 Hard Case Thermostat 16A 51 HC-D Tamperproof Tool for Hard Case Thermostat 51 PROSTAT-7 7 day programmable Thermostat 57 FAN ASSISTED HEATERS This table only shows the basic HC-T1 Hard Case thermostat. However it is possible that an alternative thermostat from the Hard Case Range may be more suitable for any given installation. Please see page 51 for full details of the Hard Case range. CS-1 HC-T1 HC-D Tamperproof Tool for HC-T1 PROSTAT-7 Rear view of CHS-30S showing terminal enclosures Rear view of CHS-30M showing terminal enclosures web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 9

FAN ASSISTED HEATERS RH Recessed Fan Assisted Heaters Providing warm inviting commercial premises Choice of mounting positions (ceiling or wall) allows free use of floor and wall space, often an important consideration First class whole life value from a product built to the highest possible standard and designed to give many years of trouble free service Low running costs by selecting from a range of control options RH-30 RH-20 RH-60 Typical Applications Overdoor heating in shops and cafes especially where it is not practical or desirable to install conventional wallmounted heater Space heating in a wide variety commercial premises Changing rooms Entrance areas Features Common to all Models Air inlet and outlet through front panel no requirement for air supply to the rear of the heater White aluminium egg-crate grille Pre-wired to rear mounted terminal enclosure Auto-reset over-temperature protection Simple fixing through the face of the heater Suitable for vertical or horizontal discharge Controlling RH Heaters All heaters in the RH range can be controlled by a CS-1 wall-mounted controller (see opposite page). The CS-1 should be positioned in a convenient location and provides on/off/high heat/low heat/fan-only settings. Where thermostatic control is preferred we recommend our tamperproof Hard Case Range (see opposite page). Hard Case thermostats tamperproof design ensures that only authorised personnel can adjust the temperature setting. When controlling the 6kW RH-60, the HC-T1 thermostat will control the heater via the heater s built-in contactor meaning that an external contactor or relay is not required. 10 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

FAN ASSISTED HEATERS RH Dimensions Rear view of RH-30 showing terminal enclosure Model A (mm) D (mm) RH-20 363 307 RH-30 595 550 RH-60 1195 1135 RH Recessed Fan Assisted Heaters - Specifications Model Volts kw Airflow (m³/h) Aperture Size (mm) Insert Clearance (mm) Weight (kg) RH-20 230 2.0 120 315 x 150 200 3.3 RH-30 230 3.0 250 560 x 150 200 4.2 RH-60 230 6.0 500 1145 x 150 230 11 Remote Mounted Control Devices for the RH Range Model Description Full Details on Page CS-1 Controller for all SCH models 58 HC-T1 Tamperproof Thermostat 16A 51 HC-D Tamperproof Tool for Hard Case Thermostat 51 This table only shows the basic HC-T1 Hard Case thermostat. However it is possible that an alternative thermostat from the Hard Case Range may be more suitable for any given installation. Please see page 51 for full details of the Hard Case range. CS-1 HC-T1 HC-D Tamperproof Tool for HC-T1 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 11

FAN ASSISTED HEATERS OUH Unit Heaters Providing an efficient means of heating large industrial premises Exceptional reliability backed by 5 year warranty The most robust industrial unit heater available Typical Applications Warehouses Workshops The installed load must exceed the heat loss from the entire area. OUH unit heaters are space heaters they are NOT suitable for spot heating. Features Common to all Models FIVE YEAR WARRANTY Integral contactor and fused control circuit Heavy gauge steel construction with almond (RAL9001) finish Adjustable louvers Wall and ceiling brackets supplied as standard Optional suspension kit (OUH-J) Optional diffuser (OUH-CD) for use with suspended heaters; aids air circulation Optional factory fitted built-in thermostat (OUH-TH-16) Terminals supplied for easy connection to remote control devices Auto-reset over-temperature protection 5 Mounting options with brackets provided Optional Diffuser for vertical suspension Controlling OUH Heaters The recommended means of controlling OUH Unit Heaters is to select one of four control packages: Comfort control package Frost protection package Programmable package Programmable package with set-back All control packages are based on BN Thermic s range of Hard Case tamperproof and vandal resistant thermostats. Hard Case thermostats tamperproof design ensures that only authorised personnel can adjust the temperature setting. When a single heater is installed, the thermostat is generally installed immediately below the heater. Where a number of heaters are installed a decision must be made whether each heater is to be controlled by a dedicated thermostat or whether a centrally located thermostat should be used to control all the heaters in the group. The decision will be made taking into account the size and layout of the building in question. 12 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Comfort Control Package The comfort package utilises the Hard Case HC-T1 tamperproof thermostat which should be wall mounted at approximately 1.5m above floor level. The thermostat will switch the heater via the heater s built-in contactor. Control Components HC-T1 Tamperproof Thermostat Frost Protection Control Package The frost protection package utilises the Hard Case HC-TF1 tamperproof thermostat which should be wall mounted at approximately 1.5m above floor level. The thermostat will switch the heater via the heater s built-in contactor. Control Components HC-TF1 Tamperproof Thermostat HC-T1 Thermostat FAN ASSISTED HEATERS Programmable Package The programmable package utilises the Hard Case HC-T1 tamperproof thermostat which should be wall mounted at approximately 1.5m above floor level. The thermostat will switch the heater via the heater s built-in contactor. A 24 hour/7 day programmable timer (TIM-D1) will ensure that the heating system is not energised while the building is unoccupied (typically at night and at weekends). The programmable timer has a built-in run-down clock that is triggered by a remote mounted boost button. This feature will provide a temporary temperature boost for a predetermined length of time during a period when the system would normally be off. The boost command can be cancelled by depressing the boost button for 3 seconds. Control Components HC-T1 Tamperproof Thermostat TIM-D1 Programmable Timer TIM-E1 Timer Enclosure TIM-B1 Push Button for temporary boost HC-TF1 Thermostat TIM-B1 Push Button Programmable Package with Set-Back The programmable package with set-back utilises the Hard Case HC-SR1 tamperproof thermostat TIM-D1 Timer and TIM-E1 Enclosure which should be wall mounted at approximately 1.5m above floor level. The thermostat will switch the heater via the heater s built-in contactor. The HC-SR1 has two settings: high (comfort) and low (set-back). A 24 hour/7 day programmable timer (TIM-D1) will ensure that the heating system operates at its low (set-back) setting while the building is unoccupied (typically at night and at weekends). The programmable timer has a built-in run-down clock that is triggered by a remote mounted boost button. This feature will provide a temporary temperature boost for a pre-determined length of time during a period when the system would normally be in set-back mode. The boost command can be cancelled by depressing the boost button for 3 seconds. Control Components HC-SR1 Tamperproof Thermostat TIM-D1 Programmable Timer TIM-E1 Timer Enclosure TIM-B1 Push Button for temporary boost HC-SR1 Thermostat web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 13

OUH Continued OUH Unit Heaters - Specifications FAN ASSISTED HEATERS Model Volts kw Airflow Dimensions (mm) Weight (m³/h) H W D (kg) OUH-03-1 230 3 1180 305 420 432 23 OUH-03-3 400/3N 3 1180 305 420 432 23 OUH-05-1 230 5 1180 305 420 432 23 OUH-05-3 400/3N 5 1180 305 420 432 23 OUH-07-1 230 7.5 1180 305 420 432 23 OUH-07-3 400/3N 7.5 1180 305 420 432 23 OUH-10 400/3N 10 1180 305 420 432 23 OUH-15 400/3N 15 2200 444 560 572 35 OUH-20 400/3N 20 2200 444 560 572 35 OUH-25 400/3N 25 2200 444 560 572 35 OUH-TH-16 Optional factory fitted thermostat 5⁰C to 35⁰C 0.3 OUH-J J hooks for vertical suspension (set of 4) 2.0 OUH-CD1 Diffuser for suspended heater 3kW to 10kW 4.0 OUH-CD2 Diffuser for suspended heater 15kW to 25kW 7.0 Hard Case Thermostats Model HC-T1 HC-TF1 HC-SR1 HC-D Description Tamperproof thermostat Tamperproof frost thermostat Tamperproof thermostat switching between high and low settings using remote timer (Tim-D1) Tamperproof Tool for Hard Case (HC) range All Hard Case models have the option of a remote sensor (see page 53) Timer Model TIM-D1 TIM-E1 TIM-B1 Description Programmable timer Terminal enclosure for TIM-D1 timer Push Button for use with TIM-D1 (provides temporary boost) TIM-D1 Timer and TIM-E1 Enclosure TIM-B1 Push Button HC-T1 HC-SR1 HC-D Tamperproof Tool for HC Range 14 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

DSU Destratification Units Reducing heating bills by up to 30% by recycling warm air that has collected at high level. Recommended for industrial premises where roof height exceeds 4m Typical Applications Warehouses Exhibition Halls Ideally suited for use in conjunction with BN Thermic s OUH Industrial Unit Heaters Features Reduces heating costs by up to 30% Heavy duty steel construction Built-in thermostat automatically energises fan 4-way adjustable louvers Suspension kit supplied as standard (4 x 500mm chains and associated hooks) FAN ASSISTED HEATERS DSU Destratification Units - Specifications Model Volts Airflow (m³/h) Dimensions (mm) Mounting Height (m) Area Covered (m) Weight (kg) H W D DSU-4 230 4000 385 560 560 4 to 7 20 x 20 18 DSU-8 230 8000 385 720 720 7 to 12 25 x 25 24 Warehouse Example Without DSU Warm air accumulates at high level With DSU Warm air is recycled reducing heating costs by up to 30% web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 15

FAN ASSISTED HEATERS WHE Compact Heavy Duty Wall Mounted Fan Assisted Heaters Providing warmth in public areas and industrial installations Exceptional reliability backed by 5 year warranty Ideally suited to applications where space is limited Low running costs by selecting from a range of control options Typical Applications Crane cabs Toll Booths Workshops Features Common to all Models FIVE YEAR WARRANTY Can be mounted vertically or horizontally Heavy gauge steel construction with almond (RAL9001) finish Can be recessed or surface mounted with optional WHE-SB box Auto-reset over-temperature protection Controlling WHE Heaters 5 Thermostatic control is highly recommended. This is generally achieved by means of a built-in thermostat (WHE-TB) which can be made tamperproof if required. Where remote thermostatic control is preferred we recommend our tamperproof Hard Case Range (see below). Hard Case thermostats tamperproof design ensures that only authorised personnel can adjust the temperature setting. WHE Fan Assisted Heaters - Specifications Model Volts kw Airflow Dimensions (mm) Weight (m³/h) H W D (kg) WHE-1024 230 1.0 70 406 206 108 4 WHE-1524 230 1.5 135 406 206 108 4 WHE-2024 230 2.0 135 406 206 108 4 WHE-1512 110 1.5 135 406 206 108 4 WHE-SB Optional Surface Mount Box 407 206 76 1 WHE-TB Optional thermostat (can be made tamperproof) 0.3 Remote Thermostat Model Description Full Details on Page HC-T1 Hard Case Thermostat 16A 51 HC-D Tamperproof Tool for Hard Case Thermostat 51 This table only shows the basic HC-T1 Hard Case thermostat. However it is possible that an alternative thermostat from the Hard Case Range may be more suitable for any given installation. Please see page 51 for full details of the Hard Case range. HC-T1 HC-D Tamperproof Tool for HC Range 16 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

BLC Low Level Convector Heaters A practical and economic method of heating churches An unobtrusive source of warmth for a variety of commercial premises Typical Applications Churches Corridors Waiting rooms BLC-500 with BLC-TB-13 Integral Thermostat CONVECTION HEATERS BLC-750 Heating in Churches Heating a conventional church presents many problems to overcome. The large volume means that maintaining a comfortable air temperature is extremely expensive. To warm up the air from cold prior to each service would take a very long time, consume a great deal of energy and is not generally regarded as a practical solution. In many churches it is not permissible to fit heaters to walls or suspend them from the roof. Any source of heat needs to be silent and as unobtrusive as possible. Where fixed pews are in place, the BLC range provides the best method of heating in a church. The heaters should be fixed to the back-board of the pew below the seat. BLC convection heaters provide direct heat to the people sitting in the pews. As no attempt is made to build up a body of warm air within the church, the heaters can be switched on minutes before a service starts and switched off immediately it finishes. BLC convection heaters are extremely unobtrusive. When painted dark brown and installed under a traditional pew they are barely noticeable. Natural convection heaters such as the BLC are silent and with no moving parts require little maintenance. As the BLC is a direct source heat, only occupied pews need to be heated. Features Robust steel construction with central baffle plate to promote convection currents Long life metal sheathed finned heating element Choice of almond (RAL9001) of dark brown (RAL8014) finishes Auto-reset over-temperature protection Electrical connections can be made at either end of the heater Optional safety guards with dark brown (RAL8014) finish Optional floor mounting brackets with dark brown (RAL8014) finish BLC mounted under a church pew web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 17

CONVECTION HEATERS BLC Continued Controlling BLC Heaters in a Church Controlling BLC heaters in a church is generally as simple as switching on the required heaters immediately before a service and switching them off once the pews have been vacated. This can be achieved manually or by means of a programmable timer if preferred. It is not usually necessary to use thermostatic control in a church application as there is no attempt being made to build up and maintain a body of warm air. Controlling BLC Heaters in a Conventional Space Heating Application For maximum economy we suggest the heaters are thermostatically controlled. This is most easily achieved by specifying the BLC-TB-13 factory fitted thermostat. This device has an external control knob allowing easy adjustment of the temperature set-point. Where tamperproof control is required a Hard Case HC-T1 wall mounted thermostat should be used. The HC-T1 will switch a group of BLC heater up to a combined load of 16A or larger loads via a suitably rated contactor (see page 59). The Hard Case tamperproof design ensures that only authorised personnel can adjust the temperature setting. BLC Low Level Convector Heaters - Specifications Model Volts kw Dimensions (mm) Finish Recommended Weight H W D Guard (kg) BLC-300 230 0.3 148 566 62 Almond BLC-EXG6 3.0 BLC-500 230 0.5 148 691 62 Almond BLC-EXG7 4.0 BLC-750 230 0.75 148 945 62 Almond BLC-EXG10 5.0 BLC-1000 230 1.0 148 1206 62 Almond 2 x BLC-EXG6 6.0 BLC-300B 230 0.3 148 566 62 Brown BLC-EXG6 3.0 BLC-500B 230 0.5 148 691 62 Brown BLC-EXG7 4.0 BLC-750B 230 0.75 148 945 62 Brown BLC-EXG10 5.0 BLC-1000B 230 1.0 148 1206 62 Brown 2 x BLC-EXG6 6.0 BLC-TB-13 Optional integral thermostat To match heater - - BLC-FB Floor mounting brackets (pair) Brown - - BLC-EXG6 Safety guard 610mm Brown - - BLC-EXG7 Safety guard 730mm Brown - - BLC-EXG10 Safety guard 1000mm Brown - - Remote Thermostat Model Description Full Details on Page HC-T1 Hard Case Thermostat 16A 51 HC-D Tamperproof Tool for Hard Case Thermostat 51 This table only shows the basic HC-T1 Hard Case thermostat. However it is possible that an alternative thermostat from the Hard Case Range may be more suitable for any given installation. Please see page 51 for full details of the Hard Case range. HC-T1 HC-D Tamperproof Tool for HC Range 18 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Safety Guard for BLC Floor Mounting Brackets CONVECTION HEATERS BLS 110V Low Level Convector Heaters Providing comfort heat where only a 110V supply is available Low running costs ensured by integral thermostatic control Low profile design allows maximum use of wall space Typical Applications Site Huts Features Robust steel construction with central baffle plate to promote convection currents Long life metal sheathed finned heating element Auto-reset over-temperature protection Built-in thermostat with external knob allowing easy adjustment of temperature set-point BLS Low Level Convector Heaters - Specifications Model Volts kw Dimensions (mm) Weight (kg) H W D BLS-110-1000T 110 1.0 148 1206 62 6.0 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 19

SWD Industrial Finned Tubular Heaters Providing background or comfort heat in damp or corrosive environments Specifically designed for long life in the most demanding conditions Low running costs by selecting from a range of control options CONVECTION HEATERS Typical Applications Water treatment plants Plant rooms Lift shafts Features Common to all Models Welded stainless steel tube with stainless steel cooling fins Stainless steel brackets for floor or low level wall mounting Waterproof reinforced glass fibre terminal enclosure conforming to IP66 M20 waterproof cable gland supplied as standard Controlling SWD Heaters Thermostatic control is highly recommended. The simplest option is to select a heater with the prefix SWD-A. This indicates that a built-in adjustable thermostat is provided. The built-in thermostat has a set-point range between 5 C and 30 C and includes a frost protection setting. Where remote thermostatic control is preferred we recommend our tamperproof Hard Case range (see opposite). Hard Case thermostats tamperproof design ensures that only authorised personnel can adjust the temperature setting. The standard Hard Case is not waterproof, however the Hard Case range includes and optional remote sensor with an IP55 rating. The Hard Case HC-T1 will switch a single phase load of up to 16A and larger loads or 3-phase loads via a suitably rated contactor (see page 59) Safety Guards Where personnel have access to an SWD heater, the use of an SWG safety guard is strongly recommended. Manufactured from heavy gauge zinc plated wire, the SWG comes complete with mounting clips for easy fixing to floor or wall. SWD mounted under SWG Guard 20 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

SWD Tubular Heaters - Specifications Model Control Volts kw Dimensions (mm) Recommended H W D Guard SWD-U-500-1 None 110 0.5 170 440 130 SWG-1 3.0 SWD-U-1000-1 None 110 1.0 170 640 130 SWG-2 4.8 SWD-U-1500-1 None 110 1.5 170 840 130 SWG-3 6.2 SWD-A-500-2 Thermostat 230 0.5 170 440 130 SWG-1 3.0 SWD-A-1000-2 Thermostat 230 1.0 170 640 130 SWG-2 4.8 SWD-A-1500-2 Thermostat 230 1.5 170 840 130 SWG-3 6.2 SWD-A-2000-2 Thermostat 230 2.0 170 1040 130 SWG-3 7.7 Weight (kg) SWD-A-3000-2 Thermostat 230 3.0 170 1440 130 SWG-4 10.9 SWD-U-500-2 None 230 0.5 170 440 130 SWG-1 3.0 SWD-U-1000-2 None 230 1.0 170 640 130 SWG-2 4.8 SWD-U-1500-2 None 230 1.5 170 840 130 SWG-3 6.2 SWD-U-2000-2 None 230 2.0 170 1040 130 SWG-3 7.7 SWD-U-3000-2 None 230 3.0 170 1440 130 SWG-4 10.9 SWD-U-4000-2 None 230 4.0 170 1840 130 SWG-5 13.7 SWD-U-1000-3 None 400/3 1.0 170 640 130 SWG-2 4.8 SWD-U-1500-3 None 400/3 1.5 170 840 130 SWG-3 6.2 SWD-U-2000-3 None 400/3 2.0 170 1040 130 SWG-3 7.7 SWD-U-3000-3 None 400/3 3.0 170 1440 130 SWG-4 10.8 SWD-U-4000-3 None 400/3 4.0 170 1840 130 SWG-5 13.7 SWG-1 Recommended Guard 240 450 240 1.0 SWG-2 Recommended Guard 240 650 240 1.5 SWG-3 Recommended Guard 240 1075 240 2.0 SWG-4 Recommended Guard 240 1600 240 3.5 SWG-5 Recommended Guard 240 1900 240 4.0 CONVECTION HEATERS Remote Thermostat Model HC-T1 HC-T1/R HC-SW1 HC-D Description Tamperproof thermostat 16A Tamperproof Thermostat (for use with remote sensor) Waterproof Sensor (IP55) Tamperproof Tool for Hard Case (HC) range This table only shows the basic HC-T1 Hard Case thermostat. However it is possible that an alternative thermostat from the Hard Case range may be more suitable for any given installation. Please see page 51 for full details of the Hard Case range. HC-T1 HC-D Tamperproof Tool for HC-T1 HC-SW1 IP55 Sensor web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 21

HWP2 Patio Heater Providing safe, instant comfort heat in outdoor locations Ensures the maximum use of outdoor facilities Minimal maintenance especially when compared to gas systems Low running costs by selecting from a range of control options Smart modern design complementing external decor HWP2-B RADIANT HEATERS Typical Applications Patios both commercial and domestic Pub gardens Pavement cafes Golf driving ranges Nightclub queuing areas Smoking areas Features Common to all Models IP55 rating allowing the heater to be installed and left outdoors throughout the year HWP2-W Aluminium construction with stainless steel safety grille High quality halogen lamp with 7000 hours average operating life Halogen lamp is easily replaceable Choice of black or white finish Wall mounting bracket and parasol clamp supplied as standard Open fronted design provides a 25% increase in heating efficiency when compared with glass-fronted heaters Controlling HWP Patio Heaters As HWP patio heaters are 100% effective the instant they are switched on, we recommend a control system that will de-energise a heater when heating is not required. This can be achieved by means of a Push Button Timer or a Movement Detector. Push Button Timer The BN Thermic TS-3 is a compact, surface mount, weatherproof device conforming to IP66. A simple push button will energise a heater or heaters for a pre-programmed period between 2 minutes and 2 hours. Once this period has elapsed the heating will be automatically switched off until the button is pushed again. The device is vandal resistant and tamperproof meaning only authorised personnel can adjust the time settings. For full details of the TS-3 see page 54. The TS-3 has a switching capacity of 16A. It can therefore directly switch a combined load of up to 3kW. Larger loads or 3-phase loads can be switched via a suitably rated contactor (see page 59). Movement Sensor The BN Thermic WH-402 is a compact, surface mount, weatherproof device conforming to IP55. The WH-402 will detect movement in an area up to 12m from its mounting position in a 180 arc. Both distance and angle of detection can be reduced if required. Once movement has been detected, the heating will be switched on. If no further movement is detected within a preprogrammed time period (5 seconds to 18 minutes) the heating will be automatically switched off. TS-3 WH-402 The device is vandal resistant and tamperproof meaning only authorised personnel can adjust the time settings. For full details of the WH-402 see page 58. The WH-402 has a switching capacity of 16A. It can therefore directly switch a combined load of up to 3kW. Larger loads or 3-phase loads can be switched via a suitably rated contactor (see page 59). 22 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Dimmer In specific applications there may be a need to adjust the intensity of the heat output from a HWP patio heater. The BN Thermic VR-1 provides adjustment between 0% and 100% of heater output. It also has a definite click to off allowing it to be used as an on/off switch. The VR-1 is a surface mount device but is not suitable for outdoors installation. For full details of the VR-1 see page 57. The VR-1 has a switching capacity of 13A. It can therefore directly switch a combined load of up to 3kW. For larger loads more than one VR-1 dimmer will be required. VR-1 Patio Heater Selection Use the following diagram and table to select the optimum mounting position. In an exposed location and where mounting height is relatively high, we recommend installing a 2kW heater. H X Wall Mounted RADIANT HEATERS Y Z Area covered by the heater Wall Mounted Area Covered H X Y Z 2.0m 2.3m 2.4m 4.0m 7.6m 2.5m 3.0m 3.0m 5.2m 12.3m HWP2 Patio Heater - Specifications Model Volts kw Finish Dimensions (mm) Weight H W D (kg) HWP2-W 230 1.5 White 120 480 120 1.7 HWP2-B 230 1.5 Black 120 480 120 1.7 HWP2-2B 230 2.0 Black 120 480 120 1.7 Replacement Lamps Model RL15CW RL20GW Description 1.5kW Lamp for HWP2-W and HWP2-B Patio Heater 2kW Lamp for HWP2-2B Patio Heater Optional Remote Mounted Control Devices Model Description Full Details on Page WH-402 Movement sensor (16A) 58 TS-3 Push button timer (16A) 54 VR-1 Dimmer (13A) 58 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 23

HN Series Shortwave Infrared Halogen Heaters Providing instant comfort heat in a variety of commercial buildings. Especially suited to irregularly used buildings where conventional space heating is impractical. Ideally suited to spot heating a defined area within an otherwise unheated space Low running costs by selecting from a range of control options RADIANT HEATERS HN-1500G HN-3000G HN-4500G Typical Applications Community halls Churches Workshops Packing areas Features Common to all Models Aluminium construction with closely spaced safety grille High quality halogen lamp with 7000 hours average operating life Halogen lamp is easily replaceable High quality ivory paint finish Wall mounting bracket providing up and down and side to side angle adjustment Optional suspension kit Gold lamp with soft pink glow Controlling HN Heaters As HN shortwave infrared halogen heaters are 100% effective the instant they are switched on, we recommend a control system that will de-energise a heater when heating is not required. This can be achieved by means of a Push Button Timer or a Movement Detector. Push Button Timer TS-3 pre-programmed time delay The BN Thermic TS-3 is a compact, surface mount, weatherproof device conforming to IP66. A simple push button will energise a heater or heaters for a pre-programmed period between 2 minutes and 2 hours. Once this period has elapsed the heating will be automatically switched off until the button is pushed again. The device is vandal resistant and tamperproof meaning only authorised personnel can adjust the time settings. For full details of the TS-3 see page 54. The TS-3 has a switching capacity of 16A. It can therefore directly switch a combined load of up to 3kW. Larger loads or 3-phase loads can be switched via a suitably rated contactor (see page 59). Push Button Timer TS-4 user selectable time delay The BN Thermic TS-4 is designed for installation into a standard single-gang back box. A simple push button provides 15 minute/ 30 minute / 1 hour / 2 hour settings. Once the selected period has elapsed the heating will be automatically switched off until the button is pushed again. The time setting can be changed at any point during the cycle and the timer also provides a means of switching the heating off. For full details of the TS-4 see page 54. The TS-4 has a switching capacity of 13A. It can therefore directly switch a combined load of up to 3kW. Larger loads or 3-phase loads can be switched via a suitably rated contactor (see page 59). TS-3 TS-4 24 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Movement Sensor The BN Thermic WH-402 is a compact, surface mount, weatherproof device conforming to IP55. The WH-402 will detect movement in an area up to 12m from its mounting position in a 180 arc. Both distance and angle of detection can be reduced if required. Once movement has been detected, the heating will be switched on. If no further movement is detected within a pre-programmed time period (5 seconds to 18 minutes) the heating will be automatically switched off. The device is vandal resistant and tamperproof meaning only authorised personnel can adjust the time settings. For full details of the WH-402 see page 58. The WH-402 has a switching capacity of 16A. It can therefore directly switch a combined load of up to 3kW. Larger loads or 3-phase loads can be switched via a suitably rated contactor (see page 59). Dimmer In specific applications there may be a need to adjust the intensity of the heat output from a Shortwave Infrared Halogen Heater. The BN Thermic VR-1 provides adjustment between 0% and 100% of heater output. It also has a definite click to off allowing it to be used as an on/off switch. For full details of the VR-1 see page 58. The VR-1 has a switching capacity of 13A. It can therefore directly switch a combined load of up to 3kW. For larger loads more than one VR-1 dimmer will be required. Heater Selection Heat Requirements Use Table 1 to determine the total KW output required. The W/m applicable to the type of activity and the nature of the building should be multiplied by the toal area in m. The spot heating figure should be used when heating a section of an otherwise unheated building. The output, position and mounting height of the heaters can be determined using Table 2. We suggest that the areas covered by individual heaters are allowed to overlap by 10% to 15% to ensure even coverage. Table 1 W/m required Heavy Work Light Work Spot Heating Highly 150 200 250 Insulated Insulated 175 225 250 Un-Insulated 200 250 275 Light Cladding 250 300 300 Badly insulated/ damp 300 300 300 Spot Heating As an additional guide to spot heating, we would also recommend heating from two directions, to cover the area from opposite Wall Mounted X Y sides. This will ensure an overall feeling of comfort and warmth. A heat loading of 250-300 W/m can be considered as a guide for this type of area. Z H Y WH-402 VR-1 Ceiling Mounted X RADIANT HEATERS Table 2 HN-1500 or HN-2000 HN-3000 HN-4500 or HN-6000 Wall Mounted Area Covered Overhead Mounted (m) Area Covered H X Y Z (m ) H X Y (m ) 2.5 3.2 2.6 6.0 11.9 3.0 3.0 2.0 6.0 3.0 3.4 3.6 6.7 18.2 3.5 3.3 2.3 7.6 3.0 3.7 3.6 7.0 19.2 3.5 3.3 2.6 8.6 3.5 4.0 4.2 7.9 25.0 4.0 5.0 3.1 15.5 3.5 4.0 4.2 8.1 25.4 4.0 5.0 3.4 17.0 4.0 4.3 4.5 8.4 28.6 5.0 5.3 3.7 19.6 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 25

HN Continued HN Series Shortwave Infrared Halogen Heaters - Specifications RADIANT HEATERS Model Volts kw Dimensions (mm) Weight (kg) H W D HN-1500G 230 1.5 275 430 140 3.8 HN-2000G 230 2.0 275 430 140 3.8 HN-3000G 230 3.0 430 430 140 5.5 HN-4500G 230/400 4.5 590 430 140 6.5 HN-6000G 230/400 6.0 590 430 140 6.5 RL15GF 230 1.5 Replacement Gold Lamp RL20GF 230 2.0 Replacement Gold Lamp RL15RF 230 1.5 Replacement Ruby Lamp RL20RF 230 2.0 Replacement Ruby Lamp HSK Suspension Kit (chain not supplied) Optional Remote Mounted Control Devices Model Description Full Details on Page WH-402 Movement sensor (16A) 58 TS-3 Push button timer (16A) 54 TS-4 Push button timer - user selectable time delay (13A) 54 VR-1 Dimmer (13A) 58 HN-Shortwave Infrared Halogen Heater used for spot heating in an unheated warehouse HN-Shortwave Infrared Halogen Heater with long life gold lamps 26 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

RL Replacement Infrared Lamps A range of shortwave quartz halogen heat lamps to suit almost all available heaters from a variety of manufacturers. Lamps with flexible leads and SK15 caps Used in a variety of open fronted commercial and industrial heaters. Average lamp life 7000 hours Colour options Lamp length Ruby Fork terminal Push fit terminal Gold Model kw Voltage Colour Lamp length (mm) Lead length (mm) Terminal RL10RF 1 230 Ruby 346 230 Fork RL10GF 1 230 Gold 353 230 Fork RL15RF 1.5 230 Ruby 346 230 Fork RL15GF 1.5 230 Gold 353 230 Fork RL15RF/1 1.5 120 Ruby 346 230 Fork RL15RP 1.5 230 Ruby 346 440 Push Fit RL15GP 1.5 230 Gold 346 440 Push Fit RL20RF 2 230 Ruby 346 230 Fork RL20GF 2 230 Gold 353 230 Fork RL20RP 2 230 Ruby 346 440 Push Fit Weatherproof (IP55) lamps with flexible leads Generally used in open fronted patio heaters. Average lamp life 7000 hours Colour options Lead length Lamp length RADIANT HEATERS Clear Gold Model kw Voltage Colour Lamp length (mm) Lead length (mm) Terminal RL15CW 1.5 230 Clear 440 375 Plain Ferrule RL15GW 1.5 230 Gold 440 375 Plain Ferrule RL20GW 2 230 Gold 440 375 Plain Ferrule Lamps with R7s caps Lead length Generally used in glass fronted patio heaters. This lamp is used with spring loaded fittings. Average lamp life 3000 hours in glass fronted heaters. Lamp length Model kw Voltage Colour Lamp length (mm) RL13GS 1.3 230 Gold 254 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 27

CH Ceramic Heaters Providing virtually instant comfort heat in a variety of commercial buildings. Especially suited to irregularly used buildings where conventional space heating is impractical. Avoids the light output associated with shortwave infrared heaters Ideally suited to spot heating a defined area within an otherwise unheated space Low running costs by selecting from a range of control options RADIANT HEATERS Typical Applications Please note ceramic heaters are best suited to buildings with relatively low ceilings Community halls Workshops Kennels Zoos Features Common to all Models Aluminium construction with safety grille Long life ceramic heat emitters High quality ivory paint finish Wall mounting bracket and providing up and down and side to side angle adjustment Controlling CH Heaters As CH ceramic heaters are virtually 100% effective the instant they are switched on, we recommend a control system that will de-energise a heater when heating is not required. This can be achieved by means of a Push Button Timer or a Movement Detector. Push Button Timer TS-3 pre-programmed time delay The BN Thermic TS-3 is a compact, surface mount, weatherproof device conforming to IP66. A simple push button will energise a heater or heaters for a pre-programmed period between 2 minutes and 2 hours. Once this period has elapsed the heating will be automatically switched off until the button is pushed again. The device is vandal resistant and tamperproof meaning only authorised personnel can adjust the time settings. For full details of the TS-3 see page 54. The TS-3 has a switching capacity of 16A. It can therefore directly switch a combined load of up to 3kW. Larger loads or 3-phase loads can be switched via a suitably rated contactor (see page 59). Push Button Timer TS-4 user selectable time delay The BN Thermic TS-4 is designed for installation into a standard single-gang back box. A simple push button provides 15 minute/ 30 minute / 1 hour / 2 hour settings. Once the selected period has elapsed the heating will be automatically switched off until the button is pushed again. The time setting can be changed at any point during the cycle and the timer also provides a means of switching the heating off. For full details of the TS-4 see page 54. The TS-4 has a switching capacity of 13A. It can therefore directly switch a combined load of up to 3kW. Larger loads or 3-phase loads can be switched via a suitably rated contactor (see page 59). TS-3 TS-4 28 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Movement Sensor The BN Thermic WH-402 is a compact, surface mount, weatherproof device conforming to IP55. The WH-402 will detect movement in an area up to 12m from its mounting position in a 180 arc. Both distance and angle of detection can be reduced if required. Once movement has been detected, the heating will be switched on. If no further movement is detected within a pre-programmed time period (5 seconds to 18 minutes) the heating will be automatically switched off. WH-402 The device is vandal resistant and tamperproof meaning only authorised personnel can adjust the time settings. For full details of the WH-402 see page 58. The WH-402 has a switching capacity of 16A. It can therefore directly switch a combined load of up to 3kW. Larger loads or 3-phase loads can be switched via a suitably rated contactor (see page 59). CH Ceramic Heaters - Specifications Model Volts kw Dimensions (mm) Weight (kg) H W D CH-1500 230 1.5 190 405 72 1.8 CH-3000 230 3.0 345 405 72 2.8 Optional Remote Mounted Control Devices RADIANT HEATERS Model Description Full Details on Page WH-402 Movement sensor (16A) 58 TS-3 Push button timer (16A) 54 TS-4 Push button timer - user selectable time delay (13A) 54 Bracket fitted with extension arm providing up and down and side to side adjustment Bracket providing up and down adjustment web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 29

ESN Black Heat Radiant Cassettes Providing an extremely economic means of heating large commercial spaces Exceptional reliability backed by 5 year warranty Attractive unobtrusive design well suited to modern facilities High mounting positions allows flexible use of floor and wall space and does not interfere with activities RADIANT HEATERS Typical Applications Sports Halls Squash Courts Showrooms Community Halls Food Halls The installed load must exceed the heat loss from the entire area. ESN black heat radiant cassettes are not ideally suited to spot heating applications. Features Common to all Models FIVE YEAR WARRANTY No draughts, noise or light output Robust steel case with attractive white epoxy finish Specially treated aluminium heat emitter Brackets for ceiling mounting and four fixing points to facilitate suspension 5 Selection and Installation The total load of the selected ESN cassettes should exceed the heat loss from the building in cold conditions. The heaters should be ceiling mounted or suspended at high level ensuring that the space between the heaters is no greater than the distance between the heaters and the floor. Black Heat Radiant Cassettes should be seen as an energy saving alternative to conventional space heating systems, they are not ideally suited to spot heating applications. 2.32m 0.35m 4.64m 0.35m 2.32m 2.58m 1.5m 5.16m 1.5m 5.16m 1.5m 2.58m 20m Typical ESN System Layout 10m Energy Saving Black Heat Radiant Cassettes are the most economic heaters for buildings with high roofs for the following reasons. The gentle radiant effect means that the experienced temperature can be up to 4 C warmer than the actual air temperature. This means that the thermostat can be set up to 4 C lower. The temperature gradient is negligible. Typically air temperature will increase by 0.3 C per metre above floor level. This figure compares to a typical 2.5 C per metre when using fan heaters. 30 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Controlling ESN Black Heat Radiant Cassettes The recommended means of controlling ESN Black Heat Radiant Cassettes is to select one of four control packages Comfort control package Programmable package Programmable package with set-back Flexible Package All control packages are based on BN Thermic s range of Hard Case tamperproof and vandal resistant thermostats. Hard Case thermostats tamperproof design ensures that only authorised personnel can adjust the temperature setting. Comfort Control Package The comfort package utilises the Hard Case HC-T1 tamperproof thermostat which should be wall mounted at approximately 1.5m above floor level. The thermostat will switch the heaters via a suitably rated contactor. Control Components HC-T1 Tamperproof Thermostat Suitably Rated Contactor RADIANT HEATERS HC-T1 Tamperproof thermostat CON Contactor selected to suit heating load ESN Group of black heat radiant cassettes Programmable Package The programmable package utilises the Hard Case HC-T1 tamperproof thermostat which should be wall mounted at approximately 1.5m above floor level. The thermostat will switch the heaters via a suitably rated contactor. A 24 hour/7 day programmable timer (TIM-D1) will ensure that the heating system is not energised while the building is unoccupied (typically at night and at weekends). The programmable timer has a built-in run-down clock that is triggered by a remote mounted boost button. This feature will provide a temporary temperature boost for a predetermined length of time during a period when the system would normally be off. The boost command can be cancelled by depressing the boost button for 3 seconds. Control Components HC-T1 Tamperproof Thermostat TIM-D1 Programmable Timer TIM-E1 Timer Enclosure TIM-B1 Push Button for temporary boost Suitably Rated Contactor TIM-B1 Push Button For temporary boost TIM-D1 Programmable timer HC-T1 Tamperproof thermostat CON Contactor selected to suit heating load ESN Group of black heat radiant cassettes web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 31

RADIANT HEATERS ESN Continued Programmable Package with Set-Back The programmable package with set-back utilises the Hard Case HC-SR1 tamperproof thermostat which should be wall mounted at approximately 1.5m above floor level. The thermostat will switch the heaters via a suitably rated contactor. The HC-SR1 has two settings: high (comfort) and low (set-back). A 24 hour/7 day programmable timer (TIM-D1) will ensure that the heating system operates at its low (set-back) setting while the building is unoccupied (typically at night and at weekends). The programmable timer has a built-in run-down clock that is triggered by a remote mounted boost button. This feature will provide a temporary temperature boost for a pre-determined length of time during a period when the system would normally be in set-back mode. The boost command can be cancelled by depressing the boost button for 3 seconds. Control Components HC-SR1 Tamperproof Thermostat TIM-D1 Programmable Timer TIM-E1 Timer Enclosure TIM-B1 Push Button for temporary boost Suitably Rated Contactor HIGH LOW TIM B1 Push Button For temporary boost TIM D1 Programmable timer HC-SR1 Tamperproof thermostat with high-low settings CON Contactor selected to suit heating load ESN Group of black heat radiant cassettes Flexible Package The flexible control package utilises a Hard Case HC-ST1 thermostat switching a group of Black Heat Radiant Cassettes via a suitably rated contactor. The HC-ST1 has two settings: high (comfort) and low (set-back). The default setting is low (set-back). The HC- ST1 incorporates a simple push button which changes the set-point from low (set-back) to high (comfort) for a pre-programmed period of time (1/2, 1, 2 or 4 hours). Once this period of time has elapsed the thermostat will automatically revert to its low (set-back) setting. Control Components HC-ST1 Tamperproof Thermostat Suitably Rated Contactor HIGH LOW HC-ST1 Tamperproof thermostat with high-low settings and run-down timer CON Contactor selected to suit heating load ESN Group of black heat radiant cassettes 32 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

ESN Black Heat Radiant cassettes - Specifications Model Volts kw Dimensions (mm) Mounting Weight (kg) H W D Height (m) ESN-09 230 0.9 50 1500 130 2.8 to 10 5.8 ESN-12 230 1.2 50 1500 130 2.8 to 10 5.8 ESN-18 230 1.8 50 1500 230 3.0 to 15 9.9 ESN-24 230 2.4 50 1500 230 3.0 to 15 9.9 ESN-30 230 or 400/3N 3.0 50 1500 350 3.0 to 15 13.9 ESN-36 230 or 400/3N 3.6 50 1500 350 3.0 to 15 13.9 ESN-WB Wall mounting bracket for ESN-09 and ESN-12 only Tamperproof Thermostats Model HC-T1 HC-SR1 HC-ST1 HC-D Description Tamperproof thermostat for industrial environment HC-T1 switches between high and low settings using built-in rundown timer Switches between high and low settings using remote timer (TIM-D1) Set-Back Thermostat with Run-Down Timer Tamperproof Tool for Hard Case (HC) range All Hard Case models have the option of a remote sensor (see pages 51-53) RADIANT HEATERS HC-T1 Hard Case Thermostat HC-SR1 HC-ST1 HC-D Tamperproof Tool for HC Range Timer Model Description TIM-D1 Timer TIM-E1 Terminal enclosure for TIM-D1 timer TIM-B1 Push Button for use with TIM-D1 (provides temporary boost) TIM-D1 and Enclosure TIM-B1 Push Button Contactors (230V coil) Model Phases Amperage/ Max kw/phase Enclosure Type Phase CON-20 1 20 4.4 A CON-40 1 40 7.8 B CON-63 1 63 12 B CON-30-3 3 30 6 C CON-45-3 3 45 9.8 C CON-80-3 3 80 16 D CON-110-3 3 110 23 D ENCL-A Contactor Enclosure Type A ENCL-B Contactor Enclosure Type B ENCL-C Contactor Enclosure Type C ENCL-D Contactor Enclosure Type D Contactor and Enclosure web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 33

RP Radiant Ceiling Panels Providing a sophisticated noise and draught free means of heating commercial premises Low running costs Extra safety as personnel have no access to heaters Ceiling mounting allows flexible use of floor and wall space and does not interfere with activities RADIANT HEATERS Typical Applications Offices Trade Counters Care Homes Meeting Rooms The installed load must exceed the heat loss from the entire area. RP black heat radiant cassettes are not ideally suited to spot heating applications although they can provide a localised temperature boost within a larger space perhaps over a work station. Features Common to all Models Specifically designed for quick and easy installation into suspending ceilings Bracket supplied for easy mounting onto a conventional ceiling Attractive white finish Fully enclosed steel case conforming to IP44 Integral insulation layer ensures that radiant energy is directed into the room Selection and Installation The total load of the selected RP Ceiling Panels should exceed the heat loss from the building in cold conditions. The heaters should be positioned so that the space between the heaters is no greater than the distance between the heaters and the floor. RP Ceiling Panels should be seen as an economic alternative to conventional space heating systems, they are not ideally suited to 7.2m spot heating applications although they can provide a localised temperature boost within a larger space perhaps over a work station. RP-06 ceiling mounted 5.4m Typical arrangement of RP-03 ceiling panels in a 600 x 600 ceiling grid 34 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Energy Saving Reverse side RP-03 showing mounting brackets RP Ceiling Panels are a more economic means of heating commercial premises than conventional heating systems. The gentle radiant effect means that the experienced temperature can be up to 4 C warmer than the actual air temperature. This means that the thermostat can be set up to 4 C lower. The temperature gradient is negligible. Typically air temperature will increase by 0.3 C per metre above floor level. This figure compares to a typical 2.5 C per metre when using fan heaters. RADIANT HEATERS Controlling RP Radiant Ceiling Panels BN Thermic s Hard Case range of tamperproof thermostats is ideally suited to controlling a radiant heating system. Its tamperproof design enhances the system s economy by ensuring that that only authorised personnel can adjust the temperature setting. RP Radiant Ceiling Panels - Specifications Model Volts kw Dimensions (mm) Weight (kg) H W D RP-03 230 0.3 25 595 595 5 RP-06 230 0.6 25 1195 595 10 Remote Thermostat Model Description Full Details on Page HC-T1 Tamperproof Thermostat 16A 51 HC-D Tamperproof Tool for HC-T1 51 This table only shows the basic HC-T1 Hard Case thermostat. However it is possible that an alternative thermostat from the Hard Case Range may be more suitable for any given installation. Please see page 51 for full details of the Hard Case range. HC-T1 HC-D Tamperproof Tool for HC-T1 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 35

UNDERFLOOR HEATING Cable Specification EHM Heating Mats An economic method of heating a room and providing a luxurious warm floor Manufactured to highest quality for complete peace of mind and backed by a 10 year warranty Application Suitable for any room including conservatories, bathrooms and wet rooms Ideal for use with wide variety of floor surfaces including ceramic tiles, porcelain tiles, marble, slate, stone, carpet, vinyl, engineered wood and laminate flooring. Features Twin core heating cable pre-assembled onto a nylon web ensuring uniform spacing and ease of installation Pre-wired 3m power lead Continuous earth braid Continuous double sided tape of underside of heating mat allows secure placing on any clean surface Approved to EN60335-2-96 as required by the 17th Edition Wiring Regulations (BS7671.2008) EMC compliant 230V supply Twin core cable diameter 3mm to 4mm Mat cut here Earth screen protection by means of AL/PET Foil Installation Tiled Floor The EHM heating mat should be installed in a flexible self-leveling compound or directly into the tile adhesive. It is important that the heating cable is completely covered. Other Floor Surfaces (carpet, vinyl, engineered wood and laminate floor) The EHM mat should be completely covered in a flexible self-leveling compound with the required floor surface applied once the compound is completely dry. Great care must be taken to ensure that fixing devices are not driven through the heating cable. Where underlay is required, the lowest tog option is recommended. If there is any doubt about the suitability of any given floor surface for use with underfloor heating, confirmation should be sought from the flooring supplier. Selection Standard or High Density 10 Typical EHM Installation Other than in exceptional circumstances standard density heating mats will provide enough output to serve as a sole source of heat in a room. High density mats may be preferred when one of the following applies. A room has exceptionally high heat losses (this may apply to some conservatories) A very rapid heat up is required perhaps because a room is rarely used It is only possible to heat a small percentage of the total floor area Cold lead Electrical connection + thermostat Mat cut here Kitchen Larder Mat cut here 36 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Size of Mat The objective is generally to cover as high a percentage of the free floor area as possible. The free floor area is defined as the floor area not occupied by permanent fixtures such as kitchen cabinets and shower trays. As a rule of thumb, we suggest selecting a mat with total area approximately 10% less than the total free floor area. This will allow for perimeter spacing and ensure easy installation Large Rooms For large rooms it is common practice to use more than one heating mat. In these circumstances there is a choice of subdividing the room into separate zones each controlled by its own thermostat or connecting the heating mats together electrically in parallel and using a single thermostat. When controlling more than one heating mat from a single thermostat it may be necessary to incorporate a contactor into the control circuit. Control Thermostatic control must be used. BN Thermic offers a range of thermostats all of which are supplied with a floor probe. The thermostats can be configured for primary control via the built-in air sensor or via the floor sensor. When using more than one heating mat, check that the combined load of the heating mats is within the switching capacity of the selected thermostat. When the combined load is greater than the switching capacity of the selected thermostat an appropriately rated contactor must be selected. A16C Simplicity is the key. The A16C has a smart uncluttered appearance with a dial for temperature adjustment and an on/off switch. Capable of switching loads up to 3.4kW, the A16C is configurable for air and floor sensor or floor sensor only U16C The U16C offers simple 7-day programming with programming buttons hidden behind hinged doors on the thermostat face. Capable of switching loads up to 3.4kW, the U16C is configurable for air and floor sensor or floor sensor only. Features include a backlit screen and a summer switch allowing the heating to be switched off without losing the programme. T13C Using the latest touch screen technology, the T13C is the state of the art underfloor heating thermostat. It offers an unrivalled modern appearance coupled with ultra-simple 7-day programming and can be easily configured for air and floor or floor only control. The T13C can switch loads of up to 3kW and is a available in a choice of white (T13CW) or silver (T13CS) finishes. F-Board Insulation To limit downward heat loss and to significantly improve the economy of an underfloor heating system, the use of F-Board insulated tile backer boards is highly recommended. Installed directly onto the sub-floor and below the heating mat, they provide exceptional thermal insulation with minimal increase in floor height. F-Board insulated tile backer boards are generally held in place using standard tile adhesive. Selection Each F-Board covers 0.72m² and sufficient boards should be selected to completely cover the floor area. Total floor area (m²) 0.72 = minimum number of boards required T13CW A16C U16C T13CS UNDERFLOOR HEATING F-Board-6 Provides an extremely effective insulation barrier where floor build-up must be kept to a minimum. F-Board-10 As the effectiveness of insulation increases with thickness, F-Board-10 should be selected where maximum economy is required and additional floor build-up is acceptable. Features Full resistance to moisture absorption Combination of low profile, strength and thermal efficiency Lightweight and easily cut to shape Easily fixed in place using standard tile adhesive F-Board-6 and -10 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 37

EHM Continued Technical Specification Compressive Strength 300kPa Flexural Strength (transverse) 600kPa Flexural Strength (longitudinal) 700kPa Thermal Conductivity 0.027 w/m K Water Absorption 0.2% by volume Temperature range -50 C to +75 C Fire Performance Class O (BS 476 part 6,7) Floorprep Primer & Roller Accessories UNDERFLOOR HEATING Floorprep Primer Suppresses dust and improves adhesion on a variety of sub-floor types including concrete and plywood. One bottle of Floorprep Primer covers approximately 6m² when diluted 1:1. Floorprep is easily applied using a Floorroll Roller. Not required when using F-Board insulated tile backer board EHM-R Kit - Cable Repair Kit (for emergency use only) For use when a heating cable has been cut usually during installation or by drilling through the floor. Cable Repair Kit EHM Standard Density Mats (160W/m²) - Specifications Model Volts kw Heated Area (m²) Mat Size (m) Weight (kg) EHM-07 230 0.07 0.5 0.9 x 0.5 0.6 EHM-13 230 0.13 0.8 1.6 x 0.5 0.8 EHM-21 230 0.21 1.3 2.6 x 0.5 1.0 EHM-26 230 0.26 1.6 3.2 x 0.5 1.2 EHM-34 230 0.34 2.1 4.2 x 0.5 1.4 EHM-41 230 0.41 2.6 5.2 x 0.5 1.6 EHM-50 230 0.50 3.1 6.1 x 0.5 2.0 EHM-56 230 0.56 3.4 6.7 x 0.5 2.1 EHM-67 230 0.67 4.2 8.3 x 0.5 2.5 EHM-81 230 0.81 5.1 10.2 x 0.5 3.0 EHM-100 230 1.00 6.2 12.3 x 0.5 3.5 EHM-121 230 1.21 7.5 15.1 x 0.5 3.7 EHM-140 230 1.40 8.8 17.6 x 0.5 4.0 EHM-180 230 1.80 11.0 22.0 x 0.5 5.2 EHM-215 230 2.15 13.3 26.6 x 0.5 6.5 EHM-260 230 2.60 16.3 32.5 x 0.5 8.5 38 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

High Density Mats (200W/m²) - Specifications Recommended for Conservatories Model Volts kw Heated Area (m²) Mat Size (m) Weight (kg) EHM-H41 230 0.41 2.1 4.1 x 0.5 1.4 EHM-H50 230 0.50 2.5 5.0 x 0.5 1.5 EHM-H56 230 0.56 2.8 5.6 x 0.5 1.7 EHM-H67 230 0.67 3.4 6.7 x 0.5 2.1 EHM-H81 230 0.81 4.1 8.1 x 0.5 2.4 EHM-H100 230 1.00 5.0 10.0 x 0.5 3.0 EHM-H121 230 1.21 6.1 12.1 x 0.5 3.5 EHM-H140 230 1.40 7.0 14.0 x 0.5 3.6 EHM-H180 230 1.80 9.0 18.0 x 0.5 4.2 EHM-H215 230 2.15 11.0 21.5 x 0.5 5.2 Thermostats Model Load Operation Sensor A16C 15A Manual Thermostat Air and floor or floor only U16C 15A Programmable Thermostat Air and floor or floor only T13CW 13A Programmable Touch Screen (White) Air and floor or floor only T13CS 13A Programmable Touch Screen (Silver) Air and floor or floor only Contactors UNDERFLOOR HEATING Model Amperage Max kw Enclosure Type CON-20 20 4.4 A CON-40 40 7.8 B CON-63 63 12 B ENCL-A Contactor Enclosure Type A ENCL-B Contactor Enclosure Type B Accessories for EHM Contactor and Enclosure Model Description Dimensions (mm) Area Covered (m²) F-Board-6 Insulation 1200 x 600 x 6 0.72 F-Board-10 Insulation 1200 x 600 x 10 0.72 Floorprep Primer 500ml (covers 6m² approx - diluted 1:1) Floorroll Roller for applying Primer EHM-R-Kit Cable Repair Kit (for emergency use only) web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 39

EHC Heating Cables An economic method of heating a room and providing a luxurious warm floor Manufactured to highest quality for complete peace of mind and backed by a 10 year warranty Ideally suited to small and irregularly shaped rooms Application Suitable for any room including conservatories, bathrooms and wet rooms Ideal for use with wide variety of floor surfaces including ceramic tiles, porcelain tiles, marble, slate, stone, carpet, vinyl, engineered wood and laminate flooring. UNDERFLOOR HEATING Features Twin core heating cable supplied with high adhesion tape Pre-wired 3m power lead Continuous earth braid Cable Specification Approved to EN60335-2-96 as required by the 17th Edition Wiring Regulations (BS7671.2008) EMC compliant 230V supply Twin core cable diameter 3mm to 4mm Earth screen protection by means of AL/PET Foil 10 Installation Tiled Floor The EHC heating cable should be installed in a flexible self-leveling compound or directly into the tile adhesive. It is important that the heating cable is completely covered. Other Floor Surfaces (carpet, vinyl, engineered wood and laminate floor) The EHC heating cable should be completely covered in a flexible self-leveling compound with the required floor surface applied once the compound is completely dry. Great care must be taken to ensure that fixing devices are not driven through the heating cable. Where underlay is required, the lowest tog option is recommended. If there is any doubt about the suitability of any given floor surface for use with underfloor heating, confirmation should be sought from the flooring supplier. Typical EHC Installation Electrical connections + thermostat Cold lead Tiles Tile adhesive Fixing tape Subfloor Heating cable 40 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Selection The objective is generally to cover as high a percentage of the free floor area as possible. The free floor area is defined as the floor area not occupied by permanent fixtures such as kitchen cabinets and shower trays. Use the table provided to select the correct cable. Large Rooms For large rooms it is common practice to use more than one heating cable. In these circumstances there is a choice of subdividing the room into separate zones each controlled by its own thermostat or connecting the heating cables together electrically in parallel and using a single thermostat. When controlling more than one heating cable from a single thermostat it may be necessary to incorporate a contactor into the control circuit. Control Thermostatic control must be used. BN Thermic offers a range of thermostats all of which are supplied with a floor probe. The thermostats can be configured for primary control via the built-in air sensor or via the floor sensor. When using more than one heating cable, check that the combined load of the heating cables is within the switching capacity of the selected thermostat. When the combined load is greater than the switching capacity of the selected thermostat an appropriately rated contactor must be selected. A16C Simplicity is the key. The A16C has a smart uncluttered appearance with a dial for temperature adjustment and an on/off switch. Capable of switching loads up to 3.4kW, the A16C is configurable for air and floor sensor or floor sensor only U16C The U16C offers simple 7-day programming with programming buttons hidden behind hinged doors on the thermostat face. Capable of switching loads up to 3.4kW, the U16C is configurable for air and floor sensor or floor sensor only. Features include a backlit screen and a summer switch allowing the heating to be switched off without losing the programme. A16C UNDERFLOOR HEATING T13C Using the latest touch screen technology, the T13C is the state of the art underfloor heating thermostat. It offers an unrivalled modern appearance coupled with ultra-simple 7-day programming and can be easily configured for air and floor or floor only control. The T13C can switch loads of up to 3kW and is a available in a choice of white (T13CW) or silver (T13CS) finishes. U16C F-Board Insulation T13CW T13CS To limit downward heat loss and to significantly improve the economy of an underfloor heating system, the use of F-Board insulated tile backer boards is highly recommended. Installed directly onto the sub-floor and below the heating cable, they provide exceptional thermal insulation with minimal increase in floor height. F-Board insulated tile backer boards are generally held in place using standard tile adhesive. Selection Each F-Board covers 0.72m² and sufficient boards should be selected to completely cover the floor area. Total floor area (m²) 0.72 = minimum number of boards required F-Board-6 Provides an extremely effective insulation barrier where floor build-up must be kept to a minimum. F-Board-10 As the effectiveness of insulation increases with thickness, F-Board-10 should be selected where maximum economy is required and additional floor build-up is acceptable. F-Board-6 and -10 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 41

EHC Continued Features Floorprep Primer & Roller Full resistance to moisture absorption Combination of low profile, strength and thermal efficiency Lightweight and easily cut to shape Easily fixed in place using standard tile adhesive Technical Specification Compressive Strength 300kPa Flexural Strength (transverse) 600kPa Flexural Strength (longitudinal) 700kPa Thermal Conductivity 0.027 w/m K Water Absorption 0.2% by volume Temperature range -50 C to +75 C Fire Performance Class O (BS 476 part 6,7) Cable Repair Kit UNDERFLOOR HEATING Accessories Floorprep Primer Suppresses dust and improves adhesion on a variety of sub-floor types including concrete and plywood. One bottle of Floorprep Primer covers approximately 6m² when diluted 1:1. Floorprep is easily applied using a Floorroll Roller. Not required when using F-Board insulated tile backer board EHM-R Kit - Cable Repair Kit (for emergency use only) For use when a heating cable has been cut usually during installation or by drilling through the floor. EHC Heating Cables - Specifications Model Volts kw Heated Area (m²) Cable Length (m) Weight (kg) EHC-012 230 0.12 0.7 1.0 11 1.1 EHC-020 230 0.20 1.1 1.5 19 1.2 EHC-025 230 0.25 1.6 2.0 24 1.4 EHC-032 230 0.32 2.1 2.5 32 1.6 EHC-040 230 0.40 2.6 2.9 37 1.7 EHC-045 230 0.45 3.0 3.3 46 2.0 EHC-052 230 0.52 3.4 3.8 50 2.4 EHC-060 230 0.60 3.9 4.5 64 2.7 EHC-075 230 0.75 4.6 6.0 76 2.9 EHC-095 230 0.95 6.1-7.5 87 3.2 EHC-110 230 1.10 7.6 8.5 115 4.0 EHC-130 230 1.30 8.6 10.0 131 4.8 EHC-170 230 1.70 10.1 13.0 159 6.3 EHC-200 230 2.00 13.1 15.5 194 8.4 42 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Thermostats Model Load Operation Sensor A16C 15A Manual Thermostat Air and floor or floor only U16C 15A Programmable Thermostat Air and floor or floor only T13CW 13A Programmable Touch Screen (White) Air and floor or floor only T13CS 13A Programmable Touch Screen (Silver) Air and floor or floor only Contactors Model Amperage Max kw Enclosure Type CON-20 20 4.4 A CON-40 40 7.8 B CON-63 63 12 B ENCL-A Contactor Enclosure Type A ENCL-B Contactor Enclosure Type B Accessories for EHC Model Description Dimensions (mm) Area Covered (m²) F-Board-6 Insulation 1200 x 600 x 6 0.72 F-Board-10 Insulation 1200 x 600 x 10 0.72 Floorprep Primer 500ml (covers 6m² approx - diluted 1:1) Floorroll Roller for applying Primer EHM-R-Kit Cable Repair Kit (for emergency use only) Contactor and Enclosure UNDERFLOOR HEATING Free Underfloor Heating Design Service Let BN Thermic help plan your underfloor heating system. Just photocopy this page, add the requested information as possible and fax or email it to our sales office. We will provide a detailed quotation by return. Type of Room (e.g. conservatory): Type of sub-floor (e.g. concrete): Floor surface (e.g. ceramic tiles): Enquiry From Please provide a dimensioned sketch showing areas occupied by permanent fixtures such as kitchen cabinets (for larger rooms feel free to use a separate sheet). Tel Fax Email web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 43

LH Heating for laminate and engineered wood floors Providing an economic method of heating a room and providing a luxurious warm floor Easily and quickly installed under laminate and engineered wood floors without the need for adhesives or compounds Manufactured to highest quality for complete peace of mind and backed by a 10 year warranty Application Suitable for any room except bathrooms and wet rooms Specifically designed for use with laminate or engineered wood floors UNDERFLOOR HEATING Features Low profile system, combined thickness of insulation/underlay, heating and vapour barrier is approximately 7mm Two widths of heating film and a wide range of lengths for good floor coverage in any size of room Pre-wired 4m power leads LH heating films can be easily reduced in length during the installation process Film Specification Approved to EN60335-2-96 as required by the 17th Edition Wiring Regulations (BS7671.2008) EMC compliant 230V supply Polyester film less than 1mm thick Installation Three layers are required: DEP6 10 1st Layer DEP6 Insulation/Underlay The entire floor area must be covered by a 6mm thick layer of DEP6. This layer performs four functions. Thermal insulation limiting downward heat loss A moisture proof barrier between the heating film and the sub-floor Sound deadening A non-abrasive surface onto which the heating film can be installed 2nd Layer LH Film A number of LH heating films are installed side by side to fill the floor area The heating films are electrically connected in parallel and controlled by a single thermostat LH Film Roll 3rd Layer VB Vapour Barrier The entire floor must be covered in a layer of VB vapour barrier. This layer performs three functions Secondary electrical insulation Protection from major liquid spills A mechanical barrier between the heating film and the floor surface preventing abrasion DEP6, LH Film and VB should all be secured using LHT High Adhesive Tape. One 50m roll is required for each 10m² of floor area. VB Vapour barrier LHT High Adhesive Tape 44 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Selection Step One Step Two Step Three Control Draw a plan of the room identifying areas occupied by permanent fixtures such as kitchen cabinets Draw the heating films side by side onto the plan keeping all electrical connections along one wall wherever possible. For ease of installation we suggest using a small number of wider films rather than a larger number of narrower films. Frequently a combination of wider and narrower films will be required. Should you select a film slightly too long for the room, it is a simple process to reduce the length of the film during installation. Select the correct number of DEP6 insulation/underlay boards and VB vapour barriers to cover the entire floor area. Both DEP6 and VB must be used in the installation. Electrical connections + thermostat Live + Neutral Cables Typical LH Installation Cold lead Built-in Wardrobe Thermostatic control must be used. BN Thermic offers a range of thermostats all of which are supplied with a floor probe. The thermostats can be configured for primary control via the built-in air sensor or via the floor sensor. For larger rooms, check that the combined load of the heating films is within the switching capacity of the selected thermostat. When the combined load is greater than the switching capacity of the selected thermostat an appropriately rated contactor must be selected. UNDERFLOOR HEATING A16C Simplicity is the key. The A16C has a smart uncluttered appearance with a dial for temperature adjustment and an on/off switch. Capable of switching loads up to 3.4kW, the A16C is configurable for air and floor sensor or floor sensor only U16C The U16C offers simple 7-day programming with programming buttons hidden behind hinged doors on the thermostat face. Capable of switching loads up to 3.4kW, the U16C is configurable for air and floor sensor or floor sensor only. Features include a backlit screen and a summer switch allowing the heating to be switched off without losing the programme. T13C Using the latest touch screen technology, the T13C is the state of the art underfloor heating thermostat. It offers an unrivalled modern appearance coupled with ultra-simple 7-day programming and can be easily configured for air and floor or floor only control. The T13C can switch loads of up to 3kW and is a available in a choice of white (T13CW) or silver (T13CS) finishes. T13CW A16C U16C T13CS web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 45

LH Continued LH Heating for Laminate & Engineered Wood Floors - Specifications UNDERFLOOR HEATING Model Volts kw Dimensions (m) W L LH4-010 230 0.04 0.4 1.0 LH4-015 230 0.06 0.4 1.5 LH4-020 230 0.09 0.4 2.0 LH4-025 230 0.11 0.4 2.5 LH4-030 230 0.13 0.4 3.0 LH4-035 230 0.15 0.4 3.5 LH4-040 230 0.17 0.4 4.0 LH4-045 230 0.19 0.4 4.5 LH4-050 230 0.21 0.4 5.0 LH4-060 230 0.26 0.4 6.0 LH4-070 230 0.30 0.4 7.0 LH4-080 230 0.34 0.4 8.0 LH4-090 230 0.39 0.4 9.0 LH4-100 230 0.43 0.4 10 LH10-010 230 0.13 1.03 1.0 LH10-015 230 0.19 1.03 1.5 LH10-020 230 0.26 1.03 2.0 LH10-025 230 0.32 1.03 2.5 LH10-030 230 0.39 1.03 3.0 LH10-035 230 0.45 1.03 3.5 LH10-040 230 0.52 1.03 4.0 LH10-045 230 0.58 1.03 4.5 LH10-050 230 0.65 1.03 5.0 LH10-060 230 0.78 1.03 6.0 LH10-070 230 0.91 1.03 7.0 LH10-080 230 1.04 1.03 8.0 LH10-090 230 1.17 1.03 9.0 LH10-100 230 1.30 1.03 10 Laminate floor VB Vapour barrier LH Film DEP6 Insulation Subfloor 46 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Thermostats for LH Model Load Operation Sensor A16C 15A Manual Thermostat Air and floor or floor only U16C 15A Programmable Thermostat Air and Floor T13CW 13A Programmable Touch Screen (White) Air and floor or floor only T13CS 13A Programmable Touch Screen (Silver) Air and floor or floor only Contactors for LH Model Amperage Max kw Enclosure Type CON-20 20 4.4 A CON-40 40 7.8 B CON-63 63 12 B ENCL-A Contactor Enclosure Type A ENCL-B Contactor Enclosure Type B Accessories for LH Model Description Dimensions (mm) Area Covered (m²) DEP-6 Insulation 1200 x 600 x 6 0.72 VB Vapour Barrier 4000 x 3000 12 LHT 50m High Adhesive Tape (one roll for 10m² floor area) MD Mirror Demister Pads Providing a mist free mirror 100% effective in little over 2 minutes Very low energy consumption Simply integrated into the lighting circuit ensuring that they are not left running UNDERFLOOR HEATING Features Protects an area approximately 20% larger than the pad itself Double insulated and completely sealed for total safety Less than 1mm thick Peel off adhesive backing 1m long power lead Selection MD MIrror Demister Pads - Specifications Model Volts Watts Dimensions (mm) MD-12 230 12 252 x 274 MD-28 230 28 574 x 274 MD-50 230 50 519 x 524 MD-100 230 100 1004 x 524 Peel-off adhesive backing web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 47

CCSRJ Self Regulating Water Pipe Freeze Protection Cable Prevents water from freezing in metal and plastic pipes Avoids the cost and inconvenience of burst pipes Self regulating technology and recommended thermostatic control ensures lowest possible running costs Typical Applications Stables Sprinkler systems Features Self regulating technology ensures that cable output will decrease as ambient temperature increases Can be cut to length, terminated, T jointed and spiced on site using the BN Thermic s termination and splice kits Can be double wrapped to protect valves, flanges etc. without risk of creating hot spots Fully moisture proof with full length earth braid PIPE FREEZE PROTECTION Controlling CCSRJ Self Regulating Pipe Freeze Protection cable Although the cable s self regulating technology ensures that cable output will decrease as ambient temperature increases, thermostatic control is still recommended. A master frost thermostat will prevent the low level of electricity consumption that would otherwise occur when the ambient temperature was above freezing point. BN Thermic offers a choice of two frost thermostats. The FST-EX should be selected for outdoor applications or where a tamperproof device is preferred. Both thermostats have a switching capacity of 10A. Larger loads can be switched via a suitably rated contactor. Notes on Selection and Installation FST-IN Use the following tables to select the correct output and length of cable required for your FST-EX application. You will notice that in most instances a straight run of cable will suffice. The table also indicates the thickness of the insulation which should cover both pipe and cable. A CCSRJ-T1 termination kit will be required per circuit with one CCSRJ-S splice kit required for every splice or T CCSRJ-T Termination Kit CCSRJ-S Splice kit Plastic pipes should be wrapped in AL50 aluminium tape before installing the cable Maximum circuit lengths are as follows: CCSRJ-10: 164m CCSRJ-24: 106m BN Thermic PF-L warning labels should be applied to the outside of the insulation PF-L Caution Labels 48 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

CCSRJ Pipe Freeze protection Cable - Specifications Model Volts W/m Description CCSRJ-10 230 10 75m dispensing box CCSRJ-10-CL 230 10 Available by the metre Max 30m CCSRJ-24 230 24 75m dispensing box CCSRJ-24-CL 230 24 Available by the metre Max 30m CCSRJ-T1 Termination kit CCSRJ-T5 Termination kit pack of 5 CCSRJ-S Splice/Tee kit PF-L Caution label pack of 10 CCSRJ Selection Table 1 (minimum ambient temperature -20 C) CCSRJ Selection Table 2 (minimum ambient temperature -20 C) Pipe Diameter (mm) 12 25 50 75 100 150 Insulation Thickness (mm) 12 25 50 CCSRJ-10 Straight CCSRJ-24 Straight CCSRJ-24 Straight CCSRJ-24 1.3m cable/1m pipe CCSRJ-24 1.8m cable/1m pipe CCSRJ-24 3m cable/1m pipe CCSRJ-10 Straight CCSRJ-10 Straight CCSRJ-10 Straight CCSRJ-24 Straight CCSRJ-24 Straight CCSRJ-24 1.4m cable/1m pipe CCSRJ-10 Straight CCSRJ-10 Straight CCSRJ-10 Straight CCSRJ-10 Straight CCSRJ-24 Straight CCSRJ-24 1.2m cable/1m pipe Pipe Diameter (mm) Additional Cable Length (m) Pair of Flanges Valve Support 12 0.23 0.10 0.10 25 0.28 0.15 0.10 50 0.30 0.30 0.15 75 0.45 0.40 0.15 100 0.60 0.50 0.20 150 0.80 0.60 0.25 PIPE FREEZE PROTECTION Recommended frost thermostats Model Description Full Details on page FST-IN Frost Thermostat Indoor Use (10A) 56 FST-EX Frost Thermostat Outdoor Use (10A) 57 CCSRJ-10 75m drum web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 49

PGE Pre-terminated Water Pipe Freeze Protection Cable Prevents water from freezing in metal and plastic pipes Avoids the cost and inconvenience of burst pipes Simple low cost product for quick installation Typical Applications Mobile homes Domestic installation Features Pre-terminated with 2m cold lead for connection to standard plug or into a suitable junction box Built-in thermostat automatically energises the cable when pipe temperature falls below 3 C Fully moisture proof Controlling PGE Self Regulating Pipe Freeze Protection Cable The PGE s built-in thermostat means that no additional control device is required PIPE FREEZE PROTECTION Notes on Selection and Installation PGE is designed to protect metal and plastic pipes with a diameter up to 40mm assuming a minimum ambient temperature of -20 C The pipe must always be full of water and never heated above 66 C The PGE cable should be run in a straight line along the pipe an secured at approximately 600mm intervals with PGE-FT tape The thermostat must be positioned at the colder end of the pipe It is vital that the cable is not allowed to PGE-02 complete overlap The entire installation should be covered with 13mm flame retardant insulation BN Thermic PF-L warning labels should be applied to the outside of the insulation Plastic pipes should be wrapped in AL50 aluminium tape before installing the cable PGE Pipe Freeze Protection Cale - Specifications Model Volts Watts Heated Length Weight (kg) (m) PGE-01 230 17 1 0.4 PGE-02 230 35 2 0.5 PGE-04 230 71 4 0.6 PGE-08 230 117 8 0.8 PGE-12 230 187 12 1.0 PGE-14 230 230 14 1.1 PGE-18 230 275 18 1.3 PGE-24 230 373 24 1.5 PGE-37 230 550 37 2.3 PGE-49 230 735 49 3.0 PF-L Caution label pack of 10 AL50 45m x 50mm aluminium tape PGE-FT PGE Flame Retardant Fixing Tape 33m x 19mm PF-L Caution Labels AL50 Aluminium Tape PGE-FT Fixing Tape 50 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

HC Hard Case Thermostats Energy Saving Tamperproof Thermostats Energy saving thermostats because only authorised personnel can adjust temperature settings Vandal resistant design suitable for public areas Highly accurate electronic temperature control ensures lowest possible heating costs Top quality products backed by 5 year warranty Typical Applications Controlling BN Thermic heating systems such as OUH Industrial Unit Heaters and ESN Black Heat Radiant Cassettes Accurate temperature control in shops, warehouses, schools, sports halls etc An integral component in a programmable heating system Features Common to all Models Tamperproof design requires a special tool (HC-D) to adjust temperature settings Electronic control accurate to within +/- 0.5 C Super robust vandal resistant die-cast aluminium enclosure Choice of integral or remote sensor Black sensor ideally suited for control of radiant heating systems HC-T1 and HC-T1/R Standard Thermostat Application Basic comfort temperature control Features specific to HC-T1 and HC-T1/R Adjustable range: 12 to 25 C Output Switch Rating 16A Output Switch Changeover Adjustable Differential 0.25 C to 5 C Power Supply 230V Dimensions 120 x 95 x 36.5 Weight 0.33kg HC-T1 has a built-in sensor HC-T1/R is for use with either the HC-S1 or HC-SW1 remote sensor HC-TF1 and HC-TF1/R Standard Frost Thermostat Application Frost protection control Features specific to HC-TF1 and HC-TF1/R Adjustable range: 0 C to 11 C Output Switch Rating 16A Output Switch Changeover Adjustable Differential 0.25 C to 5 C Power Supply 230V Dimensions 120 x 95 x 36.5 Weight 0.33kg HC-TF1 has a built-in sensor HC-TF1/R is for use with either the HC-S1 or HC-SW1 remote sensor CONTROLS web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 51

CONTROLS HC-ST1 and HC-ST1/R Set-Back Thermostat with Integral Run-Down Timer Application The HC-ST1 has two settings: high (comfort) and low (set-back). The default setting is low (set-back). The HC-T1 incorporates a simple push button which changes the set-point from low (set-back) to high (comfort) for a pre-programmed period of time (½, 1, 2 or 4 hours). Once this period of time has elapsed the thermostat will automatically revert to its low (setback) setting. This method of control is ideal for irregularly used facilities such as community halls where the set-back setting will provide frost protection while the hall is unoccupied. Features specific to HC-ST1 and HC-ST1/R Adjustable range: 12 to 25 C Adjustable set-back Up to 15 C below high temperature setting Output Switch Rating 16A Output Switch Changeover Adjustable Differential 0.25 C to 5 C Power Supply 230V Dimensions 120 x 95 x 36.5 Weight 0.33kg HC-ST1 has a built-in sensor HC-ST1/R is for use with either the HC-S1 or HC-SW1 remote sensor HC-SR1 and HC-SR1/R Set-Back Thermostat for use with Remote Timer Application The HC-SR1 has two settings: high (comfort) and low (set-back) and requires a remote signal to switch between one and the other. Typically this signal is provided by a remote mounted 24 hour/7 day programmable timer (TIM-D1) that will ensure that the heating system operates at its low (set-back) setting, providing frost protection while a building is unoccupied (typically at night and at weekends). The programmable timer has a built-in run-down clock that is triggered by a remote mounted boost button (HC-B1). This feature will provide a temporary temperature boost for a pre-determined length of time during a period when the system would normally be in set-back mode. The boost command can be cancelled by depressing the boost button for 3 seconds. This system is ideal for premises that have a regular pattern of use but may occasionally be used outside normal hours. See pages 55 for details of timer and boost button Features specific to HC-SR1 and HC-SR1/R Adjustable range: 12 to 25 C Adjustable set-back Up to 15 C below high temperature setting Output Switch Rating 16A Output Switch Changeover Adjustable Differential 0.25 C to 5 C Power Supply 230V Dimensions 120 x 95 x 36.5 Weight 0.33kg HC-SR1 has a built-in sensor HC-SR1/R is for use with either the HC-S1 or HC-SW1 remote sensor 52 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

Sensors For use with Hard Case Thermostats with Suffix R HC-S1 Standard Sensor Standard black sensor, ideal for use with a radiant heating system, mounted onto a small white terminal enclosure. For standard indoor applications. Dimensions: 74 x 51 x 28 HC-S1 HC-SW1 Weatherproof Sensor Weatherproof sensor conforming to IP55. A black temperature sensor, ideal for use with radiant heating system, mounted onto a grey weatherproof ensclosure and resistant to water sprayed from all directions. Dimensions: 105 x 105 x 55 HC-SW1 HC-D Special Tool for Removing Tamperproof Screws The key to the Hard Case energy saving potential is the HC-D. Without this device it is impossible to adjust temperature settings. This ensures that changes are only made by authorised personnel and prevents casual or willful adjustments being made. HC-D Special Tool for Tamperproof Screws HC Hard Case Thermostats Model Description HC-T1 Standard Thermostat HC-T1/R Standard Thermostat /Remote Sensor HC-TF1 Frost Thermostat HC-TF1/R Frost Thermostat/Remote Sensor HC-ST1 Set-Back Thermostat with Run-Down Timer HC-ST1/R Set-Back Thermostat with Run-Down Timer/ Remote Sensor HC-SR1 Set-Back Thermostat for use with External Timer HC-SR1/R Set-Back Thermostat for use with External Timer/ Remote Sensor HC-S1 Standard Remote Sensor HC-SW1 Weatherproof Sensor IP55 HC-D Special Tool for Removing Tamperproof Screws CONTROLS web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 53

TIMERS BN Thermic s range of timers has been devised to ensure the lowest possible running costs for a heating system. TS-3 Pre-programmed Push Button Timer Application Generally used with shortwave radiant heaters such a BN Thermic s HWP2 patio heaters An energy saving device preventing shortwave heaters being energised unnecessarily Safe to install and leave outdoors Specification Mounting Adjustable Time Delay Switching Capacity Surface 2 minutes to 2 hours 16A 230V (larger loads and 3-phase loads can be switched via a suitable rated contactor) 230V Single pole, single throw Voltage Supply Contacts Dimensions 85 x 85 x 67 Ingress protection: IP66 Special Features Blue locator light illuminated when heating off Red LED indicates 1 minute of operation remaining CONTROLS TS-4 Push Button Timer (User Selectable Time Delay) Application Generally used with shortwave radiant heaters such a BN Thermic s HN Series Shortwave Infrared Heaters An energy saving device preventing shortwave heaters being energised unnecessarily For indoor use in facilities such as school buildings and community halls Specification Mounting Recessed into 25mm (minimum) back-box Time Delay User selects 15 minute/ 30 minute / 1 hour / 2 hour Switching Capacity 13A 230V (larger loads and 3-phase loads can be switched via a suitable rated contactor) Voltage Supply 230V Contacts Single pole, single throw Dimensions 85 x 85 x 31 Ingress protection: IP20 Special Features LED indicates 2 minutes of operation remaining Time setting can be changed at any time during cycle Provides a means of switching off heating 54 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

TIM-D1 24 Hour/7 Day Programmable Timer Application Ideal for use with BN Thermic s range of Hard Case Tamperproof Thermostats to provide economic and yet adaptable heating control packages Features Daily and weekly programmes Display Illumination (can be switched off) Memory card supplied as standard (can be used for programme override) PIN protection (optional) Date controlled holiday programme Integral count-down timer with run time up to 23 hours 59 minutes and activated by TIM-D1 and TIM-B1 remote push button. When used with a Hard Case Thermostat, the TIM-B1 Push Enclosure TIM-E1 Button will provide a boost to comfort temperature during a period when the system is in off or set-back mode. Once the pre-programmed run time has elapsed, the system will revert to the programme. The boost signal can be cancelled by depressing the TIM-B1 Push Button for 3 seconds. Dimensions: 86 x 35 x 66 Optional terminal cover TIM-E1 TIMERS Model Description TS-3 Pre-programmed Push Button Timer TS-4 Push Button Timer (User Selectable) TIM-D1 TIM-E1 TIM-B1 Programmable Timer Terminal enclosure for TIM-D1 timer Push Button for use with TIM-D1 (provides temporary boost) TIM-B1 Push Button CONTROLS Typical BN Thermic Control System HIGH LOW TIM B1 Push Button For temporary boost TIM D1 Programmable timer HC-SR1 Tamperproof thermostat with high-low settings CON Contactor selected to suit heating load ESN Group of black heat radiant cassettes web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 55

THERMOSTATS BN Thermic offers a range of thermostats to meet the requirements of a wide range of commercial and industrial heating applications. For tamperproof and vandal resistant thermostats please see our Hard Case range on page 51 RST-IN Thermostat for Comfort Heating Applications Application The RST-IN is a simple wall-mounted thermostat suitable for controlling a variety of space heaters Specification Adjustable Range +5 C to +30 C Mounting Surface Switching Capacity 10A 230V (larger loads and 3-phase loads can be switched via a suitable rated contactor) Voltage Supply 230V Contacts Single pole, change over Dimensions 74 x 74 x 23 Ingress protection: IP30 Special Features Integral heat anticipator improves control accuracy Adjustable range can be limited or locked RST-EX Thermostat suitable for Damp Conditions CONTROLS Application The RST-EX has a high IP rating making it suitable for applications such as plant rooms and water treatment works Specification Adjustable Range +5 C to +35 C Mounting Surface Switching Capacity 15A 230V (larger loads and 3-phase loads can be switched via a suitable rated contactor) Voltage Supply None Required Contacts Single pole, change over Dimensions 105 x 105 x 60 Ingress protection: IP54 FST-IN Frost Thermostat Application The FST-IN will provide accurate control at low temperatures and is ideal for use with pipe freeze protection cables Specification Adjustable Range -20 C to +30 C Mounting Surface Switching Capacity 10A 230V (larger loads and 3-phase loads can be switched via a suitable rated contactor ) Voltage Supply 230V Contacts Single pole, change over Dimensions 74 x 74 x 23 Ingress protection: IP30 Special Features Integral heat anticipator improves control accuracy Adjustable range can be limited or locked 56 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

FST-EX Frost Thermostat for Outdoor Use Application The FST-EX will provide accurate control at low temperatures and is ideal for use with pipe freeze protection cables. A high IP rating means that this device is suitable for outdoor use. Specification Adjustable Range -20 C to +30 C Mounting Surface Switching Capacity 10A 230V (larger loads and 3-phase loads can be switched via a suitable rated contactor) Voltage Supply 230V Contacts Single pole, change over Dimensions 125 x 125 x 75 Ingress protection: IP65 Special Features Integral heat anticipator improves control accuracy Adjustable range can be limited or locked Cover must be removed to allow set-point adjustment PROSTAT-7 Programmable Thermostat Application By controlling both air temperature and the hours of operation, the PROSTAT-7 ensures maximum economy in a wide variety of commercial applications. A simple override facility provides a quck boost to comfort levels when the thermostat would normally be in set-back mode. Specification Adjustable Range +5 C to +30 C Mounting Surface Switching Capacity 6A 230V (larger loads and 3-phase loads can be switched via a suitable rated contactor) Voltage Supply 3 x AA batteries (supplied) Contacts Single pole, change over Dimensions 142 x 71 x 30 Ingress protection: IP30 Special Features Battery life in excess of 2 years Up to 6 programmable events per day Temporary temperature override until next preset period Temperature lock permanent temperature override until reset CONTROLS Thermostats - Specifications Model Description Dimensions (mm) H W D RST-IN Room thermostat general purpose 10A 74 74 23 RST-EX Thermostat weather resistant (IP54) 15A 105 105 60 FST-IN Frost thermostat indoor use 10A 74 74 23 FST-EX Frost thermostat outdoor use (IP65) 10A 125 125 75 PROSTAT-7 7 day programmable thermostat using 3 x AA 71 142 30 batteries (supplied) 8A web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 57

CONTROLS Miscellaneous Control Devices A range of control devices additional to BN Thermic s thermostat and timer ranges CS-1 Wall Mounted Controller Application The CS-1 controller has been developed specifically for use with BN Thermic s 700, SCH, CHS and RH range of commercial fan assisted heaters Specification Mounting Surface Switching Manual Settings On/Off/High Heat/Low Heat/Fan-only Voltage Supply 230V Dimensions 90 x 149 x 45 Ingress protection: IP30 WH-402 Movement Sensor Application Ideal for use with shortwave halogen heaters, the WH-402 improves economy switching off heating when no movement is detected. It is suitable for both indoor and outdoor use. CONTROLS Specification Mounting Surface Switching Capacity 16A 230V (larger loads and 3-phase loads can be switched via a suitable rated contactor) Voltage Supply 230V Sensing Range 12m 180 (both distance and angle can be reduced) Time Delay 5 seconds to 18 minutes (adjustable) Dimensions 65 x 83 x 115 Ingress protection: IP55 VR-1 Dimmer Switch Application Specifically designed for use with radiant heaters, the VR-1 provides fine adjustment of a heat intensity. Specification Mounting Surface Output adjustment 0% to 100% Switching Capacity 13A 230V (shortwave infrared heaters up to 3kW 230V) Voltage Supply 230V Dimensions 86 x 147 x 69 Ingress protection: IP20 NOT SUITABLE FOR OUTDOOR USE Special Features Definite click to off. Controls - Specifications Model Description Dimensions (mm) H W D CS-1 Wall mounted controller 90 149 45 high heat/low heat/fan-only WH-402 Movement sensor PIR 16A. Outdoor use IP55 65 83 115 VR-1 Dimmer switch 13A 86 147 69 58 web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432

CON Contactors Contactors allow a thermostat or similar switching device to switch large single phase or three phase loads. (230V coil resistive loads only) ENCL-C CON-20 mounted in ENCL-A enclosure CONTROLS CON-50-3 CON-50-3 mounted in ENCL-C enclosure on DIN rail Contactors - Specifications Model Phases Amperage/Phase Max kw/phase Enclosure Type CON-20 1 20 4.4 A CON-40 1 40 7.8 B CON-63 1 63 12 B CON-30-3 3 30 6 C CON-45-3 3 45 9.8 C CON-80-3 3 80 16 D CON-110-3 3 110 23 D ENCL-A Contactor Enclosure Type A ENCL-B Contactor Enclosure Type B ENCL-C Contactor Enclosure Type C ENCL-D Contactor Enclosure Type D web www.bnthermic.co.uk email sales@bnthermic.co.uk tel +44 (0)1293 547361 fax +44 (0)1293 531432 59

Contact us for technical advice, free designs or detailed quotation BN Thermic Ltd 34 Stephenson Way Three Bridges Crawley West Sussex RH10 1TN Tel 01293 547361 Fax 01293 531432 Email sales@bnthermic.co.uk Web www.bnthermic.co.uk