Thermostatic mixing valves. Pegler Yorkshire

Similar documents
In-line thermostatic mixing valves

ANTI-SCALD THERMOSTATIC MIXING VALVES PUTTING YOU IN CONTROL

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

The Safety Valve Specialist TMV2. Thermostatic Mixing Valves. Engineered to a high specification, designed for safety and comfort

The Safety Valve Specialist Thermostatic Shower Controls

Dual Control Thermostatic Bath and Shower Mixer

The Safety Valve Specialist TMV3. Thermostatic Mixing Valves. Engineered to a high specification, designed for safety and comfort

Thermostatic Bath Shower Mixer. Without shower kit.

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

Horne Engineering Ltd INSTALLATION, COMMISSIONING, OPERATING AND MAINTENANCE INSTRUCTIONS

Telo Shower Mixing Valve TL10016CP

Intatherm Safe Touch Basin Tap IT1008CP

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

CATALOGUE NUMBERS. Pressure Reducing Valve (PRV)** Mains Supply. Cold Water Outlets

Shower Panels with a Thermostatic Sequential Control

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

FOR INSTALLING AND USING

Varsity Concealed Shower System

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Installation Instructions. Hansgrohe S 15721XXX

Thermostatic Bar Valves

Installation Instructions

Heating Controls Thermostatic and Manual Radiator Valve range

Installation Instructions. Starck

Puro Mini Dual Control Shower Mixer PU90010CP

Kiko Bath Shower Mixing Valve KK90015CP

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Infra Red Thermostatic Wall Mixer

Plus Bath Shower Mixing Valve CP and PL30020CP

The New Caroma TMV20

Inta City Concealed Shower Mixing Valve CT80010CP

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

AQUABLEND 1500 SOLAR THERMOSTATIC MIXING VALVE

Inta City Shower Mixing Valve CT20010CP

SUPERIOR QUALITY HEAT INTERFACE UNITS PUTTING YOU IN CONTROL. Pegler Yorkshire

Mio Concealed Shower Mixing Valve MI40010CP

Self-help Temperature Adjustment

Deluge Shower Mixing Valve 10045CP

INSTALLATION INSTRUCTIONS

Enzo Safe Touch Thermostatic Shower EZ20011CP & EZ20012CP

Kiko Concealed Shower Mixing Valve KK80010CP

Komo Thermostatic Bar Shower. Excluding Shower Kit

The new Terrier Belmont Thermostatic Radiator Valve range

Installation Instructions Thermostatic Bar Shower Valve ALTO ECOTHERM

Solutions brought to you by Hurlstones. Solutions brought to you by Hurlstones. shower panel specification manual 2012

THE BRAND NEW UTILITY TAPS RANGE

WASHROOM SYSTEMS. PRODUCT GUIDE WATER CONTROLS FOR A MODERN WORLD HEATING SYSTEM COMPONENTS HEATING & COOLING DISTRIBUTION SYSTEMS

Pegler Yorkshire reserve the right to change specifications. 10 Year Guarantee Luxury Taps and Mixers

About Legionella. What is Legionella? TMV solution. Recommendations. Economix & ES Range. VTM Range. PREMIX Range

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

Euromixer Thermostatic Mixing Valves

Installation Instructions and User Guide

Thermostatic mixing valve VADO-PRO-100P

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Dual Control Concealed & Exposed Thermostatic Shower Valve

Deluge Concealed Shower Mixing Valve DL40010CP

Basin Tap. Time delay maximum 2 seconds

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

shower panel specification manual 2008

Varsity Exposed Shower Systems

SHOWER TECHNICAL SPECIFICATION

THERMOSTATIC SHOWER VALVE

Brassware 1:5:0. Selector. Modern 1:5:1. Contract 1:5:2. Kitchen 1:5:3. Icon key. Brassware. Blue Book Armitage Shanks. Residential.

INSTALLATION INSTRUCTIONS

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

THE BATHROOM COLLECTIONS

aquablend thermostatic mixing valves

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Code Description Dimensions 4P1061 RUNE CP MONOBLOC DUALFLOW SINK MIXER see image. Operating Pressure (bar)

Installation Instructions Flute Tap Range

INSTALLATION INSTRUCTIONS

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

Thermostatic mixing valves with replaceable cartridge for centralized systems

BENITO Bar Mixer Shower

GaLvaniZEd STEEL. STainLESS STEEL. Sprinkler systems. Pegler Yorkshire

AQUAFIT - the innovative single-lever mixer for safety and hygiene

Thermomix Underfloor Heating Control Pack

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

INTADUO THERMOSTATIC BATH/SHOWER MIXER

MERSEY sequential exposed thermostatic mixer shower

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Thermostatic mixing valves with interchangeable cartridges

Summer Works Scheme 2010

Unvented water heating

Uniclass L725111:D4 EPIC H32. CI/SfB 4 (53.9) X. thermostatic tap specification manual OPTITHERM

TOP 100 WATER SAVING PRODUCTS

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

INSTALLATION INSTRUCTIONS

Target Monobloc Kitchen Mixer Chrome

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Eden Bath Shower Mixer

Unvented Water Heaters. September Aqualine. Unvented Electric Water Heating

Transcription:

Thermostatic Pegler Yorkshire

Pegler Yorkshire Unrivalled quality, innovation, customer service and long-term value for money As part of the global Aalberts Industries NV Group, Pegler Yorkshire is one of Britain s largest and most respected manufacturers of innovative market-leading products for today s ever more demanding and diverse plumbing and heating industries. Behind every one of the company s very extensive portfolio of famous brand names are two unparalleled key benefits: more than two hundred years of priceless expertise and experience combined with continuous investment in research, development, new technology, advanced production facilities and, of course, in people dedicated to the task. Hence Pegler Yorkshire s ability to not only sustain but to build upon a reputation the world over for exceptional quality, performance, reliability and whole-life value for money. Increasingly, Pegler Yorkshire s substantial resources are also focused on developing solutions which, where possible, address crucial environmental issues such as saving water and reducing energy consumption at every opportunity. So when you purchase or specify any of our tried and trusted products, you are acquiring far more than a means of simply doing a job. You are guaranteeing a job very well done every time. And all backed by impeccable customer service, training and technical support, with comprehensive warranties and long term parts availability. Standards At Pegler Yorkshire we are dedicated to designing, developing and manufacturing products of the highest quality. We are members of numerous standards committees and take an active part in their development. Our products, where applicable, comply with the relevant British, European and International standards. Whatever the latest developments, we guarantee that our products will always meet the latest and highest standards. Trade bodies Pegler Yorkshire is pleased to be associated with several influential organisations within the industry. Association of Plumbing and Heating Contractors Brass The Brass Page for specifiers, designers, engineers and manufacturers The Bathroom Manufacturers Association pec CERTIFICATION LTD British Plumbing Employers Council Construction Products Association Builders Merchants Federation The Copper Development Association The UK Copper Board Institute of Plumbing Heating and Ventilating Contractors Association Thermostatic Mixing Valve Manufacturers Association Scottish and Northern Ireland Plumbing Employers Federation

In-line thermostatic Introduction 1 Choosing the best possible solution for the job is critical where the issue concerned is as important as helping to prevent scalding. Offering full compliance with all Regulations and Best Practice, the comprehensive Prestex range of in-line Thermostatic Mixing Valves (TMVs) combines high quality manufacture and top-of-the range performance with remarkable ease of installation and servicing. Prestex in-line TMVs are the ideal choice for eliminating the risk of scalding in healthcare, public and educational buildings, commercial and domestic projects. They are WRAS approved as suitable for sinks, wash basins, baths, bidets, single point showers, hair wash sprays and domestic hot water systems. Independently tested and approved to BuildCert TMV2 and TMV3 schemes gives added security when specifying. All of our TMVs are supplied with the following features as standard: Simplicity of installation and servicing Sensibly priced to offer best value BuildCert TMV2 and TMV3 scheme third party approvals TMV3 models fully compliant with NHS Model Engineering Specification DO8 Choice of standard, easy to service union connections or 90 angle valve combination Factory pre-set but easy to adjust to suit site conditions Complete with internal strainers and non-return valves Laser-etched bar code on body (below) provides unique record of product traceability Inlets and outlets protected by plastic caps (above) to prevent contamination of the element and the valve lubricant Screw-fixed, tamper-proof cap (above) to prevent unauthorised adjustment of the valve temperature setting Each carton is security sealed to avoid stock contamination and provide better audit control Chrome finish for easy cleaning NEW Combined TMV3/TMV2 valve option. 1 Range overview 2 Product details 3 Technical data 4 Other products 3

In-line thermostatic Product overview P402, P402UA In-line thermostatic Prestex in-line are designed to eliminate the risk of scalding and are suitable for use in a wide range of public, health care, social, commercial and domestic applications. Suitable for sinks, wash basins, bath, bidets, single point showers, hair wash sprays and domestic hot water systems Simple to install and service Temperature pre-set to 43ºC, but easily adjustable on site WRAS approved for a wide variety of uses Complies with NHS Model Engineering Specification DO8 Choice of standard, easy to service union connections or 90º angle valve combination 15mm and 22mm sizes. P404, P404UA In-line thermostatic Prestex in-line are designed to eliminate the risk of scalding and are suitable for use in a wide range of public, health care, social, commercial and domestic applications. Suitable for sinks, wash basins, bath, bidets, single point showers, hair wash sprays and domestic hot water systems Simple to install and service Temperature pre-set to 43ºC, but easily adjustable on site WRAS approved for a wide variety of uses Choice of standard, easy to service union connections or 90º angle valve combination 15mm and 22mm sizes. P405, P405UA In-line thermostatic Prestex in-line are designed to eliminate the risk of scalding and are suitable for use in a wide range of public, health care, social, commercial and domestic applications. Suitable for sinks, wash basins, bath, bidets, single point showers, hair wash sprays and domestic hot water systems Simple to install and service Temperature pre-set to 43ºC, but easily adjustable on site WRAS approved for a wide variety of uses Choice of standard, easy to service union connections or 90º angle valve combination Single valve option to meet TMV3 and TMV2 requirements 15mm and 22mm sizes. 4 1 Range overview 2 Product details 3 Technical data 4 Other products

In-line thermostatic Standards and approvals 1 It s Pegler Yorkshire s policy to provide a range of products and services which meet, or exceed, the requirements of our customers in respect of quality, cost and delivery. Approvals These products have been certified by WRAS and are audited periodically. TMVA TMVA is a representative trade body for UK companies within European standards activities. It plays a key part in promoting the safety of hot water systems. As part of the TMVA membership we offer a comprehensive range of thermo-static products approved under the BuildCert scheme. BuildCert Scheme Independent third party testing and approval scheme. BuildCert TMV3 Scheme certifies Type 3 Thermostatic Mixing Valves manufactured to meet the highest specification required by the NHS Estates DO8 standard for Mixing Valves within healthcare premises in the United Kingdom Complies with BS7942. BuildCert TMV2 Scheme certifies Type 2 Thermostatic Mixing Valves for the domestic market. For use in hot water systems in domestic premises Complies with EN 1111 : 1999 and EN 1287 : 1999. Part G Section G3 of the building Regulations 2000 amended April 2010 now makes the fitting of these valves mandatory in New Build properties for bath fill applications. 1 Range overview 2 Product details 3 Technical data 4 Other products 5

In-line thermostatic In line are designed to eliminate the risk of scalding and are suitable for use in a wide range of applications. B A P402/P402UA P402 In-line thermostatic * All ends compression. Copper x copper Size Finish A B Order code 15mm Chrome plate 102 137 5A1101 22mm Chrome plate 103 156 5A1102 Flow chart: Fig. 2, page 11 B A P402UA In-line thermostatic * All ends compression. Copper x copper. With angle valves Size Finish A B Order code 15mm Chrome plate 102 212 5A1103 22mm Chrome plate 103 240 5A1104 Flow chart: Fig. 2, page 11 P404/P404UA B A P404 In-line thermostatic * All ends compression. Copper x copper Size Finish A B Order code 15mm Chrome plate 102 137 5A1105 22mm Chrome plate 103 156 5A1106 Flow chart: Fig. 1, page 11 B A P404UA In-line thermostatic * All ends compression. Copper x copper. With angle valves Size Finish A B Order code 15mm Chrome plate 102 212 5A1107 22mm Chrome plate 103 240 5A1108 Flow chart: Fig. 1, page 11 6 1 Range overview 2 Product details 3 Technical data 4 Other products

2 P405/P405UA P405 In-line thermostatic * All ends compression. Copper x copper Size Finish A B Order code 15mm Chrome plate 102 137 5A1140 22mm Chrome plate 103 156 5A1141 Flow chart: Figs. 1 and 2, page 11 B A P405UA In-line thermostatic * All ends compression. Copper x copper. With angle valves Size Finish A B Order code 15mm Chrome plate 102 212 5A1142 22mm Chrome plate 103 240 5A1143 Flow chart: Figs. 1 and 2, page 11 B A 1 Range overview 2 Product details 3 Technical data 4 Other products 7

In-line thermostatic Technical data Prestex P402 and P405 TMV3 range: General specification P402/P405 P402UA/P405UA Materials DZR Brass DZR Brass Surface finish Chrome plated Chrome plated Water connections Compression all ends Compression all ends 15mm & 22mm Wafer strainers 90 angle valves with: Single non-return Single non-return valves valves on inlets Mesh strainer Test point plugs Isolating valves Technical specification General operating TMV3 approved P402 & P402UA, P405 & P405UA parameters parameters Minimum mixed temperature 30 C 38 C Maximum mixed temperature 50 C 46 C Maximum temperature deviation +/- 2 C +/- 2 C Maximum hot inlet temperature 85 C 65 C Maximum hot/cold cold/hot inlet pressure ratio 5 to 1 N/A Maximum static pressure 12 bar 10 bar Minimum dynamic flow pressure 0.1 bar 0.2 bar Minimum hot inlet to mixed outlet temperature differential 10 C 10 C Flow with 0.2 bar differential pressure loss 9.0L/M 9.0L/M Flow 1.0 bar differential pressure loss 18L/M 18L/M Approvals THE PRESTEX P402/P402UA & P405/P405UA HAVE BEEN APPROVED BY WRAS FOR THE FOLLOWING USES: Code Operating Range Size Application Max temp HP-B High pressure 15mm, 22mm Bidet 38 C HP-S High pressure 15mm, 22mm Shower 41 C HP-W High Pressure 15mm, 22mm Washbasin 41 C HP-T44 High pressure 22mm Bath 44 C HP-T46 High pressure 22mm Bath 46 C (assisted) LP-B Low pressure 15mm, 22mm Bidet 38 C LP-S Low pressure 15mm, 22mm Shower 41 C LP-W Low pressure 15mm, 22mm Washbasin 41 C Installation conditions UNDER THE TERMS OF THE BUILDCERT TMV3 SCHEME THE VALVE MUST BE INSTALLED UNDER THE FOLLOWING CONDITIONS: Operating Pressure Range Low Pressure High Pressure Maximum static pressure (bar) 10 10 Flow pressure, hot and cold (bar) 0.2 1 1 5 Hot supply temperature (ºC) 52 65 52 65 Cold supply temperature (ºC) 5 20 5 20 8 1 Range overview 2 Product details 3 Technical data 4 Other products

3 Prestex P404 and P405 TMV2 range: General specification P404/P405 P404UA/P405UA Materials DZR Brass DZR Brass Surface finish Chrome plated Chrome plated Water connections Compression all ends Compression all ends 15mm & 22mm Wafer strainers 90 angle valves with: Single non-return Single non-return valves valves on inlets Mesh strainer Test point plugs Isolating valves Technical specification P404 & P404UA, P405* & P405UA* BS EN 1287 : 1999 BS EN 1111 : 1999 Maximum static pressure (bar) 10.0 10.0 Supply pressure hot and cold (bar) 0.1 1.0 1.0 5.0 Hot supply (ºC) 55 65 55 65 Cold supply (ºC) Maximum 25 Maximum 25 Mixed water temperature ( C) Maximum 46 Maximum 46 Approvals P404 & P404UA BS EN 1287 : 1999 BS EN 1111 : 1999 15mm and 22mm Low pressure High pressure 0.1 1 bar 1 5 bar Bidet Shower Washbasin Tub Bath fill (ISO46 Cold Isolation Test at 46ºC) Approvals P405 & P405UA BS EN 1287 : 1999 BS EN 1111 : 1999 Low pressure 0.1 1 bar High pressure 1 5 bar 15mm 22mm 15mm 22mm Bidet Shower Washbasin Tub Bath fill (ISO46 Cold Isolation Test at 46ºC) Installation conditions P404 & P404UA/P405 & P405UA* CONDITIONS OF NORMAL USE: Operating pressure range Low pressure High pressure Maximum static pressure (bar) 10 10 Flow pressure, hot and cold (bar) 0.1 to 1 1 to 5 Hot supply temperature (ºC) 55 to 65 55 to 65 Cold supply temperature (ºC) <_ 25 <_ 25 The temperature differential for MIXING VALVE must be 10ºC *When used as a TMV2 valve add white cap after commissioning for identification. These products are certified under the BuildCert TMV3 and TMV2 schemes and have been independently tested by an approved testing laboratory WRc-NSF and is a Water Regulations Advisory Scheme (WRAS) approved product and listed in the Water Fittings and Materials Directory. 1 Range overview 2 Product details 3 Technical data 4 Other products 9

In-line thermostatic Technical data Pressures Pressure at the valve inlets must be within the 5:1 ratio under flow conditions. The size and layout of pipework and in-line fittings must take this into consideration. Optimum performance is achieved with equal pressure. Minimum Working Pressure Maximum Working Pressure Maximum Static Pressure Minimum Flow Rate 0,1 bar 5 bar 10 bar 5 L/min See Table 1 for conditions of normal use. Water Regulations MIXING VALVES must be installed in accordance with local Water Authority Water Regulations (Water Supply (Water Fittings) Regulations 1999). Your attention is therefore drawn to any installation requirements which may be applicable. This product is fitted with a WRAS approved listed single check valve cartridge for both the hot and cold supplies to the valve. If supplying a submerged outlet additional protection will be required. Isolating valves Isolation valves must be installed on the hot and cold connectors. Strainers Strainers must be installed on the hot and cold inlet connections as provided. Adjustment and commissioning The thermostatic controller is supplied factory pre-set at 43ºC. However, installation conditions will dictate that the product be adjusted on site. To adjust the temperature supply remove the plastic cap on top of the valve and adjust with a close fitting spanner. To increase the temperature turn anti-clockwise To decrease the temperature turn clockwise To set the valve to a maximum recommended mixed water temperature, see table below. APPLICATION MIXED WATER TEMPERATURE ºC Shower 41ºC Washbasin 41ºC Bidet 38ºC Bath 44ºC The temperatures and pressures must be stabilised and checked before commissioning (allow mixed water to flow for 1 minute prior final setting). All parameters must be in accordance with TABLE 1 above. Note: After adjustment replace the cap to prevent tampering. This valve must not be used to mix water above a temperature of 46 C. Hot water can burn and it is strongly recommended that both comfort and safety levels are considered when selecting a set temperature. Installation Prestex in-line thermostatic are fitted with internal strainers but where debris is a particular problem we recommend the fitting of serviceable external strainers. They can be fitted in any orientation provided the hot and cold supplies are connected as marked on the valve body (C = cold supply blue, H = hot supply red). The Prestex TMV range is supplied with compression connections for copper tube. Thermostatic are temperature sensitive devices and must not be subjected to extreme temperatures, either hot or cold, in use or installation. Cold Supply Mixed Water Outlet Hot Supply Note: We would recommend the fitting of full bore servicing valves on the inlet supplies to aid any future isolation requirements. To ensure proper performance of the, they should always be fully open during operation. Isolation valves should be installed as close as practicable to the mixing valve inlets. The UA versions are supplied complete with both strainers and full bore isolating valves. 10 1 Range overview 2 Product details 3 Technical data 4 Other products

3 In-service testing The purpose of in-service tests is to regularly monitor and record the performance of the thermostatic mixing valve. Deterioration in performance can indicate the need for service work on the valve and/or the water supplies. The normal service frequency is one year for TMV2 valves but site conditions may mean that the service checks should be undertaken more frequently. It is recommended that the service procedure in the NHS Document DO8 is followed for all TMV3 approved valves. Maximum continuous temperatures during testing should not exceed the following values: Bidet 40 C Shower 43 C Washbasin 43 C Bath 44 C Bath 46 C (for assisted bathing) If it is found to be impossible to obtain the correct setting point a service is required. Prestex in-line thermostatic mixing valves should not normally require part replacement. However a full range of spares is available on request and is detailed in the fitting instructions included with each product. Fig. 1: P404 & P404UA TMV2 In-line Flow Rate (L/min) 60 50 40 30 20 10 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Pressure (Bar) 15mm TMV 2 22mm TMV 2 Fig. 2: P402 & P402UA TMV3, P405 & P405UA TMV3/2 In-line 45 Maintenance Since the installed supply conditions are likely to be different from those applied in the laboratory tests, it is appropriate, at commissioning, to carry out some simple checks and tests on each mixing valve to provide a performance reference point for future in-service tests. For further information on service tests and maintenance refer to the installation instructions. Flow Rate (L/min) 40 35 30 25 20 15 10 5 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Pressure (Bar) 15mm TMV 3 22mm TMV 3 1 Range overview 2 Product details 3 Technical data 4 Other products 11

In-line thermostatic Technical data Product selection criteria ENVIRONMENT APPLIANCE IS A TMV: VALVE TYPE? REFERENCE REQUIRED BY RECOMMENDED SUGGESTED DOCUMENTS LEGISLATION OR BY LEGISLATION BEST AUTHORITATIVE OR AUTHORITATIVE PRACTICE? GUIDANCE? GUIDANCE? Private dwelling Bath yes TMV2* Building Regulations Basin yes TMV2 2010 Edition, Section G3 Shower yes TMV2 Housing association Bath yes TMV2 Housing Corp Standard dwelling Basin yes TMV2 (1.2.1.33a) Shower yes TMV2 Housing association Bath yes TMV2 Housing Corp Standard dwelling for the elderly Basin yes TMV2 (1.2.1.58 and Shower yes TMV2 (1.2.1.59) Hotel Bath yes TMV2 Guidance to the Basin yes TMV2 Water Regulations Shower yes TMV2 (G18.5) NHS nursing home Bath yes TMV3 NHS Health Guidance Note, Basin yes TMV3 Care Standards Act 2000, Shower yes TMV3 Care Homes Regulation 2001, TMV3 DO8 Private nursing home Bath yes TMV3 Guidance to the Water Basin yes TMV3 Regulations (G18.6), Shower yes TMV3 Care Standards Act 2000, Care Homes Regulations 2001, HSE Care Homes Guidance Young persons Bath yes TMV3 DoH National Minimum care home Basin yes TMV3 Standards Children s homes Shower yes TMV3 Regulations, Care Standards Act 2000, Care Homes Regulations 2001, HSE Care Homes Guidance Schools, Bath yes TMV2 Building Bulletin 87, including nursery Shower yes TMV2 2nd edition, The School Bath yes, but 43ºC max TMV2 Premises Regulations/ National Minimum Care Standards section 25.8 Schools for the Bath yes TMV3 Building Bulletin 87 2nd severely disabled Shower yes TMV3 edition, The Schools Premises including nursery Bath yes, but 43ºC max TMV3 Regulations, if residential, Care Standards Act NHS hospital Bath yes TMV3 NHS Health Guidance Note, Basin yes TMV3 DO8 Shower yes TMV3 Private hospital Bath yes TMV3 Guidance to the Basin yes TMV3 Water Regulations (G18.6) Shower yes TMV3 *TMV2: This BuildCert Scheme is not referenced in the amended Building Regulations. This independent third party approval scheme ensures that products must meet the BS EN 1111 and BS EN 1287 standards that are quoted in the amended Building Regulations. 12 1 Range overview 2 Product details 3 Technical data 4 Other products

3 Housing Corp Standard Housing Corporation, Scheme Development Standards, 5th Edition, Housing Corporation 2003. DO8 Model engineering specifications DO8 Thermostatic (healthcare premises), NHS Estates, 1997. Building Bulletin 87 2nd edition School Building and Design Unit Department for Education and Skills. Building Bulletin 87 2nd edition, Guidelines for environmental design in schools. DfES 2003, London. Guidance to the Water Regulations Department for Environment, Food & Rural Affairs, Water Supply (Water Supply (Water Fittings) Regulations 1999 Guidance Document relating to Schedule 1: Fluid Categories and Schedule 2: Requirements for Water Fittings. DEFRA 1999, London. DoH National Minimum Standards Children s homes Regulations Department of Health, National Minimum Standards Children s homes Regulations. National minimum care Standards Section 25.8 NHS Health Guidance Note National Health Service Guidance note, Safe hot water and surface temperatures. HSE Care Homes Guidance Health and Safety Executive, Health and Safety in care homes, HSG 220, HSE 2001. Care Standards Act 2000 Care Homes Regulations 2001 Children s Home Regulations 2001 The Building Regulations 2000 Sanitation, hot water safety and water efficiency. Approved Document G 2010 Edition, Section G3. 1 Range overview 2 Product details 3 Technical data 4 Other products 13

Performa Technical Tap/Shower Solutions Other products Optiflush Urinal Flush Controllers Reduces water usage by as much as 80% Battery or mains operated Suitable from 0.05 bar to 12 bar Flushes automatically every 12 hours Easy installation. Prestex PB300 Full Bore Quarter Turn Ball Valves 15mm 28mm sizes All sizes rated PN16 Blow out and vandal-proof assembly P.T.F.E. (Teflon) ball seals Viton O ring seals Prestex compression ends to EN 1254/2 Red T handle as standard with optional blue T handle for cold water applications. Prestex PT5 PRV Pressure Reducing Valve 15mm Tectite push-fit ends DZR body Drop tight seal Compact easy set design 0-25 bar inlet pressure range Single gauge connection points Complete with gauge. 14 1 Range overview 2 Product details 3 Technical data 4 Other products

4 Leger L555 Thermostatic Bath/ Shower Mixer Easy to operate Factory-set maximum working temperature 46 C Fast shut off for maximum safety Chrome plated to ISO 9227 Full range of shower kits available WRAS approved BuildCert TMV2 scheme approved. Waterfall 4S4501 Single Mode Low Pressure Shower Kit Single mode head High flow. Waterfall 4S4534 5 Mode Curved Shower Kit 3 mode head Pull down cord for head. IDEAL FOR DISABLED USE Performa 894/894 ISO Exposed Sequential Shower Factory-set maximum working temperature 43 C Maximum operating pressure 5 bar 15mm compression fittings with swivel inlets Chrome plated Full range of shower kits available BuildCert TMV3 scheme approved Easy to operate 894 ISO with built in isolation valves. 1 Range overview 2 Product details 3 Technical data 4 Other products 15

Pegler Yorkshire connect & control Our brands: UK sales Free Phone: 0800 156 0010 Free Fax: 0808 156 1011 Email: uk.sales@pegleryorkshire.co.uk Export Tel: +44 (0) 1302 855 656 Fax: +44 (0) 1302 730 513 Email: export@pegleryorkshire.co.uk Technical Help Free Phone: 0800 156 0050 Free Fax: 0808 156 1012 Email: tech.help@pegleryorkshire.co.uk ENERGY EFFICIENT SOLUTIONS Brochure Hotline Free Phone: 0800 156 0020 Free Fax: 0808 156 1011 Email: info@pegleryorkshire.co.uk www.pegleryorkshire.co.uk BATHROOM & KITCHEN SOLUTIONS Follow us on: Registered in England Company No. 00401507 Registered Office: Haigh Park Road, Stourton, Leeds, West Yorkshire, LS10 1RT, England. All brand names and logo styles are registered trademarks. Maintaining a policy of continual product development, Pegler Yorkshire reserves the right to change specifications, design and materials of products listed in this publication without prior notice. Pegler Yorkshire Group Limited St. Catherine s Avenue, Doncaster, South Yorkshire, DN4 8DF, England. Tel: 0844 243 4400 Fax: 0844 243 9870 LIT.REF: 880134.06.12