DF1151-Ex Infrared flame detector

Similar documents
DF1101-Ex Infrared flame detector

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

DC1192 Input /Output module

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Fire & Security Products. Siemens Flame Detector a highlight in detection. technology.

FDCL221-M Multi line separator module

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multisensor fire detector

FDCIO223 (ES 45) Transponder

FDOOT241-A9-Ex Multisensor fire detector

OOH740, OOHC740 Automatic fire detectors

DT1101A / DT1102A / DO110xA Automatic fire detectors

DOW1171 / DCW1151 Radio fire detection system

Input module, input/output modules

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

ASA linear smoke detector

FDCL221-Ex Line adapter (Ex)

FDOOT221, FDO221, FDT221

OH720, OP720, HI720, HI722

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

DM1131 / DM1133 / DM1134 Manual call points

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Multi line separator module

FDBZ290 Air sampling smoke detection kit

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDBZ290 Air sampling smoke detection kit

Output module (230 V)

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

Input module, input/output module

Test units and accessories

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

FC724 Fire control panel

Test units and accessories

Fire & Security Products. Siemens Building Technologies Group

OH110, OP110, HI110 Automatic fire detectors

FC722 Fire control panel

Radio fire detection system

Synova TM product catalog.

Test units and accessories

FDL241-9 Linear smoke detector Mounting Commissioning

FC722 Fire control panel

FC724 Fire control panel

Fire control panels FC726 FC726-XA

Mimic display driver, LED ribbon cable

FC2020 Fire control panel

FC723 Fire control panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

SWING radio fire detection system

Dräger Flame 2500 Flame Detection

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Fire control panels FC360

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Flame Detection Jon Sarfas

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Fire Detection systems. UniVario industrial fire detectors for every job

Dräger Flame 2100 Flame Detection

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

FDM273 Radio manual call point Mounting

Lamp Supply (Recommended)

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Frost Protection Thermostat

Dräger Flame 2500 (IR3) Flame Detection

IR15 Dual Gas Series Datasheet

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

FDCW241 Radio gateway Mounting

IR25 Dual Gas Series Datasheet

XC10 Extinguishing control panels

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Open Path Gas Detector

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

SIMRAD GD10 IR GAS DETECTOR

SIMRAD GD10PE IR GAS DETECTOR

talentum Flame detection across the spectrum Range Brochure

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

FDA241, FDA221 Siemens ASD

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

COMPACT FLAME CONTROLLER CFC 1000

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

Room thermostat with 24-hour time switch and large LCD

FP120-Z1 Power supply kit A (70 W) Technical Manual

UniVario Industrial Fire Detectors Versatile in Application

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Dräger Flame 2350 (UV&IR) Flame Detection

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Transcription:

DF1151-Ex Infrared flame detector Interactive, for explosion-hazard areas of zones 1 and 2 AlgoRex For inside and outside applications Triple-sensor evaluation Detection in various wavelengths Microprocessor-controlled signal evaluation Selective evaluation of flicker frequency Selectable application algorithms Excellent immunity to false alarms thanks to a combination of patented fuzzy logic and Wavelet analysis Highest resistance to electromagnetic influence sunlight and heat radiation humidity and corrosion Wide operating temperature range Connectable to interactive fire detection systems Control Products and Systems

Characteristics Environmental ecologically processing recyclable materials electronic and synthetic material simple separable Characteristics the detector housing made of aluminum also serves as a screen against electromagnetic interference (EMB) the base housing consists of a robust, glass-fiber reinforced synthetic material protected electronics built-in alarm indicator (AI) interactive signal processing Explosion protection category The infrared flame detector DF1151-Ex is designed to the explosion protection category 'Intrinsic safety' EEx i. The standards which cover this are EN50014 (IEC60079-0) und EN50020 (IEC60079-11) Function Patented signal evaluation Signal + Wavelet Time Fuzzy-Wavelet Fuzzy-Logik 3 Sensors The detection elements of the infrared flame detector consist of two pyroelectric sensors and a silicon photo diode. Sensor A: The pyroelectric sensor A reacts to infrared flame gas in the characteristic Infrared CO2 spectral range between 4.0 4.8 µm. radiation Sensor B: The pyroelectric B measures the infrared radiation of sources of interference in the range between 5.1 6 µm Sensor C: The silicon photo diode measures the solar radiation in the range between 0.7 1.1 µm One sensor measures the hot carbon dioxide in a specific flame wavelength; the two other sensors simultaneously measure the interference radiation in other wavelengths. With intelligent signal processing through fuzzy algorithms and wavelet analysis, the DF1151-Ex achieves excellent detection reliability while maintaining the highest immunity to interference radiation and sunlight. In order to safeguard against a possible decision emergency, the detector contains an additional emergency activation channel. Application Chemicals production plants, chemicals stores Oil refineries petrol storage and pump stations Natural gas transfer points Propane and butane filling installations All explosion-hazard areas in which flaming fires involving carbonaceous materials are to be expected 2

Installation in explosion-hazard areas Equipment installed in explosion-hazard areas must always comply with local national regulations. The SB3 shunt Zener diode barrier is used as an interface between explosion-hazard and non-hazardous areas. Non-hazardous area Shunt Zener diode barrier SB3 Explosion hazard-area, of zones 1 and 2 Flame detector DF1151-Ex Line module E3M171 Equipotent bonding ground Alarm indicator DJ11xx-Ex, AJUT24-Ex Further details can be found in the document 'Fire protection in explosion-hazard areas', no. 1204 Accessories Mounting bracket MV1 Ball and socket joint MWV1 Rain hood DFZ1190 Test lamp StabexHF 120 120 150 130 120 136 164 118 165 Is used to make a performance check on the flame detector. It must be held in front of the detector (see document 252). 95 Design easy installation of the housing on stable, vibration-free surfaces; the detector is only inserted after installation check, shortly before commissioning 6 threads M20 for screwed cable glands connection via two-wire installation with the control unit ext. alarm indicator connectable pluggable connection between flame detector and base mounting bracket MV1 for room surveillance to fix the detector at the right inclination angle ball and socket joint MWV1 for the orientation to an object rain hood DFZ1190 for outside applications 3

Dimensions 77 45 135 Detector 135 Detector base M20 Technical data Alarm indicator (AI) ext. connectable 2 and programmable Operating temperature -35 +70 C Storage temperature -40 +75 C Humidity 95 % rel. (no heavy condensation of window) Connection factor IMK 3 Connection terminals 0.2 2.5 mm 2 Color white, ~RAL 9010 Protection category EN 60529 / IEC 60529 IP67 Standards for flame detector for explosion-hazard area Ex classification EN 54-10, EN 54-17 EN 50014 (IEC 60079-0), EN 50020 (IEC 60079-11) II 2 G EEx ib IIC T4 (-35 C Ta 70 C) Approvals VdS Nr. G200003, PTB 02 ATEX 2159, LPCB 126bc/01 Compatibility Compatible with interactive fire detection system S11 Operation with stub lines only Max. 32 detectors with IMK1 per E3M171 4

Details for ordering Type Part no Designation Weight DF1151-Ex BPZ:5357820001 Infrared flame detector 0.500 kg FDB1190 BPZ:5165360001 Base 0.250 kg A5Q00004478 Screwed cable gland M20 x 1.5 0.039 kg MV1 BPZ:3950450001 Mounting bracket 0.285 kg MWV1 BPZ:3674840001 Ball and socket joint 0.860 kg DFZ1190 BPZ:5302660001 Rain hood 0.640 kg Stabex HF BPZ:4620910001 Test lamp 0.250 kg 5

Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document no. 001877_l_en_-- Manual S11 Edition 2016-04-20 Section 6