SAX. Window & Wall Fans

Similar documents
POWERPLUS SPP Product Brochure

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

HIT Centrifugal In-Line Fan

GORILLA HVLS Installation & Maintenance

LOWERING THE COST OF HIGH CEILINGS

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

MINIFLOW SMF Installation & Maintenance

POWERPLUS SPP Installation & Maintenance

RAPTOR SPA Installation & Maintenance

Domestic & Commercial Fans

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

GIVE A FAN A CHANCE Installation Dos & Don ts

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Installation manual Mori HR

Ventilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers

Simply Silent Contour 4 (100mm) Axial Extraction Fan

TWINFLOW STDR Installation & Maintenance

RAPID RESPONSE. Quiet Operation. Powerful Performance. Header Box Exhaust Fan

RAPTOR COOLER SRC Installation & Maintenance

KADO LUX LED EXHAUST FAN 200

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

General Fan Selection

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

Silhouette Installation and Wiring Instructions

Centrifugal extract and condensation control fans

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

SPECIFICATION FOR APPROVAL. Customer Description Part No.. Model No. JDD VBBA51(0A24) Sample Issue No. Sample Issue Date

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

Mini fans MiniVent M1/100

BATHROOM EXTRACT FANS SILENT-100 Series

Car Park Ventilation 1

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

ECO dmev Decentralised MEV

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

MRXBOXAB-ECO3 MRXBOX-ECO3

SMOKE CONTROL - NEW DIRECTIONS

MRXBOXAB-ECO2 MRXBOX-ECO2

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

Caution: The fans must not be used in bath or shower enclosures.

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year.

G Installation manual Solitude - dmev unit

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

Wall fans. High air performance and low energy consumption

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

SPECIFICATION FOR APPROVAL

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

(P) AD0612VB-A7BGP P.S. REV. DC FAN (RoHS)

SLIMAIRE 230V & 12V SINGLE SPEED FANS

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Xpelair Simply Silent TM DX100 Fan

Lo-Carbon Quadra Centrifugal Fan

(57.7) X. March 2006 PRODUCTS. ... the complete solution

KADO LUX 3-IN-1 HEAT LIGHT EXHAUST

Our quietest bathroom fan. Fact.

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Ventilation and Hand Dryers

Centrif Duo & Centrif Duo Plus

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Xpelair Simply Silent TM Contour Fan

Installation and Wiring Instructions

Cooling Fans ver ver.4

Xpelair Simply Silent DX100

Xpelair Simply Silent DX150

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

研發處 研發處 研發處 研發處 簡文榮 林茂盛 AD0612LB-A73GL P.S. REV. DC FAN (RoHS) 研發處

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Axial fans The right fan for every house

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

GUIDELINES FOR A CORRECT VENTILATION

Wind. Service instruction

EH0533 Indoor Climate Control

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon Quadra SELV

D100, D125 & D150. Installation Instructions

World-class small room fans. Premium design with highest energy efficiency.

MDA Series. DC Axial Flow Fans with Low-Speed Alarm. $$ The Low-Speed Alarm: "Features

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

ENERGY RECOVERY VENTILATION (ERV)

Whole Room Dryer WRD, WRD/110

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION.

INSTALLATION GUIDE ISODRIVE MOTOR. ST - 900m 3 /hr.

Industrial Ventilation

Revised Record 研發處發行章 Rev. Revision Description Change page Date A00 Preliminary

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Lo-Carbon T-series Window & Roof Models

Transcription:

SAX Window & Wall Fans

features & benefits The SAX is a stylish, high performance range of axial flow fans which provides powerful extract of air through windows, walls, ceilings and panels for a variety of domestic and commercial applications. Axial impeller design for larger volumes. Two standard sizes, 9 and 12 Automatic and reversible models. Air volume flow rates of up to 0.528 m³/s (1900 m³/hr). Static pressures of up to 80 Pa. IPX4 Splash proof. Shock proof, heat resistant plastic. Suitable for operating temperatures of up to 40 C. Motors are double insulated with built in thermal overload protection. Sealed for life ball bearings to operate at any angle. Energy efficient with low power absorption. Features & Benefits Versatility The SAX is designed for installation into windows, panels, ceilings, as well as most solid or cavity walls. Range - There are two standard sizes, 9 and 12 as well as automatic reversible models which allow shutters to be left open where natural ventilation is required without any security risk. Options - SAX automatic models incorporate silent, delayed action, slow moving electric shutters for silent opening and closing, and depending on model, a 5 speed controller, which may be fully reversible. Safety SAX fans are IPX4 Splash proof, protected against water splashed from all directions which means they can be safely installed in Zones I and II in accordance with IEE Wiring Regulations. Motor protection Each SAX motor is double insulated so no earth is required, and fitted with integral thermal overload protection which prevents the motor from overheating. Ease of installation Designed and supplied with all the necessary fixings, which means easy fix mounting by one installer alone for the complete installation of the fan. Material strength - Units are manufactured from shock proof, heat resistant white plastic with a temperature stability of 107 C, robust, durable and non corrosive, with internal and external finger proof grilles. Cost effective The high performance rates of the SAX unit mean they are cost effective as installations no longer require two or more fans. Inclusive All built-in units are supplied with telescopic wall liner, internal wall grille, external shutter and five speed reversible controller which minimises costs. Flexibility Available in 2 sizes with a 5 speed reversible controller to give the installer a range of adjustment if duties are under or over achieving. Mounting Each unit is suitable for window, wall, panel or ceiling mounting installations. Full ancillary range Wall kits, window kits, fan locking rings. Reliability Motors have sealed for life bearings. Warranty Each SAX has a 2 year warranty. Applications Pubs, restaurants, offices, kitchens, factories, schools and shops.

product information Product Code SAX23/9A SAX23/9AR SAX23/9ARB SAX30/12A SAX30/12AR SAX30/12ARB Description Basic unit, fan only Basic Unit c/w speed controller Pull cord operated unit Basic unit, fan only Run on timer unit Pull cord operated unit Product Code Voltage Maximum Volume Mounting Arrangement Operation l/sec m³/hr Ceiling Wall Window Fan Only Electrically Reversible Speed Control Speed Control Option Standard SAX23/9A 230 229 824 SAX23/9AR 230 229 824 SAX23/9ARB 230 229 824 SAX30/12A 230 528 1900 SAX30/12AR 230 528 1900 SAX30/12ARB 230 528 1900

dimensional data A C B Window Mount D E F Wall Mount Product A B C D E F Weight Code kg SAX23/9A 340 200 40 - - - 5 SAX23/9AR 340 200 40 - - - 6 SAX23/9ARB - - - 415 40 240-315 11 SAX30/12A 420 230 40 - - - 8 SAX30/12AR 420 230 40 - - - 9 SAX30/12ARB - - - 495 40 240-315 15

performance data 80 SAX23/9A/AR/ARB SAX30/12A/AR/ARB 70 60 50 Pressure - Pa 40 30 20 10 0 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 Volume - m 3 /s

performance & electrical data Product Fan Max Max Max FLC Power dba Code Size Airflow Pa Speed Amps Watts @ m 3 /s r/min 3m SAX23/9A 9 0.229 75 1350 0.20 45 49 SAX23/9AR* 9 0.229 75 1350 0.20 45 49 SAX23/9ARB* 9 0.229 75 1350 0.20 45 49 SAX30/12A 12 0.528 80 1200 0.39 90 51 SAX30/12AR* 12 0.528 80 1200 0.39 90 51 SAX30/12ARB* 12 0.528 80 1200 0.39 90 51 Units that are suffixed with an A include a silent operated shutter. These are either intake only, extract only or both (in conjunction with a double pole switch). * Units that are suffixed with an AR and ARB include silent operated shutters. These units are five speed extract and supply, operated through a control provided with the unit. Units suffixed with ARB include a telescopic steel wall liner. Sound levels are average spherical free field values for comparative purposes only.

Elta Fans Ltd - Applied Technology Elta Fans Ltd - Building Services 17 Barnes Wallis Road, 46 Third Avenue, Segensworth East Industrial Estate, Pensnett Trading Estate, Kingswinford, Fareham, Hampshire, P015 5ST, United Kingdom. West Midlands, DY6 7US, United Kingdom. Visit: eltafans.com e-mail: mailbox@eltafans.co.uk Applied Technology: Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555 Building Services: Tel: +44 (0) 1384 275800 Fax: +44 (0) 1384 275810 Export: Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555