Dehumidification at Part Load

Similar documents
Implications of GHP Fan Control Strategies on Humidity Control in Commercial Applications

Air Conditioning for and-humid Climates:

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

product application data PERFECT HUMIDITY DEHUMIDIFICATION SYSTEM

Relative Humidity in Schools Jim Cummings and Chuck Withers

Optimisation of cooling coil performance during operation stage for improved humidity control

Active desiccant integration with packaged rooftop HVAC equipment

MODELING OF THE SINGLE COIL, TWIN FAN AIR-CONDITIONING SYSTEM IN ENERGYPLUS

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

Adding More Fan Power Can Be a Good Thing

Case Study of an Innovative HVAC System with Integral Dehumidifier. Florida Solar Energy Center Cocoa, Florida

Energy Impacts of Various Residential Mechanical Ventilation Strategies

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

Dehumidification System Enhancements

TESTS OF ADSIL COATING

97.501B. Prepared by: (415) Sponsored By: Final Report. Author: Presented at: ASHRAE. Meeting SF Me!

Optimizing Energy Efficiency and Improved Dehumidification Performance of Variable Capacity Air Conditioning Systems

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

INSTALLATION INSTRUCTIONS

Closing the Gap: Getting Full Performance from Residential Central Air Conditioners. Task 4 - Develop New Climate-Sensitive Air Conditioner

Don t Turn Active Beams Into Expensive Diffusers

Performance Rating of Computer and Data Processing Room Air Conditioners

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

Executive Summary: Evaluation of the Impact of Vacant Home Space Conditioning Strategies on Summer Relative Humidity, Energy, and Peak Load; Phase II

Best Practices for Condensing Boilers

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

An Hourly Building Simulation Tool to Evaluate Hybrid Desiccant System Configuration Options

New Approach to Energy Savings For Rooftop AC

SPLIT-SYSTEM RESIDENTIAL HEAT PUMP WITH SEPARATE DEHUMIDIFICATION OPERATING MODE

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

PACKAGE AIR CONDITIONER

Do All DOAS Configurations Provide the Same Benefits?

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Dehumidification: Energy Efficiency Comparisons

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Designing Energy Efficient Outdoor Air Systems

Energy Recovery Ventilation

ACHIEVING ENERGY-EFFICIENT DATA CENTER COOLING: DOES REDUCING FAN SPEED ALWAYS RESULT IN ENERGY SAVINGS?

EFFECT OF RETURN AIR LEAKAGE ON AIR CONDITIONER PERFORMANCE IN HOTAUMTD CLIMATES

Interim Report for the Period thru February 15, 2018 Submitted to Department of Business and Professional Regulations Office of Codes and Standards

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Technical Papers. 37th Annual Meeting. International Institute of Ammonia Refrigeration. March 22 25, 2015

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Air Conditioning Clinic

Field Test of Combined Desiccant-Evaporator Cycle Providing Lower Dew Points and Enhanced Dehumidification

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

High-Performance VAV Systems

Performance Rating of Unit Ventilators

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Applying VRF? Don t Overlook Standard 15

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Psychrometric Engineering Applications

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

EFFECT OF REFRIGERANT CHARGE, DUCT LEAKAGE, AND. EVAPORATOR Am FLOW ON THE HIGH TEMPERATURE PERFORMANCE OF AIR CONDITIONERS AND HEAT PUMPS.

MANUAL J/S Summary One summary sheet for each system

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

Comfort and health-indoor air quality

Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment

A/C Cooling Load calculation and measurement

99.503A. Prepared by: (415) Drains: Power. Prepared for: ACEE. Final Report Contributors: Danny Parkerr. Me!

By MIKE WEST, PHD, PE Advantek Consulting Inc. Melbourne, Fla.

THE ULTIMATE ROOFTOP SOLUTION

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Applying VRF? Don t Overlook Standard 15

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Summary Comparison of Simulation Program Features

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996

ENGINEERING. Edition No. 13 October 2002

Prepared by: (415) With. High. Prepared for: Final Report June 27, Contributors: Tom. Me!

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Application of Air Source Variable Refrigerant Flow in Cold Climates

Trane CDQ Desiccant Dehumidification

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Final Report. Investigation of Energy Impacts of Ducted Dehumidifier Duct Configurations and Location. DBPR Project #B21551 UCF/FSEC #

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Introduction. Motor Types

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Selection of air conditioning systems

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Low GWP Refrigerants for Air Conditioning Applications

Transcription:

Dehumidification at Part Load Authors Shirey III, Don Henderson Jr., Hugh Original Publication Don Shirey III, Hugh Henderson Jr., Dehumidification at Part Load, ASHRAE Journal, April 2004. This article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. Publication Number FSEC-GP-151-06 Copyright Copyright Florida Solar Energy Center/University of Central Florida 1679 Clearlake Road, Cocoa, Florida 32922, USA (321) 638-1000 All rights reserved. Disclaimer The Florida Solar Energy Center/University of Central Florida nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the Florida Solar Energy Center/University of Central Florida or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the Florida Solar Energy Center/University of Central Florida or any agency thereof.

The following article was published in ASHRAE Journal, April 2004. Copyright 2004 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. It is presented for educational purposes only. This article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. By Don B. Shirey III, Member ASHRAE, and Hugh I. Henderson Jr., P.E., Member ASHRAE E ngineers and equipment manufacturers need a better understanding of dehumidification performance at part-load conditions to evaluate the impacts of their design choices on indoor humidity levels, occupant comfort, and indoor air quality. Data from previous field test studies 1,2 show that the moisture removal capacity of a cooling coil degrades at part-load conditions especially when the supply air fan operates continuously. Figure 1 illustrates this concept with transient data from a laboratory test. Degradation occurs because a portion of the moisture that condenses on the coil surfaces during the cooling on cycle (blue data) evaporates back into the airstream when the coil is off (green data). The data in the plot shows that the transient off-cycle performance of the coil is essentially adiabatic with sensible cooling (red data) provided in conjunction with evaporation of moisture (green data) back into the airstream. The off-cycle sensible cooling diminishes with time as the amount of available moisture on the coil surfaces decreases. As a result, a cooling coil that cycles on and off in response to a control or thermostat signal will provide a smaller fraction of its total cooling capacity as moisture removal when the system spends relatively more time with the coil off. Conversely, the full latent removal capability of the system is only realized when the coil operates continuously. The net impact of this latent degradation phenomenon is that dehumidification performance depends on the runtime fraction of the cooling coil (load divided by steady-state capacity). Fig- About the Authors Don B. Shirey III is principal research engineer at the Florida Solar Energy Center in Cocoa, Fla. Hugh I. Henderson Jr., P.E., is a principal with CDH Energy in Cazenovia, N.Y. 42 ASHRAE Journal ashrae.org April 2004

ure 2 shows the field-measured impact of part-load operation on the sensible heat ratio (SHR) of a residential water-to-air heat pump with continuous supply air fan operation. 2 When the cooling system operates at steady-state conditions (i.e., at a runtime fraction of one), the effective SHR of the system is 0.76. However, as the compressor runs less often, the effective SHR of the cooling coil increases, meaning that less moisture removal is provided. In this case, the cooling system provided no latent removal for compressor runtime fractions less than 40%. Most cooling coils spend a large number of hours at part-load conditions. As a result, there is considerable degradation in the moisture removal capacity for a system across the cooling season. This part-load degradation causes space humidity levels to drift upwards, especially on days when cooling loads are modest. A Model to Predict Latent Degradation Henderson and Rengarajan 3 developed a mathematical model to predict the degradation of latent (dehumidification) capacity of single-stage cooling equipment at part-load conditions. This model, shown as a line on Figure 2, demonstrates agreement with these measured data. The model parameters and γ were derived from on-site measurements for this system to be 720 seconds (12 minutes) and 1.07 respectively. 2 Figure 3 shows the meaning of the model parameters and γ. An amount of moisture (M o ) must build up on the coil before condensate falls from the coil. After this time (t o ), all the latent capacity provided by the coil is useful moisture removal since this condensate leaves the system through the drain. When the coil cycles off and the supply air fan continues to operate, the initial mass of moisture buildup on the coil (M o ) evaporates back into the airstream. If the cooling coil cycles back on before all the moisture has evaporated, then the time until the first condensate removal is reduced for this next cooling cycle since the coil starts out partially wetted. The parameter is the ratio of the coil s moisture holding capacity (M o ) and steady-state latent capacity (Q L ). is the nominal time for moisture to fall from the coil (starting from a dry coil and ignoring transient effects at startup). The other parameter γ is defined as the ratio of the initial evaporation rate (Q e ) and the steady-state latent capacity (Q L ). The latent degradation model requires two additional parameters that also are associated with engineering models for part-load efficiency. 3 These additional parameters include τ, the time constant associated with latent capacity at startup (for the system in Figure 2 it was assumed to be 75 seconds). The other parameter N max is the maximum cycling rate of the thermostat as defined in the NEMA thermostat test standard. 4 A project was initiated in 2001 to collect additional laboratory and field measurements of part-load cooling coil performance. These data are used to verify the existing latent degradation mathematical model and to refine or extend the model to predict latent degradation for a wider range of cooling systems (e.g., multistage cooling equipment and constant air volume chilled water systems). April 2004 ASHRAE Journal 43

Capacity, Thousand Btu/h 30 20 10 0 10 Latent Removal Sensible Off-Cycle Evaporation Is Adiabatic Process: Sensible Latent Compressor Latent Addition 20 0 20 40 60 80 100 Minutes Figure 1: Transient sensible & latent capacity of cooling coil over an operating cycle (supply air fan operates continuously). Initial Test Results For this project, a psychrometric testing facility was set up for evaluating air conditioner cooling coils with cooling capacities up to 3 tons (10.5 kw). The facility includes indoor and outdoor test chambers capable of maintaining constant temperature and humidity conditions as specified in ANSI/ ASHRAE Standard 37, Methods of Testing for Rating Unitary Air-Conditioning and Heat Pump Equipment. 5 The facility is able to hold the desired conditions, even for transient testing, where the cooling equipment is cycled on and off. Laboratory testing has been completed for several coils. Each coil is tested at various entering air temperature/humidity conditions, airflow rates, and coil refrigerant temperatures. Overall, the test results from the laboratory tend to confirm the following trends: The off-cycle evaporation process becomes adiabatic after refrigerant migration inside the coil and system has subsided one or two minutes after the compressor stops operating. The type of refrigerant expansion device has some impact on the length of this transition. The mass of moisture retained on the coil surface is mostly a function of coil surface geometry with some secondary dependence on dew-point temperature and velocity of entering air. The calculated values of the model parameter are generally in line with the measured condensate delay time (t o ). The delay time is a strong function of the entering air conditions. As entering conditions are more humid, moisture builds up faster on the coil, so the time to first condensate removal is shorter. For example, the delay time for Coil 2 varies from 40 to 10 minutes as the entering dew point goes from 50 F to 70 F (10 C to 21 C). The moisture evaporation rate during the off cycle is a function of the wet-bulb depression (i.e., the difference between the wet-bulb and dry-bulb temperatures) of the entering air, as would be expected for an evaporative cooler. The retained moisture on the cooling coil evaporates more quickly Sensible Heat Ratio 1.10 1.00 0.90 0.80 0.70 Continuous Supply Air Fan Operation Measured Data: Averaged into Four-Hour Intervals Entering RH: 57% to 63% Entering Air Temp.: 68 F to 72 F Loop Temps.: 65 F to 90 F Steady State SHR = 0.76 0.0 0.2 0.4 0.6 0.8 1.0 Runtime Fraction ( ) Figure 2: Field data showing the net impact of part-load operation on sensible heat ratio. 2 Latent Capacity M 0 Useful Moisture Removal Time (t 0 ) When Condensate First Falls From Drain Pan Q e Latent Degradation Model With: = 720 sec γ = 1.07 N max = 3.6 cyc/h τ = 75 sec Linear Decay 0 20 40 60 Minutes with drier inlet air conditions. The off-cycle evaporation trend implies that the wetted surface area of the coil decreases in proportion to the remaining moisture mass. So the wet coil acts as an evaporative cooler with progressively less surface area as moisture is evaporated from the coil. Table 1 compares the latent performance model parameters determined for the five coils that have been tested in the laboratory to date. The tested coils ranged in size from 1.5 to 3 tons (5.3 10.5 kw), with the total fin surface area varying by nearly a factor of two from the largest to the smallest coil. The moisture-holding capacity per total finned surface area has been very similar for most of the lab-tested coils at 8 to 9 lbs per 1,000 ft 2 (39 to 44 g/m 2 ) of fin area. Less accurate field measurements of moisture-holding capacity also have resulted in a similar range of values: typically 6 to 10 lb per 1,000 ft 2 (30 to 50 g/m 2 ). The one exception observed thus far is lab Coil 4. This vertical slab coil with wavy fins retained 50% to 60% more moisture per unit surface area than the other coils. Through continued lab testing, we intend to quantify how fin spacing, Q L Evaporation =M 0 /Q L γ =Q e /Q L M 0 Evaporation Figure 3: Concepts of moisture buildup and evaporation. 44 ASHRAE Journal ashrae.org April 2004

Sensible Heat Ratio ( ) 1.0 0.8 1st Cycle 2nd Cycle 3rd Cycle = 17.3, gamma = 1.50, exp. Steady State SHR = 0.755 (Based on Condensate) 0.0 0.2 0.4 0.6 0.8 1.0 Runtime Fraction ( ) Figure 4: Comparing measured latent degradation to LHR model at nominal conditions (Coil 2). fin type, and coil orientation affect the moisture-holding capacity of the coil. The time for condensate to first fall from the coil (t o ) varied from 12 minutes to 33 minutes for the lab test coils at nominal conditions. Similar variations were observed for the model parameter. The results from field testing have generally confirmed these parameter values for other cooling coils. As part of the test program, we have completed a series of quasi-steady cyclic tests in the laboratory with differing lengths of compressor on and off times to simulate real-world cycling performance. The lengths of the on and off times were selected to correspond with the NEMA thermostat curve with a maximum cycle rate of three cycles/hour. 4 The quasi-steady lab testing showed the same degradation trends observed in the Sensible Heat Ratio ( ) 1.0 0.8 1st Cycle 2nd Cycle 3rd Cycle Steady State SHR = 0.730 (Based on Condensate) 0.0 0.2 0.4 0.6 0.8 1.0 Runtime Fraction ( ) Figure 5: Measured latent degradation with cycling fan at nominal conditions. field (e.g., in Figure 2) and confirmed that the model by Henderson and Rengarajan 3 could reasonably predict partload dehumidification performance. The data points shown in Figure 4 for Coil 2 correspond to the first, second, and third operating cycles at the same inlet air conditions and discrete runtime fractions. Typically, the results for the second and third cycles for a given runtime fraction are in close agreement, implying that at least two cycles are necessary to achieve quasisteady conditions. The triangles from the third cycle match the latent degradation model, which is shown as a line on the plot. The parameters for the model include a of 17.3 minutes and gamma of 1.5 for Coil 2. Similar tests have been completed at other operating conditions that also show agreement between the model and the measured data. Cooling Fin Surface Moisture-Holding Cond. Capacity Area Capacity, M o Delay Time, t o lb/1,000 ft tons (kw) ft 2 (m 2 ) lb (kg) (g/m 2 ) Min Min Coil 1 (Slanted Slab, Three Rows, 13 fpi, Plain Fins, Orifice) Coil 2 Normal Air Flow Rate 3.0 (10.5) 243.8 (22.7) 2.1 (0.95) 8.6 (42.1) 13.5 16.5 (A-coil, Three Rows, 15.5 fpi, Lanced Sine-Wave Fins, TXV) Coil 3 Coil 2 with Low Airflow 2.4 (8.4) 237.8 (22.1) 2.0 (0.91) 8.4 (41.1) 16.3 17.0 (A-Coil, Three rows, 15.5 fpi, Lanced Sine-Wave Fins, TXV) Coil 4 1.5 (5.3) 237.8 (22.1) 2.0 (0.91) 8.4 (41.1) 32.5 29.0 (Vert. Slab, Two rows, 14 fpi, Wavy Fins, Orifice) Coil 5 1.8 (6.3) 138.3 (12.8) 1.9 (0.86) 13.7 (67.0) 23.5 18.5 (Slanted Slab, Four Rows, 12 fpi, Wavy Fins, Orifice) 2.3 (8.1) 162.7 (15.1) 1.4 (0.64) 8.6 (42.1) 11.5 9.0 Notes: 1. Cooling capacity includes sensible and latent cooling at nominal conditions with airflow rate of 400 cfm/ton (54 L/s per kw). Nominal conditions correspond to ASHRAE Test A test point. 2. Fin surface area is gross fin area (coil face area coil depth fin spacing 2). 3. Condensate delay time and are at nominal conditions. Table 1: Comparing measured performance parameters for lab-tested cooling coils. April 2004 ASHRAE Journal 45

Laboratory testing also has been used to evaluate cooling coils with the AUTO fan mode, where the supply air fan cycles on and off with the compressor. Figure 5 shows that degradation in latent capacity is even apparent with this fan operating mode, although to much lesser extent than with continuous supply air fan operation. Most of the coils tested in the lab so far have shown some amount of degradation in the AUTO fan mode. Data collected from field test sites also have confirmed that degradation occurs with both continuous (ON) and cycling (AUTO) fan operation. Practical Implications on Equipment Design and Controls This research project also measured the performance of cooling coils at six different residential and commercial field test sites. The data from these test sites generally have confirmed the findings of laboratory testing. The field measurements also have demonstrated that control and equipment configuration issues have a significant impact on latent degradation and the ability to control space humidity levels. For instance, field measurements for a 10-ton (35 kw) packaged rooftop unit in a retail application showed that having two stages of cooling capacity significantly reduced the impact of latent degradation. The SHR of the cooling coil was maintained fairly well at part-load conditions since the system spent many hours with the first stage operating continuously. Therefore, humidity control was reasonably maintained in this commercial application even with continuous supply air fan operation. In contrast, a single-stage rooftop would have resulted in extremely poor space humidity control in this application since the compressor would have operated for several thousand hours at less than a 50% runtime fraction. The field results show that the expected negative impact of constant fan operation in commercial applications can be greatly mitigated by specifying multistage equipment. However, engineers and designers must be sure to specify rooftop equipment with coil circuiting that provides good dehumidification at part load (i.e., using face-split evaporator coils instead of rowsplit coils). Similarly, a two-stage residential cooling system with variable-speed air handler was monitored in a Florida home and was shown to experience little part-load latent degradation. Since the fan speed was modulated properly with the compressor cooling capacity, the SHR of the system was held low enough to provide adequate dehumidification when operating in first-stage cooling. The system operated continuously for hundreds of hours at low capacity, so good humidity control was maintained continuously. The high-efficiency, two-speed residential systems that now are available provide longer compressor on-times, which can result in better indoor humidity control if supply air fan speed is properly modulated with cooling capacity. The results from this research project also confirm and quantify the impact equipment oversizing has on humidity control. Whether operating with continuous fan operation, as is common in commercial applications, or in the AUTO fan mode, as most residential systems do, dehumidification performance degrades at part-load conditions. Oversizing AC equipment increases the time spent at part load and results in higher space humidity levels. Carefully sizing equipment to match the cooling load requirements results in better humidity control and higher system efficiency since part-load losses are minimized. Modulated chilled water coils in large commercial systems also experience latent degradation at part-load conditions. Field testing of a constant air volume chilled water coil in a Florida commercial building confirmed the expected drop in latent capacity as the water flow rate through the chilled water coil modulates to match the load requirements. In applications where improved humidity control is important, designers should consider controlling cooling capacity by bypassing air around the coil. The air bypass method clearly provides better humidity control at part load compared to systems that modulate capacity by varying the chilled water flow rate. Variable air volume systems also provide good dehumidification when controlled to an appropriate discharge air temperature. Better Simulation Tools The key to developing better building designs is to provide engineers and other building design professionals with better tools to understand the implications of their design decisions. Dynamic (e.g., hourly) building simulation tools provide the best means for engineers to evaluate how well their designs perform at part-load conditions. Unfortunately, most mainstream hourly building simulation tools currently do not predict space humidity levels properly at part load. Since these mainstream simulation models do not consider partload degradation, they tend to overesti- Advertisement in the print edition formerly in this space. 46 ASHRAE Journal ashrae.org April 2004

mate the moisture removal capacity of cooling equipment and predict that space humidity levels are maintained at lower levels than are observed in practice. Kosar et al. 6 showed that ignoring latent degradation causes hourly building simulation models to underpredict space humidity levels by 5% to 10% RH under typical conditions in a small office application. The latent degradation model from Henderson and Rengarajan has already been incorporated into some whole building hourly simulation models 7,8,9 and will be available soon in other models. 10 This research project has confirmed the validity of the latent degradation model for single-capacity systems and is working to refine the model to consider more applications. We are also working to understand the moisture-related characteristics of cooling coils so we can develop guidelines for selecting model parameters for an array of cooling coil and equipment configurations. Advertisement in the print edition formerly in this space. Summary The latent capacity of a cooling coil degrades at part-load conditions. This degradation is most significant when the supply air fan operates continuously with a single-stage cooling coil. However, some degradation also occurs with modulated and staged cooling systems as well. Continuous supply air fan operation is used in nearly all commercial buildings to provide the outdoor air ventilation requirements prescribed by ANSI/ASHRAE Standard 62, Ventilation for Acceptable Indoor Air Quality 11 and to provide air circulation for occupant comfort. The impact of latent degradation must be considered in these circumstances. A recent utility research project indicated that 2% of Florida homeowners operated the supply air fan continuously. 12 This fan operation mode may become more prevalent in residential applications if its use is recommended for central air filtration systems (e.g., UVC lamps or high-efficiency air filters), ventilation requirements, 13 or occupant comfort. However, most residential air conditioners cycle the supply air fan on and off with the cooling coil in response to the thermostat signal (AUTO fan control). Most homeowners in humid regions inherently know this operating mode is preferable since it provides reasonable moisture removal. However, laboratory data have confirmed that even AUTO fan control can result in significant degradation in dehumidification performance at part load. This study is working to quantify the equipment characteristics, control modes, and operating conditions where latent degradation is a concern. Algorithms to predict latent degradation are being incorporated into hourly whole building energy analysis tools to allow building designers and equipment manufacturers to quantify the impact as well. Acknowledgments This article was prepared with the support of the U.S. Department of Energy, under Award No. DE-FC26-01NT41253. However, any opinions, findings, conclusions, or recommendations expressed herein are those of the authors and do no necessarily reflect the views of the DOE. References 1. Khattar, M., N. Ramanan, and M. Swami. 1985. Fan cycling effects on air conditioner moisture removal performance in warm, humid climates. Presented at the International Symposium on Moisture and Humidity. April. Washington, D.C. 2. Henderson, H. 1998. The impact of partload air-conditioner operation on dehumidification performance: Validating a latent capacity degradation model. Presented at ASHRAE s IAQ & Energy 98 conference. 3. Henderson, H., and K. Rengarajan. 1996. A model to predict the latent capacity of air conditioners and heat pumps at part-load conditions with constant fan operation. ASHRAE Transactions 102(1): 266 274. 4. NEMA. 1990. Residential Controls Electric Wall-Mounted Room Thermostats, NEMA Standards Publication No. DC 3. National Electrical Manufacturers Association, Washington, D.C. 5. ANSI/ASHRAE Standard 37-1988, Methods of Testing for Rating Unitary Air-Conditioning and Heat Pump Equipment. 6. Kosar, D.R., M.J. Witte, D.B. Shirey, and R.L. Hedrick. 1998. Dehumidification issues of Standard 62-1989. ASHRAE Journal 40(3). 7. EPRI. 2000. Supermarket Simulation Tool Version 3: Installation and User Guide, Electric Power Research Institute, Customer Solutions Group, Palo Alto, Calif. CM- 111112-R4. 8. Shirey, D.B. and K. Rengarajan. Impacts of ASHRAE Standard 62-1989 on small Florida offices. ASHRAE Transactions 102(1):153 165. 9. EPA. 2001. Indoor Humidity Assessment Tool Reference Manual. Available at www.epa.gov/iaq/schooldesign/saves.html. 10. EnergyPlus. 2003. Engineering Reference Manual for Energy Plus. Available at www.energyplus.gov. 11. ANSI/ASHRAE Standard 62-2001, Ventilation for Acceptable Indoor Air Quality. 12. Personal correspondence with D. Parker regarding a large scale utility study: Parker, D.S., Research highlights from a large scale residential monitoring study in a hot climate. Proceedings of International Symposium on Highly Efficient Use of Energy and Reduction of its Environmental Impact, pp. 108 116, Japan Society for the Promotion of Science Research for the Future Program, JPS-RFTF97P01002, Osaka, Japan, January 2002. (Also published as FSEC-PF369-02, Florida Solar Energy Center, Cocoa, Fla.) 13. ASHRAE Standard 62.2-2003, Ventilation for Acceptable Indoor Air Quality in Low- Rise Residential Buildings. April 2004 ASHRAE Journal 47