DPM4 Bedside Monitor Default Settings Hospital: Department: Clinical / Sales / Service Representative: (** Patient Size Dependent) Date: Software Version: (* Optional) System Menu System Setup Menu Face Select Signature of Departmental Representative: Title: Standard, Trend Screen, oxycrg, View Screen, Large Font Screen Mintrends Screen Setup Parameter 1 Parameter 2 Parameter 3 Parameter 4 Parameter 5 Alarm Setup Menu Common Alarm Setup Vol 0-10 Reminder Vol. Time 8, 16, 32 sec. Paused Time 1-3 min Time Setup Individual Alarm Setup Year Month Refer to individual parameter setup and alarm default pages 2001-2099 1-12 Day 1-31 Hour 0-23 Minute 0-59 Seconds 0-59 Format yyyy-mm-dd, mm-dd-yyyy, dd-mm-yyyyy Record Setup Rec Wave 1 Rec Wave 2 Rec Wave 3 RT Rec Time Timing Rec Time Rec Rate Rec Grid, Resp, CO2*, Off, Resp, CO2*, Off, Resp, CO2*, Off 8 sec, Continual Off, 10, 20, 30, 40, 50 min; 1, 2, 3, 4 hrs 25, 50 Analog Module Setup Trace Setup Analog Out Analog Wave Parameters Analog Wave Parameters Wave Sequence 1 ECG, Resp, Temp, SpO2, NIBP, IBP*(1,2), CO2* ECG1, ECG2, Resp, Temp, SpO2, NIBP, IBP*(1,2), CO2* Wave Sequence 2 Wave Sequence 3 Wave Sequence 4 Wave Sequence 5 Page 1
System Menu (cont.) Key Volume Help 0-10 Scan Type Refresh, Scroll Alarm Limit Version Brightness Device Version List 1-10 Host Boot Module ECG Module NIBP Module IBP* Module CO2* Module Keypad Module Recorder Module SPO2 Module Standard Display ECG ECG 1 ECG 2* ECG 1 Gain ECG 2 Gain* Filter I, II, III, avr, avl, avf, V(n) I, II, III, avr, avl, avf, V(n) 0.125, 0.25, 0.5, 1, 2, Auto 0.125, 0.25, 0.5, 1, 2, Auto Diagnostic, Monitor, Surgery IBP* Resp Ch1 Ch2 Lead Art, PA, CVP, RAP, LAP, ICP, P1, P2 Art, PA, CVP, RAP, LAP, ICP, P1, P2 I, II Gain 0.25, 0.5, 1, 2, 3, 4, 5 Parameter Menus ECG Setup HR Hi 17-350** bpm Lo 15-348** bpm HR From ECG, SPO2, IBP*, Auto, All 12.5, 25, 50 mm/s Lead Display 3 Leads, 5 Leads ECG Display Normal, Multi-Leads Display, Half-Scn Multi-Leads Arrh Analysis* ** Arr Threshold* ** Arr Anal PVCs Arr Lev Hi Asys Delay Vtac Rate Vtac PVC Multif PVC Tachy HI Brady LO 1-10 3-10 sec 100-200 bpm 3-12 PVC 3-31 PVC 100-350* bpm 15-90* bpm Page 2
ECG Setup (cont.) Arr Alarm* ** Adult Alarm Level Rec Asystole ON Vfib ON Vtac ON R on T LOW MED VT>2 LOW MED Couplet LOW MED Multifocal PVC LOW MED Vent Rhythm LOW MED Bigeminy LOW MED Trigeminy LOW MED Tachy LOW MED Brady LOW MED Irreg. Rhythm LOW MED PNC LOW MED PNP LOW MED Arr Alarm* ** Missed Beat LOW MED Pediatric Alarm Level Rec Asystole ON Vfib ON Vtac ON R on T LOW MED VT>2 LOW MED Couplet LOW MED Multifocal PVC LOW MED Vent Rhythm LOW MED Bigeminy LOW MED Trigeminy LOW MED Tachy LOW MED Brady LOW MED Irreg. Rhythm LOW MED PNC LOW MED PNP LOW MED Missed Beat LOW MED ST Analysis* ** ST anal ST alm ST lev Hi Lo ECG Display 0 - +2.0 0 - -2.0 Normal, Multi-Leads Display, Half-Scn Multi-Leads Other Setup Smart Lead Off Beat Vol 0-10 Pace Pace Lead Pacer Rate 40-100 bpm Notch Cascade DeFib Sync Page 3
Parameter Menus Resp Setup Temp Setup SPO2 Setup NIBP Setup IBP 1/P1* Setup Hi** Lo** Apnea Hold Type T1 Hi T1 Lo T2 Hi T2 Lo TD Hi Temp Unit SPO2 Hi SPO2 Lo PR Hi** PR Lo** PR Sound Sensitivity (Mindray) Average Time (Masimo)* Sensitivity Mode (Masimo)* NIBP Simul: SYS Hi** SYS Lo** Mean Hi** Mean Lo** Dia Hi** Dia Lo** Display Unit Interval Amp PR Sound Filter Response IBP1 Unit IBP2 Unit 2-120 0-118 10, 15, 20, 25, 30, 35, 40 sec 6.25, 12.5, 25 mm/s Auto, Manual 1-50 (C), 33.8-122 (F) 0-49 (C), 32-120.2 (F) 1-50 (C), 33.8-122 (F) 0-49 (C), 32-120.2 (F) 0-50 (C), 0-90 (F) F, C 1-100% 0-99% 1-254 0-253 12.5, 25 mm/s 0-10 2-4, 4-6, 8, 10, 12, 14, 16 sec Normal, High 45-270 mmhg; 6.0-35.9 kpa 40-265 mmhg; 5.3-35.2 kpa 25-230 mmhg; 3.3-30.6 kpa 20-225 mmhg; 2.7-29.9 kpa 15-210 mmhg; 2.0-27.9 kpa 10-205 mmhg; 1.3-27.3 kpa 1 Group, Groups mmhg, kpa Manual, 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 min Auto, Manual 12.5, 25 mm/s 0-10 Normal, Smooth, No filter mmhg, kpa mmhg, kpa Page 4
Parameter Menus IBP 1/P1* Setup (cont.) Alarm Limit Setup CH1: Sys Hi** CH1: Sys Lo** CH1: Mean Hi** CH1: Mean Lo** CH1: Dia Hi** CH1: Dia Lo** CH2: Sys Hi** CH2: Sys Lo** CH2: Mean Hi** CH2: Mean Lo** CH2: Dia Hi** CH2: Dia Lo** PR Hi PR Lo 1-254 0-253 Expand Pressure P1 Select P2 Select Sys, Mean, Dia; Mean Sys, Mean, Dia; Mean CO2* Setup Alarm Limit Setup Other Setup CO2 Hi CO2 Lo Ins CO2 Hi AwRR Hi AwRR Lo Apnea Unit Wave Scale Flow Rate O2 Compen Des Compen N2O Compen BTPS Compen 2-99 mmhg; 0.3-13.2 %, kpa 0-97 mmhg; 1-12.9 %, kpa Off, 0-99 mmhg; 0-13 (% or kpa) 2-120 0-118 10, 15, 20, 25, 30, 35, 40 sec 6.25, 12.5, 25 mm/sec %, kpa, mmhg High, Low 70, 100 ml/min Page 5
Maintenance Menu User Maintenance Menu (Password Required) Monitor Name Department Bed Number Net Type Local Net Number Notch Freq Language Aux Output Lead Naming Poweron Conf Multiple s Multiple s 1-250 CMS, CMS+ Multiple s 50, 69 Hz English, Chinese, French, German, Italian, Polish, Spanish, Portuguese, Russia, Czech, Turkish, Danish, Dutch, Finnish, Hungarian, Norwegian, Swedish, Romanian, Serbian Analog Out, Nurse Call, Defib. Syn AHA, EURO Last Conf, User Adu Conf, User Ped Conf, User Neo Conf Alarm Setup Alarm Sound Off Audio Mode Para Type Reminder Tone Reminder Interval ECG Lead Off Level SPO2 Sensor Off Level Enable, Disable Mode1, Mode2 Latch, Unlatch 1, 2, 3 min High, Med, Low High, Med, Low IP Address Color Self-Define Nurse Call Setup Wirelss Net Setup ECG SPO2 IBP1 IBP2 Resp CO2 Other Para Signal Duration Signal Type el Type CO2 Other Para Pulse, Continuum Normal Open, Normal Close Tech., Phys. Factory Maintenance Menu (Password Required) Temp Sensor VGA Size Transfer Wave Mode VGA Switch Module Setup CY-F1, YSI 8.4, 10.4, 12.1, 15, 17' TFT Mono, Color ECG, Resp, Temp, SpO2, NIBP, IBP* (1,2), CO2*, Recorder Page 6