FREEZE CASE HISTORY. 3-½ Tailpipe 7" packer 5-¾ open hole Lateral = 1500 ft

Similar documents
Table of Contents. 55 Foot Mast Trailer Tab 1. A Stops Tab 2. Bailers Tab 3. Bailer Bottoms See Tab 3. Baker Plugs See Tab 24. Broaching Tools Tab 4

OVERVIEW SERVICES: Coiled Tubing Nitrogen Pressure Pumping Thru Tubing Tools

Mud Pump (Emsco Type) Diesel Engine

Deploying SET and ESeal Technology Using Coiled Tubing. Marcus Vondenstein

Better Oil Tools Africa General presentation

PowerReach Service: Hybrid Coiled Tubing & Jointed Pipe Technology. Fraser McNeil

Integrated Cased-Hole Services. Maximum Well Performance

DOWNHOLE VIDEO DIAGNOSTICS FISHING AND MILLING CHEMICALS AND DISPLACEMENTS WELLBORE CLEANOUT TOOLS DVD.WELL

RELAY. Digital Slickline System INTELLIGENT SLICKLINE CONVEYANCE FOR WELL INTERVENTION

Engineering Test Facilities Carrollton, Texas Halliburton. All Rights Reserved. IMPROVING COMPLETION RELIABILITY THROUGH TESTING

DynaBlade. Predictive Jet Cutters

Figure 6- Capillary Installation

Standard Operating Procedure

Weatherford Drilling with Casing

FISHING WITH THE AGITATOR SYSTEM

Cased Hole Division. Jimmy Mathis Cased Hole Manager Youngsville, LA. District

InTang DOWNHOLE EQUIPMENT RENTAL $ 3, HINTON 4800' 2 7/8" PH6 TUBING

Perforating and Pipe Recovery with Digital Slickline First Application in Colombia Ballena Field

Kinetics Controls & Innovation Ltd RIGLESS WELL INTEGRITY & INTERVENTION ISOLATIONS. kciltd.co.uk

TECHNICAL PUBLICATION

How to Solve Your Long Lateral Problems. A Deep Well Services White Paper in Conjunction with SPE Penn State

Installation & Operation Manual Models:

SLICK-E-LINE COMBINING MECHANICAL SLICKLINE CAPABILITY WITH REAL TIME LOGGING ONE CREW. ONE LINE. ONE RIG-UP.

DOUBLE AND SINGLE ENTRY DRUM SCREEN ADVANCED WATER SCREENING TECHNOLOGY

Development of a High Pressure Gas Gun for H 2 S and CO 2 Service

CORPORATE PROFILE. Contents 1 Introduction 2 Products and Services 3 Contact Us 10

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

TC-720 RECYCLING BALER

Guidelines for the Safe Operation of Tubing Conveyed Perforating Systems

Expandable Well Technology. David Butler

By Joe Lisenbee, Steve Fulwider and Jeff Knight, Centrilift

New and Unusual Applications for Plunger Lift System

Operator s Manual. Linear Asphalt Compactor. Jesse D. Doyle Isaac L. Howard, PhD Mississippi State University. January 2010 CMRC M 10-1 Version 1

Weatherford Completions Key-Techs Overview. Manuel Molina Technical Sales Manager

The Experts in Vacuum Solutions

BOP Management System Information

S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design.

Verde GSE PCA Bridge and Ground Mount Units 30/45/60/90/120 Tons. Installation and Maintenance Manual

1 SIX WAYS to Reduce Well Intervention Costs

Drilling-with-Casing (DwC ) Overcoming Wellbore Stability Issues

CS 2. Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual. Form No. 6120A

Petrosync Distinguished Instructor

Daikin Water Cooling, Heating, and High Capacity Booster Coils

Artificial Lift. Integrated lifting solutions for enhanced well production

TC-710 RECYCLING BALER

Casing Gas Separator: A New Gas Separation Technology

Modular Drawer Cabinets Installation Instructions

PRODUCTION WELL SERVICES. Diagnose, Restore, and Rejuvenate Rig-Free

HWD DRILLING RIG PRE-SPUD SAFETY INSPECTION-HWD 1000 RIGS

Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist

Boiler Mountings. Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh

BOP Ram Sensing and Interface Concept Rationale Intelligent BOP RAM Actuation Sensor System

Hydraulic Workover Unit (HWU) Application in Down-hole Milling Operations in Niger Delta

Table of Contents Categorized Listing

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

GS OILTOOLS PRESENTATION

Heaters and Defrosters

Petrosync Distinguished Instructor

4. Deflection Tools and Technique

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation th Terrace North Clearwater, Florida 33762

Owner s Guide and Installation Manual

COST EFFECTIVE PERMANENT VERIFIABLE PLUG AND ABANDONMENT. GLOBAL 24 HOURS

Heat Transfer. the new standard in. Heat Exchangers. Storage, Installation, Operation and Maintenance

Closing procedures for above-ground pools

What is Included with a Seasonal Service?

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

An Approach to Energy Efficiency: A Focus on an Increased Operational Efficiency, Natural Resource Conservation and Carbon Footprint Reduction

Owner s Guide and Installation Manual

Daylight Energy Ltd. Well Blowout W5M March 4, 2011

Technical Specifications & Pricing

20 TON AIR/MANUAL SHOP PRESS

Owner s Guide and Installation Manual

PURest Air Dryer Installation and Maintenance

STORAGE TANK INSTALLATION and OPERATION MANUAL

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

SERVICE BULLETIN A

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

Information Job Sheet 4. Closed-Loop Drainback Systems. Drainback tanks

AIRABLO 1050 rue acadie, Victoriaville, Québec, Canada G6T1R3 Phone Fax:

KINNEY OIL MIST ELIMINATORS

Owner s Guide and Installation Manual

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

Use of Electric Downhole Heaters to Prevent Wax Build-up, Offshore, West Africa by Alistair Hill and Rick Newell, Pentair Thermal Management

Integrated Well Abandonment

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Design of a CO 2 Injection System for Sequestration and Enhanced Oil and Gas Recovery Testing

Innovating WHILE DRILLING. Geosteering advances keeping wellbores in sweet spot CONTRACTOR MPD & UBO SAND CONTROL MARCH/APRIL 2011

Design Guide 2014 Fully Integrated Models 24" and 48"

High-Pressure Jet Kerf Drilling Shows Significant Potential To Increase ROP

DATE: 2/29/2012 DAILY WORKOVER / COMPLETION REPORT ISO. 3 loads of lime stone and leveled off. Re-spot 2-3/8" used tubing. VAC TRUCK FISHING TOOLS

Use this Construction/HVAC Glossary to answer the questions below.

Tomorrow s people, design and technology available today

Air Handler Unit. Installation & Operations Manual. Table of Contents. Bulletin No. H-IM-AH August 2002 Part Number 4346B001

ELGIN G4 GAS LEAK INCIDENT. 25 March 16 May 2012

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

DIVISION FINNED WATER-TUBE WATER HEATERS

AI-215 Series Portable Ice Maker

Transcription:

FREEZE CASE HISTORY The Problem The well was drilled with a statically underbalanced mud weight in MPD mode in HTHP conditions of 10,550 psi, 408 0 F, 32% CO 2, 200 ppm H 2 S to a depth of 14,800 ft md (11980 ft TVD). A 7 inch packer was snubbed in to isolate the HP reservoir while a chrome completion was run in the well with an upper 9-7/8 packer assembly. This operation was completed in part with the tubing hung off in the wellhead and the well bore but the packer was not set as it was planned to be done after tree installation. The well bore was per the figure below: Landing joint Rig BOP Wellbore Diagram Wellhead Tubing hanger 4-½ Tubing 9-5/8" packer 9-5/8" x 9-7/8" 11,500 ft md/tvd Pump out Plug 3-½ Tailpipe 7" packer 5-¾ open hole Lateral = 1500 ft Limestone 10,550 psi 408 F 100 ppm H2S 33% CO2 LWA Mar-11 7" liner shoe 13,300 md 11,970 TVD TD 14,800 md 12,070 TVD During the process of setting the upper packer the pump out plug in the lower packer exited its seat and upon pulling a wireline plug the well free flowed up the tubing to the rig floor. The wireline crew was unable to stop the flow, therefore the rig BOP was employed to shear the landing joint. The landing joint was sheared successfully, the flow stopped and the pressure on the rig BOP stabilized at 8500 psi. The wireline, running tools and the plug were left in the well. The well could not killed by bullheading because the plug was floating in the well and would set on its seat thus acting like a check where flow up was allowed but flow downwards was not possible. Lubrication of fluid was not a feasible option either (several attempts were made with no success) due do solubility of gas and oil based kill fluid. Several attempts were made to kill the well and all were unsuccessful. The situation was as per the diagram below: Freeze Case History South Sumatra 2010 Page 1 of 11

Blind/shear with booster 8500 psi Landing joint sheared off and crimped Full column of gas SIWHP 8500 psi 4500 feet of 0.092 inch slick line Wireline plug and running tools 10,550 PSI LWA 3-Mar-11 Thus the obstructions (fish) in the well were: a) Wireline plug and running tools b) Slick line (about 4500 feet) in chunks and bird nested c) Sheared and crimped landing joint d) Some solids from the open hole and OBM Freeze Case History South Sumatra 2010 Page 2 of 11

The Dilemma The problem after shearing the landing joint was that the well could not be re-entered, killed by pumping from the top (bullheading failed and volumetric failed) and wireline could not pass the crimped top of the sheared top of the landing joint. There was 8500 psi on the well and the BOP was past its testing period of 14 days. Well control experts from the name brand companies were consulted and they all recommended that the rig be skidded off and a snubbing unit be rigged up for fishing out the landing joint and wireline fish in the well. The owner of the well did NOT want to kill the well as the well was drilled MPD and killing the well would un-do the advantage of the MPD operation and severely damage the formation thus causing a heavy economic impact on gas deliverables. Fishing out wireline with snubbing techniques is very awkward under high pressure and could easily develop into a lengthy and costly operation that would result in damaging the well (scarring the inner bore of the special corrosion resistant materials. In an ordinary situation, Heavy Duty Wire Line would be employed to fish out the slick line and slick line tools and the plug. With the sheared off landing joint this was impossible until the landing joint was removed. The situation was summarized as follows: Well control experts said it is a snubbing job cannot be fixed otherwise Intuition says it s a HDWL job but the sheared landing joint prevents that work Pressure on the well prevented removal of the landing joint unless snubbing was employed (snubbing alone was estimated at $5m) The Solution ABEL Engineering with their knowledge of well control operations and in particular freezing operations developed a plan to freeze the wellhead and the tubing near the surface to isolate the wellhead pressure below the hanger. This would allow the BOP to be opened and the sheared off landing joint removed clearing the well from the hanger up. The plan was then to install a BPV in the hanger. Then to remove the BOP and install a tree. The freeze idea was proposed to: Boots n Coots Cudd Pressure Control Halliburton Energy Services The well control companies said that freezing would not work as the pressure were too high for any freeze to work and one would never effect a freeze to an inner string thru multiple string and the wellhead. Halliburton endorsed the freeze but could not mobilize an expert to site quickly due to visa issues and personnel availability. ABEL Engineering studied the problem and agreed with HES that the freeze could be done safely and effectively. Proving The Technique Several issues existed as the ice plug once in place potentially would the only barrier that would prevent a blowout where a capping job or relief well would be required. The two main issues were: could an inner string be frozen (thru multiple strings) and would the ice plug when in place hold 8500 psi. A mock up was constructed on site to prove and test the technique as per the diagram below: Freeze Case History South Sumatra 2010 Page 3 of 11

Open ended A A Ice plug 12" 4-½ 9-7/8" 13-3/8" 20" 30" Sec A-A plate Test pump 1'-6" 1'-6" dry ice methanol mix The inner strings were filled with water and the tubing filled with gel water mix (the freeze fluid to be forced into the tubing in the well). Dry ice and methanol mix was placed only 12 inch high in the tub so that the freeze plug would have limited height. After freeze was affected (tested by tagging from the top with a rod) the plug was pressure tested to 8500 psi for one hour. Then the pressure was increased until failure. The failure was observed at 10,100 psi. The Ice Plug was measured to be 14 inches in length. All tubulars used in the mock up test were identical (drops from the well construction) to the pressurized well. The results of the mock up proved that an inner string thru 4 (four) strings could be frozen, the ice plug would form in less than 8 hours and a 14 inch plug inside 4-1/2 tubing would hold 10,000 psi. It was surmised that longer plugs would hold higher pressure. Temperature Effects The metallurgy by the suppliers was confirmed that -78C would not harm the metal. However a caution was given that the impact (brittle) strength was affected and that impact loads (hammering, dropped objects, etc.) could cause a crack in the metal. Also that after the temperature was allowed to return to ambient or to well flowing conditions (elevated temperatures) that no effect on strength would occur by taking the temperature down to dry ice and methanol mix temperatures. Freeze Case History South Sumatra 2010 Page 4 of 11

The Freeze Job The freeze was accomplished by building a wooden frame around the wellhead. Then water was forced into the annuli of the outer strings (30x20; 13-3/8 x9-7/8 ; 9-7/8 x 4-1/2 ). The freeze material was a heavy gel / water pill and about 12 bbls were forced into the tubing via the kill line on the BOP. The pressure was taken to 10,000 psi to accomplish this. The gel pill caused the pill to stay in place while the wellhead head was cooled. Dry Ice from several locations around Indonesia was shipped via air freight to the nearest airport and then trucked to the site in Styrofoam containers. A container of about 8 bbls was used to mix the dry ice with methanol. This slush mixture was placed around the wellhead so that the top of the dry ice was mid-way on the C-section (tubing head). As the ice sublimated (evaporated) it was replaced every hour with a slush of dry ice and methanol. After some time the methanol evaporated leaving only packed dry ice. The temperature of dry ice at sea level is -108F. After 24 hours the pressure on the well was reduced in increments to zero. Dry Ice methanol mix (-78C or -108F) BOP C-section B-section Landing joint Ice plug 6'-2" 8'-2 7/16" Grade A-section 4-½ 9-7/8" 13-3/8" 20" 30" 8500 PSI LWA 10-MAR-11 Freeze Case History South Sumatra 2010 Page 5 of 11

The BOP Removal and Tree Installation The freeze was flow tested for 24 hours and observed to be zero. It then thought to be safe to open the BOP and see the condition of the landing joint. It was found to be crimped and flattened by the shearing process. A reverse screw driver fishing tool was then used to retrieve the landing joint by backing it out and grabbing it. Then this was done, a section of wireline was seen across the hanger profile which prevented the BPV from being installed. The next step was to lift off the BOP, clean out the hanger profile and cut the 0.092 wire and to install the BPV in the tubing hanger. This was accomplished in about 1 hour. A 10k tree was then installed. While this procedure does NOT meet the dual barrier rule per se it does prove that: 1. an Ice Plug when properly implemented can hold high pressures 2. there is sufficient heat transfer across multiple strings (> 15 inches) that allow water to be frozen 3. dry ice sublimation temperature (-108F) does NOT change the metal properties or cause brittle problems 4. dry ice and methanol can be handled safely and efficiently 5. the overall method is simple to implement and manage (avoids costly N2 apparatus now employed by other experts Conclusion Freezing a tube (in this case 4.5 inch chrome) to form an ice plug will effectively create an isolation plug that will hold in excess of 10,000 psi for as long as the plug remains frozen. It can be done quickly and efficiently using ordinary consumables found in drilling operations, namely water, gel, pumps and dry ice (from the local market). Photo Gallery BOP Removal and Tree Installation Below are photos taken during the freeze operation described above. Freeze Case History South Sumatra 2010 Page 6 of 11

BOP stack up with 8500 psi under the blind ram Methanol Dry Ice Mix Bucket Freeze Case History South Sumatra2010 Page 7 of 11

Reverse screw driver used to back off the landing joint Sheared off lower section of landing joint after recovery Freeze Case History South Sumatra2010 Page 8 of 11

Top of sheared off landing joint (crimped during shearing bent while fishing out) x Recording wellhead temperature with handheld device Freeze Case History South Sumatra2010 Page 9 of 11

Moment of Truth BOP is lifted off the wellhead with only ice holding pressure Top of C Section (tubing hanger) upon lifting off the BOP (Note the 0.092 wire and ice that formed 2 feet above top of dry ice application) Freeze Case History South Sumatra 2010 Page 10 of 11

Installation of the BPV in tubing hanger (second barrier installed) Installation of the tree (well fully secured!) Freeze Case History South Sumatra 2010 Page 11 of 11