safe and your operations compliant

Similar documents
Gas Detection. Honeywell BW Solo. The next generation in portable single gas detection.

Honeywell Analytics. Order List BW Clip & IntelliDoX

MicroRAE. Wireless, Portable Four-Gas Detector. Gas Detection

IntelliDoX Operator Manual

Gas Detection. Product Guide EMEA PORTABLE GAS DETECTION

Gas Detection. PORTABLE GAS DETECTION Product Guide

SERVING EASTERN CANADA FOR OVER 25 YEARS! Gas Detecion. MicroRAE

PROTÉGÉ ZM SINGLE GAS MONITOR

Bw Gas Alert Clip 2 H2s Extreme User Manual

Dräger Pac 8500 Single-Gas Detector

up to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment,

Multi-gas made simple

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

multi-gas detector Go the distance, and save Wear yellow. Work safe.

Dräger Pac 6000 Single-Gas Detector

SPM Flex Chemcassette Tape-Based Gas Detector

GasAlertMicroClip X3 Specifications

Introduction to Docking Technology

Dräger Pac 8500 Single-Gas Detection Device

IMR IX176 Portable Gas Detector User Manual

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Dräger Pac 6000 Single-Gas Detection Device

Order Sheet. Wear yellow. Work safe.

multi-gas detectors Multi-gas made easier Wear yellow. Work safe.

SPM Flex Chemcassette Tape-Based Gas Detector

Dräger Pac 8000 Single-Gas Detection Device

All users are recommended to update their existing ProRAE Guardian (PRG) software to v

Gas Detection. ConneXt Loneworker Real-time visibility on the safety, location and productivity of your isolated workers

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

IT S WHAT S INSIDE THAT COUNTS

IT S WHAT S INSIDE THAT COUNTS

T.ex Single Gas Detector VISA

ALTAIR 5X Multigas Detector

4-gas Detector with Pump

ALTAIR 5X Multigas Detector

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

IT S WHAT S INSIDE THAT

Safe Operation Manual. Honeywell IQ Force Gas Detector

MeshGuard and MeshGuard Gamma

Dräger Pac 3500 Single-Gas Detection Device

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

AreaRAE Pro Wireless, transportable area monitor Remote visibility on more threats than ever for an enhanced level of real-time situational

Dräger Pac 7000 Single-Gas Detection Device

ALTAIR 5X Multigas Detector Product Specification

Dräger Pac 5500 Single-Gas Detection Device

BW Clip4. Portable Gas Detector. Operator Manual

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

Single Gas Clip and SGC Plus User s Manual Rev 2.1 READ FIRST BEFORE OPERATION WARNING STATEMENTS / AVERTISSEMENT Activating tthe detector for the

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

altair 2X Gas Detectors

Dräger X-am 2500 Multi-Gas Detection

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

IT S WHAT S INSIDE THAT COUNTS

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

MGC Dock User s Manual

Dräger Configuration and Evaluation Software

ALTAIR 2X Gas Detectors It s what s inside that really counts

Single Gas Clip and SGC Plus User s Manual Rev 2.3

Dräger X-am 7000 Multi-Gas Detection

altair 2X Gas Detectors

MeshGuard and MeshGuard Gamma

Dräger Pac 3500 Single-Gas Detection Device

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detection

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

G-TECTA TM. Portable Gas Detection Instruments

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Dräger X-am 5000 Multi-Gas Detection

MGC Dock User s Manual

For the Safety of Your

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Neotronics Impact & Impact Pro

EC FX NH3. A new and improved approach to ammonia gas detection

Cold chain monitoring technologies. Facility monitoring

Dew-Point Transmitters and Instruments

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Security Alarm Systems

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

ST Safety to go. DRÄGER PORTABLE GAS DETECTION INSTRUMENTS

Dräger X-am 2500 Multi-Gas Detector

Recalibrate the way you look at gas detection

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation

Zareba Sensepoint Pro

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Technical Reference Guide. 1, 2, 3, and 4-Gas Detector

True Connectivity. True Convenience.

The New DUSTTRAK II and DRX Aerosol Monitors

Dräger Bump Test Station Calibration and Bump Testing

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

The New DUSTTRAK II and DRX Aerosol Monitors

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

BP MAINTENANCE WORK INSTRUCTIONS FREQUENTLY ASKED QUESTIONS

Transcription:

BW Clip Series The most reliable way to keep your workers safe and your operations compliant Easy gas identification with color coded labels and LCD indication: H2S CO O2 SO2

BW Clip Series best maintenance-free The detector series yet from the most trusted experts in gas detection When you turn on a gas detector from Honeywell Analytics, you re activating years of continuous protection. Every second of the day, our gas detectors are monitoring for the presence of potentially harmful or explosive gases that you can t see alerting you to danger so you can take the right action. And when it comes to protecting your workers and facilities, Honeywell Analytics pioneered the concept of the maintenance-free single-gas portable detector, giving you an easy, cost-effective, reliable way to ensure safety and compliance. With one of our portable gas detectors as your constant companion, gas hazards are one less thing to worry about. Because you can rely on Honeywell to protect your workers and your operations 24/7.

Now, with the BW Clip Series, your day-to-day companion is more reliable than ever. Easy gas identification with color coded labels and LCD indication: H 2 S CO The BW Clip Series of single-gas maintenance-free detectors are available in the following versions: BW Clip provides standard life remaining display, calibration not required. BW Clip Real Time includes a real-time gas level display and the ability to calibrate the device. Both are available in the following variants: O 2 SO 2 Two-year: H 2 S, CO, O 2 and SO 2 Three-year: H 2 S and CO Up to three years maintenance-free. Just turn on the detector and it runs continuously no need for sensor and battery replacement or battery charging. That means great reliability and no downtime. The most user-friendly experience. With one-button operation, the BW Clip Series is compact, lightweight and easy to handle, while tough enough for harsh environments and extreme temperatures. And if there s an alarm, you ll know it even in noisy conditions thanks to the wide-angle flash, along with the audible and vibrating alerts. BW Clip Real Time provides realtime readings of atmospheric gas concentration levels, giving users instant visibility of the gas readings and ppm levels, even when not in alarm conditions. Compatibility with current docking stations. For automated bump testing and fleet management, the BW Clip Series is compatible with the MicroDock II docking station and Fleet Manager II software. Automated self-test for improved safety. With the BW Clip Series, there s no need to perform a manual self-test to check the detector s battery, sensor and electronics. Instead, a daily self-test happens automatically. If it finds an issue in critical functionality, it will shut down the detector to protect you from unsafe use.

BW Clip Series Get even more value from the BW Clip Series with the IntelliDoX instrument management system IntelliDoX combines smart docking modules with our Fleet Manager II software to provide automated testing and record-keeping for all BW Clip detectors. Simply place the detector in the docking module, and it automatically tests the gas detector and sensors. Then use either USB or Ethernet to transfer bump tests, gas exposure events and more to your computer, where you can use the Change alarm set points and more with a new level software to analyze the data, track compliance and configure the detectors. Driving safety and among workers of customization for maintenance-free detectors compliance Use IntelliDoX to activate the BW Clip Series non-compliance indicator. It flashes red when a bump test is due or a gas event occurs. This way, workers can help each other improve safety by easily spotting non-compliant detectors.

With IntelliDoX, the BW Clip Series are the most flexible and configurable detectors available. The system delivers: The quickest bump test in the industry. Bump five detectors in less than a minute or 50 in fewer than three minutes with no wasted calibration gas. That means no more bottlenecks from workers lining up to bump their detectors. Flexible configuration to adapt to changing requirements. Just because the BW Clip Series are maintenancefree devices doesn t mean you cannot customize them to meet changing safety policies or regulations. Want to adjust the high and low alarm set points? Email a bump-test reminder to workers? Set detectors to show the gas reading during alarm? Do all this and more to improve safety and productivity. Efficient networking and data transfer for easy record-keeping. Are workers bump testing at the right frequency? If a detector had a gas exposure, would you know about it? Can you produce the compliance reports you need during a regulatory audit? Use IntelliDoX to easily transfer the 35 most recent gas events and bump tests for each detector to your computer. Quick and easy setup great for turnarounds. IntelliDoX is easy to install, taking under two minutes to set up a five-module system and bump your first detector with no tools required. To connect a module to the computers on your network, all you need is an Ethernet cable and an IP address. You can also set up without a network: just use a USB drive to load the settings for your detectors.

BW Clip Series Flexible instrument testing for maximum productivity Unique design for unmatched speed and flexibility The IntelliDoX system is expandable to five docking modules helping you drive productivity, reliability and efficiency. Provides a new level of customization for bump testing, configuration and record-keeping in a maintenance-free detector Configure alarm set points and change settings throughout the operation life of the detector Quick and easy setup great for turnarounds Each module has its own easy-to-read LCD screen and keypad for independent operation Thanks to this design, you can perform different activities for multiple detectors all at the same time. Want to bump test detectors? Calibrate detectors? Reconfigure settings on another group of detectors? Put others into hibernation? You can do all of these tasks concurrently, so you get more done in less time. Hibernation: get the most life for the price When you use the two-year versions for H 2 S or CO, you can hibernate the detector when you re not using it for a week or more and extend its life by that period of time, for up to a year. Perform different activities for multiple detectors all at the same time To hibernate the detector, just put it into hibernation mode and slip it into the hibernation case. No computer or complex procedure required. Holding a supply of detectors for a plant turnaround? Facing a few months between projects? Have workers going on leave? Hibernate each detector to preserve its life, and you can spread your detector s 24 months of operation over up to three years instead of the standard two.

BW Clip Series Locally available from USA 1.888.749.8878 Canada 1.800.663.4164 Europe +800 333 222 44 Middle East +971.4.450.5852 S.E Asia +65-91169653 China: +86.400.815.3366 Taiwan: +886.3.516.9284 Australia +61.3.9464.2770 Latin America +55.11.3309.1030 Other Countries +1.403.248.9226 20150128-03-EN www.gasmonitors.com www.honeywellanalytics.com