End-Use Data Collection Requirements Data Trend Type

Similar documents
Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

Challenges and Methods of Estimating a Conceptual HVAC Design

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

Appendix A. Glossary of Common Terms

Green Energy Waste Heat Recovery Solutions

Proposed Mechanical, Plumbing, and Electrical Systems For the LEDYARD POLICE DEPARTMENT LEDYARD, CT

Adsorption Chillers Energysmart Green Cooling

Geothermal Heating and Cooling Using Ground Source Heat Pumps. Prepared by: Steven Forrester, P.E. Principal

Energy Management and Controls

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

SECTION : CAMPUS CENTRAL METERING SYSTEM DESIGN

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK

ener$ave October EnerSave Proprietary

Energy & Water Savings in Commercial Food Service

Versa- Hydro. up to 96% Efficient

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Demand Side Management (DSM) Natural Gas

Daikin Blueprint: Delivering Hot Water with a Chiller

The (Hot) Water Efficient Commercial Kitchen. Charles M. Bohlig East Bay Municipal Utility District

Architectural Engineering Senior Thesis Mechanical System Redesign

New Features. IES Virtual Environment 6.4

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

Summary Comparison of Simulation Program Features

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS

9/18/2017. Nicholas Thornton, CEM. Systems: HVAC, Electrical, and Technology. Overview. Today s Goals Introductions HVAC Electrical Technology Q&A

Ve r s a - Hyd ro. 96% Efficient. The cost effec t i ve. ersa-hydro

Air-Conditioning Buying Guide

Continuous Commissioning: A Valuable Partner to Retrofit Projects

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

New York State Division of Housing and Community Renewal


Preparing the Next Generation of Building Technicians

August 15, 2013 Page 1 of 19

HVAC System Consideration$ 05/14/2012 SAVING MONEY IN HVAC SYSTEMS

Dehumidification: Energy Efficiency Comparisons

Cost of a Thanksgiving Meal

Method to test HVAC equipment at part load conditions

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

COOLING SYSTEM ECONOMICS. How much is my water treatment really costing? Is Bon Aqua treatment the right choice?

AHRI Certification Program Scopes - COOLING

Basic Equations and Conversion Factors

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

Hot water storage systems

Residential Water Conservation Research Brief On-Demand Hot Water Systems

CONTROLLED CHILLED BEAM PUMP MODULE

An Approach to Energy Efficiency: A Focus on an Increased Operational Efficiency, Natural Resource Conservation and Carbon Footprint Reduction

Basic Equations and Conversion Factors

Meter* (Existing or New) Comments 13,800 volt at plant or piggy back All Campus Utility Service Val Imm Electric Generator Building Existing

What you need to know about residential furnaces, air conditioners and heat pumps if you re NOT an HVAC professional

Get Wise to ThermWise. An Insider s Guide to ThermWise Rebates

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

ENERGY EFFICIENCY IN HOSPITALS- A CASE STUDY

General HVAC Recommendations

A/C Cooling Load calculation and measurement

Farm Energy Audit Workshop

THERMAL ICE STORAGE: Application & Design Guide

Contact Information. Steven Potratz, P.E. WSU Facilities Services, Engineering Services Manager Phone

Stage 1 Drought Restrictions Lifted

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

Figure 4 - Typical Mixing Valve Installation. LP-83 Rev

The goal of green heating is to use the least amount of fuel to heat a conditioned space.

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

IT WON T JUST MEET YOUR HOT WATER NEEDS.

05/14/2012 BOILER TUNE UPS & REPLACEMENTS PRESENTATION BOILER BASICS FOR LARGE INDUSTRIAL FACILITIES. Mark Bergum, P.E.

New PHE applications in construction & HVAC.

CONTROLLED CHILLED BEAM PUMP MODULE

Instantaneous Water Heaters

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

FOOD SERVICE EQUIPMENT REBATES

INSERT NEW PHOTO HERE

CENTRAL STATE HOSPITAL PLAN PLANT OPERATIONS UTILITIES MANAGEMENT PLAN

Energy Management Wiring Guide

ELECTRIC WATER HEATERS

METAL FINISHING WATER CONSERVATION. Presented by Mark Gentili

Plant Application Guide

Temperature. In the HVAC area, we talk about two kinds of temperatures.

The Ed Roberts Campus Berkeley, CA

SIOUX HYBRID WATER HEATER

COMMERCIAL CONDENSING BOILER OPTIMIZATION

Technical Assignment 3

Energy consumption storage facilities examined in ICE-E

EVLA Memorandum 107 Failure Pathology of EVLA WIDAR Correlator Support Systems October 18 th, 2006 Bob Broilo, Brent Carlson

Redesign of Bennett Hall HVAC System

(a) Upper section of M2P4-60

ELECTRICAL Seminar. B A L A Consulting Engineers, Inc. Edward J. Lynch, PE Vice President, Electrical Department Manager.

Wal-Mart HE.5 Supercenter

Business Energy Efficiency Incentives 2007

EVI + INVERTER MODELS A Q U A P U R A

Element Z General Design Requirements Existing Facilities Information

The M & V Guided Recommissioning Process. Energy & Water Conservation Program. September 2015 MOO

Total Hot Water Solutions

Energy Efficient Corn Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

Geothermal Heating, Cooling, and Hot Water Systems

WASTE REDUCTION AND RECYCLING PLAN FOR STOWE CELEBRATES SUMMER STOWE, VERMONT

David Reynolds, Business Development Manager. Halton Group Foodservice Division

Transcription:

End-Use Data Collection Requirements Data Trend Type Building Electrical: building electrical (main bldg. feed) HVAC Cooling: Total building electrical consumption data shall be submetered through the building EMCS or SCADA system. This trend data can sometimes be supplied by the utility provider depending on the capability of the existing building meter. It is often possible for EMCS to receive meter (pulse) signals directly from the utility provider s meter. Such meters are generally referred to in the industry as smart meters. Agencies should explore these possibilities before installing a separate sub-meter. However, when separate meters are required, they must be calibrated by the sub-meter manufacturer to match the reading of the utility provider s meter. power factor chilled water water-cooled airconditioning to collect. Cooling load data shall be collected for the main building system with one BTU meter installed in the chilled water piping where possible, preferably on the secondary side of primary/secondary distribution. For other types of distribution, BTU meters shall be installed on every chiller where conditions dictate. Note: and data collection via an electric sub-meter will not be considered an acceptable alternative to cooling tonhours and tons for chiller. The Agencies may consider installing kw meters in addition to BTU meters as a means to monitor chiller performance, but such kw meters can be installed temporarily in the form of test equipment. BTU meters are required. to collect. For centralized condenser water or cooling tower, cooling load data shall be collected for the main building system with one BTU meter where possible. Note: and data collection via an electric sub-meter will be considered an acceptable alternative to cooling ton-hours and tons when BTU meters are not practical for watercooled heat pump. 1

air-cooled DX This consumption requires EMCS/SCADA submetering to collect. However, large commercial buildings are not typically cooled with these types of. Large facilities with such are challenging to sub-meter due to the potential number of separate meters required. Possible exceptions include: Situations where a single device can meter multiple HVAC units -or- Facilities that have a relatively small number of HVAC units. purchased HVAC cooling HVAC Heating (Boiler Systems): steam boilers This applies to circumstances where the Agency purchases chilled water from an outside entity. In these situations, the Agency shall sub-meter cooling loads in the same fashion as required for chilled water. The Agency shall also report the costs monthly. to collect. Steam consumption data requires the installation of a steam-rated flow meter. steam lbs. (consumption) steam lbs./hour (demand) hot water boilers steam converters to collect. Heating hot water consumption requires the installation of a BTU meter, similar to cooling tons and ton-hours. to collect. Steam converters are heat exchangers that utilize steam for the purpose of heating water. Steam consumption data requires the installation of a steam-rated flow meter. BTUs per hour (demand) steam lbs. (consumption) steam lbs./hour (demand) purchased HVAC heating HVAC Heating (Unitary Equipment): water-cooled heat pump This applies to circumstances where the Agency purchases steam or heating hot water from an outside entity. The Agency shall sub-meter heating loads in the same fashion as required for steam or boilers. The Agency shall also report costs monthly. to collect. For centralized condenser water or cooling tower, cooling load data shall be collected for the main building system with one BTU meter where possible. Note: and data collection via an electric sub-meter will be considered an acceptable alternative to cooling ton-hours and tons when BTU meters are not practical for watercooled heat pump. see steam or boilers 2

air-cooled heat pump This consumption requires EMCS/SCADA submetering to collect. However, large commercial buildings are not typically heated with these types of. Large facilities with such are challenging to sub-meter due to the potential number of separate meters required. Possible exceptions include: Situations where a single device can meter multiple HVAC units -or- Facilities that have a relatively small number of HVAC units. electric reheat This consumption requires EMCS/SCADA submetering to collect. Large facilities with such are challenging to sub-meter due to the potential number of separate meters required. Possible exceptions include: Situations where a single device can meter multiple HVAC units -or- Facilities that have a relatively small number of HVAC units. Domestic Water Heating (High-Use Facilities Only): electric water heaters to collect. Domestic water heating consumption (kwh) shall be collected with an electric sub-meter. For circulating, a BTU meter may be utilized. -or- gas water heaters This consumption data requires sub-metering to collect. Domestic water heating consumption (CCF or therms) shall be collected with a conventional or EMCS/SCADA gas sub-meter. For circulating, a BTU meter may be utilized. CCF (consumption) -or- steam water heaters This consumption data requires sub-metering to collect. Domestic water heating consumption (steam pounds) shall be collected with a conventional or EMCS/SCADA steam sub-meter. For circulating, a BTU meter may be utilized. steam lbs. (consumption) -or- solar water heaters This consumption data requires sub-metering to collect. A BTU meter may be utilized for solar water heating when the agency deems it appropriate to do so. However, solar water heating are typically installed to supplement conventional type water heaters. Therefore, sub-metering conventional water heating in accordance with this section will capture the benefit of reduced operation due to supplemental solar water heaters. refer to other water heater types as necessary 3

Domestic Water & Sewer: domestic water This consumption data is supplied by the utility provider in monthly billing statements. For facilities with high monthly domestic water usage or for facilities that utilize domestic water for process cooling, the installation of an EMCS/SCADA flow meter should be explored in order to identify and prevent excessive consumption and leaks. At a minimum, the consumption data (gallons) provided in the utility bill shall be collected monthly. irrigation Ground Water: irrigation air-conditioning This consumption data is typically supplied by the utility provider in monthly billing statements. Irrigation supplied by domestic water must be separately metered by the utility provider and consumption data (gallons) shall be collected and reported separately from normal domestic water. Ground water is commonly used for irrigation. Ground water irrigation must be separately metered by the Agency and the consumption data (gallons) shall be collected monthly. Large may require EMCS/SCADA metering and reporting. Note: Ground water permits often require ground water withdrawal/consumption rates to be reported to specific governing authorities. Building owners should collect daily withdrawal/consumption data and review it on a monthly basis in order to ensure permit compliance and to prevent excessive consumption. Ground water is commonly used instead of cooling tower to operate air-conditioning. In such cases, ground water is pumped from the aquifer through the air-conditioner condensers and then returned to the aquifer through an injection well. There is virtually no consumption because the water is returned to the aquifer. However, ground water supply well pumps can represent a large electrical load. Flow meters for such applications are easily incorporated into most building EMCS. Conventional consumption meters shall be the minimum standard. Note: Ground water permits often require ground water withdrawal/consumption rates to be reported to specific governing authorities. Building owners should collect daily withdrawal/consumption data and review it on a monthly basis in order to ensure permit compliance and to prevent excessive consumption. 4

Reuse Water: reuse water Natural Gas: general building usage Reuse water is recycled water that is provided by the utility provider. The most common use for reuse water is irrigation, but it can be used for other non-potable purposes. Data collection for reuse water shall be based on the monthly utility bill statement. EMCS/SCADA sub-metering should be considered for high-use applications or process cooling. EMCS/SCADA should also be considered to monitor that can be supplied from both domestic water and reuse water in order to prevent cross connections. The consumption data (gallons) shall be reported separately from all other water types. This energy consumption data is intended for all nonvehicular fuel consumption that is related to the operation of a building, including emergency generators, boiler, and space heating. This consumption data is supplied by the utility provider in monthly billing statements. Total natural gas consumption (CCF or therms) shall be collected monthly. Note: This consumption data shall not be used as a substitute for heating load data when a building s boiler is fired with natural gas. See the HVAC Heating Section for heating system data requirements. CCF (consumption) Other Fuels (Fuel Oil, Diesel, & Propane): This energy consumption data is intended for all nonvehicular fuel consumption that is related to the operation of a building, including emergency generators, boiler, and space heating. This consumption data will require the installation of an in-line fuel meter to collect if none exists. general building usage Fuel consumption (gallons) shall be collected on a monthly basis. Total fuel consumption shall be read manually from a conventional in-line fuel meter or collected from an EMCS/SCADA sub-meter per the Agency s discretion. Note: This consumption data shall not be used as a substitute for heating load data when a building s boiler is fired with fuel oil. See the HVAC Heating Section for heating system data requirements. 5

Trash & Recyclables: building trash & recyclables generation Trash and recyclables quantity and cost shall be reported monthly. The quantities for trash and recyclables may need to be estimated. In such cases, the size of the container(s) shall be determined in cubic yards and the quantity of trash/recyclables generated shall be estimated as a percentage approximation of the container s fullness. cubic yards (generation) 6