Check valves, family E, type B

Similar documents
Vulcanised rubber products for cold and hot drinking water applications

Sanitary tapware: mechanical mixers

Villeroy & Boch AG. the Kiwa evaluation guideline BRL-KK621/06 Close coupled suites. EN 997: 2003 WC pans with integral trap.

Number K4126/06 Replaces K4126/05. Issued Dated Valid until Indefinite Page 1 of 6

Leadax B.V. Covenant K93792/02. Leadax

DSPA DSPA B.V. Product Certificate K86591/07 UK. Non-Pressurized Condensed Aerosol Generators and Components K86591/06 UK

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D

CPVC solvent cements for CPVC pipes and fittings

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware

BRL-K602. Datum Evaluation Guideline

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

BRL-K14008/ Evaluation guideline. for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters

BRL-K762. Datum Concept design. Evaluation Guideline. for the Kiwa product certificate for steel pipes for the transport of drinking water

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device

Evaluation Guideline

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

GASTEC QA. Approval Requirements 136

GASTEC QA. Approval Requirements 6

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

GASTEC QA. Approval Requirements 31-2

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

GASTEC QA. Approval Requirements 31-1

GASTEC QA. Approval Requirements 69-1

BRL-K Evaluation Guideline. for the Kiwa product certificate for products used for treatment and / or production of drinking water

Evaluation guideline. for the Kiwa product certificate for external Polyurethane Coatings on ductile iron pipes for underground installation

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances

BRL-K656/ Evaluation guideline. for the Kiwa product certificate for heat exchangers intended for the indirect heating of drinking water

Kiwa Regulations for Certification in accordance with the CPR

BRL-K Evaluation Guideline

Evaluation Guideline. for the Kiwa product certificate for plastics piping systems of polyethylene for the transport of drinking water and raw water

GASTEC QA. Approval Requirements 201. Amendment A1. for the GASTEC QA product certificate for Gas service lines to residences and buildings

Viega Technology GmbH & Co. KG

BRL-K619/ Evaluation Guideline. for the Kiwa product certificate for WC-pans

GASTEC QA. Approval Requirements 7. for the GASTEC QA product certificate for bendable gas meter connection pipes. KE 7 March 2012

Kiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision

0014-L-16/1 2 March Test report. EPDM Quickgoot system

BRL-K17401 Comments before.. Replaces BRL-K17401 d.d. 16 April Evaluation guideline

Hygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGAVIB VB61, VB63 Hygienic process fittings. Document ID: 35483

Vallox Oy. manufactures. over LOW POWER EFFICIENCY Specific electrical

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

KQ July 1, Evaluation Guideline

Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

fixed dry aerosol fire extinguishing components FirePro Systems Ltd.

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Kiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision

QATAR STANDARD QS SASO 2692/201 QS SASO 2692 ENERGY LABELLING REQUIREMENTS OF HOUSEHOLD ELECTRICAL CLOTHES WASHING MACHINES

DOMESTIC COMMERCIAL INDUSTRY AUTOMATIC DIRT SEPARATORS FOR HEATING, COOLING AND PROCESS SYSTEMS

WATER BOILERS CB(W), WKI, WKT, WKS

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Evaluation Guideline. for the KOMO (technical approval-with-) product certificate for

Strong partners in innovative climate technology. Comfort Air Curtains Model CA DK for Daikin VRV-system

DOMESTIC COMMERCIAL INDUSTRY AUTOMATIC DEAERATORS/ DIRT SEPARATORS FOR HEATING, COOLING AND PROCESS SYSTEMS

CVS 4 (EN 54) # # Exceptional Sound and Reliability

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC

Report of fire tests on Li-ion batteries based on condensed aerosol

Dirt Trap. Operation & Maintenance Instructions Read these operation and maintenance instructions before start up! To be held for future reference.

Suction Line SDL. Operating Instructions EN 01. for barrels and containers. To be retained for future reference. Dosing Conveying Control

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CE MARKING OF WOOD-BASED PANELS

Reaction to fire classification report No C-rev.1

Checklist for EASYZON Chlorine dioxide system

Heat Pumps, Packaging and Document Kits

Reaction to fire classification report No C

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

design BRL-K Evaluation Guideline

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Maintaining electrical supply on wood

for concrete Apolo MEA Befestigungssysteme GmbH Industriestraße Aichbach DEUTSCHLAND Apolo MEA Befestigungssysteme GmbH, Plant2 Germany

European Technical Assessment. ETA-12/0166 of 18 June English translation prepared by DIBt - Original version in German language.

Wall-hung boilers. Spare parts catalogue. ecotec plus

Fire Protection Scover

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection

Operating instructions

Test Lamp for 210 series flame detectors Non EX

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Koja Oy. manufactures ventilation units Fair 80 ec

Certified Passive House Component For cool, temperate climates, valid until 31 December 2017

KN-KWL 110 SE-EC Kontrollierte Wohnraumlüftung KN

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

PG50 Detection Gate ( : 1-loop, : 2-loop)

Customer Requirements Pre-Installation Instructions

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

Performance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CombiPrime Self-priming centrifugal pumps

Waste water ejection unit

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

4 liter Solo and 8 liter Combi

Test Report: ICL/H18/9039 Rev 1

AQUAFIT - the innovative single-lever mixer for safety and hygiene

European Technical ETA-11/0080 Assessment of 9 February 2016 General Part

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

DNV BUSINESS ASSURANCE

Transcription:

287/170315 Product certificate K6322/20 Issued 2017-08-01 Replaces K6322/19 Page 1 of 5 STATEMENT BY KIWA With this product certificate, issued in accordance with the Kiwa Regulations for Product Certification, Kiwa declares that legitimate confidence exists that the products supplied by NEOPERL GmbH as specified in this product certificate and marked with the Kiwa -mark in the manner as indicated in this product certificate may, on delivery, be relied upon to comply with Kiwa evaluation guideline BRL K629/03: Anti-pollution check valves Family E, Types A, B, C, and D, dated 01-02-2012, which includes the requirements of EN 13959:2004: Anti- pollution check valves - DN 6 to DN 250 inclusive family E, type A, B, C and D. Luc Leroy Kiwa Publication of this certificate is allowed. Advice: consult www.kiwa.nl in order to ensure that this certificate is still valid. Kiwa Nederland B.V. Sir Winston Churchilllaan 273 P.O. Box 70 2280 AB RIJSWIJK The Netherlands Tel. +31 88 998 44 00 Fax +31 88 998 44 20 info@kiwa.nl www.kiwa.nl Supplier NEOPERL GmbH Klosterrunsstrasse 11 79379 MÜLLHEIM/BADEN Germany Tel. +49 763 1188 0 Fax +49 763 1188 175 www.neoperl.de Importer NEOPERL B.V. Marchandweg 65 3771 MN Barneveld Netherlands Tel. +31 342 429 040 Fax +31 342 429 045 www.neoperl.nl Certification process consists of initial and regular assessment of: quality system product

page 2 of 5 PRODUCT SPECIFICATION The products mentioned below belong to this product certificate. Nominal diameter Article number Name DW check valves 30.4009.0 DW10/DN6-JR DN 6 30.4010.0 DW10/DN6 30.4011.0 DW11/DN6 DN 8 30.4013.0 DW13/DN8-KK 30.4014.0 DW14/DN10 30.4064.0 DW15/DN10-KG 30.4068.0 DW15/DN10-KK 30.4094.0 DW15/DN10-PR 30.4031.0 DW14/DN10-GF-AF 30.4033.0 DW14/DN10-GF 30.4043.0 DW15/DN10-GF DN 12 30.4016.0 DW16/DN12 30.4019.0 DW19/DN12 DN 15 30.4073.0 DW20/DN15-1T 30.4075.0 DW20/DN15-EPDM DN 20 30.4022.0 DW22/DN20-KK OD & OF & OV & NV & WV check valves DN 6 31.4285.0 OF7/DN6 31.4201.0 OD8/DN6 DN 8 31.4208.0 OF10/DN8 31.4210.0 OV10/DN8 31.4264.0 OD13/DN10 31.0014.0 OF15/DN10-GF-F1 31.0015.0 OF15/DN10-F1 31.0047.0 OV15/DN10-GF-F1 31.4215.0 OV15/DN15 31.0001.0 OV15/DN15-EPDM 31.4815.0 OV15/DN15-UW 31.0006.0 OF15/DN15 31.0032.0 OF15/DN15-EPDM DN 15 31.0022.0 OV15/DN15-HT 31.0007.0 OF15/DN15-GF 31.0024.0 OF15/DN15-HT 31.4216.0 NV15/DN15 31.0002.0 NV15/DN15-EPDM 31.4816.0 NV15/DN15-UW 31.4217.0 WV15/DN15 31.4220.0 OV20/DN20 31.0003.0 OV20/DN20-EPDM 31.0012.0 OV20/DN20-HT 31.4820.0 OV20/DN20-UW 31.4520.0 OF20/DN20 31.0057.0 OF20/DN20-EPDM DN 20 31.4221.0 NV20/DN20 31.0004.0 NV20/DN20-EPDM 31.0011.0 NV20/DN20-HT 31.0023.0 NV20/DN20-EPDM-CA 31.4821.0 NV20/DN20-UW 31.4222.0 WV20/DN20

page 3 of 5 31.0028.0 OV25/DN25-HT 31.4225.0 OV25/DN25 31.4825.0 OV25/DN25-UW DN 25 31.4226.0 NV25/DN25 31.0009.0 NV25/DN25-EPDM 31.4826.0 NV25/DN25-UW 31.4227.0 WV25/DN25 31.4233.0 NV32/DN32 DN 32 31.0017.0 NV32/DN32-EPDM 31.4232.0 OV32/DN32 31.0030.0 OV32/DN32-HT 31.4241.0 NV40/DN40 31.0019.0 NV40/DN40-EPDM DN 40 31.4240.0 OV40/DN40 31.0046.0 OV40/DN40-HT 31.4247.0 WV40/DN40 31.4251.0 NV50/DN50 DN 50 31.4250.0 OV50/DN50 31.0020.0 NV50/DN50-EPDM CV check valves 31.3001.0 CV15/DN15-SHORT 31.4015.0 CV15/DN10 31.4114.0 CV14/DN10 31.4134.0 CV14/DN10-AF DN 15 31.4213.0 CV18/DN15

page 4 of 5 CV-FR check valves 31.4144.0 31.4146.0 31.4147.0 31.4148.0 31.4150.0 31.4151.0 31.4152.0 31.4153.0 31.4154.0 31.4155.0 31.4156.0 31.4157.0 31.4158.0 31.4159.0 31.4160.0 31.4164.0 31.4165.0 31.2004.1 31.2006.1 31.2007.1 31.2008.1 31.2010.1 31.2011.1 31.2012.1 31.2013.1 31.2014.1 31.2015.1 31.2016.1 31.2017.1 31.2018.1 31.2019.1 31.2020.1 31.2024.1 31.2028.1 31.2030.1 31.2032.1 CV14-FR 2,0L CV14-FR 3,0L CV14-FR 3,5L CV14-FR 4,0L CV14-FR 5,0L CV14-FR 1.5gpm CV14-FR 6,0L CV14-FR 1.75gpm CV14-FR 7,0L CV14-FR 2.0gpm CV14-FR 8,0L CV14-FR 2,2gpm CV14-FR 9,0L CV14-FR 2,5gpm CV14-FR 10,0L CV14-FR 12,0L CV14-FR 15,0L CV15-FR 2,0L CV15-FR 3,0L CV15-FR 3,5L CV15-FR 4,0L CV15-FR 5,0L CV15-FR 1.5gpm CV15-FR 6,0L CV15-FR 1.75gpm CV15-FR 7,0L CV15-FR 2.0gpm CV15-FR 8,0L CV15-FR 2,2gpm CV15-FR 9,0L CV15-FR 2,5gpm CV15-FR 10,0L CV15-FR 12,0L CV15-FR 14,0L CV15-FR 15,0L CV15-FR 16,0L

page 5 of 5 FITNESS FOR CONTACT WITH DRINKING WATER This product is approved on the basis of the requirements for hygienic aspects set in the "Regeling materialen en chemicaliën drink- en warm tapwatervoorziening" ( Materials and chemicals in the supply of drinking water and warm tap water Regulation ; published in the Government Gazette). These hygienic aspects are based on two main criteria. The product shall permanently comply with: The product recipe approved during the assessment procedure. This recipe is not to be changed without prior approval by Kiwa according to the Kiwa approval procedure for the hygienic aspects; Specific product requirements for the hygienic aspects. The recipe and specific product requirements are laid down in the, for confidentiality reasons, undisclosed appendix hygienic aspects to this certificate. MARKING The Kiwa -mark products are marked with the word mark KIWA or KK. Place of the mark: on the housing or on the valve. Compulsory specifications: name or mark of manufacturer: on the housing or the valve; nominal size: on the housing or the valve; indication for direction of flow. Method of marking: non-erasable; visible after assembly. APPLICATION AND USE The check valves are intended as backflow prevention devices. Check valves with a nominal diameter less than or equal to 50 mm are intended for application in drinking water installations with a maximum constant water temperature of 65 C and, for a maximum period of 1 hour, a water temperature of 90 C. Check valves with a nominal diameter greater than 50mm are intended for use in a water temperature of up to 65 C. Check valves are intended for application in drinking water installations with a maximum operating pressure of 1000 kpa. RECOMMENDATIONS FOR CUSTOMERS Check at the time of delivery whether: the supplier has delivered in accordance with the agreement; the mark and the marking method are correct; the products show no visible defects as a result of transport etc. If you should reject a product on the basis of the above, please contact: NEOPERL GmbH and, if necessary, Kiwa Nederland B.V. Consult the supplier s processing guidelines for the proper storage and transport methods.