Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings

Similar documents
Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

Field Study of Diffuse Ceiling Ventilation Performance in a Landscape Office

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Comparison of radiant and convective cooling of office room: effect of workstation layout

Air and operative temperature measurements in a plus-energy house under different heating strategies

Can painted glass felt or glass fibre cloth be used as vapour barrier?

An interdisciplinary approach to identify adaptation strategies that enhance flood resilience and urban liveability

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Feasible Working Domains Decision Support for Heat Pump Projects

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems Nielsen, Peter Vilhelm; Jakubowska, Ewa

Thermal Environment Evaluation in Commercial Kitchens of United States

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Maximum Obtainable Efficiency For Engines And Refrigerators Based On The Stirling Cycle

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

State of the Art of HVAC Technology in Europe and America

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Energy and Exergy Performances of Air-Based vs. Water-Based Heating and Cooling Systems: A Case Study of a Single-Family House

Villa Bagatelle Technical Report

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

Solar Sustainable Heating, Cooling and Ventilation of a Net Zero Energy House

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

A study of Transient Performance of A Cascade Heat Pump System

Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016

COOLED PLATE TESTS ON TEXTILE MATERIALS IN SIMULATED COCKPIT UNDER SOLAR RADIATION

AN ENVIRONMENT FRIENDLY COOLING OPTION

On the Architectural Engineering Competences in Architectural Design MSc in Engineering with Specialization in Architecture Kirkegaard, Poul Henning

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Recent Advances in Energy, Environment and Economic Development

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

Cooling load calculations of radiant and all-air systems for commercial buildings

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Operation and maintenance service provision in uncertain times the case of the FLSmidth Group during the Arab Spring

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

EXPERIMENTAL INVESTIGATION OF THE AIR CLEANING EFFECT OF A DESICCANT DEHUMIDIFIER ON PERCEIVED AIR QUALITY

Comparison of fin-and-tube interlaced and face split evaporators with flow maldistribution

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Influence of Compressor Control Strategy on Energy Efficiency and Product Temperature for Professional Counter Cabinets

Dynamic performance of a novel dew point air conditioning for the UK buildings

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Optimisation of cooling coil performance during operation stage for improved humidity control

Hygrothermal evaluation of a museum storage building based on actual measurements and simulations

Functionality Inspection of Interconnected Fire Protection Systems

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Enhancement of COP in Vapour Compression Refrigeration System

High efficient heat pump system using storage tanks to increase COP by means of the ISEC concept - Part 1: Model validation

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Efficiency of Non-Azeotropic Refrigerant Cycle

Purdue e-pubs. Purdue University

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

CLEAN-AIR Heat Pump. - Reduceret energiforbrug til ventilation af bygninger ved luftrensning integreret med luft varmepumpe

Energy Recovery Ventilation

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Modelling of Split Condenser Heat Pump with Limited Set of Plate Heat Exchanger Dimensions

Effect of magnetic field on the performance of new refrigerant mixtures

Two Stage Indirect/Direct Evaporative Cooling

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

IEA EBC Annex 59 - Possibilities, limitations and capacities of indoor terminal units

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Active desiccant integration with packaged rooftop HVAC equipment

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

Performance of Chilled Beam with Radial Swirl Jet and Diffuse Ceiling Air Supply in Heating Mode

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

Low GWP Refrigerants for Air Conditioning Applications

Liquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements. White Paper

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

ANSI/AHRI Standard 911 (SI) 2014 Standard for Performance Rating of Indoor Pool Dehumidifiers

Experimental study on automotive cooling and heating air conditioning system using CO 2 as a refrigerant

Scholars Research Library

Evaporative Cooling. HEVAC Association. Humidity Group. an alternative and supplement to mechanical cooling

Continuous Strip Reduction Test Simulating Tribological Conditions in Ironing

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Heat pump and energy recovery systems

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

Impact of Air Distribution on Heat Transfer during Night-Time Ventilation

R07. Answer any FIVE Questions All Questions carry equal marks *****

Households' energy use - which is the more important: efficient technologies or user practices? Gram-Hanssen, Kirsten

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Review on Waste Heat Recovery Techniques in Air Conditioning Application

Transcription:

Downloaded from orbit.dtu.dk on: May 5, 218 Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings Fang, Lei; Yuan, Shu; Yang, Jianrong Published in: Proceedings of the 9th international conference on indoor air quality, ventilation & energy conservation in buildings Publication date: 216 Document Version Peer reviewed version Link back to DTU Orbit Citation (APA): Fang, L., Yuan, S., & Yang, J. (216). Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings. In Proceedings of the 9th international conference on indoor air quality, ventilation & energy conservation in buildings General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings Lei Fang 1*, Shu Yuan 1 and Jianrong Yang 2 1 Department of Civil Engineering, Technical University of Denmark, Denmark 2 Shanghai Research Institute of Building Sciences * Corresponding email: fl@byg.dtu.dk ABSTRACT This paper presents a simple cooling technology using flash water evaporation. The technology combines a water atomizer with a plate heat exchanger used for heat recovery of a ventilation system. It is mainly used to cool the ventilation airflow from outdoors and is particularly suitable to be used in warm/hot and dry environment where dehumidification of outdoor air is not needed. A laboratory experiment was designed and conducted to evaluate the cooling effectiveness of this technology. The experiment was conducted in a twin-climate chamber. One chamber simulated warm/hot and dry outdoor environments and the other simulated an air-conditioned indoor environment. The flash water evaporation cooling device was installed in the chamber that simulated indoor environment. The air from the chamber simulating outdoor environment was introduced into the cooling device and cooled by the flash water evaporation. Two outdoor summer climates were simulated in the study, i.e. the design summer climate of Las Vegas and the extreme summer climate of Copenhagen represented hot/dry and warm/dry climates. The results showed that the flash evaporative cooling technology, a simple and green cooling technology, is effective for ventilation and air-conditioning in warm/hot and dry climate zones. The technology can provide fresh outdoor air with a temperature of 4 to 7 C lower than room air temperature. KEYWORDS: Indirect evaporative cooling, heat recovery, water atomizer and Ventilation INTRODUCTION In modern buildings, most of the energy consumption of HVAC is used for conditioning the outdoor air supply for ventilation. Ventilation is important to maintain good air quality indoors that is essential for heath and comfort of occupants. Most of the air-conditioning systems use electricity to drive compression cooling devices. The power generation processes usually involve in the generation of greenhouse gas and the most of the refrigerants have high global warming potential (GWP). All of them contribute to the global warming. In Europe, heat recovery is widely used in mechanical ventilation systems to recover the energy from the exhaust air. The existing air to air heat recovery technologies can be classified into two categories, i.e. sensible heat recovery and total heat recovery (enthalpy recovery), (ASHRAE 24). Typical heat and enthalpy exchange efficiencies range from 55% to 8% (Dieckmann et al. 23). The sensible heat recovery technology employed a heat exchanger that exchanges sensible heat between incoming outdoor air and the exhaust indoor air. The best counter-flow sensible heat exchange technology can recover 8% to 85% sensible heat (temperature efficiency) from the exhaust air (Klingenburg Catalogs, 216).

Such heat recovery technology is suitable especially for winter application when the heating load is mainly sensible heat. In summer season, especially in the hot and humid climate where dehumidification produces the major cooling load, enthalpy recovery is needed. However in the area where summer climate is warm and dry, the sensible heat recovery could also be used for ventilation. The enthalpy recovery technology using flash evaporative cooling was studied in the Centre of Indoor Environment and Energy (ICIEE) at the Technical University of Denmark (Fang et al. 215) where the enthalpy efficiency of a counter flow heat exchanger combined with the flash evaporative cooling technology reached 7% for air-conditioned environment with warm and humid outdoor climate. The same study also observed the temperature efficiency of the same technology used as an indirect evaporative air cooling device when operating at warm/hot and dry outdoor environment. The experiment discovered a very high temperature efficiency of the technology. The study showed that flash evaporative cooling technology combined with counter flow air to air heat exchanger may partly or fully replace vapor compression cooling for air conditioning. This technology is low cost and completely green. This paper reports the experimental study and the results of the cooling effect of the flash evaporative cooling technology used in warm/hot and dry climate. Outdoor air in Exhaust out Heat exchanger Atomizer water supply mist atomizer Exhaust in Outdoor air out Demineral water Coagulating water Condensing water Water tank drain Figure 1. Principle of the developed total heat recovery unit.

METHODS Design of the flash evaporative cooling device The design of the flash evaporative cooling device is shown in Figure 1. It includes a counter flow air to air heat exchanger, an ultra-sonic atomizer and a water supply and collection system. The exhaust indoor air is first humidified by an ultra-sonic atomizer. The ultra-sonic atomizer breaks water into huge amount of ultra-fine water droplets the ultra-fine water mist. Due to the evaporation of atomized water, the temperature of the exhaust air is cooled down to its wet-bulb temperature. At the same time, the exhaust air is saturated. Since the atomized water is more than what is needed to saturate the exhaust air, large quantity of the surplus ultra-fine water mist is carried by the exhaust air and enters the heat exchanger. Inside the heat exchanger, the ultra-fine water droplets absorb the heat that is transferred from the incoming outdoor air and evaporate immediately. The incoming outdoor air exchanges heat with the exhaust indoor air that carries ultra-fine water mist at its wet-bulb temperature. The heat exchange due to the temperature difference and water evaporation of the ultra-fine water mist cools the incoming outdoor air into wet-bulb temperature of the indoor air which could be many degrees lower than the indoor air temperature. Thus the ventilation outdoor air can be used to cool indoor environment that reduces the cooling demand for ventilation. The water collecting system collects the surplus atomized water coagulated in the heat exchanger and the condensed water from the incoming outdoor air, if any, for recycling. Experimental set up and design The performance of the designed flash evaporative cooling device was tested in a twinclimate chamber. One chamber simulated warm and dry outdoor climate and the other simulated an air-conditioned indoor climate. A test rig of the flash evaporative cooling device was developed as shown in Figure 2. The test rig include a counter flow heat exchanger, an ultra-sonic atomizer, a water supply and collecting system, air channels with a supply and an exhaust fan, airflow control system, four temperature and humidity sensors installed on the inlet and outlet of both sides of the heat exchanger and a data acquisition system to log all the data collected in the experiment. The test rig was installed in the climate chamber that simulated indoor climate condition and the exhaust air supply of the heat exchanger was taken directly from that chamber. The outdoor air supply of the heat exchanger was taken from the other chamber simulating outdoor climate conditions. The experiment was designed to study the technology applied in the Danish summer climate (mild warm and dry climate) and the Las Vegas summer climate (hot and dry climate). For the Danish climate, the study was conducted in three indoor climate conditions and the extreme outdoor summer climate condition of Copenhagen as shown in Table 1. For the Las Vegas climate, the study was conducted in one indoor climate condition and one design outdoor summer climate condition as shown in Table 2. For the study in both Copenhagen and Las Vegas climate conditions, the experiments were conducted at three levels of air flow rate, i.e. the rated airflow rate of the heat exchanger (2L/s) and ±25% of the rated airflow rate (15L/s and 25L/s).

Figure 2. The experimental set-up. Table 1. Experimental conditions at the simulated extreme summer outdoor climate of Copenhagen (3 C/4%RH) Indoor climate Airflow rate (L/s) conditions 15 2 25 25 C and 35% RH X X X 25 C and 5% RH X X X 25 C and 65% RH X X X Table 2. Experimental conditions at the simulated summer outdoor climate of Las Vegas (4 C/11%RH) Indoor climate Airflow rate (L/s) condition 15 2 25 25 C and 3% RH X X X Since the heat recovery of ventilation in summer of the two cities involves mainly in dry cooling of the outdoor ventilation airflow, temperature efficiencies was used to evaluate the effectiveness of heat recovery technology. The temperature efficiency was calculated using the following formula. Temperature efficiency: (1) Where: is the temperature efficiency; ; ; are temperatures of the outdoor air, indoor air and supply air (outdoor air after cooling by the heat exchanger). RESULTS Figure 3 shows the measured cooling effect of flash water evaporative cooling technology at the simulated extreme summer climate of Copenhagen. The temperature efficiency and the temperature of outdoor air after being cooled by the heat exchanger (the supply air temperature to the ventilated room) are presented at three levels of airflow rate in the heat

exchanger and the experiment was repeated at three different levels of indoor humidity at 25 C. Outdoor condition: 3ºC/4%RH Indoor condition: 25 ºC/35%RH Outdoor condition: 3ºC/4%RH Indoor condition: 25ºC/35%RH supply Supply outside Outdoor 3 25 2 15 1 5 15L/s 2L/s 25L/s air flow rate (L/s) Supply air temperature vs 4 3 2 1 15L/s 2L/s 25L/s Outdoor condition: 3ºC/4%RH Indoor condition: 25 ºC/5%RH 3 25 2 15 1 5 15L/s 2L/s 25L/s Outdoor condition: 3ºC/4%RH Indoor condition: 25ºC/5%RH Supply air temeprature vs 4 3 2 1 15L/s 2L/s 25L/s Supply Outside Outdoor Outdoor condition:3ºc/4%rh Indoor condition: 25ºC/65%RH Outdoor condition: 3ºC/4%RH Indoor condition: 25ºC/65%RH supply Supply outside Outdoor 3 25 2 15 1 5 15L/s 2L/s 25L/s Supply air temperature vs 4 3 2 1 15L/s 2L/s 25L/s Figure 3. The measured temperature efficiencies and temperatures of supply and outdoor air at the three levels of airflow rate. The experiment was conducted at the simulated extreme Copenhagen summer climate and three air-conditioned indoor climate. The measured cooling effect of flash evaporative cooling technology at the simulated summer climate of Las Vegas is shown in Figure 4. The temperature efficiency and the temperature of

outdoor air after being cooled by the heat exchanger (the supply air temperature to the ventilated room) are presented at three levels of airflow rate in the heat exchanger. Outdoor condition:4ºc/11%rh Indoor condition: 25ºC/3%RH Outdoor condition: 4ºC/11%RH Indoor condition: 25ºC/3%RH Supply Outside Outdoor 2 15 1 5 15L/s 2L/s 25L/s Supply air temperature vs 5 4 3 2 1 15L/s 2L/s 25L/s Figure 4. The measured temperature efficiencies and temperatures of supply and outdoor air at the three levels of airflow rate and environmental conditions of Las Vegas summer climate. DISCUSSION Although the principle of indirect evaporative cooling is well understood, the practical approaches to achieve such cooling can be different and lead to significant different cooling effectiveness. The flash evaporative cooling technology utilized the rapid evaporation of ultra-fine water droplets to intensify the evaporative cooling. The results of this experiment showed that all temperature efficiencies measured at the two summer climate conditions tested were above 1%. This was because that the heat exchanger was not only used to recover the sensible heat from exhaust air but also provided additional cooling for the outdoor supply air resulted in lower temperature of the supplied outdoor air than that of indoor air. The higher temperature efficiency observed the stronger cooling effect obtained to cool the supplied outdoor air. Compared to the existing indirect evaporative cooling technology using water spray, wet filter or other wetted media, the flash evaporative cooling technology has much higher cooling effectiveness because it requires much less water in the cooling process and the ultra-fine water droplets evaporate more efficient. The water mist used for the evaporative cooling can be controlled just enough for the cooling process. This will avoid additional cooling used to cool the excess sprayed water for the evaporative cooling. The experiment was conducted at three different airflow rates, i.e. the rated airflow rate of the heat exchanger (2L/s) and ±25% of the rated airflow (15 and 25 L/s). The results showed that change of airflow rate around the rated airflow of the heat exchanger has almost no impact on the temperature efficiency of the flash evaporative cooling technology provided that sufficient micro-droplet mist is introduced into the exhaust airflow. The experiment further showed that the temperature efficiency decreased with increasing indoor air humidity. Figure 5 compares the temperature efficiency and supply outdoor air temperature after the air was cooled by the heat exchanger at the three levels of indoor relative humidity tested. The results clearly showed that the supply air temperature increased

with increasing indoor air humidity. This was due to the fact that the minimum temperature that flash evaporative cooling can reach is limited by the wet-bulb temperature of indoor air. Increase indoor air humidity results in the increase of its wet-bulb temperature. When indoor relative humidity increases to 1%, the effect of evaporative cooling disappears. However, in the warm and dry summer climate zones, indoor humidity of the most of office and residential buildings is well below 1% leaving sufficient room for the evaporative cooling effect. Outdoor condition: 3ºC/4%RH Indoor condition: 25ºC, AQ: 2L/s Outdoor condition:3ºc/4%rh Indoor condition:25 ºC, AQ:2L/s Supply Outside Outdoor 3 25 2 15 1 5 35% 5% 65% Indoor relative humidity (%) Supply air temperature vs 35 3 25 2 15 1 5 35% 5% 65% Indoor relative humidity (%) Figure 5. Comparison of temperature efficiencies and supply air temperatures at three levels of indoor humidity with the extreme Copenhagen summer outdoor climate. The flash evaporative cooling technology is simple and effective. It is particularly suitable to be used in the warm/hot and dry climate zone for air-conditioning especially for the buildings that has already installed sensible heat exchangers in the ventilation system for the exhaust heat recovery. Considering its low cost and zero impact on environment, the flash evaporative cooling technology should have great potential in practice for air-conditioning. CONCLUSIONS The flash evaporative cooling technology, a simple and green cooling technology, is effective for ventilation and air-conditioning in warm/hot and dry climate zones. The technology can provide fresh outdoor air with a temperature of 4 to 7 C lower than room air temperature. ACKNOWLEDGEMENT This study is financially sponsored by Bjarne Saxhofs foundation and Shanghai Landsea Architecture Technology Co. Ltd. REFERENCES ASHRAE 24, Indirect evaporative air cooling, ASHRAE Handbook - HVAC Systems and Equipment, Chapter 44.21. John Dieckmann, Kurt W. Roth and James Brodrick, 23, Air to air energy recovery heat exchangers, ASHRAE Journal, August 23, p. 57-58. Klingenburg Catalogs, 216, Counterflow-Plate Heat Exchanger Type GS and GS-K, http://www.klingenburg-usa.com.

Lei Fang, Shu Yuan and Jianrong Yang, 215, Enhance total heat recovery for ventilation with flash evaporative cooling, Proceedings of Healthy Buildings 215 (Europe), Eindhoven, Holland.