Operating Instructions

Similar documents
Operating Instructions

Operating Instructions

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions

Operating Instructions

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH

Inverter Split-type Room Air Conditioner

AIR CONDITIONER (SPLIT TYPE)

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

Owner s Manual Super-Slim Four-Way Cassette

Operating Instructions Air Conditioner

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Operating Instructions FS Multi Air Conditioner

KSD-35 DR11 KUE-35 DVN11

Operating Instructions FS Multi Air Conditioner

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

DAIKIN ROOM AIR CONDITIONER. Operation Manual

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

AIR CONDITIONER OPERATING MANUAL. Cassette type. Indoor Unit AUTG30KRLA AUTG36KRLA AUTG45KRLA AUTG54KRLA. PART No

NEXXOS INVERTER USER MANUAL

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

OWNER S MANUAL AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-B10, 13, 16, 22N3KV2 Series RAS-M07, 24N3KV2 Series

LG Convertible-Type Air Conditioner

Owner s Manual CS

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

SPLIT - TYPE ROOM AIR CONDITIONER

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

R410A SPLIT SERIES FIXED SPEED

Operating Instructions Air Conditioner

GDDEM10 DEHUMIDIFIER

HEAT & COOL MODEL (REVERSE CYCLE)

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Indoor Unit (2 Series)

OWNER S MANUAL AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-B10, 13, 16, 22N3KV2-E1. Outdoor unit RAS-10, 13N3AV2-E1 RAS-16, 22N3AV2-E ENGLISH

PORTABLE AIR CONDITIONER

OPERATING MANUAL UTY-RNNYM P/N English

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Bosch Split-Type Ductless Air Conditioner / Heat Pump

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Compact Cassette Type

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

Indoor Unit (2 Series)

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Operating Instructions Air Conditioner

Dehumidifier. Instruction Manual

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

OWNER S MANUAL VMH 09/12/18/24

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

30-pint Dehumidifier User Guide

General safety precautions English

INDOOR UNIT/OUTDOOR UNIT

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

General safety precautions English

CASSETTE TYPE

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

Room Air Conditioners

SPLIT TYPE. Instruction manual

INDOOR UNIT/OUTDOOR UNIT

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

R410A SPLIT SERIES DC INVERTER QUICK COUPLING

Portable Room Air Conditioner and Heat Pump

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Transcription:

Operating Instructions Air Conditioner Model No. Indoor Unit CS-E9PD3EA CS-E12PD3EA CS-E12QD3EAW Outdoor Unit Single Split (R410A) CU-E9PD3EA CU-E12PD3EA CU-E12QD3EA * Outdoor Unit Multi Split (R410A) CU-2E15PBE CU-2E18PBE CU-3E18PBE CU-4E23PBE CU-4E27PBE CU-5E34PBE CU-2E12SBE CU-2E15SBE CU-2E18SBE CU-3E23SBE * Outdoor Unit Multi Split (R32) CU-2Z35TBE CU-2Z41TBE CU-2Z50TBE CU-3Z52TBE CU-3Z68TBE CU-4Z68TBE CU-4Z80TBE CU-5Z90TBE Operating Instructions 2-11 Air Conditioner * Kindly consult authorised dealer for connectivity validity. Bedienungsanleitung 12-21 Klimagerät * Wenden Sie sich bei Fragen zur Gültigkeit der Konnektivität an Ihren Fachhändler. Handleiding 22-31 Airconditioner * Wij verzoeken u vriendelijk een geautoriseerde dealer advies te vragen over de aansluitmogelijkheden. Istruzioni di funzionamento 32-41 Condizionatore d aria * Si prega di consultare un rivenditore autorizzato per la validità della connettività. Οδηγίες λειτουργίας 42-51 Κλιματιστικό * Συμβουλευτείτε τον εξουσιοδοτημένο αντιπρόσωπο για την καταλληλότητα της σύνδεσης. Comment utiliser l appareil 52-61 Climatiseur * Consultez un revendeur agréé pour connaître la validité de la connectivité. Instrucciones de funcionamiento 62-71 Climatizador de aire * Consulte a un distribuidor autorizado para conocer la validez de la conectividad. Instruções de funcionamento 72-81 Aparelho de ar condicionado * Consulte o representante autorizado para validar a conectividade. Инструкции за работа Климатик 82-91 * Моля, обърнете се към оторизиран дилър относно валидността на връзките. Български Português Español Français Eλληνικά Italiano Nederlands Deutsch English ACXF55-10820

Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached. Before operating the unit, read these operating instructions thoroughly and keep them for future reference. The illustrations in this manual are for explanation purposes only and may differ from the actual unit. They are subject to change without notice for future improvement. Multi air conditioner system Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit. For complete product features, please refer catalogue. Indoor units Indoor units It is possible to operate the indoor units individually or simultaneously. The priority of operation is placed on the fi rst unit that turned on. During operation, HEAT and COOL modes cannot activate at the same time for different indoor units. The power indicator blinks to indicate the indoor unit is standing by for a different operation mode. Outdoor unit 2 Operation conditions Use this air conditioner under the following temperature range. DBT : Dry bulb temperature WBT : Wet bulb temperature CU-E9PD3EA, CU-E12PD3EA, CU-E12QD3EA Indoor Outdoor DBT WBT DBT WBT COOL Max. 32 (89.6) 23 (73.4) 43 (109.4) 26 (78.8) Min. 16 (60.8) 11 (51.8) -10 (14.0) - HEAT Max. 30 (86.0) - 24 (75.2) 18 (64.4) Min. 16 (60.8) - -10 (14.0) - C ( F) (temperature) Multi split outdoor unit CU-2E15PBE, CU-2E18PBE, CU-3E18PBE, CU-4E23PBE, CU-4E27PBE, CU-5E34PBE, CU-2E12SBE, CU-2E15SBE, Indoor Outdoor CU-2E18SBE, CU-3E23SBE, CU-2Z35TBE, CU-2Z41TBE, CU-2Z50TBE, CU-3Z52TBE, CU-3Z68TBE, CU-4Z68TBE, CU-4Z80TBE, CU-5Z90TBE DBT WBT DBT WBT COOL Max. 32 (89.6) 23 (73.4) 46 (114.8) 26 (78.8) Min. 16 (60.8) 11 (51.8) -10 (14.0) - HEAT Max. 30 (86.0) - 24 (75.2) 18 (64.4) Min. 16 (60.8) - -15 (5.0) -16 (3.2) C ( F) (temperature)

Quick guide Remote control preparation Open the cover to use the buttons 1 Press CLOCK Table of contents Safety precautions...4-7 How to use...8-9 OFF / ON 2 Press TIMER UP or to select current day 3 Press SET to confirm Information...8-9 To set the timer...9-10 English TIMER/CLOCK UP 4 Repeat steps 2 and 3 to set the current time Troubleshooting... 11 SET CLOCK CANCEL 1 2 3 Basic operation OFF / ON 1 TIMER/CLOCK UP FAN SPEED 2 SET QUIET/ AIR SWING POWERFUL TEMP 3 CLOCK CANCEL AC RC CHECK RESET 1 Start/stop the operation Please note that the OFF indication is as follows: To start: To stop: 2 Select the desired mode AUTO DRY HEAT COOL 3 Select the desired temperature Selection range: 16 C ~ 30 C / 60 F ~ 86 F. 3

Safety precautions To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below: This appliance is not intended for accessibility by the general public. For appliance filled with R32 (mild flammable refrigerant). If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire. WARNING This sign warns of death or serious injury. Remote control Indoor unit Air inlet vent Air outlet vent Outdoor unit Air inlet Power supply Air outlet WARNING 4 CAUTION This sign warns of injury or damage to property. The instructions to be followed are classifi ed by the following symbols: This symbol denotes an action that is PROHIBITED. These symbols denote actions COMPULSORY. Indoor unit and outdoor unit This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Please consult authorised dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fire. Confi rm with authorised dealer or specialist on usage of any specifi ed refrigerant type. Using refrigerant type other than the specifi ed may cause product damage, burst and injury etc.

Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re. Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury. Do not touch the outdoor unit during lightning, it may cause electric shock. Do not expose yourself directly to cold air for a long period to avoid excess cooling. Do not sit or step on the unit, you may fall down accidentally. Remote control Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries. Power supply Do not use a modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re. To prevent overheating, fi re or electric shock: Do not share the same power outlet with other equipment. Do not operate with wet hands. Do not over bend the power supply cord. Do not operate or stop the unit by inserting or pulling out the power plug. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualifi ed persons in order to avoid a hazard. It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fi re. To prevent overheating, fi re or electric shock: Insert the power plug properly. Dust on the power plug should be periodically wiped with a dry cloth. Stop using the product if any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock) Examples of abnormality/failure The ELCB trips frequently. Burning smell is observed. Abnormal noise or vibration of the unit is observed. Water leaks from the indoor unit. Power cord or plug becomes abnormally hot. Fan speed cannot be controlled. The unit stops running immediately even if it is switched on for operation. The fan does not stop even if the operation is stopped. Contact your local dealer immediately for maintenance/ repair. This equipment must be earthed to prevent electrical shock or fi re. Prevent electric shock by switching off the power supply and unplug: -Before cleaning or servicing, -When extended non-use, or -During abnormally strong lightning activity. English Safety precautions 5

Safety precautions WARNING Precaution for appliance filled with R32 Pay careful attention to the following points when operating the appliances and dealing with different refrigerants. The appliance shall be installed, and/or operated in a room with floor area larger than Amin (m²) and keep away from ignition sources, such as heat/sparks/ open fl ame or hazardous areas such as gas appliances, gas cooking, reticulated gas supply systems or electric cooking appliances, etc. (Refer to Table A of Installation instructions table for Amin (m²)) Be aware that refrigerant may not contain an odour, highly recommended to ensure suitable flammable refrigerant gas detectors are present, operating and able to warn of a leak. Since the working pressure is higher than that of refrigerant R22 models, some of the piping and installation and service tools are special. Especially, when replacing a refrigerant R22 model with a new refrigerant R32 model, always replace the conventional piping and fl are nuts with the R32 and R410A piping and fl are nuts on the outdoor unit side. The R32 flare nut and pipe on the outdoor unit side can also be used for a R410A model. Models that use refrigerant R32 and R410A have a different charging port thread diameter to prevent erroneous charging with refrigerant R22 and for safety. Therefore, check beforehand. [The charging port thread diameter for R32 and R410A is 12.7 mm (1/2 inch).] Be extra careful so that foreign matter (oil, water, etc.) does not enter the piping. Also, when storing the piping, securely seal the opening by pinching, taping, etc. (Handling of R32 is similar to R410A.) This appliance shall be stored in a well ventilated area. This appliance shall be stored in a room without continuously operating open fl ames and ignition sources. This appliance shall be stored so as to prevent mechanical damage from occurring. Do not use means to accelerate the defrosting process or to clean, other than those recommended by manufacturer. Any unfi t method or using incompatible material may cause product damage, burst and serious injury. Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, fl ame, sparks, or other sources of ignition. Else it may explode and cause injury or death. 6

CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water, benzine, thinner or scouring powder to avoid damage or corrosion at the unit. Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc. Do not use any combustible equipment in front of the airfl ow outlet to avoid fire propagation. Do not expose plants or pet directly to airflow to avoid injury, etc. Do not touch the sharp aluminium fi n, sharp parts may cause injury. Do not switch ON the indoor unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit. Do not install the unit in oily and smoky areas to prevent damage to the unit. Do not dismantle the unit for cleaning purpose to avoid injury. Do not step onto an unstable bench when cleaning the unit to avoid injury. Do not place a vase or water container on the unit. Water may enter the unit and degrade the insulation. This may cause an electric shock. Do not open window or door for long time during operation, it may lead to ineffi cient power usage and uncomfortable temperature changes. Prevent water leakage by ensuring drainage pipe is: -Connected properly, - Kept clear of gutters and containers, or -Not immersed in water After a long period of use or use with any combustible equipment, aerate the room regularly. After a long period of use, make sure the installation rack does not deteriorate to prevent the unit from falling down. Remote control Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control. To prevent malfunction or damage of the remote control: Remove the batteries if the unit is not going to be used for a long period of time. New batteries of the same type must be inserted following the polarity stated. Power supply Do not disconnect the plug by pulling the cord to prevent electric shock. English Safety precautions 7

How to use Single Multi Single split system Multi split system Remote control display FAN SPEED TIMER/CLOCK UP CLOCK OFF / ON SET CANCEL FAN SPEED To select fan speed (Remote control display) QUIET/ AIR SWING POWERFUL CHECK Press and hold for approximately 10 seconds to show temperature setting in C or F. Not applicable RESET TEMP For AUTO, the indoor fan speed is automatically adjusted according to the operation mode. AC RC Press to restore the remote control to default setting. Not used in normal operations. To select operation mode AUTO - For your convenience Unit selects operation mode every 10 minutes according to setting temperature and room temperature. HEAT - To enjoy warm air Unit takes a while to warm up. COOL - To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode. DRY - To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation. QUIET/ POWERFUL To switch between quiet & powerful QUIET POWERFUL NORMAL QUIET: To enjoy quiet operation This operation reduces airfl ow noise. POWERFUL: To reach temperature quickly Single This operation stops automatically after 20 minutes. To eliminates the POWERFUL indicator Multi QUIET/ POWERFUL after 20 minutes operation, press button again. Press the button again or turn OFF the unit to stop this operation. Can be activated in all modes and can be cancelled by pressing the respective button again. Information Information for Users on Collection and Disposal of Old Equipment These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling of old products, please take them to applicable collection points, in accordance with your national legislation. By disposing of these products correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation. For business users in the European Union If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information. [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. 8

To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Please consult authorised dealer. Switch off the power supply before cleaning. Do not touch the aluminium fi n, sharp parts may cause injury. Do not use benzine, thinner or scouring powder. Use only soap ( ph 7) or neutral household detergent. Do not use water hotter than 40 C / 104 F. For seasonal inspection after extended non-use No obstruction at air inlet and air outlet vents. These units are mounted inside the ceiling. It uses external air intake vent and air outlet vent to operate. Please consult your nearest dealer for seasonal inspection. After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents: COOL: 8 C / 14.4 F HEAT: 14 C / 25.2 F For extended non-use Activate HEAT mode for 2~3 hours to remove moisture left in the internal parts thoroughly to prevent mould growth. Turn off the power supply. NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY then please consult authorised dealer under the following conditions: Abnormal noise during operation. Water/foreign particles have entered the remote control. Water leaks from Indoor unit. Circuit breaker switches off frequently. Power cord becomes unnaturally warm. Switches or buttons are not functioning properly. To set the timer Daily timer setting To turn ON or OFF the unit at a preset time. 1 2 TIMER/CLOCK UP CLOCK SET 3 CANCEL 1 Press TIMER to enter timer mode Press once to change the display from clock to timer or vice-versa. Press for 4 seconds to change the display from daily timer to weekly timer or viceversa. 2 Select ON or OFF timer 4 Example: OFF at 22:00 3 Set the time UP 4 Confirm SET To cancel, press CANCEL. When ON timer is set, the unit may start early before the actual set time in order to achieve the desired temperature on time. Timer operation is based on the clock set in the remote control and repeats daily once set. The timer closest to the current time will be activated fi rst. If timer is cancelled manually or due to power failure, you can restore the previous setting by pressing SET. English How to use / Information / To set the timer 9

To set the timer Weekly timer setting Promotes energy saving by allowing you to set up to 6 programmes in any given day. TIMER/CLOCK UP CLOCK SET CANCEL Lights up if Timer operation is selected Programme number in a day (1 ~ 6) Indicates the selected day Indicates the next timer operation day Time to be selected (10 minutes step) OFF Timer ON Timer Day to be selected 1. Press TIMER for 4 seconds to change display to weekly timer. 2. Press TIMER UP or to select your desired day. 3. Press to confirm your selection. 4. 1 will be blinking, press to set programme 1. 5. Press TIMER to select ON or OFF timer. 6. Press TIMER UP or to select your desired time. If you want to set the timer together with your desired temperature, press to TEMP select the temperature. 7. Press SET to confirm programme 1. The selected day will be highlighted with. After 2 seconds, the display will move to the next programme. Repeat steps 4 to 7 to set programmes 2 to 6. During timer setup, if no button is pressed within 30 seconds, or if the SET button is pressed, the setting at that moment is confirmed and timer setup is ended. To check current timer programme 1. Press TIMER to enter timer mode and press to enter day setting. 2. Press TIMER UP or until your desired day is shown, press to confi rm your selection. 3. Press TIMER programmes. UP or to check the set To modify current timer programme or add new timer programme 1. Press TIMER to enter timer mode and press to enter day setting. 2. Press TIMER shown. UP or until your desired day is 3. Perform steps 4 to 7 of Weekly timer setting to modify existing timer programme, or add any timer programme. To cancel current timer programme 1. Press to enter day. UP 2. Press TIMER or until your desired day is shown, press to enter programme setting. UP 3. Press TIMER or until your desired day is shown. Press CANCEL to cancel the programme and will disappear. To disable/enable Weekly Timer To disable weekly timer setting, press TIMER CANCEL, then press. To enable previous weekly timer setting, press TIMER, then press SET. Note Daily timer and weekly timer could not be set at the same time. Same timer programme cannot be set in the same day. 10

Troubleshooting The following symptoms do not indicate malfunction. Symptom Cause Mist emerges from indoor unit. Condensation effect due to cooling process. Water fl owing sound during operation. Refrigerant fl ow inside the unit. The room has a peculiar odour. This may be due to damp smell emitted by the wall, carpet, furniture or clothing. Indoor fan stops occasionally during automatic This helps to remove the surrounding odour. fan speed setting. Operation is delayed a few minutes after The delay is a protection to the unit s compressor. restarting. Outdoor unit emits water/steam. Condensation or evaporation occurs on pipes. TIMER indicator is always on. The timer setting repeats daily once set. Power indicator blinks during operation and The unit is in defrost mode, and the melted frost is the indoor fan is stopped. drained from the outdoor unit. Indoor fan stops occasionally during heating To avoid unintended cooling effect. operation. POWER indicator blinks before the unit is This is a preliminary step in preparation for the switched on. operation when the ON timer has been set. Cracking sound during operation. Changes of temperature caused the expansion/ contraction of the unit. Discoloration of some plastic parts. Discoloration is subject to material types used in plastic parts, accelerated when exposed to heat, sun light, UV light or environmental factor. English To set the timer / Troubleshooting Check the following before calling for servicing. Symptom Check Operation in HEAT/COOL mode is not working Set the temperature correctly. effi ciently. Close all doors and windows. Clear any obstruction at the air inlet and air outlet vents. Noisy during operation. Check if the unit has been installed at an incline. The unit does not work. Check if the circuit breaker is tripped. Check if timers have been set. The following symptoms indicate malfunction. Symptom Check At remote control, OFF indicator does not Use remote control to retrieve error code as follows. shown on remote control display but operation LED OFF. Operation LED Ensure the operation LED is in OFF condition. OFF Indicator 1 Press CHECK for 5 seconds TIMER/CLOCK UP CLOCK OFF / ON SET CANCEL FAN SPEED QUIET/ AIR SWING POWERFUL AC TEMP RC 2 Press TIMER UP or If error code and abnormality can be identifi ed, the operation LED will be ON continuously, then jot down the error code. 3 Press again for 5 seconds to quit CHECK checking 4 Reveal the error code to authorised dealer CHECK RESET 2 1 / 3 11

Panasonic Corporation Website: http://www.panasonic.com Panasonic Corporation 2017 Printed in Malaysia Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, Germany ACXF55-10820 SC0117-0