Added cooling capacity of 140 W and 320 W (watercooled), (air-cooled). Thermo-con. controlled to a constant temperature

Similar documents
Added cooling capacity of 140 W. (air-cooled).

Can precisely control the temperature of a heat source or process fluid.

Added cooling capacity of 140 W. (air-cooled).

Mountable in a 19-inch rack

HEB Series. Peltier-Type Thermoelectric Bath

Thermoelectric Bath. Series HEB

Thermoelectric Bath. Series HEB

HEB Series. Thermoelectric Bath

Precisely control the temperature of the circulating fluid by using the Peltier device. Refrigerant-free and environmentally friendly.

10 c to 60 c 300 W, 500 W, 750 W. direct temperature control for chemical liquids!! HED Series. Industry-leading withstand pressure 0.35 MPa!!

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Peltier-Type Temperature Control System for Chemicals. Fluororesin heat exchanger allows direct temperature control for chemicals!!

Water-cooled Thermo-chiller

Refrigerated Thermo-chiller

SEMI Standard S2-0703, S8-1103, F

Chiller Lineup. Thermo-chiller. A chiller is used to control the temperature of circulating fluid and supply it to the heat source.

Type of Fluorinated fluids / Ethylene glycol aqueous solution / circulating fluid: Clear water, Deionized water Temperature range setting:

Water-cooled Thermo-chiller

Water-cooled Thermo-chiller

Circulating Fluid Temperature Controller Refrigerated Thermo-cooler

Water-cooled Thermo-chiller

A Chiller is equipment to control temperature of customers heating sources. Application Examples

0.1 c. R134a (HFC) Thermo-chiller. ( A device for circulating a fluid ) Series HRZ. with a constant temperature

Refrigerated Thermo-cooler

±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions

Large energy saving by triple control!

Large energy saving by triple control!

using heat exhausted by refrigerating circuit.

Operation Manual. Thermo Electric Bath HEBC002-WA10 HEBC002-WB10

RoHS HRG(C)005 (Existing model) (mm) 69 kg 5100 W

Refrigeration air dryer

Large energy saving by triple control!

Recirculating Coolers

Lightweight and Compact

Technical Data C O N T E N T S

Refrigerated Air Dryer

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Operation Manual Installation Operation

Advantages / Characteristics

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

Customized Industrial Products

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

Refrigerated Air Dryer

Refrigerated Air Dryer

% by up ctoond re-heater and

Pressure Switches Precautions 1 Be sure to read this before handling.

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Operation Manual Installation Operation

Refrigerated Air Dryer

General Specifications

Chapter 5 Inspection and maintenance

Improved productivity Two-stage detection

Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop.

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Document No. IZ*-OMP0064 C. P r o d u c t Ionizer. Model/Series. IZS4 Series

M7100 Pressure Transducer

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

Specifications. The Liquid Super Separator is a new concept of air filtration that is totally different from

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

Desicators & Dry Cabinets

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Screw Water Cooled Chiller SCW210

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

Operation Manual Installation Operation

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Bench-Top Type Temperature (& Humidity) Chamber

Models Series Series

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Series Temperature Controller Instruction Sheet

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

Operation Manual. (Version 1.5.1)

13-1. Temperature Regulator

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

Multistage Ejector MODEL / Series / Product Number

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

MD-MINI Dry Bath. Instruction Manual

S304 and S305 Dust Emission Monitors. User Manual. Distributor

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

Water Circulator (Chiller) & Cold Trap

AOYUE 968A+ INT. Deluxe Repairing System INSTRUCTION MANUAL

Thermal Shock Chamber TSE 11

Compact Ultra Low Temperature Chamber

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

P/N CC-100. Coolant Circulator. Operation manual

Operation Manual Air-refrigerated Thermo cooler HRG010-A HRG015-A SMC Corporation Save This Manual Carefully for Use at Any Time

Operation Manual Installation Operation

Neostat Room Thermostat, Room Humidistat

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Transcription:

Peltier-Type Chiller Thermo-con Air-cooled Water-cooled Series Can precisely control the temperature of a heat source or process fluid. Precisely control the temperature of the circulating fluid by using the Peltier device. Generates little vibration, and is refrigerant-free and environmentally friendly. Can control the temperature of the heat source by using the external temperature sensor (sold separately). (Automatically adjusts to the effects of ambient temperature.) Temperature range setting: 5 to 14 F (1 to 6 C) Temperature stability: ±.18 to.54 F (±.1 to.3 C) Air-cooled Water-cooled Series -A Air-cooled: Can be used in the environments with no cooling equipment. Cooling capacity: 23 W, 6 W Cooling tower, etc. Cooling tower Fan Facility water Thermo-con Cools or heats the circulating fluid Series -W Thermo-con Added cooling capacity of 14 W and 32 W (watercooled), and 6 W (air-cooled). 14W: W184 x H262 x D321 32W: W184 x H262 x D321 controlled to a constant temperature Peltier device (Thermo-module) Circulating fluid Water Heat source Exchanges heat with the circulating fluid to maintain a constant temperature. Circulating fluid Water, Fluorinated fluid 23W: W21 x H393 x D436 6W: W24 x H39 x D455 Water-cooled: Can be used in the environments with facility water equipment. Cooling capacity: 14 W, 32 W, 6 W, 12 W Water-cooled 2% ethylene glycol Heat source Air-cooled RoHS RoHS Water-cooled 6W: W24 x H39 x D455 12W: W3 x H448 x D523 X-ray diagnostic instrument Blood preservation equipment Electron microscope etc. Note) Except 6, 12 Temperature control of chamber electrode Electron microscope Laser machining etc. HRG HRS HRZ HRZD HRW HEB HED Technical Data Related Products 127

Compliant with safety standard for medical equipment IEC 661-1 (Air-cooled/2-A series) Power supply: Applicable to 1 V to 24 V (Air-cooled/-A series, Water-cooled/1-W, 3-W) Suitable to fluorinated fluids (Fluorinert TM FC-3283, GALDEN HT135) (Water-cooled/6-W, 12-W) Compatible with ethylene glycol 2% (Water-cooled/1-W, 3-W) Learning Control Function (Temp. control by external temperature sensor) This function adjusts the fluid temperature to the set value with an automatic offset setting. Set the external temperature sensor at the circulating fluid inlet located just in front of the heat source, which allows the Thermo-con to sample the fluid temperature. This function is effective when automatically adjusting for heat exhaust from piping, etc. If the external temperature sensor is installed directly on the heat source, the learning control function may not work property due to large heat volume or large temperature difference. Be sure to install the sensor at the circulating fluid inlet. Principle of Peltier Device (Thermo-module) A Peltier device (thermo-module) is a plate type element, inside which P-type semicon-ductors and N-type semiconductors are located alternately. If direct current is supplied to the Peltier device (thermo-module), heat is transferred inside the device, and one face generates heat and increases temperature while the other face absorbs heat and decreases temperature. Therefore, changing the direction of the current supplied to the Peltier device (thermo-module) can achieve heating and cooling operation. This method has a fast response and can shift quickly between heating and cooling, so temperature can be controlled very precisely. Cooling Heat suction (cooling) Heating Heat generation (heating) Air-cooled Series -A Electron flow N P Electron hole flow Electron flow N P Electron hole flow Fan Current Heat generation (heating) DC power supply Cooling Heat suction (cooling) Fan Current Heat suction (cooling) DC power supply Heating Heat generation (heating) Water-cooled Series -W Electron flow N P Electron Electron N P Electron hole flow flow hole flow Facility water Current Heat generation (heating) DC power supply Facility water Current Heat suction (cooling) DC power supply 128

Construction and Principles Air-cooled Series -A Figure 1 Power switch Noise filter Power supply & Controller Controller Fan Switching power supply PE Peltier device (Thermo-module) Heat exchanger ( side) Heat exchanger (Cooling side) T Temperature sensor OUT IN supply port (Tank lid) HRG HRS Level switch Fan Pump Tank Flow switch (option) drain port HRZ Water-cooled Series -W HRZD Figure 1 Power supply & Controller Controller Fan Switching power supply Power switch PE Noise filter HRW Peltier device (Thermo-module) Heat exchanger ( side) Heat exchanger (Cooling side) T Temperature sensor Level switch 1 Flow switch 3 OUT IN supply port (Tank lid) HEB Facility water IN Facility water OUT Pump Circulating 2 tank Circulating fluid drain port Supply tank *1 Optional setting for the 1 and 3 *2 Not built in the 1 and 3 *3 Optional setting for the 1 and 3 only HED Figure 2 Thermo-con Example of circulating fluid piping Target of temperature control The Thermo-con is constructed as shown in Figure 1. It interposes a Peltier device (thermo-module) between the heat exchangers for the circulating fluid and facility water and controls the pulse width of supply direct current to achieve the target outlet temperature of circulating fluid precisely. The circulating fluid returns to the tank, and is transferred by the pump which is built in the Thermo-con, and goes through the heat exchangers and internal sensors and out from the circulating fluid outlet. Figure 2 shows an example of circulating fluid piping. The circulating fluid is transferred at a constant temperature by the pump. Technical Data Related Products 129

When to Use Air-Cooled and Water-Cooled Thermo-con Both air-cooled and water-cooled Thermo-cons are available. Select a proper Thermo-con by referring to the following. Air-cooled No facility water equipment Frequent piping changes Water-cooled Need to avoid effects of ambient temperature. Want to reduce the installation space. Can install the unit easily without facility water equipment. Can reduce the piping installation labor since facility water piping is not required. Since the unit is water-cooled, the ambient temperature will have little effect. Can reduce the space since the unit is compact. Application Examples Air-cooled Semiconductor Example: Temperature control of a chamber electrode Upper electrode Water-cooled Medical Air-cooled Example: Blood preservation Wafer H H L L Lower electrode Etching equipment Spatter equipment Cleaning equipment Coating equipment Dicing equipment Tester, etc. X-ray diagnostic instrument MRI Blood preservation equipment Machine tool Air-cooled Water-cooled Example: Laser machining Analysis Air-cooled Water-cooled Example: Electronic microscope Electronic microscope CRT H H L L Wire cutting Grinder Spot welding Plasma welding Laser machining, etc. Temperature-controlling the laser generating tube enables the laser wavelength to be optimised, improving the accuracy of the machined cross sectional area. Electron microscope X-ray analytical instrument Gas chromatography Sugar level analytical instrument, etc. Prevents the distortion caused by the heat generated by the electronic gun in an electronic microscope. Bonding of DVD including next generation Air-cooled Water-cooled Cooling of semiconductor laser Air-cooled Water-cooled Temperature control of die-cast mold Air-cooled Water-cooled 13

Features Model Selection Page 128 to 13 Page 132, 133 Air-cooled Series -A How to Order/Specifications Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet) Parts Description Dimensions Connectors Alarm/Maintenance Options Specific Product Precautions Page 134 Page 135 Page 136 Page 137, 138 Page 139 Page 14 Page 141 Page 142 to 144 HRG HRS HRZ HRW HRZD Water-cooled Series -W How to Order/Specifications Page 146, 147 Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet)/ Pressure Loss in Facility Water Circuit Page 148 to 15 Parts Description Page 151 Dimensions Page 152 to 154 Connectors Page 155 Alarm/Maintenance Page 156 Options Page 157 Specific Product Precautions Page 158, 159 Related Products HEB HED Technical Data 131

Series Model Selection Guide to Model Selection 1. What radiation method will be used? Without a cooling tower Air-cooled -A series With a cooling tower Water-cooled -W series When to Use Air-cooled and Water-cooled Thermo-con <Air-cooled> No facility water equipment Can install the unit easily without facility water equipment. Frequent piping changes Can reduce the piping installation labor since facility water piping is not required. <Water-cooled> Need to avoid effects of ambient temperature. Since the unit is water-cooled, the ambient temperature will have little effect. Want to reduce installation space. Can reduce the space since the unit is compact. 2. How much is the temperature in degrees centigrade for the circulating fluid? Temperature range which can be set with the Thermo-con: 5 to 14 F (1 to 6 C) If a lower temperature (down to 4 F ( 2 C)) or higher temperature (up to 194 F (9 C)) than this range is necessary, select the Thermo-chiller HRZ series. 3.What kind of the circulating fluids will be used? s that can be used in the Thermo-con Model 1-W, 3-W 6-W, 12-W 2-A, 6-A Clear water Fluorinert TM FC-3238 GALDEN HT135 2% ethylene glycol : Usable : Unusable 4. How much cooling capacity required? Allows a safety factor of 2% over the capacity that is actually required, taking into account the changes in the operating conditions. If a larger capacity than this Thermo-con is necessary, select the Thermo-cooler HRG series or Thermo-chiller HRZ series. Example 1 When the heat generation amount in the customer s machine is known. Heat generation amount: 4 W Cooling capacity = Considering a safety factor of 2%, 4 x 1.2 = 48 W 132

Model Selection Series Guide to Model Selection Example 2 Obtain the temperature difference between inlet and outlet by circulating the fluid inside the customer s machine. Heat generation amount Q : Unknown temperature difference T (= T2 T1) :.8 C (.8 K) outlet temperature T1 : 25 C (298.15 K) return temperature T2 : 25.8 C (298.95 K) flow rate L : 3 L/min : Water Density γ: 1 x 1 3 kg/m 3 Thermo-con Specific heat C: 4.2 x 1 3 J/(kg K) Q = T x L x γ x C T2: Return temperature 6 x 1.8 x 3 x 1 x 1 3 x 4.2 x 1 3 L = T = T2 T1 6 x 1 H =167 W L Cooling capacity = Considering a safety factor of 2%, T1: Outlet temperature 167 W x 1.2 = 2 W Example 3 Cooled substance total volume V Cooling time h Cooling temperature difference T Refer to the information shown below for the typical physical property values by circulating fluid. Q = When the heat generation amount in the customer s machine is not known. T x V x γ x C h x 6 x 1 When cooling the object below a certain temperature in certain period of time. : 2 L = 1 x 2 x 1 x 13 x 4.2 x 1 3 15 x 6 x 1 =933 W : 15 min Cooling capacity = Considering a safety factor of 2%, 933 W x 1.2 = 112 W Precautions on Model Selection : Temperature difference: 1 C (1 K). Cool from 3 C (33 K) to 2 C (293 K). : Clear water Density γ: 1 x 1 3 kg/m 3 Specific heat C: 4.2 x 1 3 J/(kg K) Water bath After 15 min, cool 3 C down to 2 C. The flow rate of the circulating fluid depends on the pressure loss of the customer s machine and the length, diameter and resistance created by bends in the circulating fluid piping, etc. Check if the required flow rate of circulating fluid can be obtained before selecting. Circulating Fluid Typical Physical Property Values H L 2 C V Customer s machine HED HEB HRW HRZD HRZ HRS HRG Fluorinated Fluids Physical property value Temperature 1 C 2 C 5 C 8 C Water Density γ: 1 x 1 3 [kg/m 3 ] Density γ Specific heat C [kg/m 3 ] [J/(kg K)] 1.87 x 1 3.87 x 1 3 1.8 x 1 3.96 x 1 3 1.74 x 1 3 1.5 x 1 3 1.67 x 1 3 1.14 x 1 3 Specific heat C: 4.2 x 1 3 [J/(kg K)] Technical Data Related Products 133

Peltier-Type Chiller Thermo-con (Air-cooled) Series -A How to Order RoHS 2 A 5 B Cooling capacity 2 23 W 6 6 W Radiating method A Air-cooled Power supply 5 1 to 24 VAC Option Nil None F With flow switch N NPT thread The option should be specified when ordering. Communication A RS-485 B RS-232C Select B when communication is not used. Specifications (For details, please consult our Product Specifications information.) Model 2-A5A 2-A5B 6-A5A 6-A5B Cooling method Radiating method Control method Ambient temperature/humidity Operating temperature range Thermoelectric device (Thermo-module) Forced air cooling Cooling/Heating automatic shift PID control 5 to 95 F (1 to 35 C), 35 to 8%RH (no condensation) Clear water 5 to 14 F (1 to 6 C) (no condensation) Cooling capacity Heating capacity 23 W Note 1) 6 W Note 1) 6 W Note 2) 9 W Note 2) Temperature stability Note 3) Pump capacity Tank capacity ±.18 to ±.54 F (±.1 to ±.3 C) Refer to performance chart. Approx..32 gal (1.2 L) Port size IN/OUT Rc1/4 Rc3/8 Drain Wetted parts material Power supply Overcurrent protector Rc1/4 (with plug) Stainless steel 33, Stainless steel 34, EPDM, Ceramics, PPS glass 3%, Carbon, PE, Polyurethane Single-phase 1 to 24 VAC ±1%, 5/6 Hz 15 A Current consumption 8 A (1 VAC) to 3 A (24 VAC) 1 A (1 VAC) to 4 A (24 VAC) Alarm Communications RS-485 Refer to alarm function. RS-232C RS-485 RS-232C Weight Approx. 38.6 lbs (17.5 kg) (including foot for fixing) Approx. 6.6 lbs (27.5 kg) (including foot for fixing) Accessories Safety standards Power cable, Foot for fixing CE marking, UL (NRTL) standards, Safety standard for medical equipment (IEC 661-1) CE marking, UL (NRTL) standards system Electrical system Note 1) Conditions: Set temperature 77 F (25 C), Ambient temperature 77 F (25 C), Circulating flow rate.79 gpm (3 L/min) Note 2) Conditions: Set temperature 77 F (25 C), Ambient temperature 68 F (2 C), Circulating flow rate 2.11 gpm (8 L/min) Note 3) The indicated values are with a stable load without turbulence in the operating conditions. It may be out of this range in some other operating conditions. 134

Peltier-Type Chiller Thermo-con (Air-cooled) Series -A Cooling Capacity 2 8 : Clear water The values shown on the performance chart are not guaranteed, but typical. Allow margins for safety when selecting the model. 6 14 : Clear water 7 12 Cooling capacity (W) 6 5 4 3 2 1 Ambient temperature: 59 F (15 C) Ambient temperature: 77 F (25 C) Ambient temperature: 95 F (35 C) Cooling capacity (W) 1 8 6 4 2 Ambient temperature: 59 (15 C) Ambient temperature: 68 F (2 C) Ambient temperature: 86 F (3 C) HRG HRS 1 9 8 4 F 6 8 9 11 13 15 1 C 2 3 4 5 6 7 temperature Heating Capacity 2 : Clear water 6 2 18 16 4 F 6 8 9 11 13 15 1 C 2 3 4 5 6 7 temperature : Clear water HRZ HRZD Cooling capacity (W) 7 6 5 4 3 Ambient temperature: 59 F (15 C) Ambient temperature: 77 F (25 C) Ambient temperature: 95 F (35 C) Cooling capacity (W) 14 12 1 8 6 Ambient temperature: 59 F (15 C) Ambient temperature: 68 F (2 C) Ambient temperature: 86 F (3 C) HRW 2 1 4 2.1 MPa Discharge pressure.8.6.4.2 4 F 6 8 9 11 13 15 1 C 2 3 4 5 6 7 temperature Pump Capacity (Thermo-con Outlet) The pressure on the y-axis shows the discharge pressure of circulating fluid in the Thermo-con. 2 13. psi 1. 7. 4.5 15. : Clear water.12 MPa Discharge pressure.1.8.6.4.2 6 16. psi 13. 1. 7. 4.5 15. 4 F 6 8 9 11 13 15 1 C 2 3 4 5 6 7 temperature : Clear water HEB HED Technical Data Related Products..3 gpm 1 L/min.4 2.5 3.9 4 flow rate. gpm.5.75 1 1.25 1.5 1.75 2 2.25 2.5 1 L/min 2 3 4 5 6 7 8 9 1 flow rate 135

Series -A Parts Description 2 Power connector Handle Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Handle Display/Operation panel Power switch Alarm connector External temperature sensor connector Circulating fluid outlet Filter Tank lid with gasket level gauge Circulating fluid inlet Drain (circulating fluid drain port) 6 Power connector Handle Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Handle Display/Operation panel Power switch Alarm connector External temperature sensor connector Circulating fluid outlet Filter Tank lid with gasket level gauge Circulating fluid inlet Drain (circulating fluid drain port) 136

OUT IN DRAIN P24417154 I SMC THERMO-CON C US 354524 CAN/CSA STD C22.2 NO.61.1 LI MODEL No. NTERT EK S T E D CM SERIAL No. INPUT VOLTAGE MAX CURRENT HEADQUARTER ETL LISTED CONFORMS TO CERTIFIED TO UL STD 661-1 2-A5B-F JT-****(JUN,25) 1Phase,AC1-24V to 5/6Hz 8A SMC CORPORATION 4-14-1,Sotokannda,Chiyoda-ku, Tokyo 11-21,Japan OUT IN THERMO-CON MADE IN JAPAN DRAIN AC RS-232C ALARM EXT.SENSOR Peltier-Type Chiller Thermo-con (Air-cooled) Series -A Dimensions Unit: inch (mm) 2 17.2 (436) 16.3 (414) 1.8 (46) 11.8 (3) R15.7 (4) HED WARNING HAZARDOUS VOLTAGE INSIDE Contact may cause electric shock,orburn. Do not remove the panel. No user serviceable parts inside. Refer all repaird to the manufacturer. CAUTION Please keep air filter clean as performance decreases with dust build up. AT SEL RET 2.2 (57) 5.6 (142) 8.3 (21) 9.5 (24) 1.6 (27) HRG Power cable (Accessory).16 x.2 (4 x 5) Warning/Caution label Handle 5.7 (145) 15.4 (39) Model no. label Display/Operation panel 6 Power switch Tank lid with gasket Air Communication connector Alarm output connector Power connector HRS HRZ HRZD HRW HEB Air Handle External temperature sensor connector 11.7 (298) 5.7 (145) 4. (11) 2. (51) 15.5 (393) 15.2 (385) 13.7 (347) 1.2 (3) 3.8 (97) 1.9 (49) Circulating fluid outlet Rc1/4 11.1 (281) 6.2 (157) Air H L Air 1.6 (27) 1.6 (27) 13.7 (347) 11.8 (3) Foot (Accessory).5 (12) Filter cover Filter 12.6 (321) 14.3 (364) inlet Rc1/4 drain port (with plug) Rc1/4 level gauge 6. (152) 1.1 (29).8 (21) 14.1 (358) 4 x Plastic foot Option (Fitting part) NPT fitting specification (-N, -FN) outlet NPT1/4 inlet NPT1/4 drain port (with plug) NPT1/4 Power Cable (Accessory) Connector: IEC 632 C13 or equivalent Cable: 14AWG, O.D. ø8.4 Wire color Contents Black 1 to 24 VAC Black 1 to 24 VAC Green/Yellow PE Technical Data Related Products 78.8 (2) 137

OUT IN DRAIN P24417154 SMC THERMO-CON THERMO-CON MODEL No. 6-A5B SERIAL No. MP-****(Feb, 28) INPUT VOLTAGE 1Phase, 1-24V to 5/6Hz MAX CURRENT 1A HEADQUARTER SMC CORPORATION 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 11-21, Japan MADE IN JAPAN OUT IN DRAIN AC RS-232C ALARM EXT.SENSOR Series -A Dimensions 6 17.9 (455) 17. (433) 1.8 (46) 11. (28) R15.7 (4) Handle Power connector Power cable (Accessory) 15.4 (39) 15. (382) 14.2 (361) 6.3 (16) Model no. label Handle 6 1.9 (48) Circulating fluid outlet Rc3/8 Air Circulating fluid inlet Rc3/8.7 (17) 4.1 (14) 6.7 (171) Tank lid with gasket 11. (278) Air H L Communication connector Alarm output connector External temperature sensor connector Air Air 8.6 (219) 6.3 (16).4 (1) Foot (Accessory) Filter cover 13.6 (346) 15.1 (384) Filter drain port (with plug) Rc1/4 level gauge 1.3 (32) 1.4 (36) 14.2 (361) 6.9 (176) WARNING HAZARDOUS VOLTAGE INSIDE Contact may cause electric shock,orburn. Do not remove the panel. No user serviceable parts inside. Refer all repaird to the manufacturer. CAUTION Please keep air filter clean as performance decreases with dust build up. AT SEL RET 2.8 (72) 6.2 (157) 9.5 (24) 1.6 (27) 11.8 (3).16 x.2 (4 x 5) 14.6 (37) Display/Operation panel Power switch Warning/Caution label 13. (33) 11.3 (286) 1.5 (266) 9.7 (246) 14.2 (361) 4 x Plastic foot Option (Fitting part) NPT fitting specification (-N, -FN) outlet NPT3/8 inlet NPT3/8 drain port (with plug) NPT1/4 Power Cable (Accessory) Connector: IEC 632 C13 or equivalent Cable: 14AWG, O.D. ø8.4 Wire color Contents Black 1 to 24 VAC Black 1 to 24 VAC Green/Yellow PE 78.8 (2) 138

Peltier-Type Chiller Thermo-con (Air-cooled) Series -A Connectors 1. Power connector (AC) IEC 632 C14 or equivalent 1 2 Pin No. 1 2 3 Contents 1 to 24 VAC 1 to 24 VAC PE 3 2. Communication connector (RS-232C or RS-485) D-sub 9 pin (socket) Holding screw: M2.6 Pin No. 1 2 3 4 5 6-9 3. External sensor connector (EXT.SENSOR) D-sub 15 pin (socket) Holding screw: M2.6 Pin No. 1-2 3 4 5 6-14 15 Signal contents RS-232C RS-485 Unused BUS+ RD BUS SD Unused Unused Unused SG SG Unused Unused Signal contents Unused Terminal A of resistance temperature detector Terminal B of resistance temperature detector Terminal B of resistance temperature detector Unused FG 3 2 5 4 1 9 8 7 6 3 4 5 5 4 6 3 7 2 1 8 HRW HRZD HRZ HRS HRG 4. Alarm output connector (ALARM) D-sub 9 pin (pin) Holding screw: M2.6 15 14 13 12 11 1 9 Pin No. 1 2 3 4-5 6 7 8 9 Signal contents Contact a for output cut-off alarm (open when alarm occurs) Common for output cut-off alarm Contact b for output cut-off alarm (closed when alarm occurs) Unused Contact a for upper/lower temp. limit alarm (open when alarm occurs) Common for upper/lower temp. limit alarm Contact b for upper/lower temp. limit alarm (closed when alarm occurs) Unused 6 1 2 7 3 4 5 8 9 HEB HED Technical Data Related Products 139

Series -A Alarm This unit is equipped as standard with a function allowing 15 kinds of alarms to display on the LCD and can be read out by serial communication. Also, it can generate relay output for upper/lower temperature limit alarm and output cut-off alarm. Alarm Alarm code WRN ERR ERR1 ERR3 ERR4 ERR11 ERR12 Alarm description Upper/Lower temp. limit alarm CPU hung-up CPU check error Back-up data error EEPROM writing error DC power supply failure Internal temp. sensor high temp. error Operation status Continue Main reason The temperature has exceeded the upper or lower limit of the target temperature. The CPU has crashed due to noise, etc. The contents of the CPU cannot be read out correctly when the power supply is turned on. The contents of the back-up data cannot be read out correctly when the power supply is turned on. The data cannot be written to EEPROM. The DC power supply has failed (due to fan stop or abnormal high temperature) or the thermo-module has been short-circuited. The internal temperature sensor has exceeded the upper limit of cut-off temperature. Internal temp. sensor ERR13 low temp. error The internal temperature sensor has exceeded the lower limit of cut-off temperature. ERR14 Thermostat alarm The thermostat has been activated due to filter clog or fan/pump failure, etc. ERR15 Abnormal output alarm Continue The temperature cannot be changed even at 1% output due to overload or disconnection of the thermo-module. ERR16 Low flow rate alarm (option) The flow rate of the circulating fluid has dropped. ERR17 Internal temp. sensor disconnection alarm The internal temperature sensor has been disconnected or short-circuited. ERR18 External temp. sensor The external temperature sensor has been disconnected or short-circuited. (Only detected Continue disconnection alarm when in learning control or external tune control) ERR19 ERR2 Abnormal auto tuning alarm Low fluid level alarm Auto tuning has not been completed within 2 minutes. The amount of circulating fluid in the tank has dropped. Maintenance Maintenance of this unit is performed only in the form of return to and repair at SMC s site. As a rule, SMC will not conduct on-site maintenance. Separately, the following parts have a limited life and need to be replaced before the life ends. Parts Life Expectation Description Expected life Pump 3 to 5 years Fan DC power supply 5 to 1 years 5 to 1 years Possible failure The bearing is worn so the pump fails to transfer the circulating fluid, which results in temperature control failure. The bearing uses up lubrication and makes the fan unable to supply enough air, which deteriorates the cooling and heating capacity. The capacity of the electrolytic condenser decreases, and causes abnormal voltage which results in DC power supply failure and stops the Thermo-con. Display panel 5, hours (approx. 5 years) The display turns off when the backlight of the LCD reaches the end of its life. 14

F Option symbol Series -A Options With Flow Switch F With flow switch Note) Options have to be selected when ordering the Thermo-con. It is not possible to add them after purchasing the unit. This is an ON/OFF switch detecting low levels of the circulating fluid. When the fluid volume is 1 L/min. or less, ERR16 is displayed and the Thermo-con stops. This switch is installed between the circulating fluid inlet and the tank, and built into the Thermo-con. Refer to page 129. Type Aircooled Applicable model 2-A5-F 6-A5-F HRG N Option symbol NPT Thread HRS N NPT thread HRZ The connection parts of circulating fluid piping, facility water piping and circulating fluid drain port are NPT thread type. Type Aircooled Applicable model 2-A5-N 6-A5-N Related Products HRZD Technical Data HED HEB HRW 141

WARNING HAZARDOUS VOLTAGE INSIDE Contact may cause electric shock,orburn. Do not remove the panel. No user serviceable parts inside. Refer all repaird to the manufacturer. CAUTION Please keep air filter clean as performance decreases with dust build up. SMC THERMO-CON AT SEL RET WARNING HAZARDOUS VOLTAGE INSIDE Contact may cause electric shock,orburn. Do not remove the panel. No user serviceable parts inside. Refer all repaird to the manufacturer. CAUTION Please keep air filter clean as performance decreases with dust build up. SMC THERMO-CON AT SEL RET WARNING HAZARDOUS VOLTAGE INSIDE Contact may cause electric shock,orburn. Do not remove the panel. No user serviceable parts inside. Refer all repaird to the manufacturer. CAUTION Please keep air filter clean as performance decreases with dust build up. SMC THERMO-CON AT SEL RET WARNING HAZARDOUS VOLTAGE INSIDE Contact may cause electric shock,orburn. Do not remove the panel. No user serviceable parts inside. Refer all repaird to the manufacturer. CAUTION Please keep air filter clean as performance decreases with dust build up. SMC THERMO-CON AT SEL RET P24417154 P24417154 P24417154 P24417154 Series -A Specific Product Precautions 1 Be sure to read this before handling. Refer to back page 1 for Safety Instructions and back pages 2 to 5 for Temperature Control Equipment Precautions. Warning System Design 1. This catalog shows the specifications of the Thermo-con. 1. Check detailed specifications in the separate Product Specifications, and evaluate the compatibility of the Thermo-con with customer s system. 2. Although the protection circuit as a single unit is installed, the customer is requested to carry out the safety design for the whole system. Handling Caution Radiation Air 1. The inlet for radiation air must not be exposed to particles and dust as far as possible. 2. Do not let the inlet and outlet for radiation air get closed. <2> If radiation is prevented, the set temperature may not be achieved depending on the value of the set temperature and the load. Keep a space of 3.9 in (1 mm) for opened rear side or 7.9 in (2 mm) for closed rear side respectively. Warning 1. Thoroughly read the Operation Manual. Read the Operation Manual completely before operation, and keep this manual available whenever necessary. 2. If the set temperature is repeatedly changed by 5 F (1 C) or more, the Thermo-con may fail in short periods of time. Intake 3.9 in (1 mm) or more Discharge 3.9 in (1 mm) or more The rear side is opened. Operating Environment/Storage Environment Warning 1. Keep within the specified ambient temperature and humidity range. Also, if the set temperature is too low, condensation may form on the inside of the Thermo-con or the surface of piping even within the specified ambient temperature range. Dew condensation can cause failure, and so must be avoided by considering operating conditions. 2. The Thermo-con is not designed for clean room usage. It generates dust from the pump inside the unit and the cooling fan. 3. Low molecular siloxane can damage the contact of the relay. Use the Thermo-con in a place free from low molecular siloxane. <6> Intake 7.9 in (2 mm) or more Intake 19.7 in (5 mm) or more Discharge 7.9 in (2 mm) or more Discharge 19.7 in (5 mm) or more The rear side is closed. The rear side is opened. Intake Discharge The rear side is closed. 19.7 in (5 mm) or more 19.7 in (5 mm) or more Note) The space must be 19.7 in (5 mm) or more. Be sure that the ambient temperature is within the specification range. 142

Series -A Specific Product Precautions 2 Be sure to read this before handling. Refer to back page 1 for Safety Instructions and back pages 2 to 5 for Temperature Control Equipment Precautions. Caution Caution Radiation Air 3. If more than one Thermo-con is used, consider their arrangement so that the downstream sides of the Thermo-cons suck radiation air from the upstream sides. Otherwise, the performance at the downstream sides may deteriorate. Also, the set temperature may not be achieved depending on the value of the set temperature and the load. In such a case, take countermeasures such as changing the direction of the Thermo-cons to prevent the deterioration of performance. 4.If dust adheres to the filter, remove dust with a vacuum cleaner or a dry cloth. 5. Do not operate without the filter. Otherwise, dust may accumulate on the heat sink and electrical components, causing abnormal heating. Circulating Fluid 1. Use tap water or fluid which will not damage the wetted material. (Stainless steel 33, Stainless steel 34, EPDM, Polypropylene, PE, PPE, Ceramics, Polyurethane) 2. Deionized water (with an electrical conductivity of approx. 1 µs/cm) can be used, but may lose its electrical conductivity. Also, if a facility supplying deionized water is used, the Thermocon may be damaged by static electricity. 3. If deionized water is used, bacteria and algae may grow in short periods of time. If the Thermo-con is operated with bacteria and algae, its cooling capacity or the capacity of the pump may deteriorate. Exchange all deionized water regularly depending on the conditions (once a month as a guide). 4. If using a fluid other than water, please contact SMC beforehand. 5. The maximum operating pressure of circulating fluid circuit is 14.5 psi (.1 MPa). If this pressure is exceeded, leakage from the tank in the Thermo-con can result. 6. Select a pipe with a length and diameter which allow a flow rate of.26 gpm (1 L/min) or more (2) or.79 gpm (3 L/min) or more (6) for the circulating fluid. If the flow rate is less than these values, the Thermo-con cannot provide precise control, but also can fail because of the repeated cooling and heating operation. 7. A magnet driven pump is used as a circulat-ing pump. A fluid which contains metal powders such as iron powder cannot be used. 8. The Thermo-con must not be operated with-out circulating fluid. The pump can break due to idling. Caution Circulating Fluid 9. If the tank lid is opened after the supply of circulating fluid, the circulating fluid may spill out depending on the condition of external piping. 1. If an external tank is used, the circulating fluid may spill out from the internal tank lid depending on where the external tank is installed. Check that the internal tank has no leakage if using an external tank. 11. If there is a point where fluid is released to atmosphere externally (tank or piping), minimize the piping resistance at the circulating fluid return side. If the piping resistance is too large, the piping may be crushed, or the built-in circulator tank may be deformed or cracked because the pressure in the piping for return will become negative. The built-in circulator tank is made of resin (PE). Therefore, the tank may be crushed if the pressure is negative. Special attention must be paid if the flow rate of the circulating fluid is high. To avoid getting negative pressure less than 2.9 psi (.2 MPa), the piping for return should be as thick and short as possible to minimize the piping resistance. It is also effective to restrict the flow rate of circulating fluid or remove the gasket of internal tank for the release to atmosphere. 12. Fluorinated fluid is outside of the specifications. If it is used in the Thermo-con, static electricity will be generated by the flow of fluid. This static electricity may be discharged to the board of the Thermo-con, causing damage or operation failure and loss of data of such as set temperature. Also, as the specific gravity of the fluorinated fluid is 1.5 to 1.8 times of water, the pump will be overloaded, which also causes fluorinated fluid to be outside the specifications. Therefore, if fluorinated fluid is used, please contact SMC and we will introduce a suitable special product (water-cooled type). 13. Avoid operation with cavitation or bubbles due to low fluid level in the tank. This may shorten the pump life. 14. If clear water is used, it should satisfy the quality standards shown below. Clear Water (as Circulating Water) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-2-1994 Cooling water system Circulating type Supply water Influence Item Unit Standard value Scale Corrosion generation ph (at 77 F (25 C)) Electrical conductivity (77 F) Chloride ion (Cl ) Sulfuric acid ion (SO 2 4 ) Acid consumption amount (at ph4.8) Total hardness Calcium hardness (CaCO 3 ) Ionic state silica (SiO 2 ) Iron (Fe) Copper (Cu) Sulfide ion (S 2 ) Ammonium ion (NH 4+ ) Residual chlorine (Cl) Free carbon (CO 2 ) [µs/cm] 6. to 8. 1 to 3 5 or less 5 or less 5 or less 7 or less 5 or less 3 or less.3 or less.1 or less Should not be detected..1 or less.3 or less 4. or less In the case of [MΩcm], it will be.3 to.1. : Factors that have an effect on corrosion or scale generation. Even if the water quality standards are met, complete prevention of corrosion is not guaranteed. Standard item Reference item HRG HRS HRZ HRZD HRW HEB HED Technical Data Related Products 143

Caution Warning Series -A Specific Product Precautions 3 Be sure to read this before handling. Refer to back page 1 for Safety Instructions and back pages 2 to 5 for Temperature Control Equipment Precautions. Communication 1. The set value can be written to EEPROM, but only up to approx. 1 million times. In particular, pay attention to how many of times the writing is performed using the communication function. Maintenance 1. Prevention of electric shock and fire Do not operate the switch with wet hands. Also, do not operate the Thermo-con with water left on it. 2. Action in the case of error If any error such as abnormal sounds, smoke, or bad smell occurs, cut off the power at once, and stop supplying and conveying fluid. Please contact SMC or a sales distributor to repair the Thermo-con. 3. Regular inspection Check the following items at least once a month. The inspection must be done by an operator who has sufficient knowledge and experience. a) Check of displayed contents. b) Check of temperature, vibration and abnormal sounds in the body of the Thermo-con. c) Check of the voltage and current of the power supply system. d) Check for leakage and contamination of the circulating fluid and intrusion of foreign objects to it, and subsequent replacement of the fluid. e) Check for flow condition, temperature and filter of radiation air. 144

Peltier-Type Chiller Thermo-con (Water-cooled) Series -W How to Order Note) Except 6, 12 RoHS 14 W, 32 W 3 W 5 B Cooling capacity 1 14 W 3 32 W Radiating method W Water-cooled Power supply 5 1 to 24 VAC Specifications (For details, please consult our Product Specifications information.) Option Nil None F With flow switch N NPT thread L With level switch The option should be specified when ordering. Communication A RS-485 B RS-232C Select B when communication is not used. W Note 1) Model 1-W5A 1-W5B 3-W5A 3-W5B Cooling method Radiating method Control method Ambient temperature/humidity Operating temp. range Cooling capacity Thermoelectric device (Thermo-module) Water-cooled Cooling/Heating automatic shift PID control 5 to 95 F (1 to 35 C), 35 to 8%RH (no condensation) Clear water, 2% ethylene glycol 5 to 14 F (1 to 6 C) (no condensation) 14 W Note 1) 32 Heating capacity 4 W Note 1) 77 W Note 1) Temperature stability Note 2) Pump capacity Tank capacity Port size Wetted parts material Temperature range Pressure range Required flow rate Note 3) Port size Wetted parts material Power supply Overcurrent protector ±.18 to.54 F (±.1 to.3 C) Refer to performance chart. Approx..32 gal (1.2 L) IN/OUT: Rc3/8 Drain: Rc1/4 (with plug) PPE, PP glass 1%, Alumina ceramics, Carbon, EPDM, Stainless steel 33, Stainless steel 34, PE, PP, NBR 5 to 95 F (1 to 35 C) (no condensation) Within 145 psi (1 MPa).8 to 1.9 gpm (3 to 7 L/min) IN/OUT: Rc3/8 Stainless steel 34 Single-phase 1 to 24 VAC ±1%, 5/6 Hz 1 A Current consumption 3.5 A (1 VAC) to 1.5 A (24 VAC) 5.5 A (1 VAC) to 2.5 A (24 VAC) Alarm Refer to alarm function. Communications RS-485 RS-232C RS-485 RS-232C Weight Approx. 26.5 lbs (12 kg) Approx. 28.7 lbs (13 kg) Accessories Safety standards Power cable, Foot for fixing, Splashproof cover CE marking, UL (NRTL) standards, SEMI Note 1) /Clear water conditions: set temperature 68 F (2 C), Flow rate 1.3 gpm (5 L/min)., Facility water temperature 68 F (2 C), Flow rate 1.3 gpm (5 L/min)., Ambient temperature 77 F (25 C) Note 2) The indicated values are with a stable load without turbulence in the operating conditions. It may be out of this range in some other operating conditions. Note 3) The flow rate over or below the set range may deteriorate performance or generate noise. system Facility water system Electrical system 146

Peltier-Type Chiller Thermo-con (Water-cooled) Series -W How to Order 6 W, 12 W 12 W 2 B Cooling capacity 6 6 W 12 12 W Radiating method W Water-cooled Power supply 2 2 to 22 VAC Option Nil None N NPT thread The option should be specified when ordering. Communication A RS-485 B RS-232C Select B when communication is not used. Specifications (For details, please consult our Product Specifications information.) HRG HRS HRZ FC-3283) Note 3) Model 6-W2A 6-W2B 12-W2A 12-W2B Cooling method Radiating method Control method Ambient temperature/humidity Note 1) Operating temperature range Cooling capacity Thermoelectric device (Thermo-module) Water-cooled Cooling/Heating automatic shift PID control 5 to 95 F (1 to 35 C), 35 to 8%RH (no condensation) Clear water, Fluorinated fluid (Fluorinert FC-3283, GALDEN HT135) 5 to 14 F (1 to 6 C) (no condensation) 6 W (Clear water), 4 W (Fluorinert FC-3283) Note 2) 12 W (Clear water), 8 W (Fluorinert Heating capacity 9 W (Clear water), 6 W (Fluorinert FC-3283) Note 2) 22 W (Clear water), 15 W (Fluorinert FC-3283) Note 3) Temperature stability Note 4) Pump capacity ±.18 to.54 F (±.1 to.3 C) Refer to performance chart. Tank capacity Approx..8 gal (3 L) Approx. 1.3 gal (5 L) system Port size Wetted parts material Temperature range 5 to 95 F (1 to 35 C) (no condensation) Pressure range Within 145 psi (1 MPa) Note 5) Required flow rate 2.1 to 2.6 gpm(8 to 1 L/min) 2.6 to 4. gpm (1 to 15 L/min) Port size IN/OUT: Rc3/8 IN/OUT: Rc1/2 Wetted parts material Stainless steel 33, Stainless steel 34 Power supply Single-phase 2 to 22 VAC ±1%, 5/6 Hz Overcurrent protector 1 A 15 A Current consumption 5 A 1 A Alarm Refer to alarm function. Communications RS-485 RS-232C RS-485 RS-232C Weight Approx. 55 lbs (25 kg) (including foot for fixing) Approx. 88 lbs (4 kg) (including foot for fixing) Accessories Power cable, Foot for fixing Safety standards CE marking Note 1) Fluorinert is a trademark of 3M and GALDEN is a registered trademark of Solvay Solexis, Inc. Regarding the fluid other than the above, please consult with SMC. Note 2) Conditions: Set temperature 77 F (25 C), Facility water temperature 68 F (2 C), Facility water flow rate 2.1 gpm (8 L/min), Ambient temperature 77 F (25 C). Note 3) Conditions: Set temperature 77 F (25 C), Facility water temperature 68 F (2 C), Facility water flow rate 2.6 gpm (1 L/min), Ambient temperature 77 F (25 C). Note 4) The indicated values are with a stable load without turbulence in the operating conditions. It may be out of this range in some other operating conditions. Note 5) The flow rate over or below the set range may deteriorate performance or generate noise. Facility water system Electrical system IN/OUT: Rc3/8 Drain: Rc1/4 (with plug) Stainless steel 33, Stainless steel 34, EPDM, Ceramics, PPS glass 3%, Carbon, PE, Polyurethane IN/OUT: Rc3/4 Drain: Rc1/4 (with plug) Stainless steel 33, Stainless steel 34, EPDM, Ceramics, PP, PE, Polyurethane, SiC, PPS HRZD HRW HEB HED Technical Data Related Products 147

Series -W Cooling Capacity 1 Cooling capacity (W) 6 : Clear water 5 7 9 11 13 15 F 5 Facility 5 F (1 C) water: 4 68 F (2 C) 3 2 86 F (3 C) 1 Facility water flow rate: 1.3 gpm (5 L/min) 1 2 3 4 5 6 7 temperature ( C) 3 1 : Clear water 5 7 9 11 13 15 F Cooling capacity (W) The values shown on the performance chart are not guaranteed, but typical. Allow margins for safety when selecting the model. 6 5 4 3 2 1 1 : 2% ethylene glycol 5 7 9 11 13 15 F 68 F (2 C) Facility water flow rate: 1.3 gpm (5 L/min) 1 2 3 4 5 6 7 temperature ( C) : 2% ethylene glycol 5 7 9 11 13 15 F Cooling capacity (W) 8 6 4 2 6 5 F (1 C) Facility water: 68 F (2 C) 86 F (3 C) Facility water flow rate: 1.3 gpm (5 L/min) 1 2 3 4 5 6 7 temperature ( C) : Clear water Cooling capacity (W) 8 6 68 F (2 C) 4 2 Facility water flow rate: 1.3 gpm (5 L/min) 1 2 3 4 5 6 7 temperature ( C) : FC-3283 15 5 7 9 11 13 15 F 15 5 7 9 11 13 15 F Cooling capacity (W) 1 5 5 F (1 C) Facility water: 68 F (2 C) 95 F (35 C) Cooling capacity (W) 1 5 5 F (1 C) Facility water: 68 F (2 C) 95 F (35 C) 12 Cooling capacity (W) 148 3 25 2 15 1 Facility water flow rate: 2.1 gpm (8 L/min) 1 2 3 4 5 6 7 temperature ( C) 5 5 7 9 11 13 15 F Facility 5 F (1 C) water: 68 F (2 C) 95 F (35 C) temperature ( C) : Clear water Facility water flow rate: 2.6 gpm (1 L/min) 1 2 3 4 5 6 7 Cooling capacity (W) 3 25 2 15 1 Facility water flow rate: 2.1 gpm (8 L/min) 1 2 3 4 5 6 7 temperature ( C) : FC-3283 5 7 9 11 13 15 F 5 F (1 C) Facility water: 68 F (2 C) 95 F (35 C) 5 Facility water flow rate: 2.6 gpm (1 L/min) 1 2 3 4 5 6 7 temperature ( C)

Heating Capacity 1 Heating capacity (W) 6 5 4 3 2 The values shown on the performance chart are not guaranteed, but typical. Allow margins for safety when selecting the model. : Clear water 5 7 9 11 13 15 F 5 7 9 11 13 15 F 6 Facility water flow rate: 13. gpm (5 L/min) Facility water flow rate: 1.3 gpm (5 L/min) 1 5 F (1 C) 1 2 3 4 5 6 7 temperature ( C) 3 1 86 F (3 C) 68 F (2 C) : Clear water 5 7 9 11 13 15 F Facility water flow rate: 1.3 gpm (5 L/min) Peltier-Type Chiller Thermo-con (Water-cooled) Heating capacity (W) 5 4 3 2 1 1 Series -W : 2% ethylene glycol 68 F (2 C) 1 2 3 4 5 6 7 temperature ( C) : 2% ethylene glycol 5 7 9 11 13 15 F Facility water flow rate: 1.3 gpm (5 L/min) HRG HRS Heating capacity (W) 8 6 4 2 86 F (3 C) 68 F (2 C) 5 F (1 C) Heating capacity (W) 8 6 4 2 68 F (2 C) HRZ HRZD 6 1 2 3 4 5 6 7 temperature ( C) : Clear water 1 2 3 4 5 6 7 temperature ( C) : FC-3283 HRW 15 5 7 9 11 13 15 F Facility water flow rate: 2.1 gpm (8 L/min) 15 5 7 9 11 13 15 F Facility water flow rate: 2.1 gpm (8 L/min) Heating capacity (W) 12 Heating capacity (W) 1 5 35 3 25 2 15 1 temperature ( C) 95 F (35 C) 68 F (2 C) 5 F (1 C) 1 2 3 4 5 6 7 : Clear water 5 7 9 11 13 15 F 5 7 9 11 13 15 F 3 Facility water flow rate: 2.6 gpm (1 L/min) Facility water flow rate: 2.6 gpm (1 L/min) 95 F (35 C) 68 F (2 C) 5 5 F (1 C) 1 2 3 4 5 6 7 temperature ( C) Heating capacity (W) Heating capacity (W) 1 5 25 2 15 1 68 F (2 C) 5 F (1 C) 1 2 3 4 5 6 7 5 temperature ( C) 5 F (1 C) temperature ( C) 95 F (35 C) : FC-3283 95 F (35 C) 68 F (2 C) 1 2 3 4 5 6 7 HEB HED Technical Data Related Products 149

Series -W Pump Capacity (Thermo-con Outlet) 1/3 Since a DC pump is used, the unit is not affected by power requirements..15 MPa 2 psi.5 1 1.5 2 2.5 3 gpm Discharge pressure 15.1 1.5 5 2% ethylene glycol Water. 2 4 6 8 1 12 flow rate (L/min) 6 Since a DC pump is used, the unit is not affected by power requirements..15 MPa.5 1 1.5 2 2.5 3 gpm 2 psi Discharge pressure Water Fluorinert FC-3283. 2 4 6 8 1 12 flow rate (L/min) Pressure Loss in Facility Water Circuit 1.14 MPa.5 1 1.5 2 2.5 3 3.5 gpm 2 psi.12 1.7.1 1.5.8 1.2.6.9.4.6.2.3. 5 1 15 Facility water flow rate (L/min) Pressure loss 6.25 MPa 3.5 psi Pressure loss 15 15.1 1.5 5.2 3..15 2.1 1.5.5.7.5 1 1.5 2 2.5 3 3.5 gpm. 5 1 15 Facility water flow rate (L/min) 12.3 MPa 4 psi Discharge pressure.25 35.2 3 6Hz.15 2 Fluorinert FC-3283 5Hz.1 15.5 5 Water 6Hz 5Hz. 5 1 15 2 25 3 flow rate (L/min) 3.25 MPa 3.5 psi Pressure loss 12.6 MPa 9. psi Pressure loss.2 3..15 1 2 3 4 5 6 7 gpm.5 1 1.5 2 2.5 3 3.5 gpm.1 1.5.5.7. 5 1 15 Facility water flow rate (L/min).5 1 1.5 2 2.5 3 3.5 gpm.5 7..4 6..3 4..2 3..1 1.5. 5 1 15 2 Facility water flow rate (L/min)

Peltier-Type Chiller Thermo-con (Water-cooled) Series -W Parts Description 1/3 Display/Operation panel Tank lid (with O-ring) Facility water outlet Facility water inlet Handle inlet level gauge External temperature sensor connector Alarm output connector Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. HRG Power switch outlet Drain ( drain port) Power connector (Connect the attached power cable.) Splashproof cover HRS HRZ 6/12 HRZD Power switch Display/Operation panel Tank lid (with gasket) level gauge Handle Facility water outlet Facility water inlet Splashproof cover outlet inlet Drain ( drain port) Cooling fan Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Alarm output connector External temperature sensor connector Power connector (Connect the attached power cable.) HED HEB HRW Related Products Technical Data 151

Series -W Dimensions 1-W5 3-W5 Unit: Inch (mm) Warning/Caution label 7.2 (182) (1.26(32)) 4.7 (12) Tank lid (with O-ring) (1.7 (45.5)) (2.2 (55)).4 (1) 13.7 (348) Foot (Accessory).16 (4) x width.2 (5) Display/ Operation panel Power switch (7.5 (19)) 7.2 (184) 1. ((25)) ø2.8 (72) Power Cable (Accessory) level gauge 9.6 (245) 7.8 (197) 8.4 (214) 12.6 (321) Handle 3.9 (1) (1.1 (27)) (.51 (13)) (1.2 (3)) 1.2 (3) 14.5 (368) 1.6 (41) Circulating fluid inlet Rc3/8 8.7 (221) 6.3 (16) 5.6 (143) 1.1 (28) Drain ( drain port) Splashproof cover (Accessory) For NPT thread specification (-N), all fittings (including those at the circulating fluid drain port) are made of NPT..8 (19) DRAIN 1.1 (28) 2.5 (64) 3.3 (84) 4.1 (14) IN OUT IN RADIATING WATER RECIRCULATING WATER OUT 5.8 (148) EXT.SENSOR ALARM RS-232C AC Model no. label 5.9 (15) 5. (128) 3.2 (82) 1.5 (37) Facility water outlet Rc3/8 Facility water inlet Rc3/8 outlet Rc3/8 External temperature sensor connector Alarm output connector Power connector Communication connector Connector: IEC 632 C13 or equivalent Cable: 14AWG, O.D. ø8.4 Wire color Contents Black 1 to 24 VAC Black 1 to 24 VAC Green/Yellow PE 78.7 (2) Power cable (Accessory) 152

Peltier-Type Chiller Thermo-con (Water-cooled) Series -W Dimensions 6-W2 Unit: inch (mm) Foot (Accessory) Power switch 17.9 (455).5 (13) 8.4 (214) (.5 (13)).16 x.28 (4 x 7) 17. (433) 18. (458) Display/ Operation panel 9.5 (24) 9.7 (246) Foot (Accessory) Warning/Caution label HRG HRS HRZ H L level gauge Tank lid with gasket 19. (482) Handle 1.6 (4) Air 15. (382) 15.4 (39) Facility water outlet Rc3/8 13.3 (339) Circulating fluid outlet Rc3/8 Circulating fluid inlet 8.1 (27) Rc3/8 5.8 (146.5) Model no. label 1.1 (28.5) drain port Rc1/4 (with plug) RECIRCULATING FLUID DRAIN 8. (24) 6.6 (168) 5. (128) OUT RADIATING WATER OUT IN IN 5.2 (133) 5.8 (148) Facility water inlet Rc3/8 2. (5) RS-232C ALARM EXT.SENSOR AC 1.3 (32) Fan 3.1 (8) Communication connector 11.9 (33) Alarm output connector 7.8 (198) 6.6 (168) External temperature 5. (128) sensor connector 2.9 (73) Power connector HEB HRW HRZD For NPT thread specification (-N), all fittings (including those at the circulating fluid drain port) are made of NPT. HED Power Cable Connector: IEC 632 C13 or equivalent Cable: 14AWG, O.D. ø8.4 Wire color Contents Black 2 to 22 VAC Black 2 to 22 VAC Green/Yellow PE 78.7 (2) Power cable (Accessory) Technical Data Related Products 153

Series -W Dimensions 12-W2 Unit: Inch (mm) Foot (Accessory) Power switch 2.6 (523) 19.7 (51) 7.5 (19) 11.8 (3) 12. (36) 2.2 (55) (2.2 (55)).16 x.28 (4 x 7) 2.7 (526) Display/ Operation panel Foot (Accessory) Warning/Caution label level gauge Tank lid with gasket Handle 1.6 (4) Facility water outlet Rc1/2 9.8 (248) 8.2 (28) 5.8 (148) outlet Rc3/4 2. (5) H L Air 17.3 (44) 17.6 (448) 15.9 (44) 12.8 (326) 11. (281) Facility water inlet Rc1/2 6.5 (165) 1.1 (28.5) DRAIN OUT RADIATING WATER IN OUT RECIRCULATING FLUID IN RS-232C ALARM EXT.SENSOR AC Fan 3.1 (8.) 14.2 (361) 7.8 (198) 6.6 (168) 5. (128) 2.6 (67) Communication connector Alarm output connector External temperature sensor connector Power connector 21.7 (55) drain port Rc1/4 (with plug) 1.9 (277) Model no. label 5.2 (131) 1.6 (4) inlet Rc3/4 For NPT fitting specification (-N), all fittings (including those at the circulating fluid drain port) are made of NPT. Power Cable Connector: DDK CE5-6A18-1SD-D-BSS or equivalent Cable: 14AWG, O.D. ø8.4 Wire color Black Black Green/Yellow Contents 2 to 22 VAC 2 to 22 VAC PE 78.7 (2) Power cable (Accessory) 154

Peltier-Type Chiller Thermo-con (Water-cooled) Series -W Connectors 6-W2/1-W5/3-W5 1. Power connector (AC) IEC 632 C14 or equivalent 6-W2 1-W5 3-W5 3 Pin No. 1 2 3 Contents 2 to 22 VAC 2 to 22 VAC PE Pin No. 1 2 3 Contents 1 to 24 VAC 1 to 24 VAC PE 1 2 2. Communication connector (RS-232C or RS-485) D-sub 9 pin (socket) Holding screw: M2.6 HRG Pin No. 1 2 3 4 5 6-9 Signal contents RS-232C RS-485 Unused BUS+ RD BUS SD Unused Unused Unused SG SG Unused Unused 3 2 5 4 1 9 8 7 6 HRS HRZ 3. External sensor connector (EXT.SENSOR) D-sub 15 pin (socket) Holding screw: M2.6 Pin No. 1-2 3 4 5 6-14 15 Signal contents Unused Terminal A of resistance temperature detector Terminal B of resistance temperature detector Terminal B of resistance temperature detector Unused FG 8 15 5 4 6 3 7 2 1 14 13 12 11 1 9 HRZD HRW 4. Alarm output connector (ALARM) D-sub 9 pin (pin) Holding screw: M2.6 Pin No. 1 2 3 4-5 6 7 8 9 Signal contents Contact a for output cut-off alarm (open when alarm occurs) 3 4 Common for output cut-off alarm 1 2 5 Contact b for output cut-off alarm (closed when alarm occurs) Unused Contact a for upper/lower temp. limit alarm (open when alarm occurs) Common for upper/lower temp. limit alarm Contact b for upper/lower temp. limit alarm (closed when alarm occurs) Unused 6 7 8 9 HEB HED 12-W2 Power connector (AC) DDK CE5-2A18-1PD-D or equivalent Technical Data Pin No. A B C D Contents 2 to 22 VAC 2 to 22 VAC Unused PE D C A B Related Products Other connectors are the same as those for the 6-W2. 155