SCHEDULE ONE TO CUSTOMER CONTRACT DOCUMENT STANDARD INSTALLATION CONDITIONS FUEL CONVERSION PRODUCT COMBINATIONS BREAKDOWN HOT WATER REPLACEMENT

Similar documents
CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT

Developer, new connection and infrastructure charges

Developer, new connection and infrastructure charges. 1 April 2015 to 31 March 2016

Security Alarm Monitoring Agreement

about your house Before You Start an Energy-Efficient Retrofit Mechanical Systems

CONTRACTOR GUIDELINES

Preparing. Your connection checklist. for the nbn Fixed Wireless network. For help and support. Installation approval

Your connection checklist

Schedule of Standard Charges for Distribution Services and Third Party Damage

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

Installer s Guide IMPORTANT INFORMATION Read This Document First On completion, sign and leave with owner

Design and siting guidelines

Operation / Installation Manual

SECTION 13 LANDSCAPING & TREE PROTECTION

AUTOMATIC FIRE ALARM MONITORING

A guide to landlords duties: Gas Safety (Installation and Use) Regulations What type of property is covered?

WARRANTY BOOKLET. Commercial Hot Water. Register online at

2018 Price List & Haus Care Service Guide

Schedule of Standard Charges for Distribution Services and Third Party Damage

USING YOUR PRESSURE SEWER SYSTEM

Repairs and Maintenance Service Standards

HIGH VOLTAGE ELECTRICAL SUPPLY CONNECTIONS Overview of High Voltage Customer Obligations

Distributed Generation (greater than 10kW) Connecting to Vector s electricity network

Hot Water South East Queensland

Owner s Guide and Installation Instructions

Alarm Signalling Equipment: Connection Requirements (Victoria) TAN 06. Technical Advisory Note. Version 1 October 2018

OWNER & INSTALLER MANUAL AND WARRANTY INFORMATION.

Network efficiency and fire services

FTTN Business Readiness Testing Special Terms

- CONSTRUCTION FIRE SAFETY STANDARDS

Consumer unit replacement in domestic and similar premises

Annex 4a Common Minimum Technical Competency Requirements for Oil Appliance Installation Work (Domestic)

OWNER S MANUAL WARRANTY INFORMATION AND INSTALLATION INSTRUCTIONS PROFLO AND MARATHON ELECTRIC STORAGE WATER HEATERS

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

Owner s Guide and Installation Instructions

ESB Networks Connection Charges. Response and Decision Paper

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

3.2 If there is an inconsistency between the documents forming the CSA, specific requirements will prevail over general requirements.

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Installation/Operating Instructions. MODELS Bosch 17e Bosch 21e Bosch 25e Bosch 26e INSTALLATION MANUAL

City of Regina Alarm Bylaw

1 NBN Co Limited (ABN ) of Level 11, 100 Arthur Street, North Sydney NSW 2060 (NBN Co)

Evacuated Tube Solar Hot Water System. Owners Manual. Version 5.4

Title: Room-sealed fanned draught flue systems concealed within voids

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

IMAS nd Edition Director, United Nations Mine Action Service (UNMAS), DC2 0650, United Nations, New York, NY 10017, USA

The Gas Safety (Installations and Use) Regulations 1998.

HHIC consumer guide to gas boiler servicing

CRAFTSMAN EXAMINATION, NOVEMBER 2009 GASFITTING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Landscape Act. (Act No. 110 of June 18, 2004)

4. Reason for making this application for Trade Waste Agreement of consent (tick appropriate) Date:

USERS MANUAL FOR GAS BOILERS

University of Delaware

GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32

CENTRA-COIL QUALITY HOT WATER SERVICE

Grand Avenue Primary and Nursery School. Policy for Fire Safety. Contents. 6. Prevention of fire Events taking place outside school hours

STRESS-FREE RENOVATIONS By Nick Brownlee, Managing Director Procuro Building and Renovation

FIRE SAFETY RISK ASSESSMENT

Owner s Guide and Installation Instructions

CLYST ST. MARY VILLAGE HALL

Gas Emergency Response

Starting a Food Garden

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Request For Quotations. For The. Fire Sprinkler Retrofit Program For Licensed Small Or Rural Retirement Homes. October 11, 2017

LAND USE ASSESSMENT REPORT (LUAR) PROPOSED AFFORDABLE HOUSING COMPLEX MAIN ROAD PDE FILE NUMBER: REZ

PRESSURE SEWER SYSTEMS GUIDE FOR HOME OWNERS AND BUILDERS

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Miele home delivery and installation service

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

EVERLAST - SERIES 2000

Fire alarm provisions for alerting the Fire Service

HomeCare Range Terms and Conditions. In your world everything should be clear

Fire resistance test on fire collars protecting a concrete slab penetrated by services

ISO INTERNATIONAL STANDARD. Safety requirements for industrial laundry machinery Part 1: Common requirements

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

Mr & Mrs Connolly per Pump House Designs Pump House Yard The Green SEDLESCOMBE, East Sussex. TN33 0QA

PLANNING COMMITTEE REPORT

DSO Compliance Report 2009

SaskPower Gas Inspections Schedule of Fees

AGREEMENT FOR THE PROVISION OF FIRE ALARM MONITORING SERVICES AND EQUIPMENT

Hot Water New South Wales

CONTRACT FOR HIRE OF THE COMMUNITY CENTRE CONDITIONS OF HIRE

Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation

Environmental Planning and Assessment Amendment (Smoke Alarms) Regulation 2006

Plan Change 56: Fire Fighting Water Supplies Code of Practice

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

DESIGN OF FOOTBRIDGES

NZQA unit standard version 1 Page 1 of 6. Install, maintain and repair of telecommunications optical fibre network infrastructure

Owner s Guide and Installation Instructions Electric Domestic Water Heater

Facing Point Lock and Detection Testing

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Electrical Safety Policy

Stephen Merrylees Fiona Merrylees John Guica Melbourne Senior Member E. Riegler Hearing

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Our Customer Terms Page 1 of 13 Voice Grade Dedicated Lines section

PLEASE NOTE! This plan must include: setback dimensions, gas meter location, any obstructions, well and septic

Owners Guide and Installation Instructions Commercial Air Sourced Heat Pump Water Heater

High Speed Rail (London- West Midlands)

Transcription:

1. Type of Installation SCHEDULE ONE TO CUSTOMER CONTRACT DOCUMENT STANDARD INSTALLATION CONDITIONS FUEL CONVERSION PRODUCT COMBINATIONS BREAKDOWN HOT WATER REPLACEMENT 1.1 These Standard Installation Conditions apply where the Installation comprises the replacement of: an existing electric external storage hot water unit with a natural gas external storage unit in the same location, using existing valves; (f) (g) an existing electric external gas storage hot water unit with a natural gas continuous flow external unit in the same location using existing valves (must be of same megajoule size); or an existing electric external storage hot water unit with a heatpump in the same location, using existing valves. an existing electric hot water with a LPG storage unit in the same location when a LPG tank is available onsite an existing electric hot water with a LPG storage unit in the same location when a LPG tank is required onsite an existing electric hot water with a LPG continuous flow unit in the same location when a LPG tank is available onsite an existing electric hot water with a LPG continuous flow unit in the same location when a LPG tank is required onsite 2. Pre-Installation Site Inspection 2.1 The Installation Subcontractor may conduct a pre-installation site inspection at the Premises. If a pre-installation site inspection is not undertaken prior to the day arranged for Installation, a pre-installation site inspection will be undertaken on the day arranged for Installation. 3. Time for Installation 3.1 Origin (or the Installation Subcontractor) will contact you to arrange a suitable time for Installation of the System (and for any pre-installation site inspection undertaken prior to the time arranged for Installation). You must be present during the arranged time for the Installation (and during any pre-installation site inspection). 4. Installation Package 4.1 Subject to clause 6 of this Schedule, the Installation comprises the installation of the System at the Premises, in accordance with the manufacturers guidelines, relevant Australian standards and laws, as described in these Standard Installation Conditions. 5. Included Services and Items

5.1 Subject to clause 6 of this Schedule, the services and items included within the Installation are as follows: the removal and disposal of your existing external hot water system/tank; (f) (g) (h) the installation of the System in the same location as your existing external system/tank; the electrical work necessary for the disconnection of your existing system/tank and the installation of the System; testing and commissioning of the System in accordance with clause 8 of this Schedule; the provision of a plumbing compliance certificate and a certificate of electrical safety (or equivalent), in accordance with clause 9 of this Schedule, where required; and cleaning up any mess created by the Installation Subcontractor (including the removal of rubbish brought onto the Premises by the Installation Subcontractor). where applicable LPG installation s will include engraving of the LPG code to keep a record of the LPG load. 5.2 Where the System is an external natural gas storage hot water system replacing an external electric hot water system, the Installation will also include: the connection of the System to a gas line in the same external location with an allowance of up to 5 meters of 25mm copper pipe; supply and installation of a gas cock; filling the storage tank with water and purging air from the System; and replacement of the concrete slab, where required. 5.3 Where the System is an external natural gas continuous flow hot water system replacing an external electric hot water system, the Installation will also include: the connection of the System to a gas line in the same external location with an allowance of up to 5 meters of 25mm copper pipe; supply and installation of a gas cock; the reconnection of power (includes the installation of a new outdoor power point within 3 meters of new location of unit (if required)). 5.4 Where the System is an external heatpump hot water system replacing an external electric hot water system, the installation will also include: the connection of a heat pump to a pre-existing power supply on peak tariff only (Tariff 33 for QLD customers) with an allowance of up to 3m electrical cable; fill heatpump with water and purge air from the system; the reconnection of power (includes the installation of a new outdoor power point within 3 meters of new location of unit (if required)); the connection of a tempering valve where required (set to supply water at 50 C); and the connection of a Duo Valve and a non isolating return valve if required.

5.5 Where the System is an external LPG storage hot water system replacing an external electric hot water system with a LPG tank available onsite, the installation will also include: the connection of the system to the LPG gas line, including pig tails and an allowance of 5 supply and installation of gas cock; 5.6 Where the System is an external LPG storage hot water system replacing an external electric hot water system with a LPG tank required onsite, the installation will also include: the connection of the system to the LPG gas line, including pig tails and an allowance of 5 supply and installation of hot, cold and a gas cock; supply and installation of gas regulator; 5.7 Where the System is an external LPG continuous flow hot water system replacing an external electric hot water system with a LPG tank available onsite, the installation will also include: the connection of the system to the LPG gas line, including pig tails and an allowance of 5 supply and installation of gas cock; the reconnection of power (includes the installation of a new outdoor power point within 3 meters of new location of unit (if required)). 5.8 Where the System is an external LPG continuous flow hot water system replacing an external electric hot water system with a LPG tank required onsite, the installation will also include: the connection of the system to the LPG gas line, including pig tails and an allowance of 5 supply and installation of hot, cold and a gas cock; supply and installation of gas regulator; the reconnection of power (includes the installation of a new outdoor power point within 3 meters of new location of unit (if required)).

6. Excluded Services and items 6.1 The Installation does not include the following services or items: any work involved in relocating an internal unit to an external location; (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r) (s) (t) (u) (v) (w) the supply or installation of any new electricity power point, if required; (if the installation is Natural Gas system) any work necessary to ensure the existing gas supply is adequate; any upgrade or extension required to any existing gas line beyond outlined allowances; any repair required to leaks in any existing gas line; trenching and excavation work; the installation of internal remote temperature controllers (which are available with Endurance continuous flow hot water units); the relocation of electrical cable beyond outlined allowances; the installation of tempering valves for all products except Heatpumps; the replacement of isolating water valves or gas cocks beyond outlined allowances; the replacement of duo valves; (if the Installation is a Continuous Flow system) the installation of a flue diverter; installation on premises other than single-storey or double-storey residential premises; installation on homes under construction; the provision of special equipment where required to install the System (such as cranes, scaffolding, boom lifts or cherry pickers); any work required to gain safe, convenient and unhindered access (such as the temporary removal of fencing or clearance of vegetation); any other work required where safe, convenient and unhindered access for the Installation is not provided; any work required to reinstate or make good any walls, plaster or other items that are altered or damaged during the Installation; the removal of asbestos or the costs of an investigation to determine whether asbestos is present; the supply or installation of any residual current device (required where the Premises power circuits are not protected by a residual current device); the rectification of any inadequate existing electrical supply or, where relevant, existing gas supply; any other work that is required, prior to the Installation, to ensure that the Premises comply with any electrical or other standards required by law; any other work, required prior to the Installation, to ensure that the Premises are suitable and safe for the Installation;

(x) (y) the provision of approvals, consents or permits from any person (including, but without limitation, any approval, consent or permit which you are required to obtain from any local council/planning authority, any strata corporation or body corporate, or the owner of the Premises, under clause 11 of this Schedule); any work at remote locations (such as islands remote from the mainland); (z) any work that is not described, or necessarily implied, in clause 5. Neither Origin nor the Installation Subcontractor will have any obligation to carry out any of the work that is excluded from the Installation (unless Origin (or the Installation Subcontractor) agrees that the Installation Subcontractor will carry out that work). 7. Additional Services and/or items 7.1 Prior to Installation of the System, Origin (or the Installation Subcontractor) will advise you of any additional services and/ or items that are not included in the Installation but which are required to complete the Installation. You will receive this advice during the pre- Installation site inspection or on the day of Installation. 7.2 When you are advised of the additional services and/or items that are not included in the Installation but which are required to complete the Installation, Origin (or the Installation Subcontractor) may give you a quote for the cost of those additional services and/or items. Schedule two sets out standard or recommended charges for some additional services and/or items. 7.3 Once you have received the quote from Origin (or the Installation Subcontractor), you may elect to: enter into an agreement with the Installation Subcontractor for the supply of the additional services and/or items; or arrange for another party to supply the additional services and/or items, prior to Installation; or not proceed with the Installation. 7.4 If you elect to not proceed with the Installation, this Contract will terminate at that time and, in that event, Origin will provide you with a full refund by cheque. 7.5 The Installation will not proceed until the additional services and/or items are supplied. If necessary, this may require the Installation Subcontractor to re-schedule the time for Installation with you. 7.6 If you would like the Installation Subcontractor (or another person) to the supply of the additional services and/or items, you will need to enter into a separate contract with the Installation Subcontractor (or the other person). Any contract you make is not a contract between you and Origin and does not vary your contract with Origin. 8. Testing and Commissioning 8.1 After installation of the System, Origin (or the Installation Subcontractor) will test and commission the System to confirm that the System has been installed in compliance with the manufacturer s specifications and is fully operational. 9. Plumbing Compliance Certificate and Certificate of Electrical Safety 9.1 On satisfactory completion of the Installation, Origin (or the Installation Subcontractor) will provide a plumbing compliance certificate and a certificate of electrical safety (or

equivalent), where required, which certifies that the System has been installed in accordance with the requirements of relevant Australian Standards and laws. 10. Compliance with Electrical Standards 10.1 You must ensure that the Premises comply with electricity standards imposed by law prior to Installation. 10.2 If the Premises do not comply with electricity standards imposed by law, you must arrange (at your cost) for a qualified electrician to rectify the fault(s). The type of works that an electrician may need to carry out may include, but is not limited to, the following: rectifying an inadequate existing electrical supply; installing a safety switch; upgrading a switchboard; upgrading of metre panel board; works to the metre box where the metre box is non-compliant. 11. Pre-Installation Approvals 11.1 Prior to Installation, you are required to obtain all relevant approvals, consents, and permits from your local council/planning authority and, if applicable, your strata corporation or body corporate. If you do not own the Premises, you must also ensure that you get written permission from the owner. You must provide this authority to Origin as soon as possible, by posting it to: 12. Access Origin Solar Customer Administration GPO Box 186c Melbourne VIC 3001 12.1 You must ensure that Origin and the Installation Subcontractor (together with any vehicle and equipment) have safe, convenient and unhindered access for the purposes of undertaking the installation. 12.2 If you think that access may be an issue, please inform Origin (or the Installation Subcontractor) when you are contacted to arrange the Installation.