Bosch EVAX System - High-rise Applications

Similar documents
UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

FCS-320-TM Series Conventional Aspirating Smoke Detectors

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

E3 Series Broadband System

July 14, 1999 DF C-100.

FCP 320/FCH 320 Conventional Automatic Fire Detectors

FireFinder XLSV Digital Emergency Voice Alarm / Communication System

Fireray 2000 Linear Smoke Detector

LB3-PCx50 Premium Cabinet Loudspeakers

ECC-50/100(E) Emergency Command Center

E3 Series Broadband System

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

ECC-50/100C. Emergency Command Center

June 10, 2002 DF C S2424

DS7465i. Installation Instructions. Input/Output Module

Battery charger modules

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

Multiplex Eight Input Remote Modules

DESCRIPTION INSTALLATION

DS7400Xi Addressable Control/ Communicator

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

F220-B6PS/M. Installation Guide. Addressable Detector Bases

SAFEPATH Mass Notification System (SPMNS)

GEC Low-frequency Horn Strobes

Easy Series Voice Modules

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

SP40S-D. Kingfisher Company, inc. Features: Description:

D7053. Installation Instructions Multiplex Input/Output Module

16 Zone Voice Evacuation VA & PA Sound System

FireNET Plus Wiring Instructions

SIGA-CC1 Single Input Signal Module Installation Sheet

Addressable NAC Output Module D327A

Remote NAC Power Supply D7038

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

TECHNICAL DATA OBSOLETE

D7052. Installation Instructions Multiplex Dual Input Module

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Autonomous control unit

SAFEPATH DoD facility communications system & expansion options

D7044. Installation Instructions Multiplex Single Input Module

Vocia VACIE. Reference Guide

VACIE REFERENCE GUIDE REVISION 1.2.6

Bosch Plena Public Address and Voice Alarm System The fast route to safety

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

FMR Installation Instructions. Addressable Fire System Controller

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

Easy Series Intrusion Control Panel

D720 and D1255 Command Centers

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

EMERGENCY COMMUNICATIONS SYSTEMS SUPPLEMENTARY RECORD OF INSPECTION AND TESTING

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

System Sensor L-series indoor horn/ strobes

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

D7024 Fire Alarm Control Panel

Print Specification. Publication. Instructions. Specific requirements. General requirements

Addressable Fire Alarm Control Panel

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Call stations and extensions

Duct smoke housings, 4-wire D341/D341P and D342/D342P

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

TrueAlarm Fire Alarm Controls

Unity DAU Voice Alarm System

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

TrueAlert Addressable Notification Appliances

30.45 Electric Release PDRP-2001

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

MIC-WKT and MIC-WKT-IR Installation Manual

FPA 5000 With Functional Modules

Bionics Instrument. Alarm Handling. Gas Alarm Systems

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Notification Appliance Circuit Module

TrueAlert Addressable Notification

SAFEPATH SAFEPATH. Emergency communications system

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Building Technologies

D250A/D253/D261AW/D280A/D290 Series

PRODUCT CATALOG. Concord Family Product Catalog. December 1999

Commercial and Light Industrial Fire Alarm Control Panel

by Honeywell VOICE ALARM SOLUTIONS BROCHURE

B440 Conettix Plug-in Cellular Communicator

ANC BBX-FXMNS or BBX Audio Network Controller Board Installation Instructions TNC-5000 ANC Module Mounting Locations

SC-6 Six Supervised Control Module

EQUIPMENT SPECIFICATION. GAI-TRONICS ADDRESSABLE AMPLIFIED SPEAKER and AUDIO MESSENGER INTERFACE PRODUCTS

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Bosch Plena Public Address and Voice Alarm System The ease of amplification

N-8000 SERIES IP INTERCOM SYSTEM

Transcription:

Fire Alarm Systems Bosch EVAX System - High-rise Applications Bosch EVAX System - High-rise Applications Master panel with capability for multiple distributed panels Operates as stand alone or connected to an FACP Network transmission over fiber optic or copper pair cable Digitized live voice and prerecorded messaging Zone paging control Fan and damper control Meets area of refuge/rescue assistance communication requirements Variety of accessories available for system customization The Bosch EVAX System for high-rise applications is a networked emergency relocation and paging system with integrated two way fireman s telephone system. It operates with the Fire Alarm Control Panel (FACP) in a building to provide automatic response to life safety emergencies. While providing all necessary features for an effective voice evacuation system, it can easily convey evacuation, stay-in-place, or other public address announcements and automatic messages with multiple channels of simultaneous audio. Configure your system to include Fire Fighter Phones or Warden Stations as required, for fire fighter communications to supplement 2 way radios and for use in areas of refuge assistance so trapped individuals can communicate with fire command. Smoke control features include automatic or manual positive or negative pressurization for compartments, floors, or stairwells. The simple to use interfaces allow fire department authorities to take over controls and communicate effectively. System Overview The maximum system configuration contains up to 256 Distributed Panels providing up to 2028 monitor and control points.

2 Bosch EVAX System - High-rise Applications Distributed Panels The Distributed Panels communicate with the Master Panel through the NetCom Loop. They typically provide: Voice Evacuation Speaker Loops dedicated data and audio loops using a minimum of 18 AWG wire with end-of-line resistors (EOLR). Fire Phone Loops dedicated audio loop using a minimum of 20 AWG twisted pair wiring with an EOLR. Fan and Damper Loops data loop using a minimum 20 AWG twisted pair wiring on which up to 32 modules can be attached. Each module provides two points (one control and one monitor) for a total of 64 points on the circuit. Additionally, local Audio Amplifiers can be connected to the Distributed Panels. The Bosch Distributed Panels additional provide specific accessories to support specific functions. The HMB DP provides four audio circuits, the HMB DP/P provides four Fire Phone circuits, and the HMB DP 42 provides 16 audio circuits. Certifications and Approvals 1 Master Panel 2 NetComm Loop 3 Distributed Panels 4 Voice Evacuation Speaker Circuits 5 Fire Phone 6 Fan and Damper Control and Monitor 7 Local Audio Amplifiers (25 W, 50 W, 100 W or combinations yielding 150 W or 200 W) Functions Master Panel The Master Panel provides the high speed communication loop (NetComm Loop), master microphone control for live voice (PA) messages, dual channel Digital Message Repeater (DMR) for up to 1000 prerecorded messages, and a 16 switch control module. NetComm Loop The NetComm Loop provides high speed RS 485 communications over twisted pair, Category 5 UTP cable. The network can be wired as Style 4 or Style 7 with a maximum of 4000 ft between panels and a total loop length of 50,000 ft. The loop carries data and six audio channels. Region Certification USA UL UOXX: Control Unit Accessories, System (ANSI/UL 864) CSFM Installation/Configuration Notes Compatible Products Main Panel Accessories 6911-1446:0103 VOICE COMMUNICATION SYSTEMS CONTROL UNITS MB SLC Switch/LED Card F.01U.201.669 MB SSC Switch Scan Card F.01U.201.670 MB MFA Master Fire Phone Assembly F.01U.201.671 MB XI Extended Input Interface F.01U.201.672 MB OI Output Interface Card F.01U.201.673 Distributed Panel Accessories EVX 25E Expander Module 25 W 4.998.143.753 EVX 50E Expander Module 50 W 4.998.143.785 EVX-100E Expander Module 100 W 4.998.143.761 EVX T2885 Power transformer for EVX 25E 4.998.143.738 EVX T17528 Power transformer for EVX 50E/100E 4.998.143.739 MB MBK Mother Board Relays F.01U.201.677 MB AMI Audio Module Interface F.01U.201.678

Bosch EVAX System - High-rise Applications 3 Distributed Panel Accessories MB FPI Fire Phone Interface F.01U.201.679 MB FPO2 Fire Phone Output Adapter F.01U.201.680 MB FO Fiber Optic Interface Card F.01U.201.681 EVB BA100 Backup Audio Interface F.01U.201.682 Phone Accessories MB FJ Telephone Jack F.01U.201.683 MB FH Portable Handset F.01U.201.684 MB TC Fire Phone Cabinet F.01U.201.685 MB FS Fire Phone Station F.01U.201.686 MB WS Warden Station F.01U.201.687 Replacement Parts MB DCC Data Communication Controller F.01U.201.688 MB ASC Audio System Control F.01U.201.689 MB MMC Master Microphone Control F.01U.201.690 MB MBR Mother Board Remote F.01U.201.691 MB PWR Master Panel Power Supply F.01U.201.692 Parts Included Quant. Component 1 Master or Distributed Panel 1 Literature Installation Instructions Technical Specifications Communications Bus Communication Type: Data Rate: Frequency: Wire Type: Current: Impedance: Voltage (peak to peak): Electrical (Master Panel) RS 485 standard 1 MB 1.024 MHz Twisted pair, Category 5 UTC 50 ma maximum 120 Ω maximum between panels 5 V maximum Current Draw ASC: Alarm: 30 ma, Standby: 30 ma DCC: Alarm: 80 ma, Standby: 80 ma IOI: Alarm: 20 ma, Standby: 20 ma MMC: Alarm: 45 ma, Standby: 45 ma SLC: Alarm: 6 ma, Standby: 6 ma SSC: Alarm: 25 ma, Standby: 25 ma Current Draw Batteries 1 Type: Two 12 VDC Gel Cell in series Current (battery charging): 800 ma Current (input): Typical Load: 0.28 A Maximum Load: 0.4 A Capacity: Minimum: 24 VDC, 7 Ah Maximum: 24 VDC, 18 Ah Power Input (primary): Input current: Input (circuits): 120 VAC at 60 Hz 0.28 A at 120 VAC all circuits at 24 VDC 1 Two 7 Ah batteries is the maximum size that will fit in the Master Panel Enclosure which has a battery mounting area (HxWxD) of 4 in. x 14.25 in. x 2.5 in. (101 mm x 362 mm x 64 mm). Larger batteries must be installed in a UL Listed battery enclosure. Electrical (Distributed Panel) Current Draw AMI: Alarm: 10 ma, Standby: 10 ma DCC: Alarm: 55 ma, Standby: 55 ma MBR: Alarm: 55 ma, Standby: 10 ma Batteries 2 Type: Two 12 VDC Gel Cell in series Current (battery charging): Depends on amplifier; EVX 25E/50E: 800 ma maximum EVX 100E: 1 A maximum Capacity: Depends on amplifier; EVX 25E/50E: 24 VDC, 18 Ah maximum EVX 100E: 24 VDC, 24 Ah maximum Power Input (primary): 120 VAC Input current: Depends on panel configuration. Input (circuits): all circuits at 24 VDC 2 Two 12 Ah batteries is the maximum size that will fit in the Distributed Panel Enclosure which has a battery mounting area (HxWxD) of 5 in. x 14.25 in. x 4 in. (127 mm x 362 mm x 101 mm). Larger batteries must be installed in a UL Listed battery enclosure. Mechanical Enclosure Color: Dimensions (h x w x d): Charcoal grey 27 in x 14.5 in x 4 in (685.8 mm x 368.3 mm x 101.6 mm)

4 Bosch EVAX System - High-rise Applications Ordering Information Ordering Information HMB-MP16 Master Panel 16 Switch/Input, includes DCC, ASC, SSC, PWR-2A, MMC, 1 SLC, 1 IOI, Swing Door and Cabinet HMB-DP Distributed Panel, 4 Audio Circuits Includes DCC, MBR, AMI, 1 MBK IN Standard Cabinet, no amplifiers in basic assembly HMB-MP16 HMB-DP EVX-T17528 Power Transformer for EVX 50E/100E Open frame, 28 VAC @ 180 VA MB-MBK Mother Board Relays Provides 4 Class B speaker loop outputs, a maximum of 2 MB MBK cards provide 8 Class B or 4 Class A speaker circuits per Distributed Panel EVX-T17528 MB-MBK HMB-DP/P Distributed Panel, 4 Fire Phone Circuits Includes DCC, MBR, 1 FPI, PWR 2A used for phone only systems HMB-DP-42 Distributed Panel, 16 Audio Circuits Includes DCC, AMI, 2 MBR, 4 MBK, 2 MBI in CAB 42 Cabinet Accessories MB-SLC Switch/LED Card 16 switches and LEDs for manual control at Master Panel MB-SSC Switch Scan Card Controls up to 8 Switch/LED Cards (128 Switches). Multiple (16) MB SSC cards can be used for a system capacity of 2048 switches. Field additions or replacement only. MB-MFA Master Fire Phone Assembly Master Panel's Fire Phone handset, plate and interface PC board MB-XI Extended Input Interface Adds 16 inputs to Master Panel MB-OI Output Interface Card Adds 16 outputs to Master Panel EVX-25E Expander Module 25 Watt Complete module with built-in tone generator capable of operating as a stand-alone Voice Evacuation System with only tone and microphone amplification; power transformer or cabinet not included EVX-50E Expander Module 50 Watt Complete module with built-in tone generator capable of operating as a stand-alone Voice Evacuation System with only tone and microphone amplification; power transformer or cabinet not included EVX-100E Expander Module 100 Watt Complete module with built-in tone generator capable of operating as a stand-alone Voice Evacuation System with only tone and microphone amplification; power transformer or cabinet not included EVX-T2885 Power Transformer for EVX 25E Open frame, 28 VAC @ 100 VA HMB-DP/P HMB-DP-42 MB-SLC MB-SSC MB-MFA MB-XI MB-OI EVX-25E EVX-50E EVX-100E EVX-T2885 MB-AMI Audio Module Interface Controls 2 EVX-25E/50E/100E Expander Modules in Distributed Panels MB-FPI Fire Phone Interface Provides 4 supervised Class B Fire Phone circuits in distributed panel (4 max 16 circuits). When more than one is used in a HMB DP Master Panel a MB FPO2 Fire Phone Output Adapter is required for each. MB-FPO2 Fire Phone Output Adapter Extra terminal card that must be used with the 2nd, 3rd and 4th MB FPI cards in a Distributed Panel MB-FO Fiber Optic Interface Card Provides termination for Fiber Optic communications between the Master Panel and the Distributed Panels EVB-BA100 Backup Audio Interface Provides a means to switch in a backup amplifier in the event of a primary amp failure MB-FJ Telephone Jack Brushed stainless steel single gang plate MB-FH Portable Handset Color red, 6 mount in MB TC cabinet MB-TC Fire Phone Cabinet Cabinet: charcoal gray, surface/semi-flush mount, key lock H x W x D: 27 x 14-1/2 x 4 in. MB-FS Fire Phone Station Coil cord, thumb turn latch, cabinet: red, surface/semi-flush mount H x W x D: 12-3/4 x 7 1/4 x 3 3/4 in. MB-WS Warden Station Cabinet: red, surface/semi-flush mount H x W x D: 12 3/4 x 7 1/4 x 3 3/4 in. MB-DCC Data Communications Controller MB-ASC Audio System Control MB-MMC Master Microphone Control MB-MBR Mother Board Remote Provides the 4 card slots (can be extended to max 7) for MB AMI and MB FPI and 2 MB MBK MB-PWR Master Panel Power Supply MB-AMI MB-FPI MB-FPO2 MB-FO EVB-BA100 MB-FJ MB-FH MB-TC MB-FS MB-WS MB-DCC MB-ASC MB-MMC MB-MBR MB-PWR

Bosch EVAX System - High-rise Applications 5 Ordering Information BATB-40 Battery Box The BATB-40 Battery Box holds two dry or wet cell batteries. The box can be used with fire alarm systems or intrusion systems. It measures 21 in. x 20.75 in. x 7.25 in. (53.3 cm x 52.7 cm x 18.4 cm). BATB-SHELF Optional Battery Shelf An optional battery shelf for the BATB-40. It allows two additional batteries to be placed in the battery box. BATB-80 Battery Box with Shelf The BATB-80 Battery Box holds up to four dry or wet cell batteries. The box can be used with fire alarm systems or with intrusion systems. It measures 12.25 in. x 20.75 in. x 7.25 in. (31.1 cm x 52.7 cm x 18.4 cm) on the bottom and 9.2 in. x 20.75 in. x 7.25 in. (23.2 cm x 52.7 cm x 7.25 cm) on the shelf. BATB-40 BATB-SHELF BATB-80

6 Bosch EVAX System - High-rise Applications Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch Security Systems Inc. 2011 Data subject to change without notice T7573892747 Cur: en-us, V1, 6 May 2011