Hydronic Specialties and Circulator Pumps

Similar documents
Taco 00 Series Cartridge Circulators

HVAC No. MFG Part No. Description Size Price

Packaged Semi-Instantaneous Steam Fired Water Heater

Davies Carries Parts for MF & SF Series Glycol Feeders

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Hydronic Mechanical Panels

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

WAL-RICH CORPORATION SINCE 1950

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

Installation, commissioning and servicing instructions

High Capacity Instantaneous Steam Fired Water Heater

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Semi-Instantaneous Indirect Fired Water Heater

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

DIRTCAL - DIRTMAG dirt separator

Packaged Steam Fired Water Heater

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION HYDRONIC PIPING AND SPECIALTIES

The smart way to instant hot water comfort.

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

NOW. Fall Heating Specials. Stock Up. & $ave! Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us!

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

WATER HEATER PARTS CTN. QTY.

The PurePro. Family of Indirect Water Heaters. A smart choice for abundant, rapid hot water heating. pureproproducts.com

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Technical Data Manual Model Nos. and pricing: see Price List

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Domestic Hot Water Systems and Plumbing Products

NOW. Fall Heating Specials. Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us! Stock Up. & $ave!

The PurePro. Family of Indirect Water Heaters. A smart choice for abundant, rapid hot water heating. pureproproducts.com

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Thermostatic Radiator Valves (Caleffi)

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

Automatic Temperature Controller (ATC)

1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

GRUNDFOS PLUMBING & HVAC PRODUCTS

"ER" Series Electric Humidifier

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT

TECHNICAL. Series 18. Pump Packages

Canadian Retail. Parts Catalogue

Table of Contents. 2 - JTG Muir - Taco Catalog

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed

Wood Boiler Plumbing Schematics

Canadian Retail. Parts Catalogue

2018 PLUMBING AND HYDRONICS CATALOG

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Indirect Fired Water Heater

PIONEERS IN AIR VACUUMS

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

Water Piping and Pumps

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Owner s Manual Therma-Stor II Heat Recovery System

University of Delaware

WATER SUPPLY HOOK-UP DISPLAY 0-WSH-1

SECTION STEAM CONDENSATE PUMPS

4. Provide brass valve tags marked for the service. See pertinent service specification for valve type.

SINGLE SPEED CIRCULATORS

OKLAHOMA STATE UNIVERSITY - BUILDING DESIGN STANDARDS

Heating system service plans that provide total peace of mind.

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

MACH N-407 Heat Pump Air-Cooled Chiller

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

DESIGN STANDARDS SECTION 15600

ProRadiant Controls, Valves and Actuators

WAL-RICH CORPORATION SINCE 1950

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Peerless Pump Company

SECTION METERS AND GAGES FOR PLUMBING PIPING

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

SECTION DOMESTIC WATER PIPING SPECIALTIES

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

MAC N-407 Air-Cooled Chiller

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

2019 PLUMBING AND HYDRONICS CATALOG

Well Tanks and Expansion Tanks

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

EXTROL EXPANSION TANKS

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

Allcan TM Installation Manual

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.

SECTION HEATING BOILERS

Standard Features. Performance/Capacities

TABLE OF CONTENTS BRADFORD WHITE BOILERS

Series 1156F, 1450F ( 1 2") Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers

Transcription:

Hydronic Specialties and Circulator Pumps PAGE 445-1 Boilermate Indirect-Fired Water Heater Uses any hot water boiler or generator to supply domestic hot water more efficiently than tankless coils and separate direct-fired units. Rapid recovery saves fuel. Proven three shell storage system keeps water hot up to 12 hours. Heat exchanger with double wall tubing. Prewired. Lifetime warranty. 445-0455 41 gallon capacity, 48" high x 22" diameter WH41-LDW Hot Water Maker Expansion Tanks Non-Potable Water Maximum Working Pressure: 100 PSI. Maximum Operating Temperature: 240 deg. F. System Connection: 1/2" MPT. Shipped with standard 12 PSI air charge which may be changed on the job to suit installation conditions. Expansion Tank 445-0520 Diaphragm Expansion 2 Gallon Tank MLEX15 11-1/2" high x 8" diameter. 445-0521 Diaphragm Expansion 4.4 Gallon Tank MLEX30 14" high x 11" diameter. Air Purger Models furnished with tappings indicated for installation on the main and for mounting. Air Purger 445-0600 Air Purger 1" FPT 431-6 445-0610 Air Purger 1-1/4" FPT 432-6 Air Vent Automatic For hot water systems. Float vent up to 45 PSI Air Vent 445-0760 Air Vent Automatic 1/8 MPT 400-3

Caleffi Boiler Products Boiler Trim Kits NA553 Series PAGE 445-2 The Caleffi NA553 Boiler Trim Kit is available in 10 configurations and combines 8 boiler installation components into one box. This kit matches the necessary components for boiler installations into a simple package. The NA553 takes all the guess work out of selecting components for a simple installation. The kit includes: 1 Caleffi DISCAL Air Separator 1 Backflow Preventer 1 AutoFill TM 1 Expansion Tank Check Valve 2 Brass Nipples 1 Brass Tee 1 Expansion Tank 1 NPT Boiler Trim NA553362 1 /4 NPT Boiler Trim NA553372 Magnetic Dirt Separators 5463 Series The DIRTMAG magnetic dirt separator removes both ferrous and nonferrous impurities continuously, featuring powerful removable magnets that remove up to 100% of the ferrous impurities, including magnetite, that can form in a hydronic system. The DIRTMAG has 2 ½ times the removal performance of a standard dirt separator. 1 /4 NPT Female Connections 546307A 1 /2 NPT Female Connections 546308A AutoFill Pre-Adjustable filling units & backflow preventer 573 Series Dual check continuous pressure backflow preventer with atmospheric vent. 1 /2 NPT Inlets, 1 /2 NPT Female Oulets 573002A

PAGE 445-3 G61-100 Pressure Gauges Stem Mount Generally used for hydraulic applications, such as presses, jacks and pumps, these specially designed heavy duty gauges can also withstand other rigorous pulsating and vibrating high pressure industrial applications. Ledge Mount. Code # Size Pressure Mounting Model # 445-2730 2-1/2 inch 100# 1/4" LM G61-100 Glass Tube Thermometers For direct installation on boilers and water heaters. Range 20 deg. to 260 deg. F. Scale length 5". 1-3/8" insertion length, 1/2" MPT connections. Brass Mounted. 445-3050 Thermometer Straight J40-501 445-3070 Thermometer Angle J40-503 J40-501 J40-503 Boiler Gauge Specially constructed for use on all hot water heating boilers, these combination gauges give accurate indication of temperature and pressure. Gauges are designed to withstand the conditions normally encountered on domestic heating systems. 1/2" connections. 445-3150 Boiler Gauge Straight HD11A4H52160L 445-3170 Boiler Gauge Angle HD11C4H52148L HD11 Cast Iron Y Type Strainers, Screwed End Connections For liquid or steam service. They are furnished with 250 lb. extra heavy iron body. Install strainers upstream to protect valves, regulators, solenoids and meters from dirt, rust and pipe scale. Self-cleaning can be accomplished by opening the valve or plug connected to the blow-off outlet. Iron retainer cap and asbestos gasket, straight threads and tapped for closure plug. Furnished with 20 mesh stainless steel screen. Working pressure - Non-shock. Steam pressure - 250 psi at 406 deg.f. Water, Oil, Gas - 400 psi at 100 deg.f. 445-3820 IPS 3/4 77S 445-3825 IPS 1 77S 445-3835 IPS 1-1/2 77S 445-3840 IPS 2 77S 77S

PAGE 445-4 Coin Air Assy. Loose Key Air Valve Coin Air Valve Loose Key Keeney Air Vents - 1/8" MIP 445-4180 Coin Air Valve Assembly 5 with 3/16" OD x 21" tube 445-4190 Coin Air Valve 4 445-4200 Loose Key Air Valve 2K 445-4210 Key Only for #2K Air Valve 3 Twin Flo II Kickspace Heaters - Models K42 and K84 Compact and functional Kickspace Heaters are designed for those small, tough-to-heat areas. Advanced design allows for installation above doors, under kitchen and bathroom cabinets, in a stair riser, on a bookshelf. Effective range 10-15 feet of uniform heating. 445-5150 Toe Space Heater K-42 Beacon Morris

Mainline Self-Seal Pipe Insulation PAGE 445-5 Mainline Pipe Insulation Polyelfin Pipe Insulation is low density, polymer-based and easy-to-apply tubing products that are available in a wide variety of sizes with a self-sealing design. The self-sealing design has a green release liner that is both easy to see and peel. Code # ID CTS IPS Ctn Qty R-Value 3 /8" Wall x 6 Lengths.1029594 1-1/8 1 3/4 31 2.98 ML11812SS.1029595 1-3/8 1-1/4 1 25 2.88 ML13812SS 1 /2" Wall x 6 Lengths.1029590 ( ) 5/8 1/2 3/8 50 3.54 ML5812SS.1029592 ( * ) 7/8 3/4 1/2 40 3.15 ML7812SS.1029596 1-5/8 1-1/2 1-1/4 20 2.97 ML15812SS.1029598 2-1/8 2 14 2.71 ML21812SS.1029599 2-3/8 2 12 2.71 ML23812SS 3 /4 Wall x 6 Lengths TUNDRA (MN Code Approved) 445-8206 ( * ) 1-1/8 1 3/4 17 4.8 11834T 1 Wall x 6 Lengths TUNDRA (MN Code Approved) 445-8270 ( * ) 3-1/2 3 12 5.4 31201T ( * ) Meets 2015 Minnesota Codes

PAGE 445-6 UP15-42F, UPS15-58FC, UP26-64F, UP26-99F Grundfos Pumps Flanged Pumps for Open and Closed hydronic systems. Grundfos pumps are singlestage, direct drive centrifugal pumps. The wet rotor design eliminates the need for routine maintenance and lubrication. Available with cast iron, stainless steel and bronze volutes, Grundfos circulators are designed for domestic and light commercial applications in open and closed systems. These pumps can be operated up tpo system pressures of 145 psi with maximum fluid temperatures of 230 deg.f and corresponding ambient temperatures of 104 deg. F. Mixtures of water and ethylene or propylene glycol solution up to 50% by volume may also be pumped. Less flgs. Brute 445-7760 Pump Cast Iron - closed system, UP15-42F 1-speed, 1/25 HP, 85 Watts, 115 Volts, 0.76 amps, 2475 RPM Capacitor - 10MF,160V Super Brute 445-7751 Pump Cast Iron- closed system UPS15-58FC 3-speed, 1/25 HP, Integral Check Valve, 115 Volts 445-7815 Pump Cast Iron - closed system UP 26-64F 1-speed, 1/12 HP, 185 Watts, 115 Volts, 1.62 amps, 2650 RPM Capacitor - 8MF/180V 445-7826 Pump Cast Iron, 1/6 HP, 115 Volts UP 26-99F

PAGE 445-7 CI Flange Bronze Flange Isolation Valve 3/4 Union Sweat Flange Ordering Chart Flange Use with Number Description models 51 9755 3/4" Bronze Isolation UP15-42F 51 9756 1" Bronze Isolation 51 9601 3/4" Cast Iron UP26-64F 51 9602 1" Cast Iron UP26-96F 51 9603 1-1/4" Cast Iron UP26-99F 51 9604 1-1/2" Cast Iron 51 9651 3/4" Bronze Sweat UP15-42SF 51 9652 1" Bronze Sweat 51 9755 3/4" Bronze Isolation 51 9756 1" Bronze Isolation 53 9605 1-1/2" Cast Iron UP43-75F HVAC Tapes 445-8326 Duct Tape 2" x 60 Yd. - Black 86-195722 445-8321 Duct Tape 2" x 60 Yd. - Silver 86-149263 Heavy Duty Grade 445-8348 All Weather Dead Soft Aluminum 86-216478 Foil Tape 3" x 50 Yd. 445-8346 UL Foil Tape 2 x 50 yds. 86-232032 445-8350 Rheem 2 x 60 yds. 3M Venture Line Set Tape 1507

PAGE 445-8 Model 0011 Cartridge Circulator 445-5010 1/8hp Cartridge Circulator 0011-F4 445-5705 Cartridge 0011-009RP Circulator Switching Relay The Taco Switching Relay is the best choice for all your zoning needs, with advanced PowerPort Cards, external diagnostic lights, switchable priority and contractor friendly PC board layouts. Combined with the time proven reliability of the 00 family of circulators and thermostats, total system integration is achieved. Switching Relays Product Number Number of Zones Transformer Voltage Maximum Combined Load Dimensions of Enclosure Width Height Depth SRSOI 1 Zone 120 VAC Input 7.2 amps 4 1/4 5 1/4 2 3/4 SR502 2 with Priority 120 VAC Input 1 5 amps 10 1/4 6 3/4 2 3/4 SR503 3 with Priority 120 VAC Input 1 5 amps 10 1/4 6 3/4 2 3/4 SR504 4 with Priority 120 VAC Input 20 amps 10 1/4 6 3/4 2 3/4 SR506 6 with Priority 120 VAC Input 20 amps 1 1 3/4 7 1/2 3 445-5710 1 Zone Relay SR501 445-5720 3 Zone Relay w/ Priority Switch SR503

PAGE 445-9 Model 007 Cartridge Circulator The Taco 007 Cartridge Circulator is the most popular hydronic circulator sold today. With its field serviceable cartridge design, the compact 007 provides quiet, efficient operation and unmatched reliability. The self-lubricating, maintenance free design and flow characteristics make it the ideal hydronic circulator for a wide range of applications. 445-5000 Cartridge Circulator 007-F7 Priority Zoning Circulator The patented Taco Priority Zoning Circulator combines the reliability of the 00 circulator with the convenience and efficiency of a switching relay. With a built-in transformer, relay and priority switch, all the wiring is done directly to the circulator s PC board, making it ideal for adding a zone or an indirect hot water heater. Now available with optional integral flow check (IFC ). 445-5005 1/25 HP Cast Iron Flanged Circ. Pump 007-ZF5-9 Model ZVC405 Zone Valve Control 445-5715 3-Zone Valve Control ZVC405

PAGE 445-10 Hot water without the wait Before Grundfos, hot water recirculation solutions were difficult, if not impossible. Now, installations in both new construction and existing homes are quick, easy and profitable. Comfort PM Auto - Whole House Hot Water Recirculation System The Comfort PM Auto range sets new standards for energy-efficient hot water recirculation in residential homes. Thanks to a low noise permanent magnet motor, energy consumption is reduced to as little as 5-8.5 W. Utilizing AUTOADAPT ensures the pump only runs when required, so the result is maximum comfort with lower wait times for hot water as well as reducing water and electrical waste. Easy installation Miminize water waste Lower energy consumption Learns and adapts to homeowner s water temperature needs 445-7757 Comfort PM Auto UP 10-16 A PM BN5/LC Comfort System - Single Sink Hot Water Recirculation System The water circulation system that eliminates cold water runoff at the faucet using a bypass valve and pump with a timer to control water flow. In retrofits, the Comfort System bypass valve makes it all possible with no return line and no need for electricity under the sink A wet rotor design for whisper-quiet and maintenance-free operation. 445-7755 Comfort System Retrofit UP 15-10 SU7P TLC Comfort Valve Kit for Hot Water Recirculation Systems 445-8005 Comfort Valve Kit - Bulk 595926