Directions for use MACH LED 300DF

Similar documents
Operating instructions MACH M3

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

Enhance DX. Mattress Replacement System. User Manual

CLETEF-786. Infrared Thermometer Instruction Manual

ULTRASONIC AIR SALINIZER. Owner s Manual. Saltair Home Salt Therapy

Veterinary Patient Warming System Controller User Manual

COOLFLOW IRRIGATION PUMP USER MANUAL

ASPIRE Laboratory Aspirator

PEAK Platelet Rich Plasma System

Instruction Manual Mini SAD Light Box Code: A54LC

TM Machine WetAlert TM Wireless Wetness Detector Home User s Guide

Veterinary Patient Warming System Service Manual. For information on operating the Hot Dog Patient Warming System, refer to the Instructions for Use

User Manual. Mistral-Air Plus Warming Unit. MA1100-EU ( V~, 50/60 Hz) MA1100-US ( V~, 60 Hz) MA1100-JP ( V~, 50/60 Hz)

Owner s/service Manual. LED Light Source for A-Series TM. Microscopes M A801-LED

5. Instrument and accessories discharging must be done following current law regulations in every country of use.

STS Directory Accreditation number: STS 0009

EPURE. LED surgical lights A fusion of design and innovation. Design that cares. Operating theatre

Operator s Manual. WarmTouch. Model WT-5900 Patient Warming System

INTERNATIONAL STANDARD

Operator s Manual. WarmTouch. Model WT-5300A Patient Warming System

EkoSonic Control Unit Instructions for Use

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Operating Instructions ATMOS LS 31 LED. English GA1GB Index 02

AUGUST 2016 CONTENTS:

INTERNATIONAL STANDARD

Transcend Heated Humidifier User Manual

CONTENTS IMPORTANT SAFEGUARDS INTRODUCTION PRODUCT DESCRIPTION INSTALLATION OPERATIONS CLEANING...

WARNINGS AND PRECAUTIONS FOR THE USE OF THE IQ TM Intelligent Driver

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

MaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S

User Manual. Advanced Markus Chamber Ionization Chamber Type 34045

HydraTherm TM OPERATION MANUAL

Operation and maintenance manual SERIES E/N

Remote alarm case VENTIremote alarm 10 m WM VENTIremote alarm 30 m WM Device description and instructions for use

Audible warning devices for external alarm

REA 105 Arc Protection Module. Operator s Manual

Installation instructions

Processing Instructions. Cleaning so easy.

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

CL1000 Ceiling Light OWNER S MANUAL. Marus Fruehauf Drive Charlotte, NC USA

CARESTREAM DRX-1 System

Dear customer, Be sure to use the device properly according to the instructions given by medical professionals.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Regulatory Information and Specifications

OPERATION MANUAL. Multi Function Ultrasonic Scaler. Varios 970. Please read this Operation Manual carefully before use, and file for future reference.

Table of Contents. English

User manual LED surgical light

Rules for Classification and Construction Additional Rules and Guidelines

This annex is valid from: to Replaces annex dated: Prolonged until

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

RESmart CPAP System. User Manual

INTERNATIONAL STANDARD

IB-CB200GB _Layout 1 16/12/ :02 Page 1. Instruction Manual. Customer Service Number +44 (0) CB-200-GB

EU Declaration of Conformity Annex

E-16 Main Engine Remote Control System

This is a preview - click here to buy the full publication

User Instruction Manual

Installation Instructions. Mira LED Light System

INFUSION PUMP J1060MN OPERATOR MANUAL

Important user information

UV Flame Supervision System

Instructions For Use

EU Declaration of Conformity Annex

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

CARESTREAM DRX-1 System Detector CARESTREAM DRX-1C System Detector CARESTREAM DRX 2530C Detector Model DRX User Guide

User Instruction Manual

MyKi Care Thermometer (MCT 1.0) USER MANUAL

This is a preview - click here to buy the full publication

Operating Manual. VIENNA Hot Display

Model IC-1545-DL Multi-Flo DVT Combo

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

OPERATORS GUIDE Rocket R54569 PSU

M7100 Pressure Transducer

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

OPERATION & CARE MANUAL FOR P-2010-S BLANKET WARMING CABINET

BNT-1000 Infant Radiant Warmer Operate Manual

Alarm System SECURE AS 302

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

CERTIFICATE OF ACCREDITATION

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

HARMONY LED385 EXAMINATION LIGHTING SYSTEM


SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Radio Society EMC Advice Leaflet EMC 03 of Great Britain

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Iron - low. - medium - high Do not iron. Bleach - chlorine. Do not bleach. Tumble dry - low - medium - high Do not tumble dry

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Transcription:

Directions for use MACH LED 300DF Design with central reflector available against surcharge Dr. Mach GmbH u. Co. KG, Flossmannstrasse 28, D-85560 Ebersberg Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50 Internet: www.dr-mach.com, E-mail: info@dr-mach.de 59170002 Edition 13 09.09.2016 / Bak We page 1/27

List of contents 1. Safety instructions... page 4 2. Brief description of the light MACH LED 300DF... page 7 2.1 Accessory... page 7 3. Operating the lamp MACH LED 300DF... page 8 3.1 Light functions... page 8 3.1.1 Merging of light fields... page 8 3.1.2 Focusing... page 8 3.1.3 Light intensity control... page 9 3.2 Turning the lamp ON/OFF... page 9 3.3 Endo-Light... page 9 3.4 Adjusting the illuminated area by merging of light fields... page 9 and focusing Duo Focus system 3.5 Overview of the lamp functions... page 10 3.6 Adjusting the light intensity... page 11 3.7 Positioning... page 12 3.8 Danger of collision while positioning the lights... page 13 3.9 Addition to positioning the lamp... page 13 4. Cleaning... page 14 4.1 Sterilisable handle... page 14 4.2 Lamp housing, dispersing lens and support system... page 16 5. Initial operation and Maintenance... page 17 5.1 Activity at initial operation and maintenance work... page 17 5.2 Adjustment at the lamps head... page 18 5.3 Removing the upper housing part... page 18 5.4 Replacing the protection disk... page 19 6. Data... page 20 6.1 Technical data... page 20 6.2 Electrical data... page 21 6.3 Information regarding the electrical installation... page 21 6.4 Weights... page 21 6.5 Environmental conditions... page 22 6.6 Important remarks... page 23 7. CE-mark... page 23 8. Disposal... page 23 9. Electromagnetic compatibility... page 24 59170002 Edition 13 09.09.2016 / Bak We page 2/27

Dear customer! Congratulations for achieving our new OT-lamp MACH LED 300DF. The new OT-light generation with LED technology supports your professionality by innovative technology and design. The advantages of the LED technology: adjustable light colour, a life-span of minimum 50.000 hours and an almost non-existent heat development in the surgeon s head area and in the wound field. The advantages already provided by Dr. Mach s light technology with halogen and gas discharge lamps have been maintained: natural colour reproduction, exact illumination of the wound field and easy positioning of the light head. All information quoted here relates only to the illuminants. Details of ceiling or wall installation can be found in the mounting instructions. 59170002 Edition 13 09.09.2016 / Bak We page 3/27

1. Safety instructions Pay attention to the instructions for use when handling the lamp. WARNING: This device has not been designed for use in potentially explosive areas. According to the Medical Device Regulation the light is classified under class I. Store the OT-light in its package for at least 24 hours in the respective room before mounting, in order to equal temperature differences. Please read the instructions for use carefully to make the most of your lighting system and to avoid any damages to the device. The lights may only be repaired and special assembly work may only be carried out on the reflector or sockets by ourselves or a company that has been expressly authorised by us. The manufacturer can only be made responsible for the safety of the light if repairs and alterations are carried out by the manufacturer himself or a company that guarantees to observe the safety regulations. No modification of the lamp is allowed! The manufacturer cannot be made liable for personal or material damages if the light is operated inexpediently or incorrectly or used for purposes other than those for which it is intended. The light is to be dismantled from the spring arm in reverse order to its assembly. This may only be carried out after the spring arm has been adjusted in height at horizontal position since the arm is under spring tension and can bounce up. Make sure that the light is in perfect working order before every use. Attention, external power supply! The light works only with an external power supply 250VA or 200VA. The external power supply used with the OT-light must be tested and validated according to IEC 60601-1. Attention! A main control switch must be installed for turning the system power-off. The switch must meet the requirements of the standard IEC 61058-1 regarding rated voltage peaks of 4kV. During the mounting of the OT-lights the entire system (incl. the ceiling attachment) must be disconnected from mains! A later dismounting of the lights from the spring arms or dismounting the sliding contacts inside the arms is to be done ONLY AFTER DISCONNECTING THE ENTIRE SYSTEM FROM MAINS. Otherwise the main control board will be damaged! 59170002 Edition 13 09.09.2016 / Bak We page 4/27

Symbols and notes used in this user manual: This symbol means possible hazard sources. Please observe also the safety remarks and the hazard specifications mentioned in the mounting instructions and user manuals from Ondal company. This symbol means possible hazard caused by electric current. Please observe also the safety remarks and the hazard specifications mentioned in the mounting instructions and user manuals from Ondal company. This symbol refers to important mounting indications, useful information and operation hints. Temperature range for transport and storage Indication for disposal CE- conformity mark This way up Keep dry Fragile, Handle with care 59170002 Edition 13 09.09.2016 / Bak We page 5/27

Symbols and notes used on the device: This symbol indicates to observe the user manual. Indication on China RoHS / Pollution control Logo China Temperature range for transport and storage Indication for disposal Serial number of the product Article number of the product Address of manufacturer / distributor of the product Year of manufacture CE- conformity mark Quality control 59170002 Edition 13 09.09.2016 / Bak We page 6/27

2. Brief description of the light MACH LED 300DF Mach LED 300DF intended use: The Mach LED 300DF lighting system is designed for illuminating an examination area and surgical field at the hospital and doctor s practice. Mach LED 300DF indications for use: The surgical light MACH LED 300DF is intended to illuminate the surgical field and the patient s body with a high intensity, shadow-free and cold light. Essential Performance: The OT-lights MACH LED 300DF are intended to provide the illumination in depth and to restrict the energy on the operating field. General product description: The Mach LED 300DF lighting system is a minor OT-light according to EN 60601-2-41, which is not fail-safe when used as a single light. The Mach LED 300DF lighting system is designed for illuminating an examination area and surgical field at the hospital and doctor s practice. The Mach LED 300DF lighting system is install in medical used rooms (Group 0,1 and 2 to DIN VDE 0100-710 respectively HD 60364-7-710). This light system can be added to the ceiling mounted suspension system supporting the horizontal arms and spring arms. The light system is operated by a keypad on the lamp head or, by special request of the customer, by a keypad on the wall. The OT-lamp MACH LED 300 is available in following versions: - Duo-Focus OT-lamp (DF) with merging of light fields, focusing and electronic light intensity control - Duo-Focus OT-lamp (DF) with merging of light fields, focusing, electronic light intensity control and additional central reflector for an improved depth illumination 2.1. Accessory The accessories for the Mach LED 300DF lighting systems are as follows: Camera module Remote control for camera module Single monitor yoke for flat panel monitors Double monitor yoke for flat panel monitors Instrument trays 24V DC battery backup support Sterile handle sleeves 59170002 Edition 13 09.09.2016 / Bak We page 7/27

3. Operating the lamp Mach LED 300DF 3.1 Light functions 3.1.1 Merging of light fields The F-model offers light field adjustment by merging the individual light fields of each LEDcluster by swivelling them. NOTE: This feature is activated by turning the sterilisable handle. 3.1.2 Focusing The DF-model offers a second additional facility to further adjust the illuminated field to an extra small or extra-large size, depending on the specific requirements, by focusing. NOTE: This feature is activated by turning the ring at the top of the sterilisable handle. 59170002 Edition 13 09.09.2016 / Bak We page 8/27

3.1.3 Light intensity control The OT-lamp models LED 300DF offer a standard feature, the light intensity control. You can adjust the light intensity between 50% and 100%, according to your requirements. 3.2 Turning the lamp ON/OFF 1 The lights LED 300DF are switched ON/OFF at the main switch of the OT or at the ON/OFF switch at the cardan bow. The lights LED 300DF are switched ON/OFF with the touch-button 1 at the key-pad of the lamp. 2 3 3.3 Endo- light In case of endoscopic intervention the light of the OTlamp can be dimmed. The Endo mode is activated by repeated pressing of the key, until only LED 2 is on. When pressing the key again, LED 2 goes off and LED 3 turns on automatically. The Endo mode is now active. This mode can be deactivated by pressing the + key. 3.4 Adjusting the illuminated area by merging the light fields and focusing Duo-Focus system All lamp models LED 300DF offer the feature of merging the light fields and focussing. Merging of light fields is activated by turning the sterilisable handle 2. Focusing is activated by turning the ring 3 at the sterilisable handle. 2 3 59170002 Edition 13 09.09.2016 / Bak We page 9/27

3.5 Overview of the lamp functions Merging of light fields and focusing MERGING OF LIGHT FIELDS Merging the individual light fields of each LED-cluster is done by swivelling the reflectors. The light fields overlap. This feature is activated by turning the sterilisable handle (1). Ring (2) FOCUSING Handle (1) By focusing you can further adjust the illuminated field to an extra small or extra-large size, depending on the specific requirements. This feature is activated by turning the ring (2) at the top of the sterilisable handle. Always activate merging of light fields first by turning the handle (1), then activate focusing when necessary by turning the ring (2)!! 59170002 Edition 13 09.09.2016 / Bak We page 10/27

Key pad 3.6 Adjusting the light intensity Select the desired light intensity before the operation. At these models the adjustment is done by the keypad at the cardan bow. The intensity can be infinitely adjusted between 50% and 100%. 3 Press push button 2 to increase the light intensity and press push button 3 to reduce the light intensity. The light intensity set is shown by LED-display 1. 1 2 59170002 Edition 13 09.09.2016 / Bak We page 11/27

3.7 Positioning 1 Use the sterile handle 2 or the handle rails 1 to position the lamps. 1 Use the handle rail to position the lights before the operation. Use the sterile handle for positioning during the operation. This handle can be removed for sterilization. 2 Remark: Position the light only with the handle or the special designed parts on the light housing The working distance of the lamps is 0,6m to 1,5m. 1,5m 1m 0,6m 0 Two or more lamps can be used for an intensive illumination of large operation field. It is also possible to illuminate two operation fields simultaneously. 59170002 Edition 13 09.09.2016 / Bak We page 12/27

3.8 Danger of collision while positioning the lights During positioning, eventual collisions between the lights, spring arms and other devices must be avoided. Cover parts can get loose and fall down. 3.9 Addition to positioning the lamp When the spring arm and extension arm are in a 180 position, the lamp head cannot be moved in the direction of the suspension axis. A repeated force of > 25 N (according to EN 60601-2-41) at this angle can lead to damage. This applies for all ceiling and wall mounted lamps (example in picture). In order to be able to move the lamp in the direction of its suspension axis, the angle between the extension arm and spring arm must be < 180. 59170002 Edition 13 09.09.2016 / Bak We page 13/27

4. Cleaning 1 V 4.1 Sterilisable handle At delivery the lamp is equipped with the handle sleeve 1. The handle sleeve is removable and sterilisable. Before using the first time and before every use the handle sleeve must be cleaned, disinfected and sterilised. The handle sleeve must be removed for sterilisation: To remove press the lock V and pull off the sterilisable handle sleeve 1 while keeping the lock pressed. To attach, hold the handle loose, push on and slightly twist the handle until the lock V engages securely. Handles often become unsterile during an OP; therefore always keep additional handles available for exchange. Cleaning / disinfection and sterilisation Basics Efficient cleaning / disinfection is an essential requirement for effective sterilisation of the handle. Within the scope of responsibility for the sterility of the products it should be noted that only sufficiently validated equipment and product specific processes are used for cleaning / disinfection and that the validated parameters are complied with in every cycle. In addition, the hospital / clinic hygiene regulations must be observed. Remark: The requirements of the national committees (standards and directives) for hygienics and disinfection must be observed. Cleaning / disinfection Cleaning and disinfection must be carried out immediately after use. A mechanised process (disinfector) should be used for cleaning / disinfection. The efficiency of the process used must be recognised and validated in principle (e.g. listed under disinfectants and disinfection procedures tested and recognised by Robert-Koch-Institute / DGHM). When using other procedures (e.g. a manual procedure), proof and process efficiency in principle must be provided within the scope of validation. Proof in principle of the suitability of the handles for efficient cleaning / disinfection was provided using a cyclic cleaning system (Netsch-Bellmed T-600-IUDT/AN, programme 2 for small parts; code B). It is not allowed to use agents / disinfectants, which contain the following substances, as these may cause changes in the material: - High-concentration organic and inorganic acids - Chlorinated hydrocarbons - 2-ethoxyethanol 59170002 Edition 13 09.09.2016 / Bak We page 14/27

When cleaning / disinfecting, the following procedures must be followed: Process Time (sec.) Zone 1 Pre-rinse, external, cold, 10 15 C 45 Washing, acidic, external 35 C 120 Draining time 10 Re-rinse, external approx. 80 C *10 Draining time *15 Re-rinse, external approx. 80 C *15 Draining time 15 Zone 2 Washing, alkaline, external, 93 C 135 Draining time 10 Re-rinse, external, acidic, 90 C 10 Draining time 15 Re-rinse, external 90 C 15 Draining time 15 Zone 3 Drying, external 100 120 C 200 Zone 4 Drying, external 100 120 C 200 Door open / close & transport 60 (sluice discharge) Cycle time overall ca. 290 5 minutes * When occupying the disinfection zone (washing zone 2), the re-rinse and draining times will depend on the respective objects being washed therein! Sterilisation Only previously cleaned and disinfected handles may be sterilised. The handles are placed in a suitable sterilisation pack (one-way sterilisation pack, e.g. foil / paper sterilisation bags, single or double pack) in accordance with DIN EN 868 / ISO 11607 for steam sterilisation and then sterilised. Use only the sterilisation procedure listed below for sterilisation. Other sterilisation procedures (e.g. ethylene oxide, formaldehyde and low-temperature plasma sterilisation) are not permissible. Steam sterilisation procedure Validated in accordance with DIN EN 554/ISO 11134 Maximum sterilisation temperature 134 C Proof in principle of the handles suitability for effective sterilisation was provided using a fractional vacuum process (Euroselectomat 666 by MMM Münchner Medizin Mechanik GmbH, sterilising temperature 134 C, holding time 7 min.) When applying other sterilization procedures, the suitability and effectiveness of the process must be validated. 59170002 Edition 13 09.09.2016 / Bak We page 15/27

Inspection / durability The sterilisable handle sleeve must be disposed after 1000 sterilisation cycles or at the latest after 2 years and replaced with a new one. The year of manufacture can be determined with the help of a stamping on the inner side of the handle sleeve (like shown in the photo). The stamping in the photo shows the number 12, which stands for the year 2012. 4.2 Lamp housing, protective disk and support system The OT-lamp MACH LED 300DF has a high-quality surface, which can be cleaned with conventional disinfectants. The protective disks 2 are made of a high-quality plastic. Pay attention to the following during cleaning: - Never wipe over the protective disks 2 with a dry cloth (always clean with a wet cloth). - Wipe the protective disks 2 after cleaning with an antistatic, non-fluffy cloth. 2 59170002 Edition 13 09.09.2016 / Bak We page 16/27

5. Initial operation and Maintenance MACH LED 300DF lights are supplied with a brake screw on the lamp s yoke and on the lamp housing. If the lamp is difficult to move or if it does not keep its position, the brake forces should be adjusted by turning the brake screw left or right as needed with a flat head screw driver. brake screw MACH LED 300DF lights are supplied with brakes on the suspension fixture and on the lamp housing. Adjust these brakes, if necessary, after installation. Preventive maintenance of the light should be done every two years. This includes a technical and mechanical check-up. Please observe also the mounting instructions and instructions for the carrying systems. These instructions can contain statements for different maintenance intervals. Basis of the examination of the lighting and load-bearing systems forms the DGV V3 (formerly BGV-A3) in connection with the EN 62353. Attention: Set the height adjustment, if applicable, of the spring arm to horizontal position before dismounting the lamp. Please observe also the mounting instructions and instructions for the carrying systems. Attention: During all maintenance work the light must be disconnected from mains and secured against resetting. 5.1. Activity at initial operation and maintenance work The following maintenance work / tests has / have to be done: check on defects in paint work; check on fissures at plastic parts; check on deformation of the suspension. check on loosened parts; check the connection between light and carrying system; check and grease the securing segment; check the faultless function of the light; perform the electrical safety tests For adjustments at the ceiling attachment please observe also the mounting instructions Ceiling attachment with heavy central axis or Ceiling attachment wall attachment from Dr. Mach. Remark: Wiring diagrams, complete spare parts lists and maintenance manuals can be provided on request. It is not allowed to exchange spare parts and make repair work while the light is in operation. It is not allowed to touch parts below the housing cover and to touch the patient at the same time. 59170002 Edition 13 09.09.2016 / Bak We page 17/27

5.2 Adjustments at the lamp head The fine adjustment for handling the lamps can be carried out at points 2 and 3. To adjust the brakes use a screw driver with appropriate size. If you cannot adjust the brakes at points 2 and 3 anymore as tight as necessary, you will have to replace them. 3 2 5.3 Removing the upper housing part Turn the cover to the right and remove it. In case of the light with centre spot turn the open ring to the right and remove it. In case of the light with camera please remove the camera according to chapter 7 of the mounting instructions 50460003 video system HD. After removing the cover you can see three screws. Loosen these screws with a screwdriver and remove them. 59170002 Edition 13 09.09.2016 / Bak We page 18/27

After loosening and removing the screws, the upper housing part can be removed. To fix the cover, position the cover on the light, fix it with the screws and close the ring with a turn to the left. 5.4 Replacing the protection disk After the upper housing part has been removed (see chapter 4.3), loosen the 6 screws at the ring and remove them. Loosen the disk from the ring and remove. Replace the disk in reverse order. 59170002 Edition 13 09.09.2016 / Bak We page 19/27

6. Data 6.1 Technical data Mach LED 300DF Mach LED 300DF with Spot* Central light intensity at a distance of 1 meter 140.000 Lux 160.000 Lux* Light field diameter d 10 140 mm 140 mm Light field diameter d 50 70 mm 75 mm Light intensity with one shadower 47 % 36 % Light intensity with two shadowers 45 % 52 % Light intensity on the ground of a normed tube Light intensity on the ground of a normed tube with one shadower Light intensity on the ground of a normed tube with two shadowers 100 % 100 % 47 % 36 % 45 % 52 % Illumination depth 60 % 335 mm 450 mm Illumination depth 20 % 740 mm 1440 mm Colour rendering index R a 95 95 Colour rendering index R 9 94 94 Electronic light intensity control at the lamp Max. radiation in field in a distance of 1 meter Max. radiation in field in a distance of 0,95 meter 50-100% 50-100 % 464 W/m² 541 W/m 2 551 W/m 2 Focussable size of the light field 14-28 cm 14-28 cm Colour temperature (Kelvin) 4500 K 4500 K Temperature increase in head area 0,5 C 0,5 C Height adjustment 118 cm 118 cm Number of LED s 36 36 Life span of LED s 50.000 h 50.000 h Light head diameter 55 cm 55 cm * Surcharge for central reflector Remark: The technical data are subject to fluctuations. Due to manufacturing reasons the real values can slightly differ from the data mentioned above. The values for R a and R 9 can differ with approx. ± 5%. The values for the colour temperature can differ with approx. ± 200K. 59170002 Edition 13 09.09.2016 / Bak We page 20/27

6.2 Electrical data Mach LED 300DF Mach LED 300DF with Spot Power consumption 50 W 55 W Operating voltage DC 24 30 V DC 24 30 V DC Current 2,1 A 2,3 A 6.3. Information regarding the electrical installation When turned ON, the OT-light MACH LED 300DF is exposed to a current peak. The OT-light MACH LED 300DF is delivered with a Dr. Mach power supply. It is an electronic power supply with a wide-range input, input voltage 100 240V AC, 50 60Hz, output voltage 28V DC. In case there is a switch-over relay needed for a emergency power supply on site, this switch over relay must be ordered separately at Dr. Mach. In case of a power supply provided by the customer, the following points must be observed: The OT-light works with 24V 30V DC (direct voltage). The direct voltage provided by the hospital must have a maximum undulation of 5%. A higher voltage (28V 30V DC) is recommended, this causes a decrease in heat development of the light. Warning! The light is class I. equipment. In order to avoid the risk of an electric shock, the equipment must be connected to a mains supply with protective earth. 6.4. Weights Light Weight Mach LED 300 DF 14 kg* * without handle 59170002 Edition 13 09.09.2016 / Bak We page 21/27

6.5 Environmental conditions Operation Min. Max. Temperature +10 C +30 C* Relative atmospheric humidity 30 % 75 % Air pressure 700 hpa 1060 hpa * in case of higher temperatures please contact us Transport / storage Min. Max. Temperature -10 C +50 C Relative atmospheric humidity 20 % 90 % Air pressure 700 hpa 1060 hpa References on the package This way up Keep dry Fragile, Handle with care Temperature range for transport and storage Atmospheric humidity for transport and storage Air pressure for transport and storage 59170002 Edition 13 09.09.2016 / Bak We page 22/27

6.6. Important remarks When using more than one OT-lamp at the same time (OT-lamp combinations), due to the overlapping of the light fields of different lights, the total radiation intensity can exceed the value of 1000 W/m 2. This means a risk of higher heat development in the wound field. When using more than one OT-lamp at the same time (OT-lamp combinations), due to the light fields overlapping of different lights the maximum permissible values for UV-radiation (< 400 nm) of 10 W/m² can be exceeded. The test certificate for the electrical safety test can be requested when needed. Please provide the serial number of the respective light. In case of a collective wiring of further lights or devices at installation, chapter 16 of the European standard EN 60601-1:2013 must be applied and eventually it has to be checked if the requirements are met. The light must be tested according to EN 62353 at commissioning. The polarity is very important for the installation of the light. In case the light does not function after installation, the polarity must be checked at the secondary side of the power supply. 7. CE-mark The products Mach LED 300DF comply with the standards 93/42/EEC for medical products of the European Community s Council. Dr. Mach applies the standard EN 60601-2-41. Dr. Mach GmbH is certified according to EN ISO 13485:2012 + AC:2012. 8. Disposal The OT-lamp doesn t contain any dangerous goods. The components of the OT-lamp should be properly disposed at the end of its shelflife. Make sure, that the materials are carefully separated. The electrical conducting boards should be submitted to an appropriate recycling proceeding. The rest of the components should be disposed according to the contained materials. 59170002 Edition 13 09.09.2016 / Bak We page 23/27

9. Electromagnetic compatibility The Dr. Mach OT- and examination lights are subject to special preventive measures regarding the electromagnetic compatibility and must be installed according to the EMC-instructions mentioned in the accompanying documents. The function of the OT- and examination lights can be affected by portable and mobile HF-communication devices. The use of other equipment than the equipment mentioned in chapter 2. leads to an increased emission or to a reduced interference resistance of the device. For the intended use of the OT-light MACH LED 300DF it is required that the light MACH LED 300DF is not mounted immediate and near to other devices or mounted together with other devices. If operating the light is obligatory near other devices or together with other devices, the functions of the light MACH LED 300DF must be observed. Table 1 Guidance and manufacturer s declaration electromagnetic emission for all EQUIPMENT AND SYSTEMS Guidance and manufacturer s declaration electromagnetic emission The MACH LED 300DF is intended for use in the electromagnetic environment specified below. The customer or the user of the MACH LED 300DF should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment - guidance Harmonic emissions IEC 61000-3-2 Voltage fluctuations / flicker emissions IEC 61000-3-3 RF emissions CISPR 15 Class A Complies Complies The MACH LED 300DF is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. The MACH LED 300DF is not suitable for interconnection with other equipment. 59170002 Edition 13 09.09.2016 / Bak We page 24/27

Table 2 Guidance and manufacturer's declaration electromagnetic immunity for all EQUIPMENT and SYSTEMS Guidance and manufacturer s declaration electromagnetic immunity The MACH LED 300DF is intended for use in the electromagnetic environment specified below. The customer or the user of the MACH LED 300DF should assure that it is used in such an environment. Immunity test Electrostatic discharge (ESD) IEC 61000-4-2 Electrical fast transient / burst IEC 61000-4-4 Surge IEC 61000-4-5 Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 IEC 60601 test level ± 6 kv contact ± 8 kv air ± 2 kv for power supply lines ± 1 kv for input/output lines ± 1 kv differential mode ± 2 kv common mode < 5 % U T (>95 % dip in U T ) for 0,5 cycle 40 % U T (60 % dip in U T ) for 5 cycles 70 % U T (30 % dip in U T ) for 25 cycles ± 6 kv contact ± 8 kv air ± 2 kv for power supply lines Compliance level not applicable ± 1 kv differential mode ± 2 kv common mode < 5 % U T (>95 % dip in U T ) for 0,5 cycle 40 % U T (60 % dip in U T ) for 5 cycles 70 % U T (30 % dip in U T ) for 25 cycles Electromagnetic environment - guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. If the user of the MACH LED 300DF requires continued operation during power mains interruptions, it is recommended that the MACH LED 300DF be powered from an uninterruptible power supply or a battery. Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 < 5 % U T (>95 % dip in U T ) for 5 sec 3 A/m 30 A/m < 5 % U T (>95 % dip in U T ) for 5 sec Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. NOTE U T is the a. c. mains voltage prior to application of the test level. 59170002 Edition 13 09.09.2016 / Bak We page 25/27

Table 4 Guidance and manufacturer s declaration electromagnetic immunity for EQUIPMENT and SYSTEM that are not LIFE-SUPPORTING Guidance and manufacturer s declaration electromagnetic immunity The MACH LED 300DF is intended for use in the electromagnetic environment specified below. The customer or the user of the MACH LED 300DF should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance Portable and mobile RF communications equipment should be used no closer to any part of the MACH LED 300DF, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Conducted RF 3 V 3 V d = 1, 17 Recommended separation distance P IEC 61000-4-6 150 khz to 80 MHz Radiated RF 3 V/m 3 V/m d = 1, 17 P 80 MHz to 800 MHz IEC 61000-4-3 80 MHz to 2,5 GHz d = 2, 34 P 800 MHz to 2,5 GHz where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). b Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. b Interference may occur in the vicinity of equipment marked with the following symbol: NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the MACH LED 300DF is used exceeds the applicable RF compliance level above, the MACH LED 300DF should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the MACH LED 300DF. b Over the frequency range 150 khz to 80 MHz, field strengths should be less than 3 V/m. 59170002 Edition 13 09.09.2016 / Bak We page 26/27

Table 6 Recommended separation distances between portable and mobile RF communications equipment and the EQUIPMENT or SYSTEM - for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING Recommended separation distances between portable and mobile RF communications equipment and the MACH LED 300DF The MACH LED 300DF is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the MACH LED 300DF can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the MACH LED 300DF as recommended below, according to the maximum output power of the communications equipment Separation distance according to frequency of transmitter m Rated maximum output of transmitter 150 khz to 80 MHz d = 1, 17 P 80 MHz to 800 MHz d = 1, 17 P 800 MHz to 2,5 GHz d = 2, 34 P W 0,01 0,12 0,12 0,23 0,1 0,37 0,37 0,74 1 1,17 1,17 2,33 10 3,69 3,69 7,38 100 11,67 11,67 23,33 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. 59170002 Edition 13 09.09.2016 / Bak We page 27/27