Portable Air Conditioner Instruction Manual

Similar documents
Portable Room Air Conditioner and Heat Pump

Dual-Hose Portable Air Conditioner User Manual

WA-1351DE: 12,000BTU DUAL-HOSE SYSTEM INSTRUCTIONS MANUAL

10,000 BTU Portable Air Conditioner

WA-1240E: 12,000 BTU Cooling only WA-1240H: 12,000 BTU Cooling and Heating WA-1420E: 14,000 BTU Cooling only WA-1420H: 14,000 BTU Cooling and Heating

Portable Air Conditioner (Local Air Conditioner)

USER MANUAL MPF. EasyCool Portable. MPF08CR71 MPF10CR71 MPF12CR71 MPF14CR71

Mobile Type AIR CONDITIONERS (LOCAL AIR CONDITIONERS)

PORTABLE AIR CONDITIONER

OWNER'S MANUAL MODEL: P-08PE P-12PE. For any service needs, call

Portable Room Air Conditioner and Heat Pump

Portable Air Conditioner (Local Air Conditioner)

Portable Room Air Conditioner

Portable Room Air Conditioner

SERVICE NUMBER ( )

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can

PORTABLE AIR CONDITIONER OWNER'S MANUAL. Model: MPM3-12HRN1-BH9 Model: MPM3-14CRN1-B I 6

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

MOBILE TYPE AIR CONDITIONERS

Sociable remark...2. Safety rules...3 Operating condition...3 Electrical information...4. Accessories...4 Names of parts...5

Downloaded from manuals search engine

PORTABLE AIR CONDITIONER

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can

Instruction Manual. Portable Air Conditioner

HMCI 125F-EH MOVABLE TYPE AIR CONDITIONER WITH OZONE-FRIENDLY R410A REFRIGERANT USER S MANUAL CAUTION:

ACCESSORIES INCLUDED

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Utopian Portable A/C

Local air conditioner

5) Do not start or stop the unit by inserting or pulling out the power plug.

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

PORTABLE AIR CONDITIONER

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

WHYNTER ECO-FRIENDLY 10,000 BTU PORTABLE AIR CONDITIONER

Air Conditioner Features...8 Operating Instruction Care and Cleaning...17 Before You Call...18 Major Appliance Limited Warranty...

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual


OWNER S MANUAL. Portable Dehumidifier: BHD-H Series BHDP-H Series R-410A

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

Remote Controller Manual

POLOCOOL USER MANUAL. For. PC-53AP/C 19,000 BTU(5.5kW) PC-44BP/C 15,000 BTU(4.4kW) PORTABLE REFRIGERATED AIR CONDITIONER

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

AC-12200E Portable Air Conditioner

Moveable Air-conditioner User s Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

P O R T A B L E Air Conditioner

PORTABLE AIR CONDITIONER

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Portable Air Conditioner User Manual

PORTABLE AIR CONDITIONER

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

DEHUMIDIFIER INSTRUCTION MANUAL

WHYNTER 14,000 BTU PORTABLE AIR CONDITIONER AND HEATER WITH 3M SILVERSHIELD FILTER PLUS AUTOPUMP

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

Operating Instructions

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

Portable Air Conditioner

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

USER MANUAL FOR MODELS: 4FPC FPC12000 COMFORT...BUILT TO LAST 10,000 & 12,000 BTU WINDOW AIR CONDITIONER

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Portable Air Conditioner User Manual Read and save these instructions before use

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Portable Room Air Conditioner Remote Control for:

USER MANUAL FOR MODELS: 4PAC6000 4PAC8000 4PAC PAC12000 COMFORT...BUILT TO LAST 6,000, 8,000, 10,000 & 12,000 BTU WINDOW AIR CONDITIONER

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

USER MANUAL. Safety Precautions. Operating Instructions. Installation Instructions. Care and Cleaning. Troubleshooting Tips

USER MANUAL FOR MODEL: 4PAC5000 COMFORT...BUILT TO LAST 5,000 BTU WINDOW AIR CONDITIONER

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

WHYNTER ECO-FRIENDLY 8,000 BTU PORTABLE AIR CONDITIONER

Portable Air Conditioner. Instruction Manual

WINDOW / WALL-TYPE ROOM AIR CONDITIONER

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Portable Air-conditioner

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

USER MANUAL FOR MODELS: 2PAC6000 2PAC8000 2PAC PAC PAC Your Source for Home Comfort

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

WINDOW AIR CONDITIONERS

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

15,000 BTU Portable Air Conditioner

VMH 09/12/18/24 SD Series Inverter Single Zone Ductless Mini-Split

POLOCOOL USER MANUAL. 10,000 BTU (2.9kW) 12,000 BTU (3.5kW) PORTABLE REFRIGERATED AIR CONDITIONER. For JULY 2017

Transcription:

Portable Air Conditioner Instruction Manual WA-1240AE1: 12,000BTU (cooling only) WA-1240H1: 12,000BTU (cooling & heating) WA-1420E1: 14,000BTU (cooling only) WA-1420H1: 14,000BTU (cooling & heating) Thank you for purchasing our Portable Air Conditioner. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. READ AND SAVE THESE INSTRUCTIONS!

Contents P r e p a r a t i o n S a f e t y P r e c a u t i o n s C a u t i o n s D e s i g n a n d C o m p l i a n c e N o t e s I n s t a ll a ti o n O p e r a t i o n M a i n t e n a n c e T r o u b l e S h o o t i n g S o c i a b l e R e m ar k

Preparation control panel horizontal louver blade (swing automatically) handle (both sides) upper air filter (behind the grille) upper air intake upper drain outlet air outlet lower air filter lower air intake lower drain outlet (heating models only) power cord outlet power cord buckle Caster power plug socket bottom tray drain outlet f r o n t r e a r

Cautions Design and Compliance Notes Design Notice Energy Rating Information The Energy Rating for this unit is based on an installation using an un-extended exhaust duct without adapters A or B (as shown in the Installation section of this manual).

Installation Choosing The Right Location Note About Fluorinated Gasses -This air-conditioning unit is a hermetically the amount, please refer to the relevant label on the unit itself. -Service, maintenance and repair of this unit must be technician. NOTE: All the illustrations in the manual are for explanation purpose only. Your machine may be slightly different. The actual shape shall prevail. The unit can be controlled by the unit control panel alone or with the remote controller. Your installation location should meet the following requirements: -Make sure that you install your unit on an even surface to minimize noise and vibration. -The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible. -The unit should be located at least 30cm (12 ) from the nearest wall to ensure proper air conditioning. -DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause damage to the unit.

Installation Tools Needed -Medium Philips screwdriver; -Tape measure or ruler; -Knife or scissors; -Saw (optional, to shorten window adaptor for narrow windows) Accessories be shortened for smaller windows. Part Unit Adaptor Description Exhaust Hose Window Slider Adaptor Bolt Window Slider A Window Slider B Foam Seal A (Adhesive) Foam Seal B (Adhesive) Foam Seal C (Non-adhesive) Security Bracket and 2 Screws Drain Hose Drain Hose Adaptor (for Heating models only) Remote Controller (2 AAA batteries, not included) Quantity 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 2 pc 2 pc 1 pc 1 set 1 pc 1 pc 1 pc Window Installation Kit Step One: Preparing the Exhaust Hose assembly Press window slider adaptor and unit adaptor onto the exhaust hose. Clips on the adaptors will automatically clamp onto the exhaust hose. Step Two: Install the Exhaust hose assembly to the Unit Align the hooks on the unit adaptor to the hole seat of the air outlet (located on the back of the unit). Insert adaptor and slide hose assembly downwards into the groove. Hook adaptor Exhaust hose Unit adaptor Hole Seat Lower groove Window slider adaptor Window slider A Exhaust hose assembly Make sure the adaptor is inserted into the lower groove of the air outlet. Bolt Window slider B

Installation Type 1: Hung Window Installation Type 2: Sliding Window Installation

Installation.

Operation Swing button Used to initiate the Auto swing feature. If auto-swing is in function, press the button again to stop the louver at desired angel. Timer button Used to initiate the AUTO ON (start time) and AUTO OFF (stop time) buttons. The corresponding timer indictor light will illuminate. Mode button Selects the appropriate operating mode. Each press of the button will select mode in the following sequence: AUTO, COOL, DRY, FAN and HEAT (heating models only). The corresponding mode indicator will illuminate. setting in 1 C/1 F increments. Adjustable range: NOTE: The control is capable of displaying temperature in Fahrenheit or Celsius. To convert from one to the other, press and hold the Up and Down buttons simultaneously for 3 seconds. Fan button Controls the fan speed. Press to select the fan speed in four steps: LOW, MED, HIGH and AUTO. The corresponding fan speed indicator will illuminate, except for AUTO speed. When AUTO is selecyed, all fan indicators are dark. Sleep button Used to initiate the SLEEP function. Power button Power switch, turns unit on/off. 9

Operation LED display Displays set temperature, in either C or F. Displays auto-timer settings (if any) When unit is in DRY or FAN modes, displays currentroom temperature. Displays error codes and protection codes: E1: Room temperature sensor error E2: Evaporator temperature sensor error E3: Condenser temperature sensor error E4: Display panel communication error P1: Bottom tray is full. Connect the drain hose to drain and empty the bottom tray. Note: When one of the above malfunction occurs, turn offthe unit and check for any obstructions. Restart the unit,if the error persists, turn off unit and unplug power cord. Contact Sunpentown customer service at 800-330-0388. CAUTION! If unit is stopped or powered off unexpectedly, there will be a 3-minute delay before unit will start up again. This is to protect the compressor. Unit will automatically resume after 3 minutes. Operating Temperature Range Mode Cool 17-35 C (62-95 F) Dry Heat (heating models only) Temperature Range 13-35 C (55-95 F) 5-30 C (41-86 F) Operation Instructions COOL operation - Press the MODE button until COOL indicator lights up. - Press the + or - button to set desired room temperature. Temperature range is between 62 F~86 F (17 C~30 C). - Press the FAN button to choose desired fan speed. HEAT operation ((heating models only) - Press the MODE button until HEAT indicator lights up. - Press the + or - button to set desired room temperature. Temperature range is between 62 F~86 F (17 C~30 C). - Press the FAN button to choose desired fan speed. FAN operation - Press the MODE button until FAN indicator illuminates. - Press the FAN button to select desired fan speed. - The temperature cannot be adjusted. - Exhaust hose connection is not needed. DRY (dehumidify) operation - Press the MODE button until the DRY indicator light illuminates. - Under this mode, fan speed cannot be selected and temperature cannot be set. The fan operates at LOW. - Keep windows and doors closed for the best dehumidifying effect.. AUTO operation - When the unit is set in AUTO mode, it will automatically select cooling or fan mode, depending on set temperature and ambient room temperature. - The air conditioner will operate in the appropriate mode based on the set temperature. - Under AUTO mode, fan speed cannot be set.

Operation

Operation Water drainage Remove the upper drain plug Continuous drain hose " universal female mender) to a 3/4" hose (not included, purchase locally). Connect to spout. For models without the drain connector, just attach drain hose to spout. - Position the open end directly over drain area. delivery lift <1.8m drain hose adaptor drain hose adaptor X Remove the lower drain plug Continuous drain hose drain hose adaptor " universal female mendor) to a 3/4" hose (not included, purchase locally). Connect to spout. - Position the open end directly over drain area. - The continuous drain for Heat mode has a built-in pump, maximum height for the drain hose is 5 feet. "P1". At this time, the compressor will immediately stop but fan will continue to operate. - Place a collection pan underneath the bottom tray drain spout or carefully move the unit to a drain location. - Remove the bottom drain plug and water will begin to drain out. - Replace the drain plug and restart unit. P1 indicator should disappear.

Maintenance Safety Precautions -Always unplug the unit before cleaning or servicing. -DO NOT wash the unit under running water. Doing so causes electrical danger. -DO NOT operate the machine if the power cord is damaged. Contact Sunpentown or a qualified electrician. Clean the Air Filter Clean the filters at least once every two weeks to prevent inferior fan operation due to dust accumulation. - Clean filters by washing in warm water (40 C/104 F) with a neutral detergent. - Rinse clean and allow to dry in a shady area. Do not place under direct sunlight. Upper filter (take out) Clean the Unit Use a lint free cloth soaked with neutral detergent to clean the housing. Finished by a dry clean cloth. Storage -Drain the unit s water collection tray according to the instructions in the previous section. -Run the appliance on FAN mode for 12 hours in a warm room to dry the interior and prevent mold. -Turn off the appliance and unplug power source. -Remove the batteries from the remote control. Store unit in a cool, dark place. Exposure to direct sunlight or extreme heat can shorten the life span of the unit. Remove the screw,then take the lower filter out. Remove the air filter Maintenance Tips -The water collection tray should be drained immediately after P1 error occurs, and before storage to prevent mold. -In households with animals, you will have to periodically animal hair.

Trouble Shooting Please check the machine according to the following before asking for maintenance: Problem Unit does not turn on when pressing ON/OFF button Unit does not cool well The unit is noisy and vibrates too much Possible Cause P1 Error Code In COOL mode: room temperature is lower than the set temperature The air filter is blocked with dust or animal hair Exhaust hose is not connected or is blocked The unit is low on refrigerant Temperature setting is too high The windows and doors in the room are open The room area is too large There are heat sources inside the room The ground is not level The air filter is blocked with dust or animal hair Troubleshooting The Water Collection Tray is full. Turn off the unit, drain the water from the Water Collection Tray and restart the unit. Reset the temperature Turn off the unit and clean the filter according to instructions Turn off the unit, disconnect the hose, check for blockage and reconnect the hose Call a service technician to inspect the unit and top off refrigerant Decrease the set temperature Make sure all windows and doors are closed Double-check the cooling area Remove the heat sources if possible Place the unit on a flat, level surface Turn off the unit and clean the filter according to instructions The unit makes a gurgling sound This sound is caused by the flow of refrigerant inside the unit This is normal

USING THE REMOTE CONTROLLER MODE FAN SLEEP SWING SHORT CUT TIMER ON TIMER OFF LED

HEAT (heating model only) NOTE: Please do not select HEAT mode if your model is cooling only type. Press to turn the LED display on the unit on or off.

Button designs on your unit may differ slightly from the example shown. When there are wide differences between Remote controller illustration and USER'S MANUAL on function description,the description of USER'S MANUAL shall prevail. Inserting and Replacing Batteries The remote controller is powered by two AAA batteries (not included). The batteries are housed in the back of the remote, protected by a cover. Place batteries in the remote control before use. 1. Press down on the cover and slide it outwards to remove. 2. Insert batteries, paying attention to match the (+) and (-) ends of the batteries with the symbols inside the battery compartment. 3. Slide the battery cover back into place. For optimum product performance: Do not mix old and new batteries, or batteries of different types. Remove batteries if the remote will not be used for more than 2 months TIPS FOR USING REMOTE CONTROL The remote control must be used within 8 meters of the unit. The unit will beep when remote signal is received. Curtains, doors, other barriers and direct sunlight can interfere with the infrared signal receiver.

(Heating models only)

How To Use The Basic Functions The operating temperature range for the unit is 17 C-30 C (62 F-86 F). You can increase or decrease the set temperature in 1 C(1 F) increments COOL OPERATION 1. Press the MODE button to select COOL 2. Set your desired temperature using the Temp Up/Down button. 3. Press the FAN button to select the fan speed: AUTO, LOW, MED or HIGH. 4. Press the ON/OFF button to start the 3 1 ON/OFF MODE TEMP SHORT CUT TIMER ON 2 4 1 3 ON/OFF MODE TEMP FAN SLEEP SWING SHORT CUT TIMER ON TIMER OFF LED 2 FAN TIMER OFF SLEEP SWING AUTO OPERATION In AUTO mode, the unit will automatically select COOL, FAN, HEAT (heating models only), or DRY mode based on the set temperature 1. Press the MODE button to select Auto mode. 2. Set your desired temperature using the Temp Up/Down button. 3. Press the ON/OFF button to start the unit. NOTE: FAN SPEED can t be set in Auto mode. LED HEAT OPERATION 1. Press the MODE button to select HEAT. 2. Set desired temperature using the Temp Up/Down button. 3. Press the FAN button to select the fan speed: AUTO, LOW, MED,or HIGH. 4. Press the ON/OFF button to start. NOTE: As outdoor temperature drops,the performance of your unit's HEATfunction may be affected. In such instances, it is recommended to use this unit in conjunction with other heating appliance. NOTE: Heat mode is for cooling & heating models only. 19 4 1 3 ON/OFF MODE TEMP FAN SLEEP SWING SHORT CUT TIMER ON TIMER OFF LED 2

DRY OPERATION FAN OPERATION 1. Press the MODE button to select DRY 1. Press the MODE button to select FAN mode. mode. 2. Press FAN button to select the fan speed: 2. Set your desired temperature using the AUTO, LOW, MED or HIGH. Temp Up/Down button. 3. Press the ON/OFF button to start the unit. 3. Press the ON/OFF button to start the unit. NOTE: Temperature cannot be set in FAN NOTE: FAN SPEED can not be changed in mode. As a result, LCD screen will not DRY mode. display temperature.

MODE Your air conditioning unit has two timer-related functions: TIMER ON: Set the amount of time after which the unit will automatically turn on. TIMER OFF: Set the amount of time after which the unit will automatically turn off. TIMER ON function: Sets amount of time for unit to turn on, such as when you will return home. Press the TIMER ON button. By default, the last set time and "h" (hour) will appear on display. Press the TIMER ON button again and repeatedly to set desired time. When desired time is reached, release button and wait 2 seconds for TIMER ON to activate. Display will return to displaying temperature. EXAMPLE: if you wish to set TIMER ON for 2.5 hours, press button once to initiate and 5 more times for 2.5 hours. "2.5h" will display on the screen and unit will turn on after 2.5 hours. 1 2 3 4 1sec x5 2sec TIMER ON TIMER ON ON/OFF FAN SHORT CUT TEMP TIMER ON S L EEP TIMER OF F TIMER OFF function: Sets amount of time for unit to turn off, such as when you pan to leave. Press the TIMER OFF button. By default, the last set time and "h" will appear on display. Press the TIMER OFF button again and repeatedly to set desired time. When the desired time is reached, release button and wait 2 seconds for TIMER OFF to activate. Display will return to displaying temperature. EXAMPLE: if you wish to turn unit off after 5 hours. Press TIMER OFF button once to initiate and press 10more times to set 5.0 hours. "5.0h" will display on thescreen and unit will turn off after 5 hours. 1 2 TIMER OFF TIMER OFF x10 3 4 1sec MODE FAN S L EEP ON/OFF TEMP SHORT CUT TIMER ON TIMER OFF 2sec 21 NOTE: When setting TIMER ON or TIMER OFF functions, each press of button increases the set time by 30-minutes, up to 10 hours. Then by 1-hour increments, up to 24 hours. Timer will revert to zero after 24 hours. Either timer function can be turned off by setting time to "0.0h".

MODE MODE CUT Setting combined timers: TIMER ON and TIMER OFF at the same Keep in mind that the time periods you set for both functions refer to hours after the current time. For example, say that the current time is 1:00 PM, and you want the unit to turn on automatically at 7:00 PM (which is 6 hours from current time); operate for 2 hours, then automatically turn off at 9:00 PM (which is 8 hours from current time). Do the following: 1 2 X12 3 4 sec TIMER ON TIMER ON ON/OFF SHORT TEMP CUT TIMER ON 5 6 X16 7 8 sec TIMER OFF TIMER OFF ON/OFF SHORT TEMP TIMER ON

F after 30 minutes; and by another 1 C/1 F after additional 30 minutes. New temperature will be maintained for 7 hours then unit returns to originally set temperature. This ends the SLEEP function.