VADA - Rain2Main Automatic Rainwater Controller

Similar documents
V80-H Multistage Pump Instruction Manual

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

DIRTY WATER SUBMERSIBLE PUMP

DIRTY WATER SUBMERSIBLE PUMP KIT

Classic Heater Pool Controller

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

CONSTANT PRESSURE PUMP

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

POTABLE PRESSURE PUMP

CLEAN WATER SUBMERSIBLE PUMP

SUBMERSIBLE WATER PUMP

DIRTY WATER SUBMERSIBLE PUMP

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

2 IN 1 SUBMERSIBLE PUMP

CONSTANT PRESSURE PUMP

INTRODUCTION SPECIFICATIONS. Pump Flow Curve

CLEAN WATER SUBMERSIBLE WATER PUMP

SCHWAN INSTALLATION GUIDE

Classic Heater Spa Pool Controller

SUBMERSIBLE WATER PUMPS

BRITA. Water Filter & Chiller II. Chilled water filter. Instruction Booklet WF6100

KADO LUX LED EXHAUST FAN 200

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual

Brita. Water Filter & Chiller. Instruction Booklet WF6000. Please read these instructions carefully and retain for future reference.

Installation and Operating Instructions for Davey BF Series Pressure Booster Systems with Flow Switch Control

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

PJ130S High Pressure Cleaner

Installation and Operating Instructions for Microlene Underbench System

INSTALLATION INSTRUCTIONS

AquaReef Cube. Inspiring Excellence in Fish Keeping!

Flomate Mains Boost Pump Installation & Maintenance Instructions

Installation Information User Manual

OPERATING AND INSTALLATION MANUAL

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

Installation and Operation Guide

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

OPERATING AND INSTALLATION MANUAL

INSTALLATION GUIDE NZ AU D

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

Rules for Safe Operation

SAFETY AND OPERATING MANUAL. All-in-One blower/ vac/mulcher WG502E

APW-VAP-150P High Pressure Cleaner Operator Manual

TH100 Three in One Instant Hot Water Tap

Operating and assembly manual: Electric instantaneous flow heater Admiral

Super Super Super Works Super Super Works

OPERATION & MAINTENANCE INSTRUCTIONS

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Instructions for installation and use English. More documents on: H B /09

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Installation and Operation Guide

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

Convection Panel Heater

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

General Care and Safety Guide

CENTRA-COIL QUALITY HOT WATER SERVICE

Sunbeam Tower Fan with Night Mode

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

INSTALLATION GUIDE NZ AU C

SELF-PRIMING JET PUMPS

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Installation & Operating Instructions

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

The Professional s Choice

Flow Factor ~

INSTALLATION GUIDE NZ AU E

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

Convection Panel Heater

WC2 & WC3 Installation & Maintenance Instructions

Aquience 1200/1500 R

Installation & Operating Instructions

professional pressure washer

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

INSTALLATION GUIDE NZ AU

AC-12200E Portable Air Conditioner

PANTHER. Condensate removal pump Installation and operating guide

OWNER S MANUAL & WARRANTY

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

ion Genesis Pump Controller

OWNER S MANUAL. SilentFlo. Pool Pump. For the Installation, Operation and Service of

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

Next Generation Corona Discharge Installation & Operation Manual

Moisture inside the drum is due to final testing.

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

MODULAR AUTOMATIC GRANULAR ICE FLAKER

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

Owners Manual for the Rainmaster Water Recycling System

Transcription:

PRODUCT OVERVIEW / APPLICATION The Vada Rain2Main is designed to select between stored rainwater (when available) and mains supply water, and send this water to your toilet cistern, washing machine, garden and other non-potable household water applications. It features automatic pump control to minimise the use of electricity while saving water. When your tank is empty, the Rain2Main seamlessly switches to mains water supply so that there is no interruption of water to your toilet cistern or washing machine. Do not use the Rain2Main for liquids other than clean water. TECHNICAL DETAILS Mains Water supply inlet 1 BSP Female Thread Pump Connection 1 BSP Female Thread Water Outlet Connection 1 BSP Female Thread Protective Rating IP44 Min Mains Pressure 100 kpa Max Mains Pressure 1000 kpa Water Temp Range 1 C - 40 C Ambient Temp Range 1 C - 40 C Rated Supply Voltage 230-240Vac Max Electrical Load 10A Power Consumption (Mains) 1W Power Consumption (Tank) 18W Minimum Flow Rate 2 L/min INSTALLATION INSTRUCTIONS The operator must be provided with this owner s manual. This must be read before instlalation and followed during installation. These instructions are a guide only. Users not familiar with the installation and maintenance of electrical and pumping equipment should seek advice from people with experience in pump installation and operation. Rain2Main is designed to be used with clean water in a residential application. Do not use with alternative fluids, specifically abrasive, corrosive or explosive fluids. This appliacne is not intended for use by persons (incl children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless have been given supervision or instruction concerning the use of the appliance. Children should be supervised to ensure they do not play with Rain2Main. WARRANTY & AFTER SALES SERVICE You have purchased a quality product from Reece Australia. This product is covered by a 24 month warranty. This warranty covers faults in the product construction, material and assembly. Faulty products will be repaired or exchanged free of charge. Faulty items become our property. This warranty does not include faults caused by Unsuitable or improper use Incorrect installation Normal wear and tear Inadequate or complete lack of maintenance Chemical, electrochemical or electrical influences To the maximum extent permitted by law, Reece excludes all warranties other than those set out above. In the event of a warranty claim, we will replace or repair defective products, or pay for the cost of having defective products repaired or replaced, but will not be liable for any injury to any person, damage to any property, any indirect or consequential loss, or in any other respect. For after sales service, call 1800 080 055.

INSTALLATION Freezing conditions will damage the unit, as water expands as it freezes. Ensure that the Rain2Main is located so that it is not prone to freezing, or ensure that the product is disconnected and dried of water during cold conditions. Rain2Main is electrically connected. Ensure that it is isolated from electrical supply during installation and any subsequent service work. Do not install or operate Rain2Main in an explosive environment or near combustible matter. Brace inlet and outlet connections while fitting Rain2Main. Any movement of connections may disturb internal seals and cause leakage. PREPARATION FOR INSTALLATION Read these instructions first. Inspect Rain2Main for shipping damage. Report any damage to your Reece store of purchase. If the incoming mains pressure to your property is greater than the specified 1000 kpa, please fit a pressure reduction valve of appropriate capacity upstream of Rain2Main. This pressure reduction valve must bring the pressure to below the rated value of 1000 kpa. A recommended pressure is 500-750 kpa. Fitting this type of device to your entire household will extend the life of other appliances such as washing machines, hot water service and dishwashers. Fittings and Accessories Ensure that you have all required fittings and accessories prior to installing Rain2Main. Surface Pumps For installation we recommend the following items: - threadseal tape - 1 BSP male to chosen pipe type connector (x2) Submersible Pumps Mounting Rain2Main on a wall is made easy with the optional wall mounting kit. In addition, flexible hose (at least 25mm diameter), barbed hose connectors and hose clamps may also be required. Protection Warranty of this Rain2Main is void unless it is operated in accordance with this owner s manual. The pump and Rain2Main should be housed in a weather-proof, well ventilated enclosure, to protect from the weather, flooding, chemicals, dust, vermin, insects, etc. UNDERGROUND TANKS In the situation where an above-ground pump (jet pump or horizontal multistage) is being used with a Vada Rain2Main to connect to an underground tank, a float switch must be used. A float switch is not required for above ground tanks or for submersible pumps connected to underground tanks. Ensure installation is in accordance with AS/NZS 3500.1 - Plumbing and Drainage - Water Services. INSTALLATION RECOMMENDATIONS 1. The Vada Rain2Main comes with 2 mesh inline filters. These filters should be correctly inserted on the mains water input and pump input of the Rain2Main. 2. The recommended height of the tank outlet from the base of the tank be set at 100mm. 3. A recommended minimum distance of 100mm of straight pipe at the Rain2Main mains water inlet. 4. Clean water is essential for the reliable operation of your Rain2Main system. We recommend the installation of first flush diverters and leaf guards on your water collection system. Mounting The pump and Rain2Main must be mounted on a solid, level, vibrationfree surface. The Rain2Main can be mounted in one of two ways: 1. Mount directly to the top of the pump with surface accessory kit. 2. Mount remote from the pump with wall bracket.

INSTALLATION Connecting the Rain2Main to the Pump Using the Union Kit (Where Supplied) 1. Wrap a sufficient amount of thread seal tape around both ends of the 1 Nipple. 2. Connect one end of the nipple into the pump discharge, threading it until it is watertight. (DO NOT OVERTIGHTEN) 3. Connect the 1 Female end of the complete barrel union onto the protruding end of the 1 Nipple until it is watertight (DO NOT OVERTIGHTEN) 4. Wrap a reasonable amount of thread seal tape around the 1 end of the union nipple. Thread it into the base of the Rain2Main until watertight (DO NOT OVERTIGHTEN). If you are unable to screw the Rain2Main on top due to space limitations, unscrew the barrel union nut releasing the nipple from the union, then thread the nipple into the Rain2Main (Make sure the Union nut remains on the nipple). Rejoin the union to complete the connection. Mains Inlet Connection Rain2Main has a 1 BSP Female fitting to connect the incoming mains supply water. This end is marked with an arrow pointing into the unit (showing water flow direction). Brace this fitting to prevent movement while connecting to the mains supply. Any movement of this fitting may disturb internal seals and cause leakage. Water Outlet Connection Rain2Main has a 1 BSP Female fitting to connect to household plumbing for uses such as filling toilet cisterns, the washing machine, and garden taps. This end is marked with an arrow pointing out of the unit (showing water flow direction). Brace this fitting to prevent movement while connecting. Any movement of this fitting may disturb internal seals and cause leakage. Pipe Marking In accordance with AS/NZS 3500.1:2003, pipes and outlets connected to Rain2Main must be marked as follows: Outlets that are connected to your Rain2Main must be marked with the wording RAINWATER. The piping system connected to Rain2Main must be clearly marked at 1m spacings with the wording RAINWATER Rain2Main Electrical Connection To avoid dangerous or fatal electrical shock, turn OFF power to the Rain2Main before working on any electrical connections. The supply voltage for the Rain2Main must be within the stated parameters. If the power supply cord or pump interconnection cord is damaged, it must be replaced by a qualified person or return to place of purchase in order to avoid hazard. Before connecting Rain2Main to an electrical power supply, connect the pump to the Rain2Main using the provided IEC appliance connectors on the end of the interconnection cords. Ensuring there are no traces of water on the connectors, push them firmly into each other to ensure splash proof protection. This connection should only be separated for servicing purposes, and only after the power supply of the Rain2Main is removed either through an isolation switch or by unplugging. Rain2Main is supplied with a standard Australian 10A plug and cord, and connection to the power supply is a matter of inserting the plug into the suitable socket outlet. If local authorities require the Rain2Main and pump to be hard wired, the electrical connection must be done by a qualified electrician with pump knowledge according to the National Wiring rules (AS/NZS 3000) and/or any local council requirements. We recommend to connect Rain2Main to a socket outlet protected by a Residual Current Device - RCD (Also known as an Earth Leakage Circuit Breaker ELCB) with a rated tripping current not exceeding 30mA. Contact a qualified electrician if you cannot verify that the socket outlet is protected by RCD. RCD tripping indicates an electrical problem. If the RCD trips and will not reset have a qualified electrician inspect and repair electrical system. Do not apply power to the system until the pump has been primed and the water level in the tank is above pump suction inlet. Refer to pump manual for further installation details.

Operation Commissioning Put a small amount of water in the tank (just above the level of the pump inlet). Prime the pump if surface mounted. Turn power to the rain2main on. Open a tap on the outlet side of the Rain2Main (or have someone flush the toilet). The pump will start. Turn off the tap, and the pump will stop (after a run-on period of 15 seconds). Temporarily close the valve between the tank and pump inlet, or drain the tank to below the pump inlet. This indicates to the Rain2Main that there is no water in the tank, and it will switch to mains supply operation after 5 failed attempts to draw water from the tank. Again, open the tap or flush the toilet. Mains supply water will fill the cistern. Close the tap, open the tank valve and restart the Rain2main. If there are any variations to these outcomes, please see the troubleshooting section. MAINS SUPPLY MODE Rain2Main has a mechanism to prevent the pump from running with no water. If the tank is empty or there is a blockage or partial blockage somewhere in the system the following process will occur: 1. If Rain2Main is supplying water and is operating normally, it will activate the pump to supply rain water. 2. If no rain water is delivered from the tank within 30 seconds, Rain2Main will switch to supplying mains water. 3. After 6 seconds if no rainwater has passed through the system, Rain2Main will divert to mains water. 4. If no water is delivered from the tank it will repeat step 2 and step 3 four times. If there is still no water delivered, Rain2Main will switch to mains supply mode. 5. The LED on the Rain2Main will flash red to warn that abnormal conditions exist. It also locks out the pump from further operation to protect the pump from dry running, and to ensure that the house has continuous mains water supply. 6. Automatic Lockout Reset Feature Event 1st lockout 2nd lockout 3rd lockout 4th lockout 5th lockout Reset Time 10 minutes 1 hour 6 hours 24 hours 160 hours (Rain2Main will check for tank water every week following, until water is available in the tank) This feature can be over ridden by switching the unit off for 10 seconds. General Operation Your Rain2Main operates entirely automatically without intervention. If electrical supply is cut in your neighbourhood, Rain2Main will automatically revert to mains supply water, as there is no power to drive the pump. When power resumes, Rain2Main will continue to operate normally. If town supply water is shut off in your area, Rain2Main might not be able to detect water demand in the household (e.g. if the toilet cistern needs refilling). By pressing the manual override button, you can override normal control and start the pump to supply water out of the rain water tank. SERVICE AND MAINTENANCE Rain2Main is a warm, dry environment for hibernating insects. These can cause electrical malfunction. Ensure that your property is vermin free. Rain2Main is electrically connected. Ensure that it is isolated from electrical supply during installation and any subsequent service work. Rain2Main should only be serviced by a Pentair Water service agent. Rain2Main Service To reset from loss of prime mode: Before removing Rain2Main for service: a) Turn off power for 10 seconds 1. Switch off power to Rain2Main before proceeding. b) Turn power supply back on 2. Close shut off valves at inlet, outlet and water tank gate valve. c) Reprime the pump. Check for blockages in suction line. 3. Carefully release all pressure from the pump and piping system. 4. Never tighten or loosen fittings while the pump is operating. Rain2Main should resume normal operation.

TROUBLE SHOOTING GUIDE Symptom Cause Remedy No water is being delivered from pump Water tank is empty Check tank level, wait for rain if empty No water is being delivered from pump: Rain2Main has gone into mains supply mode No power at outlet Pump has overheated Mesh filter is blocked Pump is worn Valve on or between tank & Rain2Main inlet is closed. Pump is not primed Mesh filter is blocked Tank is empty Tank was empty and Rain2Main has not yet detected water Check power supply, circuit breakers and plug Allow pump to cool Switch power off. Isolate water, remove pump barrel union, inspect/clean/replace filter. Have pump serviced by service agent or other qualified person Open gate valve and prime pump. Reset Rain2Main Prime pump and reset Rain2Main Switch power off. Isolate water, remove pump barrel union, inspect/clean/replace filter. Wait for tank to fill Turn off Rain2Main. Wait for 10 seconds. Turn Rain2Main on again. No water supply at all Mains water valve is closed Check mains water isolation valve is open Blockage in system Incoming mains pressure is greater than 1000 kpa Check mains water and tank water piping for obstructions Fit a pressure reduction valve to reduce incoming mains pressure Poor water pressure through pump Mesh filter is blocked Switch power off. Isolate water, remove pump barrel union, inspect/clean/replace filter. Worn pump Pump is too small for the application Have pump serviced by service agent or other qualified person Have local Reece store recommend larger pump Pump continually runs Air lock in system Bleed air from system. Activate appliances / outlets sequentially from the nearest to the furthest outlet. Repeat if necessary. If problem persists, contact your local store. LED Indicator Rain2Main Floatless Rain2Main with Float Green light flashes once every second. Stand-by. Stand-by, tank full Amber light flashes once every second. Fault, jack plug disconnected. Stand-by, tank empty Green light on solid (amber light flashes once per second) Pump on, water flow from the tank. Pump on, water flow from the tank. Red light on solid. Fault, jack plug disconnected, flow from mains. Tank empty, flow from mains. Red light flashing. Tank empty, flow from mains. Loss of prime, flow from mains.