Similar documents
Model Series Series

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

Models Series Series

Models Series Series

Automatic Water System Pump SERIES

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

SHURFLO INDUSTRIAL PUMP TECHNOLOGIES

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

TABLE 1 Electrical Specifications

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

TABLE 1 Electrical Specifications. Phase

Instruction Manual for Electric Marine Toilets LT-0E and LT-1E

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

PumpAgents.com - Click here for Pricing/Ordering PAR MAX3 Models Series 3.4GPM/12.8LPM

Installation and Owners manual

ENGLISH. Dometic Environmental Corporation. Rev L-2484

Fully Automatic Water Softeners

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

Installation Instructions

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

Model K 280 M Part No

LC Series - Light Commercial Pump Station Installation and Operation Manual

MARINE SELF-CONTAINED DIRECT EXPANSION AIR CONDITIONING SYSTEMS

Model K 5800 G Part No

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Model K 330 M Part No

Model K 240 plus Part No

Model K205 M Plus Part No

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Page 1 of 18. Part# /5/2013

Models: GW/R-T GW/R-2-T GW/R-3-T

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

Model K 3000 G Part No

AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

INSTANT-FLOW C-MICRO WATER HEATER

Model K 4400 G Part No High Pressure Washer

Model 53 Macerator Pump Installation, Operation, Repair Manual

Model Series. Model Series QUIET - FLUSH ELECTRIC TOILET CONVERSION FEATURES SPECIFICATIONS OPERATION

Jabsco Marine Toilets SIMPLY RELIABLE SOLUTIONS FOR EVERY BOAT AND BUDGET

Model LF-310 Air Operated

INSTANT-FLOW C-MICRO WATER HEATER

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Model K 520 M Part No

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

Installation and Owners manual

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

LITTLE BLASTER LARRY HESS AND ASSOCIATES, INC. BLAST-IT-ALL P.O. BOX 1615 SALISBURY, NC WITH DUST COLLECTOR

K 3.97 M. Specifications or visit our website: In USA call: Part No

ESTEAM CLEANING SYSTEMS OWNER S MANUAL

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

Model HD 3501 Part No High Pressure Washer Operator Manual

CR330 Owner s Manual

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

IMPORTANT SAFETY INFORMATION READ ALL...

Cool IR. Model C104 - Cooling System. Instruction Manual

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

INSTALLATION INSTRUCTIONS

User Manual MYTEE LITE. REV. 2/15/18 Carpet & Upholstery Spotter Stowe Dr. Poway, CA P: (858) F: (858)

AUTOTROL 360 MANUAL & 361 SEMI-AUTOMATIC FILTER VALVES SERVICE MANUAL

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

COBRA -300H EXTRACTOR

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

High Pressure Washer Operator Manual. Specifications Model HD 2700 DH/DB

DISPENSING TROUBLESHOOTING INDEX

Eccotemp L5 and L10 Comprehensive Troubleshooting Guide

PRO SERIES IMPORTANT SAFETY INFORMATION

Installation Instructions Air Pump

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

G 2000 ET. English 2 Español 15 Français 30! /06

Installation Manual CARBONATOR With Plain-Water Booster

K Specifications. Max. Water Volume

CWS AIR-CONDITIONERS

INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Model Series QUIET - FLUSH ELECTRIC TOILET CONVERSION FEATURES. Model Series INSTALLATION SPECIFICATIONS VARIATIONS AVAILABLE OPERATION

COBRA -H EXTRACTOR 120V

Non-RTD Hot Melt Hose Replacement

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

SAN JUAN FRESH WATER COOLING SYSTEMS

MERMAID CONDENSATOR INSTALLATION MAINTENANCE & TROUBLESHOOTING GUIDELINES

12 Impeller Replacement

A HEATER KIT With Diesel Engine Connection Fittings

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

SYSTEMS for CATALYTIC FILTERS

Transcription:

SHURFLO BLASTER II MARINE WASHDOWN PUMP PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 8-11-A07 8-11-E07 APPLICATION: Marine fresh or salt water wash-down installation. This pump may be used for general water transfer. PUMP DESIGN: Type: Chamber Diaphragm pump Ports: ½ -1 NPSM-Male Liquid: 10 F [5 C] Max Dry-Prime: 6 feet [1.8 M] Run Dry: Yes Inlet Pressure: 0 PSI Max. [.06 Bar] Aftermarket model includes: - Pistol grip plastic spray nozzle - Fittings: swivel straight adapter ½-1 NPT (hex-wing nut) x ¾ barb (Qty. ) - Fitting: swivel straight adapter ½-1 NPT (hex-wing nut) x ¾ NHR (Male) (Qty. 1) ELECTRICAL: Motor: Protection: Leads: Fuse: Control: 1V DC Permanent Magnet, Intermittent Duty. Thermal Overload, Automatic Restart 1 AWG, 1 ¾ [7 cm] Red +, 15 [8 cm] Black 10 Amp Recommended Shut-Off 5 PSI [.1 Bar] ± PSI [0.1 Bar] Re-start 0 PSI [.0 Bar] ± PSI [0.1 Bar] REPAIR KITS MATERIALS OF CONSTRUCTION: Housings: Polypro Valves/Seals: EPDM Diaphragm: Santoprene Hardware: Stainless Steel AGENCY APPROVALS: Ignition Protection 886, CE, IMCI Certified SHIPPING INFORMATION: Approx. Net Weight: 5. lbs. [. Kg] ea. Carton Qty.: 6 Approx. Carton Weight: 1. lbs. [ 1.1 Kg] Approx. Carton Size: L X 18 W X 6 H [61cm x 6cm x 15cm] Retail (individual) box: 11 L X 6 W X 5 H [8cm x 15cm x 1cm] Number Description Part Number 1 Upper Assembly 9-800-1 Valve Assembly 9-800-01 Drive Assembly 9-800-15 Motor/Gasket 9-71-00-07 1,, Pump Head 9-800-17 Not Shown Check Valve 9-800-0 Page -1

RELATED DOCUMENTS: Catalog: MS-00-10 App Guide Sheet : MS-00-005 Installation Manual: 911-107 Aftermarket Warranty: 911-105 TYPICAL PERFORMANCE AT 1V PRESSURE FLOW CURRENT BAR PSI GPM LPM AMPS 0 0.7 1.0.0 0.7 10.7 10..9 1. 0. 8.7.9.1 0.0 7.5 5.8.8 0 1.8 6.8 6. Flow (GPM).5.5 1.5 1 0.5 0 8-11-A07 0 10 0 0 0 Pressure (PSI) 7 6 5 1 0 Current (Amps) Flow Amps DIMENSIONS: FLOW MANAGEMENT SOLUTIONS 55 Harbor Gateway South, Suite 10, Costa Mesa, CA 966, (800) 85-18 www.shurflo.com All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. Page - 8-11-A07 [E07] Rev. 05/1 01 Pentair, Inc. All Rights Reserved.

SHURFLO BLASTER II.5 GPM MARINE WASH DOWN PUMP MODEL SERIES 8 SHURFLO BLaSTER II Designed for the toughest wash down applications. SHURFLO s BLASTER II wash down pump design was created with unique over-molded single-piece diaphragm, assuring long life and top performance in all deck wash down plumbing systems. Designed as the next legendary pump to exceed the expectations of our customers, the BLASTER II pumps are designed for the toughest marine wash down applications. SHURFLO s quality reputation has been built on the reliability and dependability of every pump we build. The BLASTER II wash down automatic demand pumps are quiet, thermally protected and can run dry without damage. FEaTURES independent chambers Co-Molded diaphragm Adjustable pressure switch Self-priming up to 6 feet Sealed switch Sealed motor Corrosion resistance electro coated motor Thermally protected Ignition protected, CE INSTaLLaTION TIPS Properly sized plumbing Properly sized wiring Mount in a dry location that allows easy access if maintenance is required Mount higher than the outside water level, the pump is capable of 6ft. vertical prime above water line Use proper fuse size Install strainer on pump inlet Minimize plumbing elbows and valves Flexible high-pressure hose on inlet and outlet OPERaTION TIPS Pump is design for intermittent operation only Turn off power to the pump when boat is unattended Maintain your strainer clean for ultimate pump performance Pump will perform at best when proper voltage is provided application Marine 1V DC or V DC systems see pump label for rated voltage Wash Down applications General water transfer FILTRaTION & PROCESS 911-107 REV. A 1

SHURFLO s BLASTER II wash down pump design was created with unique over-molded single-piece diaphragm, assuring long life and top performance in all deck wash down plumbing systems. Designed as the next legendary pump to exceed the expectations of our customers, the BLASTER II pumps are designed for the toughest marine wash down applications. SHURFLO s quality reputation has been built on the reliability and dependability of every pump we build. The BLASTER II wash down automatic demand pumps are quiet, thermally protected and can run dry without damage. DUTY CYCLE See pump label for fuse size SHURFLO raw water strainer Ignition protected U/L marine switch Inlet Red SHURFLO spray nozzle Black Outlet Battery SHURFLO Pump 6 ft. max [1.8 m] Verical lift from outside water lavel Use flexible high pressure tubing to pump inlet port from thru-hull fitting, strainer, and pump. Tubing should be rated for below water line use. Wash down pumps are rated for intermittent duty ONLY, as they operate at higher than average pressures. Operating a wash down pump continuously for more than 0 minutes, within an hour period, is NOT recommended. Actual duty cycle is determined by amp draw and temperature. Through hull fitting Sea-cock valve MOUNTING Consider a DRY location that allows easy access if maintenance is required. The pump should not be located in an area of less than one cubic foot unless adequate ventilation is provided. Excessive heat may trigger the thermal protector and interrupt operation. When the temperature drops the thermal breaker will automatically reset and start operation. Mount higher than the water level. The pump is capable of a 6 ft. [1.8 Meter] vertical prime. The pump can be mounted in any position. If mounting the pump vertically, the pump head should be in the down position. Caution: Do not drive screws through the vessels hull. Use #8 stainless steel screws to fasten the pump. Choose a solid surface (bulkhead or stringer) that will not amplify pump sound. The mounting feet are intended to isolate the pump from the mounting surface; over-tighten, flattening or oversized screws will reduce the mounting ability to isolate vibration and noise. ELECTRICAL The pump should be on a dedicated (individual) circuit protected by the specified fuse on the motor label. A UL marine duty switch (ignition protected) rated for 15 amps or higher is recommended, and must interrupt current flow on the positive (+ red) lead. SHUT OFF POWER TO THE PUMP WHEN LEAVING THE BOAT UNAT- TENDED. Ft. [m] AWG [mm ] 0-0 [0-6] 1 [.5] 0-50 [6-15] 1 [] 50-70 [15-1] 10 [6] 70-100 [1-0] 8 [8] Minimum Wire Size for a 10% voltage drop on a 1VDC, 15 Amp Circuit. Length is the distance from the power source to pump and back to ground. NOTES To prevent cavitation, through hull fittings should be located at least 1 inches [0 mm] off the centerline of the water pick-up for the motor. The through hull fitting must have a seacock valve to shut-off in case of an emergency. Always use high quality non-corrosive fittings, valves and hardware to assure long-term reliability. Properly seal all pipe threads before the strainer to prevent unforeseen leaks. Never use Teflon tape or sealing compounds on SHURFLO pump threads or fittings. Sealer may enter the pump causing a failure not covered under warranty.

PLUMBING Installation of a strainer (such as SHURFLO 5 or 55 Series) is required to prevent debris from entering the pump. Avoid any sharp radius in the tubing that may kink over time. Route tubing away from any heat (exhaust manifolds etc.) and fasten securely. Inlet tubing (1/ [1.7 mm] I.D. minimum) from the seacock valve to the pumps should be rated for vacuum. If rigid pipe is utilized, SHURFLO recommends that the pump inlet port be plumbed with 1ft. [ Meter] of flexible tubing. Standard garden hose is not suitable as inlet tubing as it may collapse under vacuum, reducing water flow. The pump outlet port should not be connected to rigid (plastic) pipe. Normal oscillation of the pump may transmit through rigid plumbing causing noise and possibly loosen or cracking components. A 1ft. [ Meter] length of flexible high-pressure tubing is suggested. STRAINER / FILTRATION Installation of a 50-mesh minimum strainer, such as SHURFLO 5 or 55 Series, is recommended to prevent debris from entering the pump. Caution The strainer must be mounted above the outside water line to prevent water from siphoning during cleaning. Mount the strainer where it can be inspected and cleaned easily without closing the seacock valve. MAINTENANCE Normal pump maintenance is all that is needed: Checking and cleaning of the strainer, normal sanitizing and winterizing and occasionally checking all plumbing hardware and fittings for tightness. Lack of sanitizing is the number one reason for premature pump failure and poor performance over time. Lack of sanitizing will cause scale buildup on the diaphragm and valves, causing low flow and leak back (occasional pump cycling with spray nozzle closed). GENERAL SAFETY PRECAUTION When the vessel is not in use, the main power switch should be off and seacock valves should be CLOSED. However, if left afloat, the bilge pump should still have power. Never operate the engine or electrical equipment if fuel vapor is detected. Locate the source and vent properly. Electrical connections should be soldered and insulated to prevent shorts and corrosion. Wiring should be routed away from areas prone to water, heat and excess moisture. WINTERIZING Refer to the boat owner s manual for specific winterizing instructions. If water is allowed to freeze in the system, serious damage to the plumbing and pump may occur. Failures of this type will void the warranty. The best guarantee against damage is to completely drain the pump and perform the following: 1. Drain the water tank. If the tank doesn't have a drain valve, open the spray nozzle allowing the pump to operate until the tank is empty.. Allow the pump to purge the water from the plumbing, and then turn the pump "OFF.". Using a pan to catch the remaining water, remove the plumbing at the pump's inlet/outlet ports. Turn the pump ON, allowing it to operate until the water is expelled. Turn OFF the power to the pump once the plumbing is emptied. Do not reconnect the pump plumbing. Make a note at tank filler as a reminder: "Plumbing is disconnected."

TROUBLESHOOTING Vibration induced by driving can loosen plumbing, strainers and pump hardware. Check for system components that are loose. Also, refer to the chart below for trouble-shooting tips. PUMP WILL NOT START/ BLOWS CIRCUIT Electrical connections, fuse or breaker, main switch, and ground connection. Is the motor hot? Thermal breaker may have triggered; it will reset when cool. Is voltage present at the switch? Bypass pressure sw. Does the pump operate? Charging System for correct voltage (±10%) and good ground. For an open or grounded circuit, or motor; or improperly sized wire. For seized or locked diaphragm assembly (water frozen?). WILL NOT PRIME/SPUTTERS (No discharge/motor runs) Is the strainer clogged with debris? Is there water in the tank, or has air collected in the hot water heater? Is the inlet tubing/plumbing sucking in air at plumbing connections (vacuum leak)? Is inlet/outlet plumbing severely restricted or kinked? Restrictive valves? Proper voltage with the pump operating (±10%). For debris in pump inlet/outlet valves or swollen/dry valves. Pump housing for cracks or loose drive assembly screws. RAPID CYCLING For restrictive plumbing and flow restrictions in faucets/shower heads. Water filter/purifier should be on separate feed line. Shut-off pressure set too low. PUMP WILL NOT SHUT-OFF / RUNS WHEN NOZZLE IS CLOSED Output side (pressure) plumbing for leaks, and inspect for leaky valves or toilet. For air trapped in outlet side (water heater) or pump head. For correct voltage to pump (±10%). For loose drive assembly or pump head screws. Are the valves held open by debris or is the rubber swollen? Pressure switch operation. By-pass set higher than shut-off. NOISY OR ROUGH OPERATION For plumbing which may have vibrated loose. For a restricted inlet (clogged strainer, kinked hose, restrictive valves). SERVICE KITS ITEM 8-11-X07 PART # Is the pump plumbed with rigid pipe causing noise to transmit? Does the mounting surface amplify noise (flexible)? Does it bang like a drum? For mounting feet that are loose or are compressed too tight. For air in the system. Check all fixtures for air and bleed system. The motor with pump head removed. Is noise from motor or pump head? LEAKS FROM PUMP HEAD OR SWITCH For loose screws at switch or pump head. Switch diaphragm ruptured or pinched. For punctured diaphragm if water is present in drive assembly. 8-11-X07 PART # 1 9-800-1 9-800-1 9-800-01 9-800-01 9-800-15 9-800-15 9-71-00-07 9-71-001-17 1,, 9-800-17 9-800-17 Check Valve (not shown) 9-800-0 9-800-0 *With preset switch and by-pass adjustment 1 FILTRATION & PROCESS 55 Harbor Gateway South, Suite 10, Costa Mesa, CA 966, (800) 85-18 www.shurflo.com All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. 911-107 Rev. A 06/1 Pentair, Inc. All Rights Reserved.