Refrigeration Systems and Accessories

Similar documents
AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Energy Use in Refrigeration Systems

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

The Saturation process

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

Use this Construction/HVAC Glossary to answer the questions below.

RSES Technical Institute Training Manual 1 70 hours, 70 NATE CEHs, 7.2 CEUs

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

HEAT PUMPS. Carrier Corporation GT72-01 Cat. No

The Essentials Of Working With R-410A

B. A. T. Basic Appliance Training

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Refrigeration Technology in Building Services Engineering

Refrigeration and Air Conditioning

HVAC/R Refrigerant Cycle Basics

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

6. Within an internal combustion engine, the can-shaped component that moves up and down the cylinder

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Refrigeration Basics from a Brewery Perspective

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

HVAC Service Technicians Training Center

HVAC Fundamentals & Refrigeration Cycle

Chapter-8 Capacity Control of Refrigeration Systems

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Pressure Enthalpy Charts

THERMODYNAMICS PREPARED BY DW & JD

Air-Cooling Evaporators

Evaporative Condenser Engineering Manual

Installation 50% Service 20% Components 20% Applied Knowledge 10%

Technical Development Program

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

: REFRIGERATION & AIR CONDITIONING COURSE CODE : 6023 COURSE CATEGORY : A PERIODS/ WEEK : 6 PERIODS/ SEMESTER : 90 CREDIT : 6 TIME SCHEDULE

Case 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage

Appendix A. Glossary of Common Terms

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

How to Diagnose a TXV Failurek

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Otherwise, you can continue reading the file on the following pages.

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

RTP Technical Bulletin

CONTENTS. Air Conditioning Fundamentals TC S

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Energy Management and Controls

DEFROSTING METHODS Adapted from material originally provided by Kenneth S. Franklin, C.M., Director of Service, Hussmann Corporation

Thermodynamics II Chapter 5 Refrigeration

Technical Bulletin (TB-0037)

Refrigerant Transfer and Compressor Damage

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

HVAC Basics RESIDENTIAL AIR CONDITIONING

National Maritime Center

Refrigeration/Troubleshooting Manual

Superheat charging curves for technicians

R-407A R-448A R-449A

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

THERMOSTATIC EXPANSION VALVES Part 1

USING THE P-T CARD AS A SERVICE TOOL

CTI Sponsored Educational Program

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

APPLICATION & SERVICE GUIDE

HEAT PUMPS. Carrier Corporation GT72-01A Cat. No

Service Step by Step Trouble-Shooting Check-List

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

PREVIEW COPY. Compressors. Table of Contents. Introduction to Compressors...3. Lesson Two Reciprocating Compressors...21

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

UNITED STATES MARINE CORPS ENGINEER EQUIPMENT INSTRUCTION COMPANY MARINE CORPS DETACHMENT 686 MINNESOTA AVE FORT LEONARD WOOD, MISSOURI

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

Refrigeration System with a Capillary Tube and a Thermostat

Fundamentals of Refrigeration Part 2 Refrigeration 1

CO2 TRANSCRITICAL BOOSTER SYSTEMS

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Thermodynamics II Chapter 6 Mixtures & Psychrometry

Adsorption Chillers Energysmart Green Cooling

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

30GN FLOTRONIC II AIR-COOLED CHILLERS

(ME-225) HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

Desiccants & Driers. By Norm Christopherson

Midwest Industrial Initiative Webinar: Industrial Refrigeration

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

30GT FLOTRONIC AIR-COOLED CHILLERS

HVAC (Heating, Ventilating, and Air Conditioning)

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Transcription:

As with the Chapter Review Tests and the Final Exam, the tests your understanding of the materials underlying the learning objectives. After you ve reviewed your answers to the Chapter Review Tests, try your hand at this 50-question to become still more comfortable with taking a multiple-choice test. Remember, topics covered in this exam may likewise be covered in the Final Exam, but the wording of the questions will never be identical.

1. Which is a disadvantage of a packaged indoor unit? a. it typically needs less ductwork b. valuable space that could be leased is not lost c. the potential for excessive noise exists d. it requires a separate coil to cool the building 2. Removing oil and filtering refrigerant for reuse is called: a. recovery. b. recycle. c. reclaim. d. remand. 3. Which is the best description of temperature? a. degree of resistance b. intensity of heat c. measurement of pressure d. level of saturation 4. (Fill in the blank) The type of head pressure control in a condenser that helps prevent drops in head pressure is the type. a. fan cycling b. condenser flooding c. damper control d. All of the above. 5. Which refrigeration system accessory is used to remove moisture, acid, and debris? a. suction accumulator b. filter drier c. receiver d. oil separator 6. Nearly all electronic leak detectors use an element that is sensitive to: a. moisture and density. b. light. c. air movement. d. halogenated gases. 7. All of the following are types of synthetic oil except: a. esters. b. naphthalenes. c. alkylbenzenes. d. glycols.

8. All of the following are used in cooling towers to spread the water for more efficient cooling except: a. fill material. b. distribution pan. c. expansion valve. d. sprays. 9. (Fill in the blank) The one major difference between a low-pressure chiller and a highpressure chiller is the system. a. defrost b. purge c. size of the d. lubrication 10. Which is most likely to cause low to no superheat? a. low charge (too little refrigerant) b. thermostatic expansion valve overfeeding c. moisture in the thermostatic expansion valve d. metering device malfunctioning 11. What does purging do in absorption machines? a. speeds up the system cycle b. removes water from a system c. raises condenser water temperature d. removes noncondensables 12. Which is false concerning azeotropic refrigerants? a. they behave as pure compounds b. they act as one refrigerant in all conditions c. they are subject to fractionation d. they are a blend of multiple components 13. Which condenser contains a number of straight tubes through which the cooling water is circulated while the refrigerant vapor surrounds the tube bundle? a. tube within a tube b. open vertical shell and tube c. shell and coil d. horizontal shell and tube

14. Which is a type of cooling tower fill material design that spreads the water evenly to form thin layers? a. film type b. splash type c. natural-draft type d. mechanical type 15. A defrost cycle is required for a(n): a. through the wall unit. b. air-to-water heat pump. c. split system. d. air-to-air heat pump. 16. With regard to cooling towers, which device is necessary for a closed loop system but not for an open loop system? a. fill material b. distribution pan c. heat exchanger d. condenser 17. (Fill in the blank) Transformers have a(n) rating that should never be exceeded. a. AC/DC b. volt/amp (VA) c. differential d. state inspection 18. (Fill in the blanks) A suction accumulator is used to prevent refrigerant from entering the suction side of the. a. vapor; evaporator b. vapor; compressor c. liquid; evaporator d. liquid; compressor 19. A plate type evaporator is: a. made up of two flat metal pieces seamed together with liquid refrigerant flowing through a tube between the pieces. b. no longer environmentally acceptable. c. essentially a tube coil with exterior aluminum pieces attached to it. d. not much more than a bent tube.

20. Which best describes a liquid bulb charge? a. mostly liquid charge that is different from the refrigerant in the system and remains partially liquid as the refrigerant boils and vaporizes b. mostly liquid charge that is the same as the refrigerant in the system and remains partially liquid as the refrigerant boils and vaporizes c. small amount of liquid refrigerant that is different from the refrigerant in the system and boils to a vapor as the temperature rises d. small amount of liquid refrigerant that is the same as the refrigerant in the system and boils to a vapor as the temperature rises 21. (Fill in the blank) In a split system, the indoor section typically consists of the evaporator, fan(s),, and a connection for the suction and liquid lines. a. a compressor b. a metering device c. a condenser d. water connectors 22. (Fill in the blank) A reciprocating compressor increases the pressure of the refrigerant by the volume of the compression chamber. a. increasing b. lowering c. increasing, then lowering d. lowering, then increasing 23. Which is the best definition of radiation? a. the transferring of heat from a warm substance to a cooler substance without heating the medium b. the transferring of heat from one place to another using a fluid that also heats c. the transferring of heat only within a substance through molecular motion d. the transferring of heat within a substance or from one substance to another in physical contact 24. (Fill in the blank) The fusible plug type of pressure relief device works by responding to. a. high temperature b. high pressure c. low temperature d. low pressure 25. The low-pressure safety cut out stops the refrigeration equipment at a predetermined: a. minimum run time. b. maximum start-up pressure. c. maximum run time. d. minimum operating pressure.

26. Which is the correct order of the three stages a refrigerant goes through while moving through a condenser? a. de-superheating, condensing, subcooling b. condensing, de-superheating, subcooling c. condensing, subcooling, de-superheating d. de-superheating, subcooling, condensing 27. How does a scroll compressor work? a. piston-like motion b. screw-in motion c. back-and-forth motion d. orbiting motion 28. All of the following are advantages of open compressors except: a. compressor does not need to be replaced if the motor fails b. easy to change motors c. easy to change pumping capacity d. does not need a shaft seal 29. Which chiller safety is used to provide relief in the event of over-pressurization? a. flow switch b. high temperature motor winding cut out c. rupture disc d. lock out timer 30. What does a screw chiller use to force the oil from the separator back to the compressor during normal operation? a. oil pump b. suction lines c. gravity d. high-side pressure 31. (Fill in the blank) The differential setting for a control device is defined as the the cut in (enable) and the cut out (disable) points of the control. a. average of b. sum of c. halfway point between d. difference between

32. (Fill in the blank) A change in heat results in a change in temperature but not in the state. a. specific b. external c. sensible d. latent 33. Which is a device that uses the evaporation of water to reject both the sensible and the latent heat absorbed in a refrigeration system? a. compressor b. metering device c. cooling tower d. condenser 34. When a halide leak detector detects a leak, the flame will: a. move back and forth rapidly. b. suddenly become bigger. c. change to a greenish color. d. go out. 35. A thermostatic expansion valve works off all of the following pressures except pressure. a. bulb b. condenser c. evaporator d. superheat spring 36. (Fill in the blank) Before using a(n) leak detector, consult the compressor manufacturer to ensure that the dye will not harm the compressor and thus void any warranty. a. ultraviolet b. ultrasonic c. electronic d. halide 37. What is range of the control? a. the sum of the minimum and the maximum operating points within which the control will function b. the difference between the cut in (enable) and the cut out (disable) points of the control c. the difference between discharge and suction pressures d. the difference between the minimum and the maximum operating points within which the control will function

38. A refrigerant is a fluid that gives up heat by: a. evaporating at a low temperature and pressure. b. condensing at a low temperature and pressure. c. evaporating at a high temperature and pressure. d. condensing at a high temperature and pressure. 39. Which is an advantage of a hermetic compressor? a. is field serviceable b. optimal on systems in excess of 30 tons c. does not require lubrication d. does not need a shaft seal 40. (Fill in the blank) Enthalpy is defined as the total content of a substance. a. chemical b. heat c. cooling effect d. viscous 41. A heat pump cannot operate efficiently once the outside temperature falls below: a. 20 F. b. 32 F. c. 50 F. d. 42 F. 42. Which is most likely to cause low to no subcooling? a. oversized condenser b. thermostatic expansion valve overfeeding c. inefficient compressor d. overcharge (too much refrigerant) 43. Which bulb charge is best described as a mostly liquid charge that is different from the refrigerant in the system and remains partially liquid as the refrigerant boils and vaporizes? a. liquid charge b. cross vapor charge c. cross liquid charge d. vapor charge 44. Which refrigeration system accessory is used to dampen the hot gas pulsations set up by a reciprocating compressor? a. pressure relief device b. muffler c. vibration absorber d. suction accumulator

45. Which is most likely to cause high head pressure? a. low water temperature or ambient air temperature b. inefficient compressor valves c. low load conditions d. overcharge (too much refrigerant) 46. Which is an advantage of a capillary tube metering device? a. pressures equalize between the condenser and evaporator during off cycles b. since sizing is not crucial, generic replacements are viable alternatives c. no moving parts means no throttling down the flow of refrigerant d. overcharging the system will only lead to evaporator flooding 47. An engineer wants to use a thermometer that is based on an absolute scale and that has the broadest range of temperatures between the freezing and boiling points of water. Which temperature scale should he use? a. Fahrenheit b. Rankine c. Celsius d. Kelvin 48. Which is most likely to cause high suction pressure? a. loss of refrigerant b. lack of airflow across the evaporator c. low load conditions d. inefficient compressor 49. Which is false concerning water-cooled chiller condensers? a. they require a cooling tower, water treatment, and regular cleaning of condenser tubes b. they are generally used in larger capacity systems (up to 1,500 tons) as compared to air-cooled condensers c. they are less energy efficient than air-cooled condensers when operating at design conditions d. they are smaller in size compared to air-cooled condensers of similar capacity 50. Where is a receiver located in a refrigeration system? a. after the condenser on the liquid line b. after the evaporator on the liquid line c. next to the metering device d. before the condenser on the vapor line

Answers 1. C 2. B 3. B 4. D 5. B 6. D 7. B 8. C 9. B 10. B 11. D 12. C 13. D 14. A 15. D 16. C 17. B 18. D 19. A 20. B 21. B 22. B 23. A 24. A 25. D 26. A 27. D 28. D 29. C 30. D 31. D 32. C 33. C 34. C 35. B 36. A 37. D 38. D 39. D 40. B 41. B 42. B 43. C 44. B 45. D 46. A 47. B 48. D 49. C 50. A