Refrigeration System with a Capillary Tube and a Thermostat

Similar documents
SXY MAINTENANCE SECTION M-1

HVAC Basics RESIDENTIAL AIR CONDITIONING

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

Air Conditioning Operation and Troubleshooting Matt Dunham

Glass Door Merchandiser. Model RM-49

Glass Door Merchandiser

Refrigeration Training System

Glass Door Merchandiser. Model RM-45-SD

A/C-HEATER SYSTEM - MANUAL

SECTION 9 DOMESTIC APPLIANCES UNIT 47 ROOM AIR CONDITIONERS

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)

Grades Prentice Hall. Fundamentals of HVAC/R HVACR High School ISBN's SE / IG Grades 9-12

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES UNIT OBJECTIVES. After studying this unit, the reader should be able to

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

WineZone Ceiling Mount Ductless Split 15

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Room Air Conditioner Service and Parts Manual

NABTEB Past Questions and Answers - Uploaded online

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Commercial High-Efficiency Condensing Units

CWS AIR-CONDITIONERS

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

MERIT SERIES Up Flow / Horizontal

SERVICE MANUAL FOR MODEL RM-49

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

MODELS B1PA024, 030 AND 036

MERIT Series R-410A - Upflow / Horizontal

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Use this Construction/HVAC Glossary to answer the questions below.

AHG**-0B Series Hydronic Air Handling Units

3400-3A Refrigeration System Demonstrator

MERIT Series R-410A - Upflow / Horizontal

Refrigeration Basics from a Brewery Perspective

38LB/38LF AIR COOLED CONDENSING UNIT

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Refrigeration Systems and Accessories

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

ICEU 36 SPARE PARTS LIST REV. 07/2016

WAEC Sample Questions and Schemes - Uploaded online by AIR-CONDITIONING AND REFRIGERATION

Commercial High-Efficiency Condensing Units

SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

APPLICATION and INSTALLATION

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

Commercial Refrigerator Service Manual

AE October 1965 Reformatted October Hot Gas Bypass Control Systems

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

RSES Technical Institute Training Manual 1 70 hours, 70 NATE CEHs, 7.2 CEUs

TROUBLESHOOTING VANGUARD

Automotive Air Conditioning systems

AFE400 SERVICE PARTS

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

DEFROSTING METHODS Adapted from material originally provided by Kenneth S. Franklin, C.M., Director of Service, Hussmann Corporation

SERVICE MANUAL FOR MODEL RM-10

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

HEAT PUMPS. Carrier Corporation GT72-01 Cat. No

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Double Door Over 70. Service Manual. Models: F NMTZH 821 F T F NMTZH 822 F T

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

GCG-26c. Instruction Manual. G-Series Cooler

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

SERVICE MANUAL FOR MODEL RM-26

Component Replacement Guidelines. For AIRSYS Wall Packaged Units. Models

V Refrigeration Module

Energy Use in Refrigeration Systems

Reach-In Refrigerators and Freezers Service Manual

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

HEATING AND VENTILATION

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

REPLACEMENT PARTS MANUAL

- 1 - Updated on 18 March, 2010

RED DOT UNITS. Heating & Air Conditioning. Parts

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

CME650 SERVICE PARTS

Course Outline. TERM EFFECTIVE: Spring 2018 CURRICULUM APPROVAL DATE: 10/23/2017

Bulletin , March Electric Hot Gas Bypass Valves

Transcription:

Exercise 2-1 Refrigeration System with a Capillary Tube Part A: REFRIGERATION CIRCUIT OBJECTIVE When you have completed this part, a refrigeration circuit using a capillary tube as a metering device will be ready to accept the refrigerant. DISCUSSION Figure 2-2 shows a typical refrigeration system with a capillary tube. In the evaporator, liquid refrigerant absorbs heat from the air passing over the surface of the coil. When heat is absorbed, the liquid changes to a vapor. The heated vapor is drawn into the compressor where it is subjected to an increase in pressure. The temperature of the vapor therefore increases. Figure 2-2. Typical refrigeration system using a capillary tube as a metering device. The compressor is the heart of the refrigeration system. It is a circulating pump, drawing the refrigerant vapor (at low pressure) from the evaporator through a suction-line accumulator and compressing it into the condenser. 2-3

The refrigerant vapor in the condenser is under high pressure and at a high temperature. The vapor passes through the condenser where sensible and latent heat is removed bringing the vapor into a liquid state. The liquid refrigerant is still under high pressure. The liquid then flows through the capillary tube which immediately reduces the pressure. The decrease in pressure lowers the temperature. The cold, low pressure liquid then flows through the evaporator, allowing the refrigerant to boil and vaporize, absorbing heat from the refrigerated space. The cycle then repeats as the heated vapor is drawn to the compressor. ACTIVITY Identify the different components in the refrigeration schematic (Figure 2-2) and position them in such a way that the circuit can be completed. For this purpose, we suggest you to take off the panel and place it flat on your workbench. To help position the different components, use the suggested layout of Figure 2-3. Once the components are positioned assemble the refrigeration circuit by cutting, flaring and bending the different pipes. Once the circuit is assembled, fasten the circuit to the wooden board using the supplied brackets. Tighten all joints and check for leaks. Charge the system. Part B: WIRING THE TRAINER OBJECTIVE When you have completed this part you will be able to explain the electrical circuits associated with the trainer set up using a capillary tube as a metering device. DISCUSSION The power is fed to the circuit through the line cord and the protective breaker assembly. 2-4

Figure 2-3. Suggested layout. The switch S1 shown in Figure 2-4, is used as the main switch. When turned on, it will energize all the other components through their appropriate circuits. The switch S2 will energize the thermostat circuit and the built in indicator light will turn on. When the temperature increases above the set point of the thermostat, it will close its contacts energizing the compressor motor through its current relay CR and its thermal protection OL. The indicator lamp P2 will turn on. The current relay and thermal protection relay are built into the compressor. 2-5

Figure 2-4. Electrical schematic diagram of a capillary tube system. On starting, the compressor will draw a high current (approximately 4-5 times the running current). This high current inrush will actuate the armature of the current relay, will close its contacts, and allow the capacitor and the start winding of the compressor to be energized. Once the compressor motor is running, the current will drop to the nominal value and the current relay will open its contacts, de-energizing the starting winding. The compressor will run until the thermostat opens its contacts, calling for an automatic stop, or until the switch S2 is opened manually. Note that the overload relay could also stop the compressor should it be in an overload or an overheated condition. The switch S3, when closed manually, will energize the condenser fan and will turn on the indicator lamp P3. The switch S4, when closed manually, will energize the evaporator fan and will turn on the indicator lamp P4. The switch S5, when closed manually, will energize the heat load into the refrigerated chamber simulating the presence of a warm object to be cooled. It will also turn on the indicator lamp P5. 2-6

ACTIVITY Identify the different electrical components in the schematic of Figure 2-4, and locate them in the boxes already mounted. A suggested layout for the switches is shown in Figure 2-5. The heat load and evaporator wiring is shown in Figure 1-7 Figure 2-5. Suggested layout for switches. 2-7

Refer to Figure 2-6 for the location of the indicator lamps. They were wired at the factory to simplify the final wiring. Figure 2-6. Control panel face plate showing the compressor switch and the indicator lamps. Determine the minimum number of wires that are necessary to connect each component using a minimum of conductors into each cable joining the different components and the control panel. The connections between the different wires into the control panel can be secured using connectors and can be done through the terminal board of the indicator panel shown in Figure 2-7. Figure 2-7. Control panel terminal block wiring diagram. 2-8