Chapter 1 Preface & General

Similar documents
Copy Right By: Thomas T.S. Wan

Partial Load Performance Of Refrigeration System

Chapter 4 Compressors Overview & System Annual Power Consumption

Cascade Refrigeration System for LPG Subcooling. Related Technical Data and Information for the Case:

2. CURRICULUM. Sl. No.

Midwest Industrial Initiative Webinar: Industrial Refrigeration

Page 1 of Relevant Provincial Jurisdictional legislation.

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Case 13 Food Storage & Processing Center

Air-Cooling Evaporators

Intermediate Refrigeration Systems for Operators

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

REFRIGERATION AND AIR CONDITIONING

: REFRIGERATION & AIR CONDITIONING COURSE CODE : 6023 COURSE CATEGORY : A PERIODS/ WEEK : 6 PERIODS/ SEMESTER : 90 CREDIT : 6 TIME SCHEDULE

Transcritical CO2 Bottle Cooler Development

REFRIGERATION AND AIR CONDITIONING

Copy Right By: Thomas T.S. Wan

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

HVAC Service Technicians Training Center

Brazed Plate Heat Exchanger for CO Applications

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

Case 6 Impact of Fouling Factor and Special Material for Heat Exchanger

Chapter 11 REFRIGERATION CYCLES

Fundamentals of Refrigeration p. 25 History and Fundamentals of Refrigeration Module p. 25 Development of Refrigeration p. 25 How a Mechanical

Thermodynamics II Chapter 5 Refrigeration

Refrigeration Systems

Thermodynamics I. Refrigeration and Heat Pump Cycles

RSES Technical Institute Training Manual 1 70 hours, 70 NATE CEHs, 7.2 CEUs

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

Refrigerator and Heat Pump Objectives

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

Refrigeration Technology in Building Services Engineering

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

PREVIEW COPY. Compressors. Table of Contents. Introduction to Compressors...3. Lesson Two Reciprocating Compressors...21

Appendix 13. Categories of Cooling and Heating systems

Pack Calculation Pro. Users guide. Version Morten Juel Skovrup

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Ammonia Refrigeration & Scenario in Industrial Refrigeration. By Ramesh Paranjpey ASHRAE Fellow Life member

Refrigeration Systems and Accessories

Short Questions with Answers APPLIED THERMODYNAMICS(5 TH MECHANICAL) Chapter No-1

STAR YOUR OWN COLD STORAGE UNIT

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

CASE STUDY AIR-CONDITIONERS

REDUCING AMMONIA REFRIGERANT CHARGE IN SKATING RINK REFRIGERATION SYSTEMS

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

HVAC Water chiller selection and optimisation of operation

R07. Answer any FIVE Questions All Questions carry equal marks *****

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Chapter 11 REFRIGERATION CYCLES

Case 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

HEAT PUMPS. Carrier Corporation GT72-01 Cat. No

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

4.1 Refrigeration process comparison

Industrial Refrigeration. Allbest Creative Development Ltd. (ALLBEST)

Chapter-8 Capacity Control of Refrigeration Systems

The cold chain in the fishery sector. Refrigeration Technology Review

Air Conditioning Inspections for Buildings Condensers

SECTION 9 DOMESTIC APPLIANCES UNIT 47 ROOM AIR CONDITIONERS

MU053: CHILLERS: Operation & Maintenance of Chilled Water Systems

HEAT EXCHANGERS Maximize Thermal Efficiency with LaZerWeld Plate Heat Exchangers. For Industrial Refrigeration

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

INSTANT CHILLER. Chester-Jensen Co., Inc. Unit Construction and Short Gas Flow

TWO- AND THREE-STAGE CASCADE REFRIGERATION SYSTEM By: Paul B. Reed

Chilled Water system

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

Energy Efficiency Considerations in Refrigeration Systems

Chapter 9. Refrigeration and Liquefaction

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

Teaching and Examination Scheme PAPER HRS TH PR OR TW TOTAL TH TU PR

PIPING SYSTEM EQUIPMENTS

CO2 TRANSCRITICAL BOOSTER SYSTEMS

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Use of transcritical CO 2 in industrial applications

YOUR BASIC REFRIGERAION SYSTEM SVASD MAY 26, 2011

energydesignresources

2013 Guideline for Specifying the Thermal Performance of Cool Storage Equipment. AHRI Guideline T (I-P)

Improving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions.

Evaporators. Direct Expansion Flooded Recirculated Over Feed

Goedhart air coolers. Goedhart Blast freezers (LLK.p) JUST IN TIME!!

EN aquatech.piovan.com

JEFFERSON COLLEGE COURSE SYLLABUS HRA 249 COMMERCIAL REFRIGERATION SYSTEMS. 5 Credit Hours. Prepared by: William Kaune November 30, 2010

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

PACKAGED REFRIGERATION EQUIPMENT

HVA 220 COMMERCIAL AND DOMESTIC REFRIGERATION

GLIDER_. air cooled liquid chilled chillers / heat pumps

Presentation on HVAC: Heating Ventilation Air Conditioning

Transcription:

Chapter 1 Preface & General Copy Right By: Thomas T. S. Wan 温到祥著 Sept. 3, 2008 All rights reserved Preface: This manual is intended for someone who has the prior basic education of refrigeration and has the basic knowledge of mechanical engineering such as thermodynamics, heat transfer and etc. This manual is mostly dealing with application practices for industrial refrigeration application which is for industrial production and hydrocarbon processing. What is Engineered Refrigeration System? Engineered Refrigeration System means to design a refrigeration system to meet the requirements of a process or for the need of the production for a specific application with a specific design operation. It is absolutely not accommodating the process to suit any fixed designed of standard or packaged refrigeration product. Engineered system is to compose, to design, to structure, to build and to install the refrigeration system precisely to fulfill the refrigeration need of the process or for the production. System Concept and System Approach: It is the objective of this manual to emphasize the meaning of System concept and System approach. Each of the components in the refrigeration system has its assigned duty under the design operating conditions. The system operating conditions and the system capacity will change if any one of the components which makes up the refrigeration system is changed. Also, it is important that every step taken and the concept used for the refrigeration system design should be explainable by the related applicable theory. Always check with P-H Diagram and the associated engineering formula to see if the flow and thermodynamic properties are fundamentally correct. These rules are applicable to both primary refrigerant circuit and the secondary refrigerant circuit if brine is used for the system. Try to exam the function and the character of each component including each device and valve to see how it is fitted into the structure of the system. - 7 -

Refrigeration Industries and Product Segment Classification: Various industries and customer users require different types of refrigeration technique, equipment, application and system for its process need and for the making of their product. Therefore, base on the user groups, the refrigeration business can be classified into several major segments as the following: Industrial Refrigeration This is an engineered system either field erected or factory specially designed and assembled systems for the industries such as Chemical, Hydrocarbon Processing, Oil, Petrochemical, Natural Gas Processing and other industries that might require industrial grade refrigeration system. Central Systems for Food and Beverage This might be a field erected system or factory engineered unit. This application is mainly provided for the installations of cold storage, food processing and freezing. Walk-in Cold Storage and Freezers This sector of refrigeration application is for smaller scale of food storage. The refrigeration equipment use for this application is mostly factory packaged. Transportation Refrigeration Packaged product, mainly use for food distribution and transportation. This includes container refrigeration. Display Casings Packaged refrigeration equipment use for supermarkets. Packaged Refrigerator and Freezer Units for home, commercial and restaurant users. The application for other industrial users such as Pharmaceutical, Environmental Simulation, Electronics and etc. are usually covered by the refrigeration equipment and system suppliers of Industrial Refrigeration and/or Food and Beverage. This manual is mainly to be used for the applications for Industrial Refrigeration and for large central commercial refrigeration. Basic Refrigeration System Review: A refrigeration system, no matter simple or complex, it is a combination of four principal components, the Compressor, Condenser, Refrigerant Metering Device and the Evaporator as shown in Fig. 1-1. In a central refrigeration system, for various application requirements, each component might have different design as the following: - 8 -

- 9 -

Compressor can be either Reciprocating or Centrifugal or Screw. Condenser can be either water cooled shell-and-tube design or air cooled finnedcoil or evaporative wetted pipe or finned-coil. Flow Metering Device can be either Expansion Valve or High Pressure Float Valve or Low Pressure Float Valve. Evaporator can be either air finned-coil such as Unit Cooler, Product Cooler or horizontal shell-and-tube heat exchanger or vertical special column. For some system, it requires other components such as Economizer, Intercooler, Suction Trap, High Pressure Receiver, Low Pressure Receiver, Oil Receiver or Pump Recirculation Receiver. Besides of the components, refrigerant piping, oil system, control system and power system are required for a central system. Defrosting system and other things might also be considered for some application. Various Refrigeration Systems Description: Single Stage Refrigeration System: Reciprocating Compressor. Screw Compressor. Single Stage Centrifugal Compressor. Compound Refrigeration System: Internally Compound Compressor. Reciprocating to Reciprocating Compressor. Rotary to Reciprocating Compressor. Screw to Reciprocating Compressor. Single Stage Centrifugal to Reciprocating Compressor. Screw to Screw Compressor. Single Stage Centrifugal to Screw Compressor. Single Stage to Multistage Centrifugal Compressor. Screw to Multistage Compressor. Multistage Centrifugal to Multistage Centrifugal Compressor. Cascade Refrigeration System: Reciprocating to Reciprocating Compressor. Screw to Reciprocating Compressor. Screw to Screw Compressor. Multistage Centrifugal to Screw Compressor. Multistage Centrifugal to Multistage Centrifugal Compressor. - 10 -

System description also defines refrigerant feed and the type of Evaporator and the arrangement as the following: Open System Refrigerant flow is never returned back to the system. Closed System Refrigerant flow is continuously recirculated, Direct Expansion System. Flooded System. Liquid Recirculation System. Brine or Water Chilling System. Thermosyphone Evaporator System. System description is also can be identified by the method of heat rejection: Air Cooled System. Water Cooled System. Evaporative Condensing System. A refrigeration system can easily be described by high lighting the type of system, type of evaporator, refrigerant feed and method of heat rejection. For example: the system is screw to screw compound brine chilling system with water cooled condenser. - 11 -