MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Similar documents
DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

14 AC x

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

2 shp 13 lc 1 36 t - 1 a

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

T S A 048 S 4 N 4 1 T

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

T P A 120 S 4 S N 1 Y

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

T P A 048 S 4 N 4 1 T

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

Visit us at For the latest technical information,

ELITE Series R-410A - Two-Stage Compressor

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

ELITE Series Variable Capacity

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

ELITE Series Variable Capacity

13 GEP A L P - 1 A

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes August 2008

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

C22FC Bulletin # October 1993 Supersedes May 1993

RGE 13 A T - 1 A

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

Commercial High-Efficiency Condensing Units

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Commercial High-Efficiency Condensing Units

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Ruud Achiever Series Air Conditioners

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

XC21. DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL SPECIFICATIONS

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

TECHNICAL SPECIFICATIONS

PRODUCT SPECIFICATIONS

PACKAGE AIR CONDITIONER

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

PAJ3. Product Specifications

16 SEER TWO-STAGE AIR CONDITIONERS

C22 Bulletin # October 1993 Supersedes May 1993

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

Lennox 8 Series Single Zone - R-410A

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

CB X 32 mv

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

R4H4. Product Specifications

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

TECHNICAL SPECIFICATIONS

Product Data. Split System Heat Pump D-EN. February 2016

INSTALLATION INSTRUCTIONS

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

WCH5**4. Product Specifications

DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

R4H4. Product Specifications

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

MAC N-407 Air-Cooled Chiller

RSG16**S1M. Split System Air Conditioner 16 SEER

TECHNICAL SPECIFICATIONS

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Corp L2 Revised

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Condensing Units & Air Handlers

Transcription:

PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh MODEL NUMBER IDENTIFICATION 13 AC x n 024-230 - 17 Nominal SEER Minor Revision Number Unit Type AC = Air Conditioner Voltage 230 = 208/230V-1phase-60hz Refrigerant X = R-410A Regional Standards N = North Region Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 042 = 3.5 tons 048 = 4 tons 060 = 5 tons

FEATURES CONTENTS Dimensions... 7 Electrical Data... 6 Features... 2 Field Wiring... 8 Installation Clearances... 8 Model Number Identification... 1 Optional Accessories... 6 RFC Orifice Usage... 10 Sound Data... 8 Specifications... 6 TXV Usage... 9 E C D B NOTE! For the latest AHRI System Matches please see the Residential Matchup Tool at www.lennoxpros. com or see the separate document AHRI Air Conditioner Matches that contains all outdoor unit matches. F WARRANTY Compressor - limited warranty for five years in residential installations and five years in non-residential installations. All other covered components - five years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS AHRI Certified to AHRI Standard 210/240-2008. Sound rated in Lennox reverberant sound test room in Accordance with test conditions included in AHRI Standard 270-2008. Tested in the Lennox Research Laboratory environmental test room. Rated according to U.S. Department of Energy (DOE) test procedures. Region specific models meet the minimum efficiency requirements for U.S DOE Federal Regional Standards in that area. Units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC. Units are ETL certified for the U.S. and Canada. ISO 9001 Registered Manufacturing Quality System. For expanded ratings, see www.lennoxpros.com. APPLICATIONS 1.5 through 5 ton. Sound levels as low as 76 db. Single-phase power supply. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI System Matches. See Indoor Coils and Air Handlers sections for data. Units shipped completely factory assembled, piped and wired. Each unit test operated at the factory ensuring proper operation. Installer must set air conditioner, connect refrigerant lines and make electrical connections to complete job. 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 2

B C FEATURES REFRIGERATION SYSTEM R-410A Refrigerant Non-chlorine, ozone friendly, R-410A. Unit pre-charged with refrigerant. See Specification table. Condenser Fan Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has sleeve bearings and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion. Rain shield on motor provides additional protection from moisture. Louvered steel top fan guard furnished as standard. Fan service access accomplished by removal of top panel. Copper Tube/Enhanced Fin Coil Lennox designed and fabricated coil. Ripple-edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to ensure leakproof construction. Steel louvered panels provide complete coil protection. Panels can be completely removed for servicing. High Capacity Liquid Line Drier Furnished with unit for field installation. Approved for use with R-410A systems. Traps any moisture or dirt that could contaminate the refrigerant system. High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Automatic reset. Refrigerant Flow Control Units applicable to expansion valve systems or RFC systems when matched with specific indoor coils. RFCIV: Accurately meters refrigerant in system. Refrigerant control is accomplished by exact sizing of refrigerant metering orifice. The principle involves matching indoor coil with proper bore size of orifice in metering device. Equalizes pressure shortly after compressor stops, unit starts unloaded, eliminating need for additional controls. See RFC Orifice Usage Table on Page 10 for correct matches. Optional Accessories Expansion Valve Kits Must be ordered extra and field installed on certain indoor units. See TXV Usage Table on Page 9. Chatleff-style fittings. O RING Freezestat Installs on or near the vapor line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint. Opens at 29 F and closes at 58 F. Loss of Charge Switch Kit Helps protect the compressor from damage due low refrigerant charge conditions. SPST, normally-closed switch, automatic reset switch mounted on liquid line. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory. Suction line fully insulated. Lines are stubbed at both ends. RFCIV METERING SYSTEM ORIFICE BODY RFCIV (On Coil) ORIFICE LIQUID LINE SCREEN SEAL NUT LIQUID LINE SWEAT CONNECTION 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 3

D FEATURES COMPRESSOR Scroll Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Optional Accessories Compressor Crankcase Heater Protects against refrigerant migration that can occur during low ambient operation. Compressor Sound Cover A reinforced vinyl compressor cover containing a 1-1/2 inch thick batt of fiberglass insulation. All open edges are sealed with a one-inch wide hook and loop fastening tape. CONTROLS Optional Accessories Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally doesn t need a potential relay and start capacitor. In conditions such as low voltage, this kit may be required to increase the compressor starting torque. Compressor Low Ambient Cut-Off Switch Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35 F. Compressor Time-Off Control Kit prevents compressor short-cycling and allows time for suction and discharge pressure to equalize. Permits compressor start-up in an unloaded condition. Automatic reset with 5 minute delay between compressor shut-off and start-up. Indoor Blower Off Delay Relay Delays the indoor blower-off time during the cooling cycle. See AHRI System Matches for usage. Low Ambient Kit Air conditioners operate satisfactorily in the cooling mode down to 45 F outdoor air temperature without any additional controls. Kit can be added in the field enabling unit to operate properly down to 30 F in the cooling mode. Crankcase heater and freezestat should be installed on compressors equipped with a Low Ambient Kit. A compressor lock-out thermostat should be added to terminate compressor operation below recommended operation conditions. Thermostat Thermostat not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book. Timed-Off Control Kit prevents compressor short-cycling and allows time for suction and discharge pressure to equalize. Permits compressor start-up in an unloaded condition. Automatic reset with 5 minute delay between compressor shut-off and start-up. 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 4

E FEATURES CABINET Heavy gauge steel cabinet with five station metal wash process. Louvered heavy gauge steel panels surround unit on all four sides to prevent damage to the coil. Powder paint finish provides superior rust and corrosion protection. Control box is conveniently located with all controls factory wired. Corner patch plate allows access to compressor components. Drainage holes are provided in base section for moisture removal. Optional Accessories Unit Stand-Off Kit Black high density polyethylene feet are available to raise unit off of mounting surface away from damaging moisture. Four feet are furnished per order number. F PermaGuard Unit Base Durable zinc-coated base section resists rust and corrosion. Refrigerant Line Connections, Electrical Inlets, Service Valves Sweat connection suction and liquid lines are located on corner of unit cabinet. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and field wiring inlets are located in one central area of cabinet for easy access. See dimension drawing. 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 5

SPECIFICATIONS General Data Connections (sweat) Northern Region 13ACXN018 13ACXN024 13ACXN030 13ACXN036 13ACXN042 13ACXN048 13ACXN060 Nominal Tonnage 1.5 2 2.5 3 3.5 4 5 Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction line o.d. - in. 5/8 5/8 3/4 3/4 3/4 7/8 7/8 1 Refrigerant (R-410A) furnished 4 lbs. 1 oz. 3 lbs. 14 oz. 5 lbs. 2 oz. 5 lbs. 4 oz. 6 lbs. 8 oz. 7 lbs. 12 oz. 9 lbs. 0 oz. RFCIV Metering Orifice Size Furnished 0.051 0.057 0.065 0.072 0.076 0.082 0.090 Outdoor Coil Outdoor Fan Net face area Outer coil 11.33 11.33 13.22 13.22 16.33 18.67 16.33 sq. ft. Inner coil - - - - - - - - - - - - - - - - - - 15.71 Tube diameter - in. 5/16 5/16 5/16 5/16 5/16 5/16 5/16 Number of rows 1 1 1 1 1 1 2 Fins per inch 26 26 26 26 26 26 22 Diameter - in. 18 18 18 18 22 22 22 Number of blades 3 3 4 4 4 4 4 Motor hp 1/10 1/10 1/5 1/5 1/4 1/4 1/4 Cfm 2350 2350 2400 2400 3500 3670 3600 Rpm 1010 1010 1090 1090 825 835 830 Watts 165 165 185 185 300 295 285 Shipping Data - lbs. 1 package 138 138 144 151 188 195 218 ELECTRICAL DATA Line voltage data - 60 hz - 1ph 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 2 Maximum overcurrent protection (amps) 20 25 25 35 45 50 60 3 Minimum circuit ampacity 12.4 14.7 17.1 22.0 28.1 31.9 34.6 Compressor Rated load amps 9.4 11.2 12.8 16.7 21.2 24.2 26.3 Locked rotor amps 56.6 60.8 64 70 90 100 125 Power factor 0.98 0.98 0.98 0.99 0.99 0.99 0.99 Condenser Full load amps 0.7 0.7 1.1 1.1 1.7 1.7 1.7 Fan Motor Locked rotor amps 1.3 1.3 2.0 2.0 3.2 3.2 3.2 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 93M05 Compressor Hard Start Kit Copeland 10J42 LG 88M91 Compressor Low Ambient 45F08 Cut-Off Switch Compressor Sound Cover 27W55 27W56 Compressor Time-Off Control 47J27 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 4 Low Ambient Kit (Fan Cycling) 34M72 Refrigerant Line Sets L15-26-20, L15-26-25, L15-26-35, L15-26-50 L15-41-20, L15-41-30, L15-41-40, L15-41-50 L15-65-30, L15-65-40, L15-65-50 Unit Stand-Off Kit 94J45 NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 6

DIMENSIONS - INCHES (MM) INLET AIR 4-3/8 4-3/8 (111) (111) 4-3/8 4-3/8 (111) (111) INLET INLET OPTIONAL UNIT STAND-OFF KIT (4) (Field Installed) COMPRESSOR AIR AIR COIL DRAIN OUTLETS (Around perimeter of base) SUCTION LINE CONNECTION 6-3/8 (162) 4-3/8 (111) INLET AIR TOP VIEW LIQUID LINE CONNECTION 6-3/8 (162) 4-3/8 (111) TOP VIEW BASE SECTION A OUTDOOR COIL FAN A DISCHARGE AIR COMPRESSOR C B ELECTRICAL INLETS SUCTION AND LIQUID LINE CONNECTION 2-3/4 (70) 2 (51) SIDE VIEW 3/4 (19) OPTIONAL UNIT STANDOFF KIT (4) (FIELD INSTALLED) SIDE VIEW Model A B C inches mm inches mm inches mm 018 24-1/4 616 25-1/4 641 24-1/4 616 024 24-1/4 616 25-1/4 641 24-1/4 616 030 24-1/4 616 29-1/4 743 28-1/2 724 036 24-1/4 616 29-1/4 743 28-1/2 724 042 28-1/4 718 29-1/4 743 28-1/2 724 048 28-1/4 718 33-1/4 845 32-1/2 826 060 28-1/4 718 29-1/4 743 28-1/2 724 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 7

SOUND DATA 1 Unit Model Octave Band Linear Sound Power Levels db, re 10-12 Watts Center Frequency - HZ 125 250 500 1000 2000 4000 8000 1 Sound Rating Number (db) 018 53 60 64.5 68.5 67 61.5 54.5 76 024 51.5 62 64.5 68.5 67 60.5 53.5 76 030 52.5 62 67.5 69 67 61.5 54.5 76 036 52.5 61 67 69 67 61.5 52.5 76 042 58 68 73.5 75.5 74 69.5 62.5 79 048 57.5 67 73 74.5 71 64 58.5 79 060 57 63 69.5 71.5 71 65.5 60.5 79 NOTE - the octave sound power data does not include tonal correction. 1 Tested according to AHRI Standard 270-2008 test conditions. FIELD WIRING INSTALLATION CLEARANCES - IN. (MM) DISCONNECT SWITCH (By Others) THERMOSTAT (Optional) DISCONNECT SWITCH (By Others) See NOTES B D A LENNOX AIR CONDITIONER C LENNOX HEATING UNIT OR AIR HANDLER UNIT See NOTES See NOTES See NOTES CONTROL BOX A - Two Wire Power B - Two Wire Power (See Electrical Data) C - Two Wire Low Voltage (18 ga. minimum) D - Four Wire Low Voltage (Electro-Mechanical) 18 ga. minimum. Five Wire Low Voltage (Electronic) 18 ga. minimum NOTE - Field Wiring Not Furnished All wiring must conform to NEC or CEC and local electrical codes. NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) Clearance to one of the remaining two sides may be 12 in. (305 mm) and the final side may be 6 in. (152 mm). A clearance of 24 in. must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit. 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 8

TXV USAGE Use this table for C35, CH23, CH33, CH35, CR23 and CR33 Field Installed TXV Match-Ups. Outdoor Unit 13ACXN018 13ACXN024 13ACXN030 13ACXN036 13ACXN042 13ACXN048 13ACXN060 Thermal Expansion Valve (TXV) 12J18 12J18 12J18 12J19 12J20 12J20 12J20 CX35 and CX38 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. If a change out is required it will be listed in the TXV SUBSTITUTIONS table. The correct TXV must be ordered separately and field installed. C35 and CH33/CH35 coils - Replace the factory installed orifice with the expansion valve listed. CR33 and CH23 coils - Use the expansion valve listed. *TXV SUBSTITUTIONS Use this table to determine if the factory installed TXV in the indoor unit needs to be replaced. Outdoor Unit Indoor Coil Factory TXV Replacement TXV 13ACXN030 CX35-48 12J20 12J18 * CX35 coils - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed TXV is used. MOST POPULAR MATCHES Outdoor Unit 13ACXN018 13ACXN024 13ACXN030 13ACXN036 13ACXN042 13ACXN048 13ACXN060 Indoor Unit Model No CX38-30B CX38-30B CX38-30B CX38-38B CX38-43B CX38-49C CX34-49 AHRI STANDARD 210/240 Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated. NOTE! For the latest AHRI System Matches please see the Residential Matchup Tool at www.lennoxpros. com or see the separate document AHRI Air Conditioner Matches that contains all outdoor unit matches. 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 9

RFC ORIFICE USAGE LEGEND: Green = Matches Orifice Furnished With Indoor Coil (no replacement necessary) Yellow = Matches Orifice Furnished With Outdoor Unit (orifice must be field replaced) Blue = Field Provided (must be ordered extra for field replacement) C33 COILS Indoor Coil Factory Orifice Furnished in Coil Outdoor Unit - Orifice Furnished With Outdoor Unit 13ACXN018 13ACXN024 13ACXN030 13ACXN036 13ACXN042 13ACXN048 13ACXN060 0.051 0.057 0.065 0.072 0.076 0.082 0.090 C33-19A-2 0.051 0.065 C33-25A-2 0.057 0.051 0.065 C33-25B-2 0.057 0.051 0.065 C33-30A-2 0.065 0.065 C33-30B-2 0.065 0.057 0.065 C33-30C-2 0.065 0.065 C33-31A-2 0.065 0.065 C33-31B-2 0.065 0.065 C33-36A-2 0.073 0.065 C33-36B-2 0.073 0.065 C33-36C-2 0.073 0.065 C33-38A-2 0.073 0.065 0.072 0.076 C33-38B-2 0.073 0.065 0.072 0.076 C33-42B-2 0.076 0.065 C33-43B-2 0.076 0.065 0.072 0.076 0.082 C33-43C-2 0.076 0.065 0.076 C33-49C-2 0.082 0.076 0.082 0.090 C33-50/60C-2 0.082 0.072 0.076 C33-60D-2 0.093 0.090 C33-62C-2 0.093 0.076 0.082 0.090 C33-62D 0.093 0.082 0.090 C35 COILS Indoor Coil Factory Orifice Furnished in Coil C35-24A-2F 0.057 0.051 0.057 Outdoor Unit - Orifice Furnished With Outdoor Unit 13ACXN018 13ACXN024 13ACXN030 13ACXN036 13ACXN042 13ACXN048 13ACXN060 0.051 0.057 0.065 0.072 0.076 0.082 0.090 C35-24B-2F 0.057 0.065 C35-30A-2F 0.067 0.051 0.057 0.063 C35-30/36A-2F 0.057 0.057 C35-30/36B-2F 0,057 0.065 C35-36A-2F 0.070 0.060 0.063 C35-36B-2F 0.070 0.063 0.072 C35-48B-2F 0.071 0.070 C35-48C-2F 0.071 0.063 C35-49C-2F 0.076 0.076 0.082 0.090 C35-50/60C-2F 0.070 0.070 C35-60C-2F 0.077 0.076 0.082 0.090 C35-60D-2F 0.077 0.082 0.090 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 10

RFC ORIFICE USAGE LEGEND: Yellow = Matches Orifice Furnished With Outdoor Unit (orifice must be field replaced) CH23, CH33, CR33 COILS Indoor Coil Factory Orifice Furnished in Coil Outdoor Unit - Orifice Furnished With Outdoor Unit 13ACXN018 13ACXN024 13ACXN030 13ACXN036 13ACXN042 13ACXN048 13ACXN060 0.051 0.057 0.065 0.072 0.076 0.082 0.090 CH23-41-2 N/A 0.065 CH23-68-2 N/A 0.082 CH33-19 0.065 CH33-25 0.062 0.065 CH33-31 0.071 0.065 CH33-36 0.076 0.065 CH33-42B 0.082 0.065 CH33-43 0.082 0.065 0.072 0.076 0.082 CH33-44/48B 0.082 0.072 CH33-48 0.091 0.065 0.076 CH33-49 0.091 0.076 0.082 CH33-50/60C 0.091 0.076 0.082 CH33-60D 0.099 0.082 CH33-62D 0.099 0.082 CR33-30/36 N/A 0.065 CR33-50/60 N/A 0.072 RFC ORIFICE ORDERING Orifice Size Order No. 0.051 70W93 0.057 97M75 0.060 10W97 0.063 97M76 0.065 10W99 0.072 10W85 0.076 97M78 0.082 97M79 0.090 10W89 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 11

REVISIONS Sections Description of Change Document Moved all AHRI Matches to a separate document. Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2018 Lennox Industries, Inc.