Refrigeration Supplies

Similar documents
Residential Piping and Long Line Guideline

Harold Ag & Mobile Products

REFRIGERATION PRODUCTS

Accumulators - Suction Line

The complete approach to the care and management of A/C & refrigeration systems

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

The natural solution for domestic refrigeration

R E D I C O N T R O L S

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant changeover guidelines

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Sealed Type Liquid Line and Suction Line Specifications

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit

Installation Instructions

Air Conditioning Operation and Troubleshooting Matt Dunham

Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

REFRIGERANT CHANGEOVER

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

OPERATING INSTRUCTIONS

Precise Temperature Control; Compact Footprint

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

Filter Driers with Replaceable Core

4/19/2013. The Changing State of Refrigerants

LEADERS IN LIQUID SCIENCE.

OPERATING INSTRUCTIONS

Refrigerant Recovery Unit, Model RRU134

Installation Instructions

OPERATING INSTRUCTIONS

OWNER S MANUAL (English)

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

RED DOT UNITS. Heating & Air Conditioning. Parts

Copeland Scroll Condensing Units for the Food Service Market

SOLUTIONS TO KEEP IT COOL

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

HVACR Refrigeration

AUTOMOTIVE SPECIALIZATION (Air Conditioning and Heating) STUDENT GRADE RECORD Career & Technical Education

TRS21 IGNITION PROOF SERIES

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Auto Service Test Review. For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

REFRIGERANT RECOVERY SYSTEMS

Air Conditioners (Outdoor)

AUTOMOTIVE HEATING AND

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Cooling System Equipment

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Air Conditioning & Duracool Emery Stora

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

TRS21 IGNITION PROOF SERIES

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

The Essentials Of Working With R-410A

Devair and Miscellaneous Table of Contents

Refrigerant Recovery/Recharging Series

REFRIGERANT REFERENCE GUIDE

PULSE WIDTH MODULATING VALVES

208 For more information visit our website at

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

DESIGN STANDARDS SECTION 15600

INSTALLATION INSTRUCTIONS

2002 Dodge Caravan SE

1. Can SUPER SEAL ACR, SUPER SEAL HVACR & SUPER SEAL COMMERCIAL be used interchangeably? No, use as per application guidelines below:

OWNER S MANUAL (English)

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Application Guide. Retrofit Guidelines

INSTALLATION INSTRUCTIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

A/C SYSTEM GENERAL SERVICING

Gary Parker Refrigerants Product Manager

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

Gary Parker Refrigerants Product Manager

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

Research Design Quality Value Service Experience

SpeedClean. Work Smarter NEW! Innovative cleaning products for maximum HVAC system efficiency. Innovative Maintenance Tools.

OPERATION & MAINTENANCE MANUAL AC860

HVAC Service Technicians Training Center

INSTALLATION INSTRUCTIONS

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Aspects of the. Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement.

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

DEHYDRATORS AND FILTERS

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

OPER LV Wheeler Way

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Transcription:

Section 11 Refrigeration Supplies INDEX Refrigerant.. 11-2 R-410A. 11-2 HOT-SHOT by ICOR.. 11-2 NU-22b by ICOR. 11-2 Recovery Service 11-2 Recovery Tanks. 11-2 608 Certification. 11-2 Supplies Filter Driers. 11-3 Acid Test Kits 11-3 Valve Cores. 11-3 Saddle Tap Valves. 11-3 Controls Fan Cycle Switches.. 11-4 Low Pressure Switches 11-4 Thermal Expansion Valves.. 11-4 Compressors Replacement Compressors Service Ready Parts 11-4 11-1

Refrigeration Supplies REFRIGERANT R22 or HCFC-22 is a single component HCFC refrigerant. Used in a wide variety of residential and commercial applications. R-410A: A blend of R-32 and R-125. This blend has about 60% higher pressure than in air conditioning applications, and therefore should be used only in new equipment specifically designed to handle the pressure. R-410A will require POE lubricants. Retrofitting equipment with R410A is not recommended under any circumstances. REFRIGERANT - REPLACEMENT Direct Replacement For:, R-407C, and R-417A. NU-22B closely mimics the operating characteristics of, making it the high-performance choice for both OEM and service replacement uses. No complications, no expensive retrofits. You won t need any product-specific tools or supplies to use NU-22B. It s compatible with all standard oils and all standard equipment components and materials used in systems. CSI # Description Size Price MUST PRESENT EPA CARD TO PURCHASE 901-NU-22B NU-22B (R22 DROP IN) - 25# CYLINDER 463.89 CSI # Type Size Price REFRIGERANT RECOVERY 901-R22 30 # Cylinder 722.22 901-R410A R-410 25 # Cylinder 163.89 R22 Phase out schedule: January 1st, 2010 No new R22 can be manufactured for new HVAC equipment (i.e. Air Conditioners or Heat Pumps.) January 1st, 2020 No gas can be manufactured or imported into the United States. Direct Replacement For: R-12, R-500, R-134a Simple and easy to use refrigerant recovery service. Simply bring in your full generic recovery cylinders and swap them with an empty one. One simple and easy ID tag to fill out on your return cylinder, Special cylinders / large size cylinders can be processed and returned. 914-CPFS-30 30LB CYLINDER SWAP 56.67 REFRIGERANT - HOT SHOT 914-CPFS-50 50LB CYLINDER SWAP 68.00 Hot Shot, R-414B is environmentally, Economically and Technically superior to any other refrigerant in the market today. Hot Shot is the best alternative. R-414B is UL classified, has a nontoxic, nonflammable safety classification. - Fully Compatible with all standard refrigerant lubricants. - No oil changes required at any temperature application. - Near duplication of R-12 characteristics. - No expensive parts retrofits. - 8% more efficient than R-12 - EPA accepted for use in both stationary ALSO REPLACES: R-401A, R409A, R-420A, R-401B, R-416A Recovery Cylinders Meets DOT / OSHA Standards 914-RC30 30LB CYLINDER 264.28 914-RC50 50LB CYLINDER 272.89 EPA REFRIGERANT CERTIFICATION Self-Study Course and mobile equipment EPA approved test for Type I,II,III, and Universal - Receive your EPA Certification card, - Test Course SECTION 608 - (Required to work with R22) material is presented quickly and easily - Price includes EPA certification test and card - 901-HOTSHOT HOTSHOT (R12 DROP-IN)-25# 1025.00 950-T-TEST 608 EPA CERTIFICATION TEST- R22 107.69 NEED TECHNICAL ASSISTANCE ON ANY REFRIGERATION RELATED ISSUE? 950-T-608PM EPA PREPARATORY MANUAL 39.85 950-T-608CD AUDIO CD OF PREP MANUAL 39.85 R410A - (Volutary) Tech2Tech 950-T-410A R-410A CERTIFICATION EXAM 92.31 1.866.433.TECH This service is provided by ICOR International, manufacturers of NU-22, HOT SHOT, and ONE SHOT 950-T-410APM R410A SAFETY & TRAINING MANUAL 64.52 950-T-CD410A R-410A INTERACTIVE TRAINING CD 55.29 11-2

STOP throwing away your empty refrigerant cylinders, and START participating in our cylinder disposal program. We are now accepting any size and any type of used refrigerant cylinders at NO COST. Refrigeration Supplies ACID TEST - QWIKCHECK Fast, accurate, and easy to use, QwikCheck provides an early warning of acid problems. The Yellow to Red color change allows you to easily and clearly communicate the need for action to the equipment owner 950-QT2000 QWIKCHECK ACID TEST KIT 12.60 FILTER DRYERS - LIQUID LINE Filter driers are specifically designed to protect the refrigerant system from liquid and solid contaminants. They incorporate a desiccant specially blended and molded in block form. VALVE CORES R22 & R410 Rated 731-AF2100 MA-LINE 1/4" VALVE CORES - 5PK 5.23 CSI # Size AC Tons Price VALVE CORE TOOL W/CORES 910-083S 3/8" SWEAT 3.0 27.14 910-084S 3/8" SWEAT 6.0 28.71 910-163S 3/8" SWEAT 3.0 31.34 FILTER DRYERS - BI FLOW Designed for heat pump installations. Internal check valves allow flow and filtration in either direction. Filter driers are specifically designed to protect the refrigerant system from liquid and solid contaminants. They incorporate a desiccant specially blended and molded in block form. R22 & R410 Rated CSI # Size AC Tons Price 731-AF2200 MA-LINE 1/4" VALVE CORE TOOL 6.92 COPPER TUBE EXTENSIONS 910-BF083S 3/8" SWEAT 4.0 44.86 910-BF163S 3/8" SWEAT 5.0 59.29 730-40416 ACCESS FTG 1/8"OD TUBE - 5PK 10.31 730-40417 ACCESS FTG 3/16"OD TUBE - 5PK 11.38 FILTER DRYERS - SUCTION LINE 730-40418 ACCESS FTG 1/4"OD TUBE - 5PK 11.23 The SLED Series is a solid core clean-up filter-drier for use in the suction line.the compact design incorporates a large outside diameter shell, which results in a shorter lay-in length, and a larger core, which provides a greater filtration area for maximum operating efficiency. CSI # Size AC Tons Price 730-40419 ACCESS FTG 3/8"OD TUBE - 5PK 14.62 COPPER SADDLE TAP VALVE These saddle taps are designed to allow the addition of an access port without the need to evacuate the system. Solder/Braze the saddle to the existing line and then use the unique design to pierce the line. Perfect for adding pressure switches, or service access. 910-SLD08-5SV 5/8" SW 3.9 #N/A 910-SLD13-6SV-HH 3/4" SW 7.0 46.14 732-STV12 # VLC-8 1/2" SADDLE TAP VALVE 4.67 910-SSSLD16-6SV 3/4" SW 3.2 50.89 732-STV34 # VLC-12 3/4"SADDLE TAP VALVE 5.83 910-SLD13-7SV-HH 7/8" SW 7.0 48.17 732-STV38 # VLC-6 3/8" SADDLE TAP VALVE 4.33 910-SLD27-7SV 7/8" SW 10.0 105.06 732-STV58 # VLC-10 5/8"SADDLE TAP VALVE 5.17 11-3

FAN CYCLE SWITCH Encapsulated pressure switch is designed to cycle condenser fan in low ambient operation. 1/4" female flare connection 18" leads Refrigeration Supplies THERMAL EXPANSION VALVE EXPANSION VALVES Non- Adjustable Internal Check Valve External Equalizer 1/4" Bleed Hole CSI # Cut In Cut Out Price Includes Suction Line Elbow with Port 454-P100AP-4 250 170 49.46 PARKER HCE SERIES LOW PRESSURE SWITCH CSI # Tons Type System Price Encapsulated pressure switch 1/4" female flare connection 18" leads 109-H2TXV01 Up to 3.0 Bleed AC & HP 74.00 109-H2TXV02 Up to 5.0 Bleed AC & HP 74.00 109-H2TXV03 Up to 6.0 Bleed AC & HP 74.00 CSI # Open Close Price 454-PS-LP-10-25 10 20 43.63 REFRIGERATION OIL AC / HP COMPRESSORS Capitol Supplies stocks large number of Copeland replacement compressors from Service Ready Parts warranty division. These compressors are perfect replacement s for out of warranty compressors as well. Call our sales department for more information. LineSeal HVACR Affordable and easy eay to repair small leaks in refrigerant lines & coils 337-5GS REFRIGERATION OIL-1 GAL-525VIS 29.60 THERMAL EXPANSION VALVE EXPANSION VALVES Non- Adjustable Internal Check Valve Equalizer Bleed Hole Permanently seals leaks in condensers, evaporators, and linesets. / Can be used with all oils and refrigerants / Included hose and valve assembly CSI # Tons Type Equalizer System Price 101-X3-3 Upto 3.5 Bleed External AC & HP #N/A 101-X3-5 4.0-5.0 Bleed External AC & HP #N/A THERMAL EXPANSION VALVE 337-944KIT LINE SEAL HVACR-1.5 TO 5.0 T 110.97 EXPANSION VALVES Non- Adjustable Internal Check Valve External Equalizer 1/4" Bleed Hole LIQUID LINE SIGHT GLASS Sight Glass with moisture indicator. Easily check system status. 3/8" for common residential / light commerrcial split systems. PARKER HCE SERIES CSI # Tons Type System Price 454-HCAE3VX100A Upto 3.0 Bleed AC & HP 146.91 910-SITGLS-38 3/8" Liquid Line Sight Glass 23.49 11-4

Refrigeration Supplies PISTON ORIFICE FIXED OPENING METERING DEVICE PRO-FLUSH System Flush Used for R22 to R410 system conversion R22 & R410A SYSTEMS Includes removal hook and teflon seal ring. PRO-Flush as been formulated to provide a flushing agent for HFC systems that is still ozone safe, biodegradable and non-carcinogenic. PRO-Flush effectively removes impurities including oil, sludge, acid and moisture. PRO-Flush is a must for system clean ups and retrofits. CSI # Orifice Size Price 110-10W82 PISTON KIT-.061 9.63 110-10W83 PISTON KIT-.068 11.52 110-10W85 PISTON KIT-.072 11.52 110-10W86 PISTON KIT-.080 11.52 Flushes moisture, oil, acid, and impurities Flushes more oil than R-11 - Absorbs more acid & water than R-11 - Safe for all refrigerants & oils - Flush systems after burn-outs - Flush systems for HCFC to HFC refrigerant conversions Hooks up to your NITROGEN TANK RIG. NITROGEN pushes the FLUSH thru the lineset 110-10W87 PISTON KIT-.084 9.60 110-10W88 PISTON KIT-.088 9.63 110-10W89 PISTON KIT-.090 11.56 337-PFKIT PRO-Flush Kit - Refillable tank, charging hose 209.11 110-10W91 PISTON KIT-.049 5.64 flush nozzle, 16 oz Pro-Flush, pres. Relief valve 110-10W93 PISTON KIT-.051 11.52 337-PF16 PRO-Flush 16 oz refill 102.69 110-10W95 PISTON KIT-.055 6.64 110-10W96 PISTON KIT-.059 11.52 QWIK SYSTEM FLUSH 110-10W99 PISTON KIT-.065 5.92 SELF PRESSURIZED LINSET FLUSH 110-11W00 PISTON KIT-.067 28.40 110-11W01 PISTON KIT-.071 6.97 110-11W04 PISTON KIT-.078 7.00 110-11W06 PISTON KIT-.081 4.50 110-11W08 PISTON KIT-.086 37.51 110-11W14 PISTON KIT-.096 5.44 110-11W15 PISTON KIT-.098 8.36 SERVICE VALVES 337-QT1100 QWIK SYSTEM FLUSH 118.61 337-QT1105 337-QT1105 40.57 CSI # SIZE STYLE Price 337-QT1110 337-QT1110 18.66 110-R100355-01 3/8" 90 DEG 48.13 110-R100354-01 3/4" 90 DEG 69.07 110-R100354-02 7/8" 90 DEG 79.03 Since 1928...Capitol Has It! 110-R100432-01 3/8" STRAIGHT 64.16 110-R100432-02 3/4" STRAIGHT 68.47 110-45494-001 7/8" STRAIGHT 95.40 11-5

NOTES 11-6