PAVIRO EN 54 devices supported by IRIS-Net

Similar documents
1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link -

Flexibility right from the start. PAVIRO Public Address and Voice Evacuation System with Professional Sound Quality. boschsecurity.

Promatrix 6000 I EN de I 1. ISO7240 PAVIRO. Installer checklist

ICP-EZM2. ICP-EZM2 Release Notes F01U Page Bosch Security Systems, Inc.

ONYXWORKS AND FIRSTVISION. Version 4

X-dock Software History

Easy Series Voice Modules

Vocia VACIE. Reference Guide

C e r t i f i c a t e Of Conformity No.: 0560-CPD /AA/05

Get all messages across, no matter what.

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software

The Ultimate, Digital Public Address & Voice Alarm System FLEXIBILITY UNLIMITED

VACUUM FOR HIGHER QUALITY. In plastic injection molding

VACIE REFERENCE GUIDE REVISION 1.2.6

Entero Voice Alarm system.

VACUUM FOR HIGHER QUALITY. In plastic injection molding

Fire Alarm Control Panels FPD-7024

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

16 Zone Voice Evacuation VA & PA Sound System

Bosch Plena Public Address and Voice Alarm System The fast route to safety

SONOCHEK The ultrasonic testing device

Digital Control Systems & Remote Communications Options

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

Innovating security where you need it most. Transportation: License Plate Capture.

PowerRouter application guideline

Bosch Plena Public Address and Voice Alarm System The ease of amplification

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Control System Structure

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

DPM4 Bedside Monitor Default Settings

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

This unique feature seamlessly integrates security into your everyday life to give you safe, simple living with peace of mind.

Innovative protection that combines power and flexibility

u JOSSI FIRE SHIELD U JOSSI METAL SHIELD U JOSSI COMBO SHIELD Technical Data

OPERATING INSTRUCTIONS. G214 Software - Version 4

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Certificate of constancy of performance,

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software

Fire control panels FC360

Certificate of constancy of performance,

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

Entero Voice Alarm system. User guide

LC1 Modular Ceiling Loudspeaker Range. en Installation note

Easy Series Intrusion Control Panel

Building Integration System

LB3 Premium Cabinet Loudspeakers

Bosch Security Systems For more information please visit or send an to

Technical Data Submittal Document

Access Professional Edition. The flexible access control system that grows with your business.

The Omni IIe Controller

Easy Series ICP-EZM2. Quick Start Guide

Programat P310. Operating Instructions. software V3.0. Valid from

Experts in PA/VA Systems

User Manual. Dryer Controller M720

APP Function Introduction

HELPY QUICK-TL GSM INTL

LYNX SE CENTRAL CONTROL FOR NETWORK GDC. General Specifications

IDEAL E-NERGY Thermostat Touch type User Manual

Agilent E6000A E6003A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

Technical Data Submittal Documents

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

B and G Series Integrated Security Solution

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

CSP-204 CSP-208 CSP-104 CSP-108

STERILIZER STEAM - GLOBO 6412 INNOVATING TRADITION

The Global Leader for Safety Signs & Labels COLLABORATION IN A NEW ERA OF VISUAL SAFETY

SIRe Control system. Intelligent Automatically adapts to your entrance. Proactive Anticipates for quicker reactions. Adaptive Expert on your entrance

Memcom Emergency Telephone

Easy Series Control Panel ICP-EZM2

Complete control. Being far, feeling close

F8 Fingerprint &RFID card Access Control system

INTELLICOMFORT CH180WIFI TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION FOR REMOTE CONTROL

Intelligent security solutions UNCOMPROMISED SECURITY FOR YOUR COMPANY ALARM CONTROL PANEL INTEGRA

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

User manual. KNXgal. version

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

Vcare. User Manual. Ver WiFi - GSM- App. Smart Home Security System

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Controller PCSol 300 FOR SOLAR COLLECTORS. INSTALLATION AND OPERATION MANUAL 62.X.2 REVISION SOFTWARE

LC4 Wide Angle Ceiling Loudspeaker Most compact. Widest impact.

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

LB3-PCx50 Premium Cabinet Loudspeakers

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

Options for Diesel Fire Pump Controllers

FiRe mobile-2 Operation Manual

MegaPower CPU ADMPCPU

Alarm module for leak detection with webserver

Easy Series Intrusion Control Panel

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

Advisor Advanced Mobile Application User Manual

Applications and Examples

IDoorBell Fon DP68 Quick Installation Guide

Please use authentic SATA hard drive, USB device and battery.

Modular Fire Panel 5000 Series Just as flexible as your plans

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

DIGITAL LOCKING SOLUTION

Installation, Configuration and User Manual

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

alarm system VERSA Plus

NC 100. Vertical Steam Sterilizer

Transcription:

PAVIRO EN 54 devices supported by IRIS- en Software manual

PAVIRO Table of contents en 3 Table of contents 1 About this document 4 1.1 Document history 4 2 EN 54 devices supported by IRIS- 5 3 History 6 3.1 IRIS- V3.2.0 6 3.2 IRIS- V3.1.4 7 3.3 IRIS- V3.1.0.1 8 3.4 IRIS- V3.0.1 9 Bosch Security Systems Software manual 2018.02 V1.0 EN 54 devices supported by IRIS-

4 en About this document PAVIRO 1 About this document This document lists the PAVIRO Voice Alarm System devices that IRIS- supports. It shows the relationship between IRIS- and the corresponding firmware versions that can be used for EN 54 compliant voice evacuation systems. IRIS- versions which are not listed cannot be used for: Voice Alarm purposes, including EN 54, or any other Voice Evacuation application. We recommend that you use the most recent firmware and configuration software versions when setting up a new evacuation system. These versions include the latest bug fixes and optimizations. Previous firmware versions will only be updated if critical firmware issues have to be corrected. The certified PAVIRO system devices and their supported options are listed in the corresponding DoP. 1.1 Document history Release date Documentation version Reason 2018.02 V1.0 1 st edition. 2018.02 V1.0 EN 54 devices supported by IRIS- Software manual Bosch Security Systems

PAVIRO EN 54 devices supported by IRIS- en 5 2 EN 54 devices supported by IRIS- This section lists: all IRIS- related firmware for PAVIRO that is delivered with IRIS- V3.2.1 and V3.2.2, and the changes compared to previous versions. The certified devices and supported options are listed in the corresponding DoP: DECL DoP EN54-16 EN54-4 PAVIRO V11 IRIS- supported devices/modules PVA-4CR12 and PVA-4R24 PVA-2P500 PVA-15CST PVA-15ECS OM-1 Devices with firmware Product Firmware version Comments PVA-4CR12 V1.19.1 Bug fix where a gain change in the configuration software could lead to a watchdog reset. Bug fix where EOL (End Of Line) stays deactivated when an EOL module gets lost during a running EVAC signal. PVA-4R24 PVA-2P500 PVA-15CST / PVA-15ECS OM-1 V1.5.0 V1.1.0 V2.3.0 V1.15.118 Configuration software note V3.2.2 does not provide updates for PAVIRO. IRIS- V3.2.2 and V3.2.1 are identical for PAVIRO. IRIS- V3.2.1 and V3.2.2 are patch updates which require IRIS- V3.2.0 to be installed up front. Bosch Security Systems Software manual 2018.02 V1.0 EN 54 devices supported by IRIS-

6 en History PAVIRO 3 History 3.1 IRIS- V3.2.0 This section lists: all new IRIS- related firmware for PAVIRO that is delivered with IRIS- V3.2.0, and the changes compared to previous versions. The certified devices and supported options are listed in the corresponding DoP: DECL DoP EN54-16 EN54-4 PAVIRO V10 New IRIS- supported devices/modules OM-1 PVA-15ECS Devices with firmware Product Firmware version Comments PVA-4CR12 V1.19.0 TCP/IP work support added for up to 4 controllers. OM-1 module support for IP audio transport. PAVIRO can be networked by up to 4 controllers. Improved password protection. Smart safety link configurable from wizard. PVA-4R24 V1.5.0 Functions added with respect to network functionality. PVA-15CST / PVA-15ECS OM-1 V2.3.0 One touch LED test added. V1.15.118 Talk over Alarm added. Configuration software note IRIS- V3.2.0 is a full package that can be downloaded from the BOSCH website. 2018.02 V1.0 EN 54 devices supported by IRIS- Software manual Bosch Security Systems

PAVIRO History en 7 3.2 IRIS- V3.1.4 This section lists: all new IRIS- related firmware for PAVIRO that is delivered with IRIS- V3.1.4, and the changes compared to previous versions. The certified devices and supported options are listed in the corresponding DoP: DECL DoP EN54-16 EN54-4 PAVIRO V9 New IRIS- supported devices/modules No additional devices added. Devices with firmware Product Firmware version Comments PVA-4CR12 V1.17.4 Non EN 54-16 features added. Fixes a critical bug solved for FW versions 1.17.11, 1.17.2, and 1.17.3. Bug fix that limited the number of EOL (End Of Line) to 254. Busy condition block bug fixed. Low bandwidth connection improved. PVA-4R24 V1.4.4 Bug fixing with respect to temperature control. PVA-15CST V2.2.7 Supervision bug fixed. Configuration software note IRIS- V3.1.4 is a patch update which requires IRIS- V3.1.0.1 to be installed up front. Additional comments: IRIS- versions 3.1.0 to 3.1.3 are withdrawn and shall not be used anymore. Bosch Security Systems Software manual 2018.02 V1.0 EN 54 devices supported by IRIS-

8 en History PAVIRO 3.3 IRIS- V3.1.0.1 This section lists: all new IRIS- related firmware for PAVIRO that is delivered with IRIS- V3.1.0.1, and the changes compared to previous versions. The certified devices and supported options are listed in the corresponding DoP: DECL DoP EN54-16 EN54-4 PAVIRO V9 New IRIS- supported devices/modules No additional option added. Devices with firmware Product Firmware version Comments PVA-4CR12 V1.17.02 Bug fixes and critical bug solved. PAVIRO wizard bug update. Separate Stop signal for messages / alarms option added in wizard. Voice Evacuation recording. Busy Condition block added to Task Engine. PVA-4R24 V1.4.0 Bug fixing. PVA-15CST V2.2.0 Audio monitoring added. Languages added: French, Spanish, Italian, Portuguese, Polish, Finnish, Russian, Turkish, Czech, Korean and Chinese. PTT talk priority change programmable for EVAC purposes. Configuration software note IRIS- V3.1.0.1 is a full package that can be downloaded from the BOSCH website. Additional comments: IRIS- versions 3.1.0 to 3.1.3 are withdrawn and shall not be used anymore. 2018.02 V1.0 EN 54 devices supported by IRIS- Software manual Bosch Security Systems

PAVIRO History en 9 3.4 IRIS- V3.0.1 This section lists: all new IRIS- related firmware for PAVIRO that is delivered with IRIS- V3.0.1, and the changes compared to previous versions. The certified devices and supported options are listed in the corresponding DoP: DECL DoP EN54-16 EN54-4 PAVIRO V5 New IRIS- supported devices/modules PVA-4CR12 PVA-4R24 PVA-2P500 PVA-15CST Devices with firmware Product PVA-4CR12 PVA-4R24 PVA-2P500 PVA-15CST Firmware version V1.16.2 V1.3.0 V1.1.0 V2.1.2 Comments Configuration software note IRIS- V3.0.1 is a patch update which requires IRIS- V3.0.0 to be installed up front. Bosch Security Systems Software manual 2018.02 V1.0 EN 54 devices supported by IRIS-

Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven herlands www.boschsecurity.com Bosch Security Systems B.V., 2018