Installation Instructions

Similar documents
Small Digital Thermostat Controller Temperature Control

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

Installation Instructions

5+2 Day. up to HEAT COOL

T500 Series Non-Programmable Thermostats

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Installation Instructions

TEC210x-2 Series Networked Thermostats

Installation, Start-Up, and Operating Instructions

TEC2100 Series Networked Thermostats

Installation Instructions HEAT COOL FAN POWER

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00

Owner s Manual. Digital Thermostat. Non-Programmable

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

Non-Programmable Digital Thermostat

Owner s Manual. Digital Thermostat

TEC1100 Series Thermostats

Installation Instructions

2 - Wire Programmable Digital Thermostat

7-Day. Digital Thermostat. residential. & 2-cool

OWNER'S MANUAL T0140. Contents Page #

P266 Series Single-Phase Condenser Fan Speed Control

Programmable 5-2 Day Digital Thermostat

WARNING Important Safety Information

SC Installation, Operation & Application Guide

Safety & Installation Instructions

XFlat Blade. Installation Instructions DIGITAL THERMOSTAT 53DFS250-SL. CoolingOnly,Heat Cool,and Heat Pump MULTI-STAGE SEVEN DAY PROGRAMMABLE

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

T-32-TS Touchscreen Thermostat. Installation Manual

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

asy Single Day up to 2-heat & 2-cool Stat

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

WARNING Important Safety Information

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

ELECTRONIC COMMUNICATING THERMOSTAT

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

SC Installation, Operation & Application Guide

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCNB001 TSTATBBNB001 P Digital Thermostat

HEAT HEAT HEAT COOL COOL

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

Surface-Mounted NS Series Network Sensors without LCD

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

Installation & Operation Manual

tcu.z Commercial Programmable Thermostat Installation Instructions

Installation & Operation Manual

Smart Temp. ApolloP/n Installation Manual. Version 1.0

WARNING Important Safety Information

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Installation & Operation Manual

TEC Networked Multi-Stage Thermostat

WARNING Important Safety Information

T62xx-0 Fan Coil Retrofit Thermostat Controller and R-xxxxx-0 Fan Coil Retrofit Relay Packs

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

Installation & Operation Manual

Installation & Operation Manual

CT2800 Programmable Thermostat

7-Day. Digital Thermostat. residential. & 2-cool

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Installation Manual for Hot Yoga Studio Electric Radiant Heating

SEE DISCLAIMER ON REVERSE

F261 Series Fluid Flow Switches

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03

5+2 Day. up to HEAT COOL

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

T606MSx-4 and T606MSx-4+PIR Series Multi-Stage

SC Installation, Operation & Application Guide

WARNING Important Safety Information

MR3CCUHV Temperature/Defrost Control

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

3M Benchtop Air Ionizer 963E. User s Guide

Model Smart Digital Humidistat

Owner s Manual. 5+2 Day Programmable Digital Thermostat

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD

SC Installation, Operation & Application Guide

TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

CT500 Electronic Thermostat

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T600MEP-2 Programmable Economizer Thermostat

NS Series Network Sensors

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

Digital Programmable

Owner s Manual. Premier Series Digital Thermostat. and Installation Instructions. Non-Programmable with Humidity Control COMMERCIAL

HEAT HEAT PUMP TOTALINE. Installation Instructions DIGITAL THERMOSTAT MODEL P FM. I2:00 Mo COOL

Installation Instructions

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Installer Guide smart connect

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

Installer Guide. WARNING Important Safety Information. 1 Specifications

SC Installation, Operation & Application Guide

Transcription:

2 or 4 pipe systems model T701DFP-1 Fan Coil Thermostat 7-Day Programmable Thermostat Remote sensor ready Self-prompting programming Auto 2-pipe changeover when used with accessory changeover sensor Dry contact equipped Backlit display One For All TM works with most all fan coil systems Electric heat ready Non-volatile memory Dual setpoint with adjustable deadband Keypad lockout Configurable display Display either F or C Installation Instructions

TABLE OF CONTENTS Step #1: Preparation 2 Step #2: Applications 3 Step #3: Wire Connections 4 Step #4: Test Operation 6 Troubleshooting 11 Sample Wiring Diagram 14 CAUTION Follow Installation Instructions carefully. Disconnect Power to the Heater/Air Conditioner before removing the old thermostat and installing the new thermostat. WARNING IMPORTANT: The T701DFN-1 and T701DFP-1 Series Thermostat Controllers are intended to provide an input to equipment under normal operating conditions. Where failure or malfunction of the thermostat controller could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn or protect against failure or malfunction of the thermostat controller. P/N T701DFP-1 Copyright 2010, All Rights Reserved Page 1

STEP #1 PREPARATION Proper installation of the thermostat will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. Assemble tools. Flat Blade Screwdriver Wire cutter & Stripper Drill with 3/16 inch Drill Bit (when not using j-box) Make sure your Heater/Air Conditioner is working properly before beginning installation of the thermostat. Carefully unpack the thermostat. Save the screws, wall anchors, and instructions. Turn off the power to the Heating/Air Conditioning system at the main fuse panel. Installation Location Considerations Locate the T701 Series Thermostat Controller: on a partitioning wall, approximately 5 ft (1.5 m) above the floor in a location of average temperature. away from direct sunlight, radiant heat, outside walls, outside doors, air discharge grills, or stairwells; and from behind doors. away from steam or water pipes, warm air stacks, unconditioned areas (not heated or cooled), or sources of electrical interference. Page 2

STEP #2 APPLICATIONS New Applications Follow the thermostat and E-M (Electro-Mechanical) wiring diagrams supplied with the submittal package, and afixed to the fan coil unit enclosure. Go to pages 6 through 10 for instructions to test operation for the available applications. Existing Applications Remove the cover of the old thermostat. If it does not come off easily check for screws. Loosen the screws holding the thermostat base or subbase to the wall and lift away. Disconnect the wires from the old thermostat. Tape the ends of the wires as you disconnect them and mark them with the letter of the terminal for easy reconnection to the new thermostat. Keep the old thermostat for reference purposes until your new thermostat is functioning properly. CAUTION: Risk of Electric Shock. Disconnect power supply before making electrical connections to avoid electric shock. CAUTION: Risk of Property Damage. Do not apply power to the system before checking all wire connections. Short circuited or improperly connected wires may result in permanent damage to the equipment. IMPORTANT: Make all wiring connections in accordance with local, national, and regional regulations. Do not exceed the electrical ratings of the T701 Series Thermostat Controller. Note: This thermostat is strictly a low voltage control. A compatible relay board must be installed to isolate the 24 volt wires from the line voltage to the fan. Page 3

STEP #3 WIRE CONNECTIONS If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below. 4-PIPE SYSTEMS Wire from the old thermostat terminal marked Y1, Y or C W1, W or H Rh, R, M, Vr, A C G, F or LOW MED HIGH Function Cooling Heating Power Common Low Fan Speed Medium Fan Speed High Fan Speed Install on the new thermostat terminal marked Y1 W1 R C G G2 G3 Note: Be sure to seal any opening through the wall behind the thermostat with fireproof material to prevent improper temperature sensing of the conditioned space. Page 4

STEP #3 WIRE CONNECTIONS If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below. 2-PIPE SYSTEMS Wire from the old thermostat terminal marked Y1, Y or C W1, W or H Rh, R, M, Vr, A C G, F or LOW MED HIGH Function Water Valve Strip Heater Power Common Low Fan Speed Medium Fan Speed High Fan Speed Install on the new thermostat terminal marked Y1 W1 R C G G2 G3 Note: Be sure to seal any opening through the wall behind the thermostat with fireproof material to prevent improper temperature sensing of the conditioned space. Page 5

STEP #4 TEST OPERATION 4-PIPE SYSTEM Turn the power on to the Fan Coil Unit. Press the MODE button repeatedly until the HEAT icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees above room temperature. The hot water valve will open and the fan will be running. Press the MODE button repeatedly until the COOL icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees below room temperature. The cold water valve will open and the fan will be running. Press the UP button until the setpoint is equal to the room temperature. Press the Fan button repeatedly until a single bar appears next to the Fan icon. Confirm the fan is running on low speed. Press the Fan button again, confirm the fan is running on medium speed. Again, press the Fan button, confirm the fan is running at high speed. Press the Fan button once more, the bars next to the Fan icon should disappear. Press the MODE button repeatedly until the OFF icon appears on the display. Both valves will be closed and the fan will be off. Page 6

STEP #4 TEST OPERATION 2-PIPE, CHANGEOVER SENSOR, NO STRIP HEAT Turn the power on to the Fan Coil Unit and confirm that the thermostat is programmed correctly in setup steps #5 and #6 on page 19 of the Owner s Manual. If hot water is available, press the MODE button repeatedly until the HEAT icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees above room temperature. The hot water valve will open and the fan will be running. If cold water is available, press the MODE button repeatedly until the COOL icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees below room temperature. The cold water valve will open and the fan will be running. Press the UP button until the setpoint is equal to the room temperature. Press the Fan button repeatedly until a single bar appears next to the Fan icon. Confirm the fan is running on low speed. Press the Fan button again, confirm the fan is running on medium speed. Again, press the Fan button, confirm the fan is running at high speed. Press the Fan button once more, the bars next to the Fan icon should disappear. Press the MODE button repeatedly until the OFF icon appears on the display. Both valves will be closed and the fan will be off. Page 7

STEP #4 TEST OPERATION 2-PIPE, NO CHANGEOVER SENSOR Turn the power on to the Fan Coil Unit and confirm that the thermostat is programmed correctly in setup steps #5 and #6 on page 19 of the Owner s Manual. If Heat Only, press the MODE button repeatedly until the HEAT icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees above room temperature. The hot water valve will open and the fan will be running. If Cool Only, press the MODE button repeatedly until the COOL icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees below room temperature. The cold water valve will open and the fan will be running. Press the UP button until the setpoint is equal to the room temperature. Press the Fan button repeatedly until a single bar appears next to the Fan icon. Confirm the fan is running on low speed. Press the Fan button again, confirm the fan is running on medium speed. Again, press the Fan button, confirm the fan is running at high speed. Press the Fan button once more, the bars next to the Fan icon should disappear. Press the MODE button repeatedly until the OFF icon appears on the display. Both valves will be closed and the fan will be off. Page 8

STEP #4 TEST OPERATION 2-PIPE, CHANGEOVER SENSOR, WITH STRIP HEAT Turn the power on to the Fan Coil Unit and confirm that the thermostat is programmed correctly in setup steps #5 and #6 on page 19 of the Owner s Manual. If hot water is available, press the MODE button repeatedly until the HEAT icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees above room temperature. The hot water valve will open and the fan will be running. The strip heat will be locked out if hot water is available. If hot water is not available, but your unit is equipped with a strip heat system, press the UP or DOWN buttons until the set temperature is 10 degrees below room temperature. The unit should energize the strip heaters and the fan will be running. If cold water is available, press the MODE button repeatedly until the COOL icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees below room temperature. The cold water valve will open and the fan will be running. Page 9

STEP #4 TEST OPERATION 2-PIPE, CHANGEOVER SENSOR, WITH STRIP HEAT Press the UP button until the setpoint is equal to the room temperature. Press the Fan button repeatedly until a single bar appears next to the Fan icon. Confirm the fan is running on low speed. Press the Fan button again, confirm the fan is running on medium speed. Again, press the Fan button, confirm the fan is running at high speed. Press the Fan button once more, the bars next to the Fan icon should disappear. Press the MODE button repeatedly until the OFF icon appears on the display. Both valves will be closed and the fan will be off. Page 10

TROUBLESHOOTING SYMPTOM: The fan will not run in all three speeds or switches speeds in an improper order. CAUSE: Incorrect wiring between the thermostat and the relay board, or between the relay board and the fan wires. REMEDY: Recheck the wiring (G=low speed, G2=medium speed, G3=high speed). SYMPTOM: Cold water valve opens for either a cool or a heat demand in a 4-pipe system. CAUSE: The thermostat has been programmed for the incorrect type of fan coil. REMEDY: Confirm that you have entered the correct programming for your type of fan coil system (steps #5 and #6, page 19 of the Owner s Manual). SYMPTOM: The water valve does not open at all in 2-pipe configurations. CAUSE: The thermostat has been programmed for the incorrect type of fan coil system or the fan coil is not wired to the thermostat correctly. REMEDY: Program the thermostat for a 2-pipe fan coil (step #5, page 19 of the Owner s Manual). Also, make certain that the water valve is wired to the Y1 terminal. SYMPTOM: The thermostat display only shows clock. CAUSE: The thermostat has been programmed for a minimal display. REMEDY: Program the thermostat for Full Display (step #3, page 18 of the Owner s Manual). Page 11

TROUBLESHOOTING SYMPTOM: The thermostat displays large setpoint digits instead of the room temperature. CAUSE: The thermostat has been programmed to display Single Setpoint. REMEDY: Program the thermostat to display Dual Setpoint (step #4, page 19 of the Owner s Manual). SYMPTOM: The thermostat display flashes Occupied 1 when running the program. CAUSE: The sensor connected to the Dry Contact terminals of the thermostat, is active, forcing the unit into Occupied 1. REMEDY: Verify proper wiring between the thermostat and the occupancy sensor and verify that the wiring is not shorted. If no sensor is connected, program the Dry Contact polarity for Normally Open (step #14, page 21 of the Owner s Manual). Page 12

TROUBLESHOOTING SYMPTOM: The thermostat will only allow Heat or Off in 2-pipe installations, even though chilled water is available. CAUSE: Faulty, improperly wired, or improperly installed H2O changeover sensor. REMEDY: Confirm proper wiring of the changeover sensor (between R and H2O). Confirm proper placement of the sensor (good mechanical coupling for temperature transfer). Test the changeover sensor as follows: 1. Remove power from the fan coil system. 2. Disconnect the wire between the sensor and the H2O terminal. 3. Place an ohmmeter between R and the wire just disconnected from the sensor. 4. A good sensor will show continuity whenever the water temperature is confirmed to be at or below 65 degrees. If the sensor is open when the water temperature is confirmed to be at or below 65, replace the sensor. Page 13

SAMPLE WIRING DIAGRAM 2-Pipe, Low Voltage Valve, H2O Changeover Sensor Duct Sensor SEN-700-1 *NOTE: Thermostat RS R G Y1 G3 G2 C H2O WHITE BLACK Important Note: If a Duct sensor is connected to this thermostat it is suggested that the fan be programmed for continuous operation. *NOTE: R wire from sensors should be connected as close as possible to thermostat terminal plate. V 24 Volt Water Valve R S1S2 R C C Y1 W1Y2 G H M L L2/NEUT 115 EH RELAY COIL HEAT COM H2O Changeover Sensor RELAY BOARD 115 208 208 230 203 277 277 LINE VOLTAGE INPUTS MTR PWR TO FAN MOTOR NEUT HIGH MED LOW SPEED SELECT 24 VAC R LOW MED HIGH R COM Page 14

TECHNICAL SPECIFICATIONS T701 Series Thermostat Controllers Power Requirements 20-30 VAC 50/60 Hz, 3 VA @ 24V nominal. Output Rating (fan or valve outputs) 0.4A max, 0.01A min, 3A inrush, 20-30 VAC Digital Inputs H2O voltage free contacts, closed to signal CHILLED water supply Local Temperature Sensor Type CK1 Remote Temperature Sensor Type Wire Size Temperature Adjustment Range Accuracy voltage free contacts, closed to alter setpoints solid state temperature sensor, 10 mv / degf solid state temperature sensor, digital communications over two wires, 5 ft cable supplied, accurate to 1 degf 16 AWG (100 ft max) to 24 AWG (36 ft max) 35 to 99 degf (2 to 36 degc) 35 to 65 degf +/- 3 degf, greater than 65 to less than 80 degf +/- 2 degf, 80 to 99 degf +/- 3 degf, greater than 99 to 104 degf +/- 5 degf Deadband Ambient Conditions Operating Storage Adjustable 1 to 6 deg first stage, fixed 1 degree for med/hi fan speeds 35 to 104 degf (2 to 40 degc), 5 95% RH non-condensing, 86 degf max dew point -22 to 122 degf (-30 to 50 degc), 5 95% RH non-condensing, 86 degf max dew point Compliance UL/CUL listed, file E107041, NEC Class 2 Dimensions Shipping Weight 3.14 H x 3.14 W x 1.1 D 0.25 kg North American Emissions Compliance United States This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. Canada This Class (A) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numerique de la Classe (A) respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada. P/N 88-825 Rev. 1L