AMSCO CENTURY MEDIUM STEAM STERILIZER 26 X 37.5" NORTH AMERICA

Similar documents
AMSCO EVOLUTION STEAM STERILIZERS - NORTH AMERICA

AMSCO CENTURY SMALL STERILIZERS DOMESTIC

AMSCO CENTURY MEDIUM STEAM STERILIZER 26" X 37.5" (SCIENTIFIC)

AMSCO CENTURY MEDIUM STEAM STERILIZER 26 X 26" (SCIENTIFIC)

AMSCO C SERIES SMALL STEAM STERILIZERS DOMESTIC

AMSCO REMANUFACTURED MEDIUM STERILIZERS

Open the Door to Increased Productivity and Cost Efficiency

Control Operating Costs. Gain Process Efficiency.

AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM (For Use Outside U.S.A. Only)

RELIANCE 400 LABORATORY GLASSWARE WASHER

Integrity 270 Integrity 270VP INTEGRITY STEAM STERILIZER INTRODUCTION

AMSCO C Series Small Steam Sterilizers 16 x 16" (406 x 406mm) 20 x 20" (508 x 508 mm)

Sterilizer Model LS2020 Series Beta Star Life Science Products of R-V Industries

BASIL 6000 TUNNEL CAGE WASHER

Castle. Model 233HC Vacuum and Gravity Steam Sterilizer for Healthcare Applications. data and specifications

BASIL 6700 TUNNEL CAGE WASHER

VHP ARD BIODECONTAMINATION SYSTEM

OPERATOR MANUAL Amsco Eagle 3000 Series FLJ Floorloading Vacamatic Sterilizers. (10/05/01) P Rev. 7

OPERATOR MANUAL Amsco Century TM Medium Steam Sterilizer 26" x 26" (660 x 660 mm) Scientific. (07/16/07) P Rev. 0

VS LD series vertical steam sterilizers

VISION 1321/1327 CART AND UTENSIL WASHER/DISINFECTOR

AZTECA A LITRE STERILISER

Standard Features: Gravity: Prevacuum:

LSII /51 STERILIZER MACHINE SPECIFICATION A REV DATE REVISION BY CHK APP 0 5/18/2016 RELEASED FOR INFORMATION JPK GBJ KWH

AUTOMATIC STERILIZERS

Accessible. Durable. Smart.

RELIANCE VISION SINGLE-CHAMBER WASHER/DISINFECTOR

SMALL STERILIZER SERIES 26 x 26 MODEL

RELIANCE 444 SINGLE-CHAMBER WASHER/DISINFECTOR

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET

BASIL 9502 CAGE AND RACK WASHER

VHP M100 Biodecontamination Systems: Closed Loop

cgmp STEAM STERILIZERS

ESTEEM AUTOCLAVE SLIDING SINGLE DOOR:-

VHP ARD Mobile Biodecontamination System

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

RELIANCE EPS ENDOSCOPE PROCESSING SYSTEM (For Use In U.S.A. Only)

VHP M100 BIODECONTAMINATION SYSTEM

RELIANCE 580 PHARMACEUTICAL GRADE WASHER

RELIANCE 680PG PHARMACEUTICAL GRADE WASHER

HARMONY LED385 EXAMINATION LIGHTING SYSTEM

HAMO T-420 PHARMACEUTICAL GRADE WASHER SIEMENS PC CONTROL

TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

Revitalize Building Mechanical Systems (4619)

NC SERIES. Horizontal Steam Sterilizers

Instrument Processing. Midmark Animal Health Products

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

laboratory & sterilization technology

Across-the-Line SERIES MP300 Combined Manual and Automatic

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

VHP M100 Biodecontamination Systems

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

Variable Frequency Drive SERIES MP800 VFD

Large Steam Sterilizers for Life Sciences

Soft Start Series MP700 Solid State, Reduced Voltage

W-750-IS Specifications

SECTION STEAM CONDENSATE PUMPS

SMALL STERILIZER SERIES LSII MODEL (20 x 20 )

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

CAREL heatersteam Electric Element Steam Humidifiers

STEAM STERILIZER SERIE S1000 (RBE)

OT 300/430/570 STEAM STERILIZERS

Available from. M3 ULTRAf AST. Phone (502) Toll-free (800) Online

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

MIDMARK INSTRUMENT PROCESSING

GIRTON CABINET WASHER MODEL 794A

Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

OT 300/430/570/710/850 STEAM STERILIZERS

Power Flame Incorporated

SECTION ROTARY-SCREW WATER CHILLERS

MST sterilizer overview

Model GW1020 Laboratory Glassware Washer General Specifications

Introducing The Reliance 200 and 250 Glassware Washing Systems.

Version 7 1/ LXP

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

The Reliance 400/500 Glassware Washers

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

RHP120 RHP300 Steam Boiler Series

M4.9. NO LONGER IN PRODUCTION Some service parts may not be available for this product- Service and Parts Manual M4.9-0

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

RELIANCE ENDOSCOPE PROCESSING SYSTEM (For Use In EUROPE Only)

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

RELIABLE. The Midmark M9 and M11 UltraClave Automatic Sterilizers - make sterilization reliable and efficient.

Operations Manual. Part Number: For Research Use Only

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Commercial Semi-Instantaneous Water Heaters

Air Compressor Network compressed air (standard) R Compressor (built-in the equipment) R Compressor (separately)

OJD ITB No Attachment E Duress Alarm Equipment Specifications

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Tabletop 2340 EA-D Class S Autoclave 19 Litres

SECTION AUTOMATIC TRANSFER SWITCHES

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

Version 7 1/ LX

Consolidated Sterilizers Designed to Transform Your Laboratory

"ESDDR" Series Electric Humidifier

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

Transcription:

AMSCO CENTURY MEDIUM STEAM STERILIZER 6 X 37.5" NORTH AMERICA APPLICATION Two configurations are available for sterilization of heat- and moisture-stable materials used in healthcare facilities: Prevacuum designed for fast, efficient sterilization of heat- and moisture-stable materials. Prevacuum configuration sterilizers are equipped with prevacuum, gravity, liquid, leak test and daily air removal (Bowie-Dick) test cycles. Steam Flush Pressure Pulse (SFPP) designed for fast, efficient sterilization of heat- and moisturestable materials. This configuration uses the Steam Flush Pressure Pulse cycle, which features an aboveatmospheric pressure level conditioning phase. SFPP sterilizers are equipped with SFPP, WRAP/SFPP (for wrapped items), prevacuum, gravity, liquid, leak test and daily air removal (Bowie-Dick) test cycles. Hinged-Door Model ( only - some details may vary.) Horizontal Sliding-Door Model DESCRIPTION Amsco Century Medium Steam Sterilizers are equipped with the latest features in both state-of-the-art technology and ease of use. Primary Product Features Interior Chamber Dimensions 6x37.5x36"(660x950x910 6 x 37.5 x 48" (660 x 950 x 10 6 x 37.5 x 60" (660 x 950 x 150 The Selections Checked Below Apply To This Equipment Type Prevacuum Steam Flush Pressure Pulse (SFPP) Size 6 x 37.5 x 36" (660 x 950 x 910 mm, single door only) 6 x 37.5 x 48" (660 x 950 x 10 6 x 37.5 x 60" (660 x 950 x 150 Steam Source Building Steam Vacuum Pump Electric Service 08/40 VAC, 60 Hz, 3-Phase, 6A per phase 480 VAC, 60 Hz, 3-Phase, 3A per phase Door Configuration Single-Door Hinged Horizontal-Sliding Select direction of door swing or slide to open, as viewed from the sterilizer operating end: Left-Hand Right-Hand (not available for sliding-door units) Double-Door* Hinged Door NOTE: Operating End hinge position listed first; Non-operating End hinge listed second. Right-Hand/Left-Hand Right-Hand/Right-Hand Left-Hand/Right-Hand Left-Hand/Left-Hand Horizontal-Sliding Door NOTE: Operating end slide direction listed first; Non-operating end slide direction listed second. Left-Hand/Right-Hand Single-door Mounting Cabinet Enclosed/Freestanding Recessed Double-door Mounting Recessed through One Wall Recessed through Two Walls * 6 x 37.5 x 36" sterilizers not available in double-door configuration. Accessories 36" (910 Chamber Length 48" (10 Chamber Length 60" (150 Chamber Length Loading Car Transfer Carriage Chamber Track Assembly Single Door Double Door Loading Car, Transfer Carriage, and Track Assembly Single Door Double Door (36" Units only) Chamber Rack and Shelf Seismic Tie-Down Kit Remote Monitoring ProConnect Response Center (Remote Monitoring, Priority Technical Support, Customer Care Center Access, Equipment Performance Reports) Item Location(s) SD74 (11/01/10)

48" and 60" configurations include the choice of a single or double door; 36" configuration provides single door only. Hinged door with fast operating, low-effort door lock mechanism. Door handle lock lever requires a single 30 handle movement to lock or unlock. Horizontal-sliding door with quiet, motor-driven cable and pulley mechanism. Door travels horizontally right to left to open, and is controlled from the touch screen. Century control system with enhanced functionality and userfriendly interface screen. Touch-sensitive screen with 30-line x 40-character display area. Ink-on-paper impact printer. Help screens for programming and troubleshooting alarm conditions. Automatic check of control program and cycle data maintains process integrity. Vacuum pump is supplied on all units to pull the chamber to specified vacuum levels effectively, as well as reduce water consumption. STANDARDS Each sterilizer meets the applicable requirements of the following listings and standards, and carries the appropriate symbols: Underwriters Laboratory (UL) Standard 61010-1 as certified by ETL Testing Laboratories, Inc. Canadian Standards Association (CSA) Standard C., No. 1010. ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME Form U-1 is furnished. Shell and door are constructed to withstand working pressure of 45 psig (3.1 bar). FEATURES 6 x 37.5" chamber cross-section is sized to allow for efficient, high-volume processing of sterilization. Fast-operating, low-effort manual door lock mechanism (hinged-door models) allows door to be locked or unlocked using a single 30 handle motion. Horizontal-sliding power door is controlled from the touch screen display. The door slides horizontally on a rigid rail assembly housed within stainless-steel paneling. Door drive system consists of a cable and pulley arrangement driven by an electric motor. Resistive Thermal Detectors (RTD) are installed for sterilizer temperature control. The dual element chamber drain line RTD senses and controls temperature variations within the sterilizer chamber. A jacket RTD provides temperature control within the jacket space. These RTD signals, converted into electrical impulses, provide accurate control inputs and readouts throughout the entire cycle. Electronic water saving control includes an RTD to control the amount of water used in condensing the exhausted chamber steam. Software calibration is performed in the service mode, accessible through the touch screen displays, and accomplished using external or internal temperature and pressure sources. Control system provides a printed record of all calibration data for verification to current readings. Automatic utilities start-up/shutdown permits utilities conservation. Shutdown may be programmed to activate at the end of any designated cycle or time of day. When activated, the control system automatically shuts off all utility valves, conserving steam and water usage. Sterilizer utilities can be restarted either by programmed time or manual operation. A different shutdown and restart time can be programmed for each day. Steam purge feature is provided to assist in air removal and to preheat the load. Two-piece insulation sleeve is fitted around the exterior of the sterilizer vessel. The sleeve is sealed and held in place by hook-and-loop closures. Insulation is asbestos-free and chloride-free, silicone impregnated, oil- and water-resistant fiberglass. Lighted DIN connectors are installed on all steam, water and exhaust valves, for reliability and ease of maintenance. ProConnect Response Center - Minimize response time and minimize unscheduled downtime on your equipment. Secure, internet-based, 4/7 remote monitoring enables both Predictive Maintenance as well as instant alert to STERIS when there is an equipment alarm. Also included are priority technical support, online parts ordering, equipment performance dashboards and scheduling service at eservice.steris.com. PROCESSING CYCLES All processing cycles factory programmed into the sterilizer control have been validated to AAMI ST8. Prevacuum configuration sterilizers are factory programmed with the following cycles: 70 F (13 C) Prevacuum (with either 5-minute or 0-minute dry phases), Gravity, Liquid, 75 F (135 C) Prevacuum and Test Cycles. SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles. See cycle descriptions below for more details: 70 F (13 C) Prevacuum Cycle: For efficient, highvolume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization.» Sterilize temperature: 70 F (13 C)» Sterilize time: 4 minutes» Dry time: 5 minutes or 0 minutes 50 F (11 C) Gravity Cycle: For sterilizing fabrics.» Sterilize temperature: 50 F (11 C)» Sterilize time: 30 minutes» Dry time: 15 minutes NOTE: A gravity cycle, adjusted to 70 F for 5-minute sterilize exposure time, can be used for processing fabric packs. 70 F (13 ) Gravity Cycle: For sterilizing hard goods.» Sterilize temperature: 70 F (13 C)» Sterilize time: 15 minutes» Dry time: 30 minutes NOTE: 70 F temperature must be set by the user. NOTE: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.

» Sterilize temperature: 70 F (13 C)» Sterilize time: 4 minutes» Dry time: 0 minutes WRAP/SFPP Cycle: For efficient, high-volume processing of heat- and moisture-stable materials, such as doublewrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.» Sterilize temperature: 70 F (13 C)» Sterilize time: 4 minutes» Dry time: 0 minutes Liquid Cycle: This cycle is used for sterilizing liquids in borosilicate containers with vented closures.» Sterilize temperature: 50 F (11 C)» Factory programmed sterilize time: 45 minutes» Dry time: not applicable Important: It is inappropriate for a healthcare facility to sterilize liquids for direct contact with patients. 75 F (135 C) Prevacuum Cycle: This cycle is used for efficient, high-volume processing of heat- and moisturestable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization.» Sterilize temperature: 75 F (135 C)» Sterilize time: 3 minutes» Dry time: 16 minutes TESTING CYCLES Vacuum Leak Test: This cycle is used for testing the vacuum integrity of the sterilizer piping. Sterilizer chamber must be empty while running this test cycle. Preprogrammed cycle parameters cannot be adjusted by the user. Dart (Bowie-Dick) Test Cycle: This cycle is used to conduct a Bowie-Dick test on the sterilizer. Recommended load is a STERIS Dart pack, or a properly prepared Bowie- Dick test pack. Preprogrammed cycle parameters cannot be adjusted by the user.» Sterilize temperature: 70 F (13 C)» Sterilize time: 3.5 minutes» Dry time: 1 minute CONTROL SYSTEM Design Features Century Control System monitors and controls all sterilizer operations and functions. The control system is factoryprogrammed with standard sterilizing cycles. All operatoraccessible control functions can be changed using the touch screen control. Important: If factory-programmed cycle values are changed, it is the responsibility of the healthcare facility to validate the efficacy of the changed cycle. Cycle values and operating features may be adjusted and verified prior to cycle operation. Cycle parameters are retained in the control memory for repeated use. Once the cycle is started, cycles and cycle values cannot be changed until the cycle is complete. If the chamber Prevac Configuration Sterilizer TEMP... 000 F 1 PRESS... 00 PSIG STATUS... DOOR OPEN 1 3 4 PREVAC PREVAC GRAVITY LIQUID 70 F 70 F 50 F 50 F S= 4:00 S= 4:00 S= 30:00 S= 45:00 D= 5:00 D= 0:00 D= 15:00 D= 00:0 00:00 AM 00-00-00 PAPER MENU MORE FEED CYCLES STANDBY SFPP Configuration Sterilizer TEMP... 000 F 1 PRESS... 00 PSIG STATUS... DOOR OPEN 1 3 4 WRAP/SFPP SFPP PREVAC GRAVITY 70 F 70 F 70 F 50 F S= 4:00 S= 4:00 S= 4:00 S= 30:00 D= 0:00 D= 0:00 D= 0:00 D= 15:00 00:00 AM 00-00-00 PAPER MORE FEED MENU CYCLES STANDBY Touch Screen Displays temperature drops below the set point during the exposure phase, the timer is set to stop and automatically reset once normal operating temperature is reached. Critical control system components are housed within a sealed compartment to protect the components from moisture and heat generated during the sterilization process. A cooling fan with filter is installed in the housing compartment to maintain positive pressure within the compartment, keeping components cool and dust-free. Operator interface control panel, consisting of a touch screen and impact printer, is located on the operating (i.e., load or non-sterile) end of the sterilizer. If the sterilizer is equipped with double doors, an additional touch screen is provided on the sterilizer's non-operating (i.e., unload or sterile) end. Touch-Sensitive Screen features a 30-line x 40-character graphics display. All sterilizer functions, including cycle initiation and cycle configuration, are operated by pressing the touch-sensitive areas on the display, referred to as "touch pads." Display indicates appropriate control buttons, operator prompts and status messages necessary to assist in sterilizer operation. All displayed messages are complete phrases, with no codes to be cross-referenced. Display also indicates any abnormal conditions that may exist either in or out of a cycle. Ink-On-Paper Impact Printer, located above touch screen, provides an easy-to-read printed record of all pertinent cycle data on -1/4" wide paper. Data is automatically printed at the beginning and end of each cycle and at transition points during the cycle. Printer take-up spool stores an entire roll of paper, providing cycle records which can be saved for future reference. Three paper tape rolls and two printer ribbons are furnished with each unit. 3

Non-Operating End (NOE) Control Panel, equipped on double-door sterilizers only, includes a touch-sensitive screen similar to the operating end screen. Preprogrammed cycles can be started from the NOE control panel. Display concurrently shows the same information as the operating end screen display. Cycle Configuration is performed by accessing the change values menu through the operating end touch screen. In addition to adjustment of cycle values, the following operating parameters can also be changed through the change values menu: Time Display and Printout Units AM/PM or 4-hour notation. Access Code requires entry of a four-digit access code to operate the sterilizer and/or change the cycle values. Operating the sterilizer or accessing the Change Values menu causes the display to request the entry of an access code. If the access code is not properly entered, the display returns to the standby or main menu screen, denying user access to the sterilizer or programming. Audible Signals are adjustable. Touch pad and end-ofcycle signals can be adjusted to one of four sound levels (off, low, medium or high) as required for the operating environment. The alarm signal can be adjusted to low, medium or high (it cannot be turned off). Print Format allows selection of either a full or condensed printout of the cycle information during processing. Temperature Display and Printout Unit are in Fahrenheit ( F) or Celsius ( C). Temperature is set, displayed, controlled and printed to the nearest 1. Recalibration is not required when changing temperature units. Pressure/Vacuum Display and Printout Units in psig/in Hg or bar. Recalibration is not required when changing pressure units. Technical Data The control system consists of microcomputer control boards and peripheral function circuit boards located within the control PC board housing. Internal battery backs up all cycle memory for up to 10 years. If a power failure occurs during a cycle, the battery backup system assures that cycle memory will be retained and proper cycle completion will occur once power is restored. When power is lost, the cycle is held in phase until power is restored. Once power returns, the event is recorded on the printout, and the cycle automatically resumes or restarts, depending on what phase the cycle was in at the time of power loss. The operator can manually abort the cycle, if necessary. SAFETY FEATURES Control lockout switch, equipped on the chamber door, senses when the door seal is energized and tight against the door. The control prevents the cycle from starting until the limit switch signal is received. If the control loses the appropriate signal during the cycle, the alarm activates, the cycle aborts, and the chamber safely vents with a controlled exhaust. Chamber float switch activates the alarm, aborts the cycle, and safely vents the chamber with a controlled exhaust if excessive condensate is detected in the vessel chamber. Pressure relief valve limits the amount of pressure buildup so that the rated pressure in the vessel is not exceeded. Power door safety feature causes the door drive to slip if the sliding door encounters an obstruction during movement. CONSTRUCTION Shell Assembly Two fabricated Type 316L stainless-steel shells, welded one within the other, form the sterilizer vessel. Type 316L stainlesssteel end frame(s) is welded to the door end. On single door units, the back of the chamber is fitted with a welded 316L stainless-steel dished head. Sterilizer vessel is ASME rated at 45 psig (3.1 bar) and insulated. The vessel includes one 1"-NPT chamber port for Customer use. Steam-supply opening inside the chamber is shielded by a stainless-steel baffle. Chamber Door(s) Door is constructed of Type 316L stainless steel. During cycle operation, the door is sealed by a steam-activated door seal. Door seal is constructed of a special long-life rubber compound. When the sterilize cycle is complete, the seal retracts (under vacuum) into a machined groove in the sterilizer end frame. A long-life proximity switch is used by the control to determine if the door is closed, or locking plates are engaged. An additional seal pressure switch prevents inadvertent cycle initiation if the door is not sealed. The door assembly is equipped with a mechanical locking mechanism that assures the door cannot be opened as long as the seal is intact and energized, and more than psi (0.14 bar) pressure is in the chamber. The sterilizer door is fitted with a stainless-steel panel that insulates the operator from the chamber end frame, reducing the chance of accidental contact with a hot metal surface. Chamber Drain System Drain system is designed to prevent sterilizer effluent from entering the water-supply system and sterilizer. The automatic condensing system, consisting of a stainless-steel plate-type condenser, converts chamber steam to condensate, and disposes condensate to waste. Cooling water flow is regulated by the waste line RTD to minimize water usage. Water supply shut off valve is located in the recessed area of the unit. Vacuum System Vacuum pump reduces chamber pressure during prevacuum and post-drying phases. Air is drawn from the chamber through the vacuum system. Following the dry phase, the chamber vacuum is relieved to atmospheric pressure by admitting air through a bacteria-retentive filter. Steam Source Sterilizers are piped, valved and trapped to receive buildingsupplied steam delivered at 50 to 80 psig (3.5 to 5.6 bar) dynamic. Steam piping is constructed of brass and includes a shut-off valve, steam strainer, and a pressure regulator. Piping All piping connections terminate within the confines of the sterilizer and are accessible from front and left side of sterilizer. Solenoid Valves with DIN connectors simplify sterilizer piping, and can be serviced individually. Manual Shut-off Valves are pressure rated at 15 psig (8.6 bar) for saturated steam. Valve handles are low-heat conducting. 4

MOUNTING ARRANGEMENT Sterilizers are arranged for either freestanding or recessed installation, as specified. Each sterilizer is height-adjustable. Sterilizer subframe is equipped with a synthetic rubber gasket to provide a tight fit between the cabinet panels on freestanding units, or between the front cabinet panel and wall partition on recessed units. On freestanding units, stainless-steel side panels and a louvered top panel enclose the sterilizer body and piping. ACCESSORY Seismic Tie-Down Kit conforms to Title 4 California Code of Regulations, 001 Amendment Section 163(A). Material Handling Accessories include stainless-steel chamber tracks and stainless-steel loading cars with paintedsteel carriages. Stainless-steel chamber rack and shelf are available for 36" (910 sterilizers. See tech data SD555 for details. PREVENTIVE MAINTENANCE A global network of skilled service specialists can provide periodic inspections and adjustments to help ensure low-cost peak performance. STERIS representatives can provide information regarding annual maintenance agreements. NOTES 1. The sterilizer is not supplied with a vacuum breaker or backflow prevention device and, where required by local codes, installation of such a device in the water line is the responsibility of the Customer.. Pipe sizes shown indicate terminal outlets only. Building service lines, provided by third parties, must supply the specified pressures and flow rates. 3. Disconnect switches (with OFF position lockout only; by third parties) should be installed in electric supply lines near the equipment. 4. Access to the recessing area from the control end of the sterilizer is recommended. 5. Clearances shown are minimal for installing and servicing the equipment. 6. Depending on the loading equipment used, additional clearance is required: If shelves are used, clearance should be length of the sterilizer plus 4" (610 at each door. If loading car and carriage will be used, clearance should be twice the length of the sterilizer at each door. 7. Floor drain should be provided within confines of the sterilizer framework. 8. Units require a minimum 38" (966 door opening for transport within facility prior to installation. UTILITY REQUIREMENTS Steam 1" NPT, 50 to 80 psig (3.5 to 5.6 bar) dynamic, 97% to 100% vapor quality. Drain " ODT drain terminal. (Floor drain capacity must handle peak water consumption; refer to Engineering Data.) Electrical Controls 10 Volt, 50/60 Hz, 1-phase,.0 Amp. Electrical Vacuum Pump 08/40 Volt, 50/60 Hz, 3-phase, 6 Amp per phase. 480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase. Sterilizer Feed Water 1" NPT, 0 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling. Refer to Water Quality Recommendations listed on page 7. NOTE: Back-flow prevention is by third parties; not supplied on unit. Telecommunications Requirements for ProConnect Response Center An active wired or wireless TCP/IP network, 10/100BaseT Ethernet connection at each piece of connected equipment, Internet access and an IP address on the facility network. 5 GB of available hard drive space to run the service agent. Can be installed on:» Dedicated PC running Windows XP with.8ghz processor, 51MB of RAM» Virtual Machine»Server Local STERIS login at the PC with a username of STERIS and the password should be ProConnect (STERIS Customer Number). Ethernet cable to connect each piece of STERIS equipment and the dedicated PC to the facility network. CUSTOMER IS RESPONSIBLE FOR COMPLIANCE WITH APPLICABLE LOCAL AND NATIONAL CODES AND REGULATIONS. The base language of this document is ENGLISH. Any translations must be made from the base language document. 5

ON OFF Reference the following equipment drawing for installation details. Equip. Dwg. No. Equipment Drawing Title 65435-775 6 x 37.5 Amsco Century Ster. Prevac OR SFPP Single (Hinge) Door Recessed Steam Heat 65435-776 6 x 37.5 Amsco Century Ster. Prevac OR SFPP Single (Hinge) Door Cabinet Steam Heat Single Hinged-Door, Cabinet Enclosed Single Hinged-Door, Recessed, One Wall 53.5" (1359 47" 1 (1194 44" (1118 47" 1 (1194 38" 3 (965 5mm 44" (1118 B 30" (76 4-1/" (114 Dimensions are typical drawing is not to scale. A 30" (76 (10-03 Wall Thickness 75.5", 74.5" 3, (188686 75.5", 1 Service Clearance - new construction only. Unit may be installed into existing Amsco brand 4" x 36" sterilizer space (Medallion, Eagle 000, Eagle 3000) without facility modification. Door Swing (left hand swing shown) 3 Wall Opening ENGINEERING DATA Drain: Electric: Steam: Water a : Operating Weight b : " ODT drain terminal (floor drain capacity must handle peak water consumption.) Control: 10 volt, single phase, 50/60 Hz, A Vacuum Pump: 08/40, 3 phase, 50/60 Hz, 6 A per phase, or 480 volt, 3 phase, 50/60 Hz, 3 A per phase Pressure: 50 to 80 psig (3.45 to 5.5 bar), dynamic, condensate free, and 97% to 100% vapor quality Consumption: 6 x 37.5 x 36" (660 x 950 x 910-11 lbs/hr (51 kg/hour) Peak Flow 190 lbs/hr (86 kg/hour) 6 x 37.5 x 48" (660 x 950 x 10-148 lbs/hr (67 kg/hour) Peak Flow 55 lbs/hr (116 kg/hour) 6 x 37.5 x 60" (660 x 950 x 150-185 lbs/hr (84 kg/hour) Peak Flow 335 lbs/hr (15 kg/hour) Size: 1" NPT Pressure: 0 to 50 psig (1.38 to 3.45 bar), dynamic Consumption: 130 gal/hr (495 L/hour) Peak Flow: 15 gal/min (57 L/min) Size: 1" NPT 6 x 37.5 x 36" (660 x 950 x 910 3800 lb (170 kg) 6 x 37.5 x 48" (660 x 950 x 10 400 lb (1900 kg) 6 x 37.5 x 60" (660 x 950 x 150 4700 lb (15 kg) a. Water consumption data is based on running one fully loaded Prevac cycle per hour and the machine idling for the remainder of the hour. b. Operating weight includes a full load in the chamber. 6

Reference the following equipment drawing for installation details. Equip. Dwg. No. Equipment Drawing Title 65435-777 6 x 37.5 Amsco Century Ster. Prevac OR SFPP Double (Hinge) Door Recessed One Wall Steam Heat 65435-778 6 x 37.5 Amsco Century Ster. Prevac OR SFPP Double (Hinge) Door Recessed Two Walls Steam Heat Double Hinged-Door, Recessed, One Wall Double Hinged-Door, Recessed, Two Walls 47" 1 (1194 38" 3 53.5" (1359 44" (1118 47" 1 (1194 38" 3 44" (1118 C 30" (76 (10-03 Wall Thickness Dimensions are typical drawing is not to scale. C 30" (76 (10-03 Wall Thickness 74.5" 3 (188686 74.5" 3 (1886 86 75.5" 1 Service Clearance - new construction only. Unit may be installed into existing Amsco brand 4" x 36" sterilizer space (Medallion, Eagle 000, Eagle 3000) without facility modification. Door Swing (left hand swing shown) 3 Wall Opening OVERALL INSTALLED LENGTH Refer to Illustrations WATER QUALITY RECOMMENDATIONS Condition Nominal Conditions Maximum Conditions 36" Chamber Length 48" (119 60" (154 Temperature 40-60 F (4-16 C) 70 F (1 C) Total Hardness as CaCO a 3 50-10 mg/l 171 mg/l Total Dissolved Solids 100-00 mg/l 500 mg/l A 69" (1753 B 58" (1473 81" (057 (1778 93" (36 8" (08 Total Alkalinity as CaCO 3 70-10 mg/l 180 mg/l ph 6.8-7.5 6.5-8.5 C 48: (119 60" (154 7" (189 Total Silica 0.1-1.0 mg/l.5 mg/l a. 17.1 mg/l = 1.0 grain hardness D 59" (1499 E 71-1/" (1816 71" (1803 83-1/" (11 83" (108 95-1/" (45 F 53-1/4" (135 6-1/4" (1657 77-1/4" (176 7

POWER ON OFF ON OFF ON OFF POWER Equip. Dwg. No. Reference the following equipment drawings for installation details. Cabinet Enclosed Equipment Drawing Title 65435-779 6 x 37.5 Amsco Century Ster. Prevac OR SFPP Single (Sliding) Door Cabinet Steam Heat 65435-780 6 x 37.5 Amsco Century Ster. Prevac OR SFPP Single (Sliding) Door Recessed Steam Heat 65435-781 6 x 37.5 Amsco Century Ster. Prevac OR SFPP Double (Sliding) Door Recessed One Wall Steam Heat 65435-783 6 x 37.5 Amsco Century Ster. Prevac OR SFPP Double (Sliding) Door Recessed Two Walls Steam Heat Single Horizontal-Sliding Door Recessed 5" 1 (131 (1778 5" 1 (131 68" (1778 (177 D Dimensions are typical drawing is not to scale. E (10-03 0 Wall l Thickness 75.5" 74.5" (1886 75.5" (1911 1 Service Clearance Wall Opening Recessed, essed, ed, One ewall Double Horizontal-Sliding Door Recessed, Two Walls 5" 1 (131 (1778 68" (177 38" 5" 1 (131 68" (1778 (177 F F (10-03 Wall Thickness 75.5" 74.5" (1886 74.5" (1886 75.5" For further information, contact: STERIS Corporation 5960 Heisley Road Mentor, OH 44060-1834 USA 440-354-600 800-548-4873 www.steris.com SD74 010, STERIS Corporation. All rights reserved. (11/01/10) This document is intended for the exclusive use of STERIS Customers, including architects or designers. Reproduction in whole or in part by any party other than a Customer is prohibited.