INTELLIMIST HUMIDIFIER

Similar documents
INTELLIMIST Residential Atomizing Humidifier and Control

Installation Instructions

Humidity Module OWNER S MANUAL. Complete Control from

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

Thermostat Remote Control & Receiver

Programmable 5-2 Day Digital Thermostat

OWNER'S MANUAL T0140. Contents Page #

Non-Programmable Digital Thermostat

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

2 - Wire Programmable Digital Thermostat

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Programmable 5-2 Day Digital Thermostat

5+2 Day. up to HEAT COOL

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Programmable Digital Thermostat

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

7-Day. Digital Thermostat. residential. & 2-cool

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

INSTRUCTIONS! DO NOT DISCARD!

Residential Duct Mount Builder s Box Media Air Cleaner

1 For All Programmable Digital Thermostat

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEU22P7S RESIDENTIAL. Model HVAC SERVICE PARTS

FLOW-THROUGH FURNACE HUMIDIFIER

Installation Instructions

5+2 DAY INSTALLATION. Digital Thermostat. residential. & 1-cool. up to. 1-heat PROGRAMMABLE HEAT COOL HEAT PUMP THERMOSTAT. Venstar Inc.

INSTALLATION, OPERATION AND MAINTENANCE

READ AND SAVE THESE INSTRUCTIONS

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Installation, Start -Up, and Operating Instructions

Performance Non-Programmable Owner s Manual

user s information manual

Legacy Non-Programmable Owner s Manual

User s Information Manual

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

INSTRUCTIONS! DO NOT DISCARD!

Model 1730A Compact Dehumidifier Installation Instructions

DS 2001 REVISED Humidifier Assembly and Instruction Manual

Installation Instructions

INSTRUCTIONS! DO NOT DISCARD!

MULTI HEAT PUMP PANEL CASSETTE TYPE DUCTLESS INVERTER INDOOR UNIT OWNER'S MANUAL. Models: CH12CC230VI CH18CC230VI CH24CC230VI

Duct Mount Rotating Drum Humidifier

HEAT HEAT HEAT COOL COOL

FLOW-THROUGH FURNACE HUMIDIFIER

Programmable Digital Thermostat

S1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

CUSTOMER SERVICE. Toll-free:

INSTRUCTIONS! DO NOT DISCARD!

Duct Mounted Atomizing Humidifier. Table of Contents

HE360 Humidifier Installation Kit

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

MD6-ES24VK. Installation, Operation, and Maintenance Manual

Duct Mount Atomizing Humidifier

Installation Instructions HEAT COOL FAN POWER

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

G-100ES Duct Mount Humidifier

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

Performance Non-Programmable Owner's Manual

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

Premier 2-Zone Controller model Installer Guide

1000 SERIES FLOW THROUGH POWER HUMIDIFIER 12-1/8 14-1/8

Steam Humidifier Fan Pack Installation & Maintenance Instructions

Installation Instructions Owner s Manual

Operator: Save these instructions for future use!

harborbreezeoutlet.com

Installation Instructions

7-Day. Digital Thermostat. residential. & 2-cool

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

Instant Hot Water Dispenser Owner s Manual

INSTALLATION INSTRUCTIONS Apartment Fan Coil

ICM 275. Replacement Description

G-100ES Duct Mount Humidifier

Owner s Manual. Digital Thermostat. Non-Programmable

Safety, Installation, and Operation Manual

Rainsoft Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois or

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

USER S INFORMATION MANUAL

2-Stage Under Counter Filtration System Model: WP-2 LCV

HE220, HE260 Humidifier Installation Kit

HE120, HE160 Humidifier Installation Kit

e Heater/Exhaust Fan/Light User s Guide

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. MARCH 2011 version 7

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

e Bath Fan with Light User s Guide

Home and Building Control Home and Building Control Helping You Control Your World

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Owner s Manual. Digital Thermostat

Humidifiers Dealer Parts List

Transcription:

TM TM OWNE'S MANUAL P/N P110-300 INTELLIMIST HUMIDIFIE TOTALINE IntelliMist Humidifier 4Z95 MODEL P11 0-300 24vac 7.5w For esidential Use Only H2 Intellimist On INTELLIMIST MicroFine Spray MIOPULSE Technology Assures Maximum Efficiency Scale educing Filter Included Up to 24 Gallons Per Day of Additional Humidity For Use With 1-7 Ton HVA Systems Designed For Use Only With: P110-0009 Humidistat P474-3000 Humidistat P374-1600 INTELLISTAT USE ONLY WITH ENTAL AI ONDITIONING SYSTEMS. THE HUMIDIFIE MUST BE MOUNTED OVE THE EVAPOATO OIL O EVAPOATO OIL DAIN PAN. IF THEE IS NOT A DAIN PAN, ONE MUST BE INSTALLED. TOTALINE PATENTS PENDING eplacement omponents Division arrier orporation 3/01

TABLE OF ONTENTS ONTENTS & AESSOIES...2 MOUNTING LOATIONS...3 ASSEMBLY & INSTALLATION...4 WATE HADNESS...6 WATE FILTE...7 WIING DIAGAMS...8 TOUBLE SHOOTING GUIDE...11 OUTPUT HEK...16 Page 1

AUTION This Humidifier MUST be used with Totaline P110-0009, P474-3000 Humidistats or P374-1600 INTELLISTAT. Follow Installation Instructions for Humidifier carefully. UNIT MUST NOT BE INSTALLED WHEE FEEZING TEMPEATUES MAY OU. DO NOT INSTALL ON FUNAE JAKET, O WHEE UNIT AND ITS OMPONENTS MAY OME INTO ONTAT WITH HOT SUFAES. PAKAGE ONTENTS P110-300 INTELLIMIST Humidifier Assy. #0862 Tube Assy. #0759 INTELLIMIST In-Line Water Filter #0800 Water Filter Mounting Bracket #0152 Mounting Kit AVAILABLE INTELLIMIST AESSOIES P110-0009 Humidistat P474-3000 Humidistat P374-1600 INTELLISTAT (ombination Thermostat / Humidistat) P110-0008 eplacement Filter / Nozzle USE ONLY WITH ENTAL AI ONDITIONING SYSTEMS. THE HUMIDIFIE MUST BE MOUNTED OVE THE EVAPOATO OIL O EVAPOATO OIL DAIN PAN. IF THEE IS NOT A DAIN PAN, ONE MUST BE INSTALLED. Page 2

1 SELET MOUNTING LOATION 1. The humidifier should be installed on the supply plenum, preferably near the coil. Mounting near the evaporative coil, if applicable, will allow any excess moisture to exit the system via the condensation drain pan. 2. On vertical equipment allow clearance of the humidifier and related components such as the water filter and plastic water live, from the exhaust vent. 3. On vertical equipment, if the nozzle is spraying away from the coil, there should be a minimum of three feet from the nozzle to the top of the plenum. If this is not available, then point the nozzle of the humidifier directly into the evaporative coil. 4. Always install downstream of an electronic air cleaner. Drill or knock out a 1 hole & 4 mounting holes for the #6 screws on the mounting template. PLENUM AI FLOW HOIZONTAL EQUIPMENT DAIN PAN HUMIDIFIE EVAPOATO OIL FUNAE PLENUM VETIAL EVAPOATO N-OIL PLENUM HUMIDIFIE ALTENATE LOATION VETIAL EVAPOATO A-OIL HUMIDIFIE ALTENATE LOATION DAIN PANS FUNAE FUNAE Page 3

LISTED 4Z95 US INTELLIMIST ON INTELLIMIST HUMIDIFIE 2 ASSEMBLE THE HUMIDIFIE Slide the mounting nut over the tube assembly. MOUNTING NUT (fig. 1) Fig. 1 Insert the tube assembly into the humidifier valve. Secure by turning the nut clockwise until finger tight, then additional 1/4 turn. (fig. 2) TUBE ASSY Fig. 2 3 INSTALL THE HUMIDIFIE Be sure to use a cold water connection. Mount the humidifier to the sheet metal using the four #6 mounting screws supplied. (Page 3) TOTALINE INTELLIMIST HUMIDIFIE MODEL: P110-300 24 VA 7.5 WATTS UL H2 Fig. 3 The in-line water filter should be mounted below or to one side of the humidifier assembly in a vertical position as shown. (Fig. 3) Be sure the flow arrow on the filter is pointing to the humidifier. Page 4

4 WATE ONNETION un 1/4 tubing from the water supply to the in-line filter. The saddle valve and tubing is supplied for this purpose. SADDLE VALVE INSTALL The self piercing feature of the saddle valve is for copper pipe only. All other materials of pipe, drill a 1/8 hole in the pipe. Turn the handle clockwise to expose the piercing pin beyond the seal approximately 3/16. Place the body of the valve over the hole in the pipe so the pin fits in the hole. Tighten the bottom clamp evenly. Turn handle clockwise and close the valve. AUTION SAFETY NOTE USE OPPE TUBING WHEE INSTALLATIONS MAY AUSE DAMAGE IF A WATE LEAK OUS. Page 5

WATE HADNESS If water hardness is 15 grains/gal or under the filter & nozzle (P/N P110-0008) should be replaced once a year. If the water hardness is higher than 15, the filter & nozzle should be replaced every 3 months during the heating season. Orifice otary Pin Nozzle Water Filter If the humidifier is run with the fan in the non-heating season, then the filter/nozzle should be replaced every 6 months. Water hardness test kits are available at local home improvement centers. Page 6

WATE FILTE The water filter should be mounted using the supplied bracket. (Figure 4) Up to 3 gallons of water should be run through the filter from the supply until the water appears clear, not gray or cloudy, before connection to the humidifier. This may be done using a short piece of tubing on the output of the filter. onnect to the humidifier and check for leaks. SUPPLIED BAKET Fig. 4 The water filter supplied with the humdifier is specifically formulated for optimal operation. The filter design inhibits bacteria, odor, and calcium buildup. The filter should only be replaced with Totaline part # P110-0008. lear, Plastic ase 4) 5 Micron Filter Screens Polyphosphate KDF Activated harcoal In the rare instance white powder is noticed on the interior of the house, this is an indication the filter needs to be replaced. Page 7

5 WIING DIAGAMS When & are used from a nearby thermostat: P110-0009 Humidistat Thermostat 24vac HUM Humidifier H2 W1 Furnace If only 1 wire is available from the furnace to the humidistat, W1 may be obtained from the thermostat. P110-0009 Humidistat HUM Humidifier H2 Furnace W1 24vac Page 8

5 WIING DIAGAMS The & terminals on the IntelliMist Humidifier are not connected internally. They are provided for an easy tie-off point when using 1 multi-conductor cable from the Humidifier to the humidistat. In this case H2 would need a jumper to. P110-0009 Humidistat HUM Humidifier H2 Furnace W1 24vac When connected to the IntelliStat (P374-1600): P374-1600 Intellistat W3 G W1/O/B W2 Y1 Y2 H2 Humidifier W1/O/B W2 Y1 Y2 HUM Furnace G 24vac Page 9

5 6 WIING DIAGAMS When only 5 wires are available to the thermostat and humidistat, a P474-0410 Add-A-Wire may be used as shown. P110-0009 Humidistat HUM H2 Humidifier STAT UP Thermostat Y1 G W1 W1 Y1 G 24vac Furnace ADD A Wire Part A ADD A Wire Part B Open all supply water valves to permit water flow to the humidifier. heck for leaks. Set humidistat to highest demand, 99%. When the humidifier mist is on, the ed LED indicator, on the top of the housing, will be on. When connected to the INTELLIMIST control, the ed LED will be observed to go on and off with the MIOPULSE technology control. eset the humidistat to the recommended setting, ~35%. Page 10

IntelliMist Humidifier Troubleshooting Guide 1. Humidity eading Will Not Increase When humidity levels are in the teens it may take several weeks to notice an increase in humidity in your home. This is due to the fact that virtually all of the moisture has evaporated from the wood, drywall, carpets, draperies, and furniture. Until this moisture is replaced, materials will absorb moisture from the air, causing very little humidity rise in the rooms. 2. In-line Fitler Installation When installing the in-line water filter, it is important that enough water be flushed through the filter. Up to three gallons of water (or until the water flow is clear) should be run through the filter to prevent micro fine particles form clogging the sprayer nozzle. 3. Humidifier Water onnections The plastic fittings supplied with the humidifier should be finger tightened, plus 1/4 turn with pliers. Over tightening with pliers or a wrench will cause the fittings to crack and split, thus leaking water. The plastic fittings are OK to use on copper pipe. The brass compression fittings should be tightened with a wrench, and then re-checked for leaks. The brass nut should slide on the tube first, followed by the compression sleeve, and the brass tube end inserted last. Then the tube should be inserted into the humdifier valve base and tightened with pliers or a wrench. Page 11

4. Too much moisture in the duct The IntelliMist Humidifier must be used with either the Totaline Humidistat (P110-0009) or Intellistat (P374-1600). Any other controller will cause a continuous (non-pulsed) spray. heck setup step 1 (Humidistat) or step 9 (Intellistat) to make sure pulse is turned on - if pulse is set to off, the humidifier sprays constantly, producing too much water. Maker sure the controller is set to the correct tonnage to match the air handler, setup step 3 (Humidistat) or step 10 (Intellistat). Humidistat: make sure HUM wire from humidistat is connected to the W or W1 terminal on the furnace, but NOT to the G or fan terminal. Interlocking the humidistat with the fan will cause the humidifier to run during fan-only or cooling, which will result in excess water in the duct. To run the humidifier in fan-only, use the Intellistat. For more information, see Factors that Affect Humidity ontrol. 5. an t raise humidity enough Make sure the controller is set to the correct tonnage to match the air handler, setup step 3 (humidistat) or step 10 (Intellistat). With the Intellistat it is possible to bring on the fan and humidifier any time the humidity is below the setpoint. To enable this feature turn on setup step 11, which will help to increase humidity in the space. Humidity can also be increased by running the fan continuously (Fan On button) or by using the programmable fan feature of the Intellistat to bring the fan on at selected intervals. heck the position of humidifier spray nozzle to make sure good evaporation is occurring - on short plenums if the spray is hitting the end of the plenum, it is better to turn the spray toward the coil. Page 12

6. Humidifer won t spray heck the red LED on humidifier, which must be viewed straight on. When the light is on the humidifier is attempting to to spray. If there is no spray, check the nozzle for blockage - if blocked remove and rinse or replace the nozzle. If the light never comes on, the humidifier is not receiving a signal to spray, or has no power. heck the controller to make sure there is a humidity demand - on the humdistat three raindrops will appear when it is calling for the humidifier to spray, on the intellistat a small vertical bar will appear in the lower left corner of the screen. If the symbol appears, check the wiring or, if using the humidistat, see below. 7. aindrops appear on the humidistat but the humidifier won t spray. There may a compatibility problem with the furnace. Add a pilot relay with the coil connected to W and on the furnace and the contacts to HUM and on the humidistat. This will isolate the humidistat from the 24 VA and solve the problem. Humidistats manufactured after 5/00 have built in isolation. 8. What are the and terminals for on the Humidifier? These terminals are merely tie-off points provided for convenience. It is not necessary to connect them to anything. Page 13

9. Increasing Humidity in the Home: Factors that Affect Humidity For homes that are in very dry climates with humidity levels in the teens, it may take several days or up to a week to notice increases in humidity in the spaces. This is due to the fact that virtually all the moisture has evaporated from the wood, drywall, carpets, draperies, and furniture. Until this moisture is replaced materials will absorb moisture from the air, causing little or very little relative humidity rise in the rooms. As with any whole-house humidifier, the Humidifier can only increase the moisture in the house when the fan is running Therefore, in climates where little heating is required and the heating/fan system is therefore run very few hours per day, the fan must be run in the nonheating modes to increase the humidity in the rooms. This can be accomplished in one of three ways. 1. The Intellistat in setup step 11 can be set to ON, then the Intellistat will run the fan and humidifier any time the humidity is below the setpoint. 2. The fan in setup step 13 through 15 of the Intellistat can be programmed to run so many minutes per hour during certain hours of the day. The Humidifier will run any time the fan runs and the humidity is below the setpoint. 3. The fan can be run continuously with the fan ON button. The Humidifier will then run constantly on a call for humidity with the Intellistat. Page 14

10. Factors That Affect Humidity: Additional Notes Even though the IntelliMist Humidifier puts out more humidity than any other whole-house humidifier, up to 24 gallons per day, it may not be possible to increase the humidity to a high level especially if the outside humidity is fairly low. For instance, with an outdoor air temperature of 40 degrees and 20% relative humidity, when the air is heated up to 72 degrees, the resulting humidity in the house is 8%. The amount of humidity that can be added to the air is limited by the airflow in the ductwork and the temperature of the air. Hot air, which you have when the furnace is running, can hold 6 time as much moisture as the air can hold when only the fan is running. It is much easier to increase the humidity in the house with the furnace running versus when only the fan is running. Both applications are limited by the amount of moisture that can be put into the air going through the ductwork without the moisture actually condensing in the ductwork. Page 15

OUTPUT HEK To check that all the terminals are in proper working order at the factory arrier has created a test screen located in the calibration mode of the Humidistat. 1. Push the 'on/off' button and the 'down' arrow until all icons on the LD screen are visible. 2. Now push the 'on/off' button once more. 3. The screen you are currently seeing is our test mode to ensure proper wiring between the Humidistat and the Humidifier. Push the 'flow' button to energize the Intellimist Humidifier. Water droplets on the bottom left hand corner of the screen will appear and the red LED will energize. Push the 'flow' button once more to deenergize the Intellimist Humidifier. 4. The screen you are now seeing is our test mode to ensure proper wiring between the Humidistat and the Furnace board, if your furnace is currently energized the Humidistat will display an H in the upper right hand corner of your screen. If the furnace is not energized a dash will appear in the upper right hand corner of your screen. 5. Push the 'on/off' button to exit the test screen and enter into the normal operating screen. Page 16

Warranty One-Year Warranty - This AIE OPOATION (herein referred to as OMPANY ) product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty a new or remanufactured part at the OMPANY S sole option, to replace any defective part will be provided without charge for the part itself; POVIDED the defective part is returned to our distribution through a qualified servicing dealer. THIS WAANTY DOES NOT INLUDE LABO O OTHE OSTS incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer. THIS WAANTY APPLIES ONLY TO PODUTS IN THEI OIGINAL INSTALLATION LOATION AND BEOMES VOID UPON EINSTALLATION. LIMITATIONS OF WAANTIES ALL IMPLIED WAANTIES INLUDING IMPLIED WAANTIES OF FITNESS FO A PATIULA PUPOSE AND MEHANTABILITY) AE HEEBY LIMITED IN DUATION TO THE PEIOD FO WHIH THE LIMITED WAANTY IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WAANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPESSED WAANTIES MADE IN THIS WAANTY AE EXLUSIVE AND MAY NOT BE ALTEED, ENLAGED, O HANGED BY ANY DISTIBUTO, DEALE, O OTHE PESON WHATSOEVE. ALL WOK UNDE THE TEMS OF THIS WAANTY SHALL BE PEFOMED DUING NOMAL WOKING HOUS. ALL EPLAEMENT PATS, WHETHE NEW O EMANUFATUED, ASSUME AS THEI WAANTY PEIOD ONLY THE EMAINING TIME PEIOD OF THIS WAANTY. THE OMPANY WILL NOT BE ESPONSIBLE FO: 1. Normal maintenance as outlined in the installation and servicing instructions or owners manual including filter cleaning and/or replacement and lubrication. 2. Damage or repairs required as a consequence of faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation. 3. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the inadequacy or interruption of electrical service. 4. Damage as a result of floods, winds, fires, lighting, accidents, corrosive environments or other condition beyond the control of the Manufacturer. 5. Parts not supplied or designated by the Manufacturer, or damages resulting form their use. 6. Manufacturer products installed outside the continental U. S. A., Alaska, Hawaii, and anada. 7. Electricity or fuel costs or increases in electricity or fuel costs from any reason whatsoever including additional or unusual use of supplemental electric heat. 8. ANY SPEIAL INDIET O ONSEQUENTIAL POPETY O OMMEIAL DAMAGE OF ANY NATUE WHATSOEVE. Some states do not allow the exclusion of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. Page 17 P/N 88-231