UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Similar documents
MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

MicroRay IR-100 NEW. Inspection MicroRay IR-100

portable gas analyser

portable gas analyser

Pressure measuring instruments

FIRST CHOICE CATERING SPARES LTD DIGITAL TECHNOLOGY APRIL 2015 FS

Automatic Isokinetic Sampler ST5

EAGLE 2X: C155KIT EAGLE 3X: C157KIT

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Your competent partner for measuring and services.

Dräger X-am 7000 Multi-Gas Detection

Omniguard 4: Features

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

E instruments. General Catalog 2011 / Infrared Thermometers Calibrators Flue Gas Analysers. Global Smart Measurement Solutions

gas monitoring system

Specifications Minimum Typical Maximum Unit

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Operate the Mutli-Gas Monitor PID

E instruments. General Catalog Global Smart Measurement Solutions. Bulletin GEN - ed

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Combined boiler. for solid fuel and pellets

Committing to the future. Measurement Engineering for Heating and Installation

EasyLog Data Logger Series

VD8. mode VD8. Digital Compact Vacuum Meters Data Loggers

Committing to the future. Measurement Engineering for Heating and Installation

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

COA-2010-F Electronic CO 2

GAS ANALYSIS / DETECTION Gas Detector

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

EL-USB-1-LCD Temperature Data Logger with LCD

Measurement Solutions for Refrigeration Technology.

Eurotron Instruments 2008 News IEC17025 SIT Accredited Laboratory

TOOLS AND INSTRUMENTS

ALTAIR 5X Multigas Detector Product Specification

THERMAX Efficiency Monitor

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

EL-USB-1-LCD Temperature Data Logger with LCD

PATENTED PATENT PENDING PATENTED PATENTED

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Measurement Solutions for Refrigeration Technology.

EasyLog Data Logger Series

EL-USB-TC Thermocouple Data Logger with USB Interface

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

PROCESS ANALYSERS. SERVOFLEX MiniMP (5200) Gas Analyser. Operator Manual. Part Number: A Revision: 8 Language: UK English

CO warning instruments and gas spillage detectors

LOW NOx MODULATING GAS BURNERS

COMBUSTION, ENVIRONMENTAL ANALYZERS, INDOOR AIR QUALITY, LEAK DETECTION, AIR ACONDITIONED & REFRIGERATION, CARBON MONOXIDE AND COMBUSTION ANALYSIS

Infrared Moisture Balance (FD-800)

Wöhler DM Operating Manual Digital Manometer

SCAN200E USER S MANUAL

Complete Boiler Management in a Compact, Affordable System

Dräger X-am 7000 Multi-Gas Detection

Power Flame Incorporated

AS950 PORTABLE SAMPLERS

MGC Dock User s Manual

AS950 REFRIGERATED SAMPLERS

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

Nardalert S3 TM Non-Ionizing Radiation Monitor

GasAlertMicroClip X3 Specifications

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

VM-3000 Mercury Vapor Monitor

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Datalogging as standard

VM-3000 Mercury Vapor Monitor

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

F-900 Portable Ethylene Analyzer

Security Alarm Systems

Complete burner management in a compact, affordable system

MGC Dock User s Manual

EL-OEM-3 OEM Packaged Voltage Data Logger

GMH 285 / GMH 285-BNC

Complete Gas Analysis

Warranty Registration

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Dräger X-am 2500 Multi-Gas Detection

ppm F psi ΔP C "H 2 NO x Testo An overview

Dräger Polytron 7000 Fixed gas detector

continuous emissions monitoring Combustion & Environmental Monitoring

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Easyfire Standalone biomass pellet boiler

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Operations Manual TS400. Test Station for G450/G460 Gas Detector

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

Mercury Vapor Monitor VM-3000

EST User Manual. (Please read this manual carefully before using)

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

RS /E-EV C01 SERIES

intrinsically safe detector for hydrocarbon gases

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Industrial Grade Gas Detection

Transcription:

Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser >10h Operation with Li-Ion Battery Pack Smart Autozero without Removal the Probe CO Dilution up to 10% Stores up to 250 Complete Analysis with Customer Name and Address Graphic Display with Menu and Zoom Feature USB & RS232 interface with Window Software Made in Italy "Excellence in measurements" O 2 CO CO% CO 2 NO NO x H 2 T-Air ( ) T-Gas ( ) Combustion Efficiency (ETA) Excess air (Lambda) Pressure (Pa) CO/CO2 ratio Gas Leak Detector T+RH% Probe The most powerful and advanced palmtop analyser: up to 5 sensors! Heated Probe 5 INSTRUMENTS IN 1: Combustion Flue Gas Analyser NO/NOx Emissions Draft & Differential Pressure Meter 2 Channel Differential Thermometer Ambient CO Monitor (Room Test) Gas Network Leak Tightness Tester Gas Leak Detector Ionization Flame Tester Gas Sampling Hose Temperature & Humidity Meter Built-in Impact Printer (Not Thermal!) Water Trip Kit Advanced Combustion Flue Gas Analyser 세일국제무역 Tel. 02-837-6974 Fax. 02-859-2059 www.eurotron.co.kr UNIGAS 3000 PLUS 1 / 6

Instrument design Print Connection USB Cable Connection AC Power / Charging Adapter Connection T+RH(%) Probe Gas Leck / Natural Gas Probe LCD Display Gas Sampling Hose Pressure / flow measurement Water Trap Kit Line Filter Magnet case UNIGAS 3000 PLUS 2 / 6

One Instrument with Many Functions The provides the latest tecnology in flue gas analysis. One instrument with many features: up to 5 gas sensors; autozero valve for quick start-up CO sensor with automatic protection; built-in impact printer; water, air and surface temperature measurements; draft, gauge and differential pressure measurements; searching for presence and location of gas leaks; operator safety with ambient CO continuous monitoring; ambient temperature and relative humidity measurements. IRDA output for Pocket PC data transfer. Easy replaceable gas sensors uses extended life, low maintenance sensors replaceable by the user. CO sensor dilution An automatic device protect the CO sensor in presence of high CO level. The measuring range will increase up to 10% CO. Advanced Diagnostic Built-in flow meter with internal leak test. Diagnostic errors on sensor with current indication. Autozero valve for quick start-up You can install the probe in the stack immediately during the autozero. The instrument will be ready in less then 60 seconds. Standard Report of Calibration Each instrument is factory calibrated and certified against Eurotron Standard to ensure traceability, and shipped with a Report of Calibration. Keyboard & Display Text, menu, and keyboard available in most common languages (not icons) for simple and intuitive operations. Engineering units are selectable by keyboard. The large backlight graphic LCD can display 3, 6 or 12 values per page (ZOOM function) or with bargraph format. Li-Ion Rechargeable battery Lithium Ion rechargeable batteries provide longer field use free from memory effect and total discharge. Flue gas analyser and internal printer is powered by a unique battery pack. Charger is supplied as standard. Multi Fuel selection provides up to 5 fuels for calculating combustion values. Most used fuels for your country are preloaded from factory. Others fuels can be added using GasConfig PC software. Built-in impact printer The instrument has an optional internal and rugged printer. It uses a low cost common roll of paper. Certainly more readable, long time and heat resistant than the thermal printout on chemical paper. Smoke index Smoke index measurement is performed by using the optional external hand pump. The results can be stored in the internal memory and printed on the report. Ambient CO safety monitoring Room Test (BS7967) A procedure can be selected to monitor the CO in ambient air using the internal sensors. An internal program allows the CO max measurement in atmospheric boiler room test with 15 values logging. An external optional probe is also available for continuous surveillance of the ambient and operator safety. Both acoustic and visual alarm are available. Pressure/Draft input Differential pressure input to verify: low pressure, draft, gas pipework leak with pressure decay programme, pressure in gas pipework, pressure in combustion chamber, DP on filters and fan, pressure switches calibration. Gas sampling probe Flue gas sampling probes, with different lengths and shapes, are available to match each specific requirement. The sampling probe is connected to the instrument with a single or dual hose through a water trap and a suspended particle filter. Combustion air temperature probe A remote Pt100 probe is available for remote combustion air temperature measurement. This probe is strongly recommended mainly in forced air boiler to obtain an accurate efficiency measurement. UNIGAS 3000 PLUS 3 / 6

One Instrument with Many Functions Gas pipework leak test To check gas pipework for the presence of leaks using a pressure decay program and the internal pressure sensor. The tightness test procedure includes dual report (let by). IGE / UP / 1B compliant. Flash memory The flash memory allows the instrument to be configured by updating the UniGas firmware for any future legislation requirement or product performance upgrading Proprietary designed trap Built-in protection for water suction. External, to prevent risk of sensors damage. Big water tank capacity for high condensing boiler. Small rubber cup for easy water empty. Long life paper filter. Ionization flame tester Checks the ionization current in boiler flame control sensor. Gas leak sniffer The instrument can operate in two ways: An external probe is available to locate the position of a gas leak. This probe has a flexible stainless steel shaft to reach difficult locations. An internal optional sensor can be installed inside the analyser to locate the position of a gas leak into the domestic pipe network. The internal pump draws the air from ambient and makes the instrument more sensitive for micro-leaks. Gas sniffer probe Technical Specifications Type: palm-top combustion gas analyser. Print autonomy: up to 40 reports with full battery (typical). Calibration: automatic calibration procedure at instrument switch-on. Self-diagnosis: Sensors efficiency test with display diagnostic messages. Fuel types: Up to 10 selectable from keyboard (most common preprogrammed). Printed report header: 4 user programmable lines Display: graphic black LCD with white lamp. Flue gas probes: stainless steel shaft with incorporated temperature sensor. Memory: up to 250 full analysis data structured by boilers (Tags). Power supply: High capacity Ni-MH rechargeable battery pack / external battery charger. Charging time: 3h at 90% with instrument Off. Battery life: 10 hours (typical) continuous use (without printing & backlit). Printer: Internal impact type 24 columns with 58 mm paper roll. Printer power supply: from the analyser battery pack. Serial communication: standard USB serial interface. Operating temperature: from -40 C to +70 C Storage temperature: from -40 to +80 C (3 months maximum at temperatures exceeding the operational limits). Dimensions: 115x90x330 mm Weight: 900 g nett. (including battery and printer). UNIGAS 3000 PLUS 4 / 6

DBGas 2004 - Boiler Test & Customer Database Manager can store 250 readings structured by boilers and customers. Using the optional DBGas 2004 WindowsTM software package, you can organize and manage your inspection and maintenance activity. DBGas 2004 software package includes TM GasConfig Windows TM software. Using the software you can modify the configuration of the instrument. USB standard interface Pa Probe Water Trap External 200Pa probe for natural boiler draft measurements, UNI 10845 compliant Resolution: 0.1 Pa Precision: ±0.5 Pa (from-10 to +10 Pa); ± 3 Pa otherwise. Supplied with certificate of calibration. Accessories for Patent pending Rubber Cup to Empty Line Filter ABS rigid carrying case Compact rigid carrying case (TGD - Temperature, Gas, Draft) sampling probe 180mm, 300mm, 750mm, 1000mm, 1500mm Differential pressure probe and burner hose kit Manual pump for smoke index measurements Pt100 remote air sensor with cone Ambient T+RH% probe Ambient CO probe Gas sniffer probe Standard Gas Sampling Hose Wanted length various Heated Gas Sampling Probe Standard Gas Sampling Extension Hose Length 300mm, 750mm, (max. 100m) 1000mm, 1500 mm UNIGAS 3000 PLUS 5 / 6

Gas measured values Parameter Range Unit Accuracy Res. Principle O 2 0 25 % ±0.1% vol. 0.1 % Electrochemical CO 0...20,000 ppm ±1 ppm < 400 ppm 1 ppm Electrochemical ±0.2% rdg up to 4000 ppm CO (H 2 compensated) 0 10,000 ppm ±0.5% rdg elsewhere 1 ppm Electrochemical CO % 0...10 % ±0.5% rdg up to FS 0.01 % Electrochemical CO 2 0...100 % 0.1 % Calculated NO 0...4,000 ppm ±1 ppm <125 ppm 1 ppm Electrochemical ±0.2% rdg up to 3000 ppm NO x 0 5,000 ppm Calculated H 2 0...2,000 ppm ±0.2% rdg f.s 1 ppm Electrochemical Tgas - 40...1200 ±(0.2% + 0.3 ) 0.1 TC K T - 40...999 0.1 Calculated Tflow - 40...100 ±(0.2% + 0.3 ) 0.1 TC K Treturn - 40...100 ±(0.2% + 0.3 ) 0.1 TC K Pressure -200...200 mbar ±0.2 mbar <50 mbar 0.1 mbar Piezo ±0.1% rdg. >50 mbar Draft ±40.00 hpa ±0.01 hpa < 300 Pa 0.01 hpa Piezo ±0.1% rdg. > 300 Pa Excess air 1.00...infinity or 0-250% 0.01 Calculated Efficiency 1...120 % (also for condensing boilers 0.1 % Calculated with automatic detection) All emission measurements can be displayed with reference to a programmable O 2 value. Accuracy limits are stated as % of reading. An additional ±1 digit error has to be considered. The stated pressure relative accuracy is valid only after the zero procedure. 3 Measuring reading can be directly converted from C to F, ppm to mg/nm and from hpa to mmh 2 O, mbar, inh 2 O. UNIGAS 3000 PLUS 6 / 6