Thermal equalization is the obvious answer to the situation. But, how is "thermal equalization" achieved?

Similar documents
Farm Energy Audit Workshop

The Ed Roberts Campus Berkeley, CA

QUALITY. Task Force. Shifting from Corn Drying to Corn Storage. Dirk E. Maier, Agricultural Engineering. Average Temperature F

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Practical and Effective Approaches to Residential Ventilation for Production Builders

Better Buildings By Design 2013 Building the Renewable Energy Ready Home Solar Thermal Lessons Learned and Results

IES Whole-Building Energy Model Baseline Energy Model Input/ Output Report. East Liberty Presbyterian Church East Liberty Presbyterian Church

Lifestyle Electric Thermal Radiator

Lifestyle Electric Thermal Radiator

Identification of Aberrant Railroad Wayside WILD and THD Detectors: Using Industry-wide Railroad Data. June 10, 2014

Smart Grid Tables. Exploring the Electrical Infrastructure Grades 9-12

Cork County Energy Agency

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Storing excess daytime solar energy to heat greenhouse at night!

Energy Conservation Workshop. SPONSORED BY: Xcel Energy

GRAIN STORAGE AERATION PRESENTED BY: BRENT BLOEMENDAAL AERATION EXPERT

MEASURED PERFORMANCE DATA FOR

ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems

Dehumidification: Energy Efficiency Comparisons

USING INFRARED TECHNOLOGY TO DEFINE ENERGY SAVINGS OPPORTUNITIES. James L. Park Energy Conservation Specialist I-Star Energy Solutions

On Balance: Heat Rejection Control a Packaged Solution

Performance of Solar Water Heating Systems in the United States

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

Time-Based Scheduling of Residential Ventilation

Heat Pumps and Public Swimming Pools, a Perfect Match

DISTRICT HEATING SCHEME FEASIBILITY STUDY FRANKTON FLATS QUEENSTOWN

Owner s Manual MODEL 8555

Heritage Park Irrigation System Inspection Review of Water Use Estimated Water Budget Potential for Savings

Energy & Water Savings in Commercial Food Service

Heat Recovery Systems PTG, SWT Series.

FRANCE PARIS REGION OFFICES

Orange Solar Pump HD50

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Daikin Altherma Selection Report

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

Heat recovery systems. For hot air and hot water applications.

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

Efficient Irrigation, Smart Controllers and Climate Appropriate Shade Trees. Clovis Community College Center Clovis, CA

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

Grain Handling, Drying and Storage Management

Heat recovery. Heat recovery. Gas heating 280 up to 54,000 /year. Oil heating 284 up to 54,761 /year. Electrical power consumption

MODEL 9308 ENERGY MANAGEMENT COMPUTER OWNER'S MANUAL

Integrated Building Environmental Design Case Study: Beijing Parkview Green

announcements 4/10/08

Solar Hot Water Heating Systems

The Role of the Landscape Contractor to Conserve Water

Designing and Operating an Energy Efficient Foodservice Facility March 12, 2014 Winnipeg, MB

Gardening Beyond the Frost

Copyright 2003 IBACOS, Inc. All rights reserved.

COMPRESSORS. Heat recovery. For hot air and hot water applications.

Keep your electricity bill cool this summer

Energy efficient climate control in museum stores. Poul Klenz Larsen

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

Special Topics on Residential HVAC

Wal-Mart HE.5 Supercenter

ELECTRONIC THERMOSTAT

Energy Efficiency Programs in Action

Generation gap: How baby boomers and millennials stack up in their perceived and actual electricity use. Report. March 2019 BCH19-217

COST REDUCTION BY REPLACING STEAM WITH COKE OVEN GAS FOR HOT AIR DRYER UNIT IN THE ELECTROLYTE CLEANING LINE

Water Heater Innovations Marathon Water Heater Limited Warranty Policies & Procedures

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

WLAC Facilities Committee Meeting. September 18, 2017

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Cooling Options for Geothermal and Concentrating Solar Power Plants

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Heating and Hot Water

Auburn University Basketball Arena:

Everything you need to know about Radiant Heating but didn t dare ask

Comparison Blackberry Production Under High Tunnels and Field Conditions. High Tunnels

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

Living the (Solar) Dream Powering your lifestyle with the sun Ron Kube. Photo: Great Canadian Solar

Type 300 Series Electrode Stabilization Ovens

OWNERS MANUAL. PLEASE READ THIS MANUAL BEFORE OPERATION

OWNER S GUIDE ORIGINAL CLASSIC LINE

Choosing & Using the right Electric Heater

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate

Kimberly Rollins, Professor, Department of Economics, University of Nevada, Reno

Shifting Patterns of Water Demand: Socio-Demographic Challenges for Water Managers

IntelliFlo VS+SVRS. Intelligent Variable Speed Pump By Pentair Pool Products. The most valuable and responsible addition to any pool

BEST-IN-CLASS PERFORMANCE 2015 Q3 SAME-STORE

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Hot Water Generation for Commercial and Industrial Applications. Paul Marsden Specification Sales Manager

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

up to 98.7% efficiency can save over $800 a year** The SLP98V is a choice you can feel good about.

Greater temperature control

GUIDE WINTER TAKE CHARGE FARMERS EC 2019 EVERYTHING YOU NEED TO STAY WARM EFFICIENTLY WHILE AVOIDING HIGH WINTER BILLS. YOU RE IN POWER.

A. Product Data: Include rated capacities, furnished specialties and accessories.

Monthly Report for July 2015

Financial Results for First Quarter of Fiscal 2013, ending March 31, August 3, 2012

Refrigeration and Boil Off Compression Systems for NGL Export Facilities

ARTI Charcoal Solar Briquette Dryer Improvement Project Report

(12) United States Patent (10) Patent No.: US 6,692,130 B1

Performance of Berries in Field and High Tunnel Production System

TREATMENT AND CONDITIONING OF DISMANTLED MATERIAL AND OPERATION WASTE IN EWN OVERVIEW. Rohde, Mathias

AHE S -12 VDC AHE S - 24 VDC

Appendix A. Reference Evapotranspiration (ETo) Table.

2018 thesimple, Inc.

B&M European Value Retail SA Interim Results Presentation 26 weeks to 23 rd September 2017

Transcription:

OVERVIEW The Airius Thermal Equalizer product line is designed to create a more pleasant working/living environment and to reduce total energy consumption, which results in significant annual cost savings. DEFINING THE PROBLEM First it is important to understand and appreciate the natural phenomena of "temperature gradients." Temperature gradients, or levels, occur when there is minimal air movement within an enclosed building space. The hot air generated by a building's heating system steadily rises to the ceiling. The same holds true for the warm air created during the day by the sun striking a building's roof and southerly facing outer walls. Conversely, cold air sinks to the floor. The net effect is that the ambient temperature at ceiling level is substantially higher than the temperature at floor level. How great is this "substantial" differential? If the heating system's thermostat is set to maintain a comfortable environment at floor level, the temperature at ceiling level will typically be between 0.5 and 1.0 degrees Fahrenheit higher per foot of vertical elevation. What is the net effect? In a typical open manufacturing or warehouse space (assuming 20' to 50' ceiling heights) the temperature at ceiling level can easily reach over 100 degrees Fahrenheit while the temperature at floor level is barely at comfort level. Thermal equalization is the obvious answer to the situation. But, how is "thermal equalization" achieved? PRESENTING THE SOLUTION Airius Thermal Equalizers are specifically designed to efficiently and silently move large quantities of hot ceiling air in a downward direction to the floor. Each unit measures approximately 16" in height and is about 12" in diameter. The external shape is very similar to that of a modern jet engine. The big difference is that the "engine" is mounted so that the exhaust-end points downward. Inside each unit highly efficient fan blades interact with a patented uniquely designed multiple vane stator assembly. The net result is a column of air that smoothly flows in a downward direction up to a distance of 60 feet. A typical Airius System installation is comprised of a series of units working in concert to address the thermal equalization requirement of an enclosed open high-bay environment. After start-up (and in a relatively short period of time) an almost uniform temperature balance (floor to ceiling) is achieved throughout the installed space. Once "thermal equalization" is achieved, several very dramatic things begin to happen. The difference between ceiling and floor temperature readings is substantially reduced. Studies indicate that over time, this difference will stabilize to between 1 and 2 degrees Fahrenheit; thus, the comfort level of the environment is dramatically increased. There are no "cold or hot spots" at floor level, nor is it "hot upstairs and cold downstairs." Page 1 of 9

Over the short span of a few weeks, the previously wasted heat energy that was at ceiling level (and escaping through the roof) is increasingly transferred into the mass of the floor and onward into the ground beneath it. A gigantic multi-thousand ton "heat battery" is created. Just as it is possible to have "perma-frost" soil, it is also possible to create "perma-warm" soil. The result is that the total "thermal mass" of a building (including its furnishings, machinery and contents) stabilizes to the same temperature. In a very short period of time there is a dramatic decrease in heating system utilization. In recent experiments, the outside air temperature at night was in the mid-twenties; the heaters rarely turned on. Energy utilization dropped by over 50%. A three to four day snowstorm or weeklong cold snap is no match for thousands of tons of building mass and months of stored thermal energy. It is also important to remember that the sun produces significant heat energy during the winter months (just put your hand on a black car, even on a cloudy day). When it is bitter cold outside, radiant heat energy is still being generated during daylight hours. WHAT ABOUT COOLING? Thermal gradients can also cause discomfort and excessive energy utilization problems during the summer months. Typically floor level areas near cooling outlets are very cool indeed, while the rest of the occupied zone may be overly warm. In many cases, the total internal volume of a building must be overcooled in an attempt to maintain reasonably cool temperatures in non-directly cooled areas. The net result is increased energy consumption and cost. The benefit of thermal equalization is a consistent and uniform temperature gradient, which in turn results in the elimination of areas that are overcooled in order to maintain an acceptable temperature in other areas. This does not mean the elimination of cooling costs but, instead, the elimination of "overcooling" costs. So even during the hot summer months, Airius Thermal Equalizers reduce energy consumption and pass the cost savings on to you. HOW DOES THE AIRIUS THERMAL EQUALIZER WORK? As previously described, each AiriusThermal Equalizer is basically an extremely efficient air turbine that is suspended just below ceiling height. Each unit takes in resident hot ceiling air and silently transports it to the floor in the form of an almost imperceptible air column. Unlike a ceiling fan, the air is highly directed in a downward direction and not simply swirled around. Each unit is capable of "equalizing" somewhere between 1,000 and 1,500 square feet of open floor area; roughly a 40 foot diameter circle. The direct financial benefits of an Airius System installation are profound: Recent tests have conclusively demonstrated that an 18,000 square foot manufacturing facility in Colorado has reduced its annual heating bill of $24,000 by half. That's $12,000 per year of reduced operating expense, or put another way, potential increased profit. An Airius System will pay for itself (equipment and installation costs) within one to three years. The major influencing factors are ceiling height, building configuration and geographical location. Airius Systems are inexpensive to install and operate. Each individual unit consumes about the same energy as a 35-watt light bulb. Page 2 of 9

The costs associated with system maintenance are minimal. The suspended electrical conduit installation system allows for a simple swap-out of units for annual or periodic cleaning. Cleaning and maintenance frequency will naturally be a factor of the environment. In many environments once thermal equalization and mass stabilization are achieved, there will be no need to run the Airius System 24 hours a day. The Airius System effectively becomes a building s low-cost supplemental heating system. Basically, all the Airius System has to do is maintain a constant thermal mass temperature. In addition to the cost savings achieved through reduced energy utilization, there is also the benefit of reduced wear and tear on the originally installed heating and cooling systems. This is a significant consideration. In certain situations, there is also the benefit of reduced spoilage or damage to temperaturesensitive products due to temperature variations and/or extreme heat concentrations at elevated storage levels. In other specialized building applications such as pools, gymnasiums and indoor tennis courts, there is significantly reduced indoor moisture condensation a comfort, health and facility maintenance benefit. In temperature sensitive manufacturing or process environments such as high quality offset printing, thermal equalization and stabilization creates a constant and dependable temperature environment. Precision machining tolerances, manufacturing and/or production process tolerances are more easily maintained. A significant factor to remember is that the Airius Thermal Equalization System results in a vastly improved level of comfort for staff, visitors and customers. The Airius Thermal Equalization System represents a technological breakthrough in high-bay building energy utilization. Rather than wasting a free and clean natural resource, i.e. the sun's daily radiant heat energy, the Airius System silently and effectively utilizes that thermal energy, and passes the net savings on in the form of a direct operational cost reduction. In addition, the system's ability to eliminate the thermal gradient phenomena inherent in any large open space environment reduces the costs associated with overcooling during summer months. IN SUMMARY Airius Thermal Equalizers are easy to install, quickly pay for themselves, and ultimately reduce heating/cooling related operating costs by up to 50%. Your facility could benefit by installing an Airius Thermal Equalizer today. Page 3 of 9

AIRIUS PRODUCT SPECIFICATIONS Free Hanging Ceiling Models MODEL HT. in IN. DIAM. in IN. WT. in LBS. WATTS VOLTS COVERAGE in SQ. FT. CEILING HEIGHT Model 300 SF 9 6 5 18-35 110 300 Up to 20 ft. Model 15 16 12 10 23 110 1,000 1,500 Up to 15 ft. Model 25 16 12 10 35 110 1,000 1,500 Up to 25 ft. Model 40 16 12 10 75 110 900 1,200 Up to 40 ft. Model 100 Cascade Varies 12 35 50 110 110 800 1000 Over 60 Ft. Electric Turbine Fan Each Airius Thermal Equalizer model has a specially designed electric turbine fan and blade design to meet the specified air movement and building requirements for that model. Air Flow Created by Airius Products Free Hanging Ceiling Model Page 4 of 9

ABOUT THE AIRIUS THERMAL EQUALIZER Free Hanging Ceiling Models The Airius Thermal Equalizer is designed to equalize the layers of hot and cold air in buildings and facilities with high ceilings. This state-of-the-art energy saving product is designed to create a more pleasant working/living environment and to reduce total energy consumption, which results in significant annual cost savings. The Airius Thermal Equalizer is an extremely efficient air turbine that is suspended just below ceiling height. Each unit takes in resident hot ceiling air and silently transports it to the floor in the form of an almost imperceptible air column. Unlike a ceiling fan, the air is highly directed in a downward direction and not simply swirled around. Each unit is capable of equalizing somewhere between 1,000 and 1,500 square feet of open floor area; roughly a 40 foot diameter circle. PRODUCT OPTIONS Free Hanging Ceiling Models Flexible Duct Applications: High ceiling applications in excess of 40 feet Buildings with cross airflow currents that interrupt downward column of warm air Floor level discharge of warm air Remote Fan Speed Control Color Options Standard Off white and dark gray Special color requests will be quoted INSTALLATION OPTIONS Free Hanging Ceiling Models The Airius Thermal Equalizers can be configured to any building requirements. A number of installation options are offered. Extension cord to receptacle box Direct to conduit Direct to junction box WARRANTY All Airius Models There is a full warranty for one year from date of purchase on parts and workmanship. If defective while under warranty, a new unit will be sent at no charge, in exchange for the defective unit to be returned UPS collect. REFURBISH PROGRAM All Airius Models Avedon Development, LLC offers a refurbish program on all Airius Thermal Equalizers that are no longer under the one-year warranty. Any Airius Thermal Equalizer that is no longer under warranty can be returned to Avedon Development, LLC and will be refurbished, or replaced, for one half the current price of the Airius Thermal Equalizer Model. The Refurbish Program does not cover units that are damaged beyond the normal expected usage of the product. BUSINESS PARTNER Avedon Development is a proud partner of Rebuild America, a network of partnerships that foster energy efficiency and renewable energy in commercial, government and public housing buildings. For more information about Rebuild America, visit www.rebuild.org. Page 5 of 9

AIRIUS PRODUCT SPECIFICATIONS Suspended Ceiling Models MODEL HT. in IN. SIZE in IN. WT. in LBS. WATTS VOLTS COVERAGE in SQ. FT. CEILING HEIGHT Model 15 SC Suspended Ceiling Model 25 SC Suspended Ceiling Model 40 SC Suspended Ceiling 15 24 x 24 20 23 110 1,000 1,500 Up to 15 ft. 15 24 x 24 20 35 110 1,000 1,500 Up to 25 ft. 15 24 x 24 20 75 110 900 1200 Up to 40 ft. Electric Turbine Fan Each Airius Thermal Equalizer model has a specially designed electric turbine fan and blade design to meet the specified air movement and building requirements for that model. Air Flow Created by Airius Products Suspended Ceiling Model Page 6 of 9

ABOUT THE AIRIUS THERMAL EQUALIZER Suspended Ceiling Models The Airius Thermal Equalizer is designed to equalize the layers of hot and cold air in buildings and facilities with high ceilings. This state-of-the-art energy saving product is designed to create a more pleasant working/living environment and to reduce total energy consumption, which results in significant annual cost savings. The Airius Thermal Equalizer is an extremely efficient air turbine that is installed in a suspended ceiling grid, 2 feet by 2 feet. Each unit takes in resident hot ceiling air from below the suspended ceiling and silently transports it to the floor in the form of an almost imperceptible air column. Unlike a ceiling fan, the air is highly directed in a downward direction and not simply swirled around. Each unit is capable of equalizing somewhere between 1,000 and 1,500 square feet of open floor area; roughly a 40 foot diameter circle. PRODUCT OPTIONS Suspended Ceiling Models Remote Fan Speed Control Color Options Standard Off white Special color requests will be quoted INSTALLATION OPTIONS Suspended Ceiling Models The Airius Thermal Equalizers can be configured to any building requirements. A number of installation options are offered. Extension cord to receptacle box Direct to junction box WARRANTY All Airius Models There is a full warranty for one year from date of purchase on parts and workmanship. If defective while under warranty, a new unit will be sent at no charge, in exchange for the defective unit to be returned UPS collect. REFURBISH PROGRAM All Airius Models Avedon Development, LLC offers a refurbish program on all Airius Thermal Equalizers that are no longer under the one-year warranty. Any Airius Thermal Equalizer that is no longer under warranty can be returned to Avedon Development, LLC and will be refurbished, or replaced, for one half the current price of the Airius Thermal Equalizer Model. The Refurbish Program does not cover units that are damaged beyond the normal expected usage of the product. BUSINESS PARTNER Avedon Development is a proud partner of Rebuild America, a network of partnerships that foster energy efficiency and renewable energy in commercial, government and public housing buildings. For more information about Rebuild America, visit www.rebuild.org. Page 7 of 9

CASE STUDY ENERGY REDUCTION RESULTS AVEDON ENGINEERING, INC. Over the past year, Avedon Development, LLC has been developing the Airius Thermal Equalizer product line to reduce the effects of heat rising to the ceiling, and thus reduce the related excess energy consumption. Following is information documenting the energy savings experienced to date in our facility while testing various prototypes and the current production Airius Thermal Equalizer models. The information includes historical energy usage and average temperature provided by Xcel Energy for our tool room and corporate office facility in Longmont, CO. The building is approximately 45,000 square feet including 24,000 square feet of two-story offices and 21,000 square feet in the tool room and other operations- related rooms such as storage, workshops and locker rooms. The tool room has a ceiling height of 30 feet. At the west end there is a large overhead door that is opened frequently. The Airius Thermal Equalizers are installed only in the tool room. The initial Airius Thermal Equalizer prototypes, two units (2), were initially tested in the tool room for five (5) days in the Dec 2003/Jan 2004 billing period. Prior to this, there was no thermal equalization system in place in the facility. During the Jan/Feb 2004 billing period, three (3) prototypes operated for three of the four weeks of the period. In the Feb/Mar billing period, five (5) prototype units operated and one (1) pre-production unit were operating for the entire time period. Additional pre-production units were installed during the Mar/Apr billing period. Fourteen production units are now installed. The results are summarized below: (1) The average temperature for the Dec 2003/Jan 2004 billing period was 31 degrees. Energy usage was reduced from the Nov/Dec 2003 baseline by 6.6 % by the two prototype Airius units operating for 5 days. (2) The average temperature for the Jan/Feb 2004billing period was lower, 29 degrees, than Dec 2003/Jan 2004. Energy consumption was further reduced by 13.2 % from the Nov/Dec 2003 baseline by the three Airius units operating for three of the four weeks. (3) The average temperature for the Feb/Mar billing period increased to 44 degrees. Energy consumption was reduced by over 40 % from previous similar time period/average temperature billing periods by the five prototype units and one pre-production unit operating the entire period. (4) The energy consumption for the Mar/Apr billing period continued to decline significantly, over 80 %, from previous similar time period/average temperature billing periods with the installation of additional Airius Thermal Equalizer units. (5) Fourteen units are now installed in the tool room. Energy consumption has continued to decline to ever 90 % from previous billing period historical levels. The charts on the next page show detailed historical information including the actual numbers provided by Xcel Energy for the facility with both graphs and charts summarizing the data. Page 8 of 9

Therms Used May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr 2000-2001 1268 1013 1129 861 1049 1158 1973 4031 5243 4533 3782 2407 2001-2002 2052 393 33 24 26 122 537 2722 5165 4237 3689 2420 2002-2003 1497 829 22 26 44 237 2838 3996 4338 3025 3419 1844 2003-2004 679 24 12 14 23 1037 699 4042 3739 3508 1378 293 2004-2005 144 29 22 14 18 58 Avg Temp May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr 2000-2001 57 70 72 75 72 58 46 30 31 27 34 44 2001-2002 52 64 73 75 71 61 51 40 32 31 36 47 2002-2003 55 66 77 77 71 54 37 35 34 33 37 47 2003-2004 53 65 75 76 67 58 45 31 31 29 29 46 2004-2005 56 62 70 71 67 56 Xcel Energy Usage Therms Used 6000 5500 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0 1 2 3 4 5 6 7 8 9 10 11 12 Month 2000-2001 2001-2002 2002-2003 2003-2004 2004-2005 Page 9 of 9