Signal Tower. See More, Do More!

Similar documents
LA6 Series Sleek Design. Fully Customizable. Endless Possiblities.

2 Tones to select LU7

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

INSTRUCTION & SERVICE MANUAL

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Class 1 laser beam sensor safe for your eyes

X10 Mini, Midi & Maxi

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

M7100 Pressure Transducer

Class 1 laser beam sensor safe for your eyes

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

SENTINEL A - Fault Passage Indicator

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Class 1 laser beam sensor safe for your eyes

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Vaux Programming. TDD-ANPNx. Vdim+ Return. Connection to LED driver Connection to Control Model Number

Product Tests Report

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

INSTRUCTION & SERVICE MANUAL

Auer - Signal tower ECO Ø70 mm modular

SPECIFICATION FOR APPROVAL

LM40 Medium Intensity Aviation Obstruction Light

Dräger Polytron 7000 Fixed gas detector

E3M-V. Mark Sensor. Applications

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Snifter ATEX22 VERSION. User Manual. Distributor

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Laser Collimated Beam Sensor

PROFIBUS-PA Display RID 261 PROFIBUS-PA

TEMPERATURE CONTROLLER

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Explosion Proof Combination Signal db (A) / 5 Joule

SPECIFICATION FOR APPROVAL

Engineering Guideline. pac- Carriers Type Universal

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

About Tomar Audible Alarms 1000 & 1100 Power Alarm WEP Explosion Proof Power Alarm Siren

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

* Consult factory on conditions for approval acceptability

Dräger Polytron 8310 Stationary gas detector (DSIR)

EXPANDABLE SMART HOME SECURITY KIT

M2500 Engine Controller Installation Manual

Sensepoint XCL Fixed Gas Detector

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

QUALITY. Total Information Technology

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Faster Temperature (& Humidity) Chamber

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

SUNS International LLC. Presentation

standards: standards:

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

DESCRIPTION FEATURES WARNINGS APPLICATIONS

General Specifications

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

XLFE-4/1. Borosilicate glass globe

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

Output module (230 V)

SENTINEL D - Fault Passage Monitoring

INSTRUCTION MANUAL (ATEX / IECEx)

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Dräger Polytron 8000 Stationary gas detector (EC)

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Conformity Approvals Rated insulation voltage Ui

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

+ A B V B NO NC V COM PV PV

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Amphenol Renewable Energy Market

UDC100 Universal Digital Controller Specifications

COMITÉ EUROPÉEN DES ASSURANCES

INDEX. Ⅰ. Company Overview. Ⅱ. Business Line. Ⅲ. Business Planning. Ⅳ. Appending - Certificates

XVUC29 Ø60mm LED unit - steady/flash/rotate, multicolor unit, IP65, 24VAC/DC

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Circuit Breaker with Residual Current Protection (CBR)

TEMPORARY SPECIFICATION FOR REFERENCE

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Installation Instructions for W2H Series Signals

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Bulletin 855T 70 mm Control Tower Stack Lights

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Ultrasonic Reflective Sensor

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

CONTROL YOUR HOME FROM EVERYWHERE

Transcription:

Signal Tower See More, Do More! www.patlite.com

Specifications Dimensions (Unitmm) Model Rated Voltage Operating Voltage Range Standard Rated Power Consumption Maximum Wiring LA6- D - DC24 V ±10% of Rated Voltage LA6-5 D N-RYGBC 5W LA6-5 D B-RYGBC 6.5W LA6-3D N-RYG 3.5W LA6-3D B-RYG 4.5W LA6-5 D N-YYYYY 7W LA6-5 D B-YYYYY 8W LA6-3D N-YYY 4.5W LA6-3D B-YY 5.5W Environmental Condition Power Consumption test with alarm set at Alarm Sound No.1 at maximum volume Signal Wire Current Maximum 70mA Standby Current Maximum 15mA Operating Ambient Temperature -25 to +60 Operating Humidity Range Less than 90% RH (No Dew or Condensation) Storage Temperature Range -25 to +60 Storage Humidity Range Less than 90% RH (No Dew or Condensation) Mounting Location Indoor Only Mounting Direction Upright/Inverted Direction Protection Rating IP65 (With alarm: IP54) IEC 60529 Environmental Condition Install in an upright position LA6- LJ Sweep Durability: Total amplitude: 0.3 mmp-p (10-57.5 Hz), Acceleration: 20.0 m/s2 (57.5-150 Hz) Fixed pitch durability: Acceleration 20.0 m/s2 Vibration Resistance Sweep Durability: Total amplitude 0.3 mmp-p (10-57.5 Hz), LA6- TN Acceleration: 20.0 m/s2 (57.5-150 Hz) Fixed Vibration Frequency Durability: Acceleration 10.0 m/s2 JIS C 60068-2-6:2010 Environmental Condition Tested while installed in an upright position Insulation Resistance More than 1Mohm at DC500V between the power input lead and chassis. Withstand Voltage 500VAC for 1min between terminals and chassis without breaking insulation Display Color red (1000 mcd) yellow (1700 mcd) green (2600 mcd) blue (1000 mcd) white (1250 mcd) (Typical Luminous Intensity) Flash Rate Purple (800 mcd) pink (850 mcd) cyan (2150 mcd) lemon (2150 mcd) * Due to the characteristics of the LED elements, a variation in difference of the color tone and brightness of every product may occur. 60 ±2 fpm No. 1 2400Hz Continuous beep sound No. 2 2400Hz Rapid intermittent beep No. 3 2400Hz Long intermittent beep No. 4 2400Hz Fast intermittent beep Alarm Sound No. 5 3600Hz Continuous beep No. 6 3600Hz Rapid intermittent beep (Typical Frequency) No. 7 3600Hz Long intermittent beep No. 8 3600Hz Fast intermittent beep No. 9 2400Hz & 3375Hz Multiplexed Beep No. 10 2400Hz & 3600Hz Multiplexed Beep No. 11 4000Hz & 4800Hz Multiplexed Beep Sound Level Maximum: 85dB Environmental Condition Alarm Sound No.1 measured from the front direction of the alarm opening at 1m Volume Control Data Transfer Interface Transfer Cable Data Programming Application Software Mass (Tolerance 10%) Compliance Standards Remarks The set up button is the fourth step (Factory Default: Maximum). [Maximum] -> [-5dB drop from maximum (standard)] -> [-10dB drop from maximum (standard)] -> [OFF] (-> Returns to [Maximum]) Main Unit USB micro-b Terminal Female USB2.0/1.1 Interface, Transmission Rate: USB2.0/1.1/1.0 Charge /Data Transfer Micro USB (not included); Connector: USB Male- USB (MicroB) male Exclusive Application Software (Downloadable from our Homepage) LA6-3DTN B 480g LA6-3DLJ B 980g LA6-3DTN N 420g LA6-3DLJ N 930g LA6-5 DTN B 590g LA6-5 DLJ B 1090g LA6-5 DTN N 530g LA6-5 DLJ N 1040g EMC Directive (EN 61000-6-4, EN 61000-6-2) RoHS Directive (EN 50581) UL508, CSA-C22.2 No.14 KC ( KN 61000-6-4, KN 61000-6-2) FCC Part 15 SubpartB Class A CE Marking UL Recognized Component (File No.E215660) Direct Mount / Terminal Buss Type Mounting Hole Nameplate Location Model Code Front Direction (Alarm Direction) Mounting Hole Outer Dimension < Specification : Height > 5 - B : 330 3 - B : 264 5 - N : 290 3 - N : 224 Steel Pole & L Bracket Cable Type Signal Tower < Specification : Height > 5 - B : 320 3 - B : 254 5 - N : 280 3 - N : 214 (Unit: mm) Mounting Hole Wiring Hole ( TN Type) 2 Use φ23 for Cable Gland Top View Bottom View External Contact Classification No Flashing/Alarm Flashing/Alarm Flashing/Pulse Enable Common Line Don t Apply Voltage! External Contact Classification Flashing/Pulse Enable External Contact No Flashing/Alarm Flashing/Alarm Flashing/Pulse Enable Common Line Don t Apply Voltage! Flashing/Pulse Enable PLC Output Unit 2 LED Tier 1/ Input1 LED Tier 2/ Input2 LED Tier 3/ Input3 LED Tier 4/ Input4 LED Tier 5/ Input5 Alarm 1/ Input6 Alarm 2/ Input7 Mode Change Power Supply Wire Power Supply Wire Flashing/Alarm Type Lighting/Alarm External Contact LED Tier 1/ Input1 LED Tier 2/ Input2 LED Tier 3/ Input3 LED Tier 4/ Input4 LED Tier 5/ Input5 Alarm 1/ Input6 Alarm 2/ Input7 Mode Change Power Supply Wire Power Supply Wire Lighting/Alarm PLC Output Unit 1 Circuit Diagram Flashing/Alarm Type DC 24V (Class2) (Non-polarized) DC 24V (Class 2) http://www.patlite.com Inaba Bldg 4-11-14 Itachibori, Nishi-ku, Osaka, Japan 550-0012 International Division, Sales and Marketing Department TEL: +81-6-7688-5400 FAX: +81-6-7688-5401 E-mail: overseas@patlite.co.jp 20130 S. Western Ave. Torrance, CA 90501, U.S.A. TEL: +1-310-328-3222 FAX: +1-310-328-2676 E-mail: sales@patlite.com No.2 Leng Kee Road, #05-01 Thye Hong Centre, Singapore 159086 TEL: +65-6226-1111 FAX: +65-6324-1411 E-mail: sales@patlite.com.sg Room 512, Jufeng Business Building, No.697-3 Lingshi Road, Shanghai China 200072 TEL: +86-21-6630-8969 FAX: +86-21-6630-8938 E-mail: sales@patlite.cn To ensure correct use of these products, read the Instruction Manual prior to use. Failure to follow all safeguards can result in fire, electric shock, or other accidents.specifications are subject to change without notice. Am Soeldnermoos 8, D-85399 Hallbergmoos, Germany TEL.+49-811 9981 9770-0 FAX.+49-811 9981 9770-9 A-2603, Daesung-D-POLIS, 543-1 Gasan-dong, Geumcheon-gu, Seoul, 153-719 TEL.+82-2-523-6636 FAX.+82-2-861-9919 E-mail : sales@patlite.co.kr 7F. No. 91, Huayin St, Datong District Taipei, Taiwan R.O.C TEL.+886-(0)2-2555-1611 FAX.+886-(0)2-2555-1621 LOT 321 Batamindo Industrial Park, Jalan Beringin Mukakuning, Batam 29433 Indonesia TEL: +62-770-61-1123 FAX: +62-770-61-2444 ISO14001:2004 Certified Headquaters/Sanda Plant/Techno Center E-mail: info@patlite.eu E-mail: info@patlite.tw PATLITE ECO PROJECT For the benefit of mankind and the earth, Patlite is committed to developing environmentally friendly products. Catalog No. O-3108A 1411(P8) M/M(SM)A