Note: A summary of the applicable code sections is shown in the CEC _Table100A.

Similar documents
MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

TITLE 24 ICONOGRAPHY. Iconography System

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

PRESCRIPTIVE APPROACH

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

Best practices in lighting design to comply with California s Title 24 energy code

ASHRAE October 18, 2013

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

What s New in the 2013 Energy Code? Changes to mandatory Title 24 lighting requirements

Best practices in lighting design to comply with California s Title 24 energy code

WSA120: New Energy Codes and Lighting Controls

RESIDENTIAL LIGHTING Best practices in lighting design to comply with

Are LED s ready for Prime Time?

What You Need to Know About California Compliance T20, T24 and JA8 Chris Primous VP OEM National Accts and Industry Relations April 18, 2018

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

2005 Title 24 Outdoor Lighting Regulations Overview. 77 slides

A Guide to the Commercial Building Tax Deduction. Effective: January 1, 2006 to December 31, 2008 HL /07

C A L I F O R N I A E N E R G Y C O M M I S S I O N

Decoding 2016 Title 24, Part 6

1.6. Outdoor Lighting

ARCHWAY TM PASSAGE TM

2013 Nonresidential Appendices Appendix NA8-1. Appendix NA8 Luminaire Power... 1 NA8.1 Luminaire Power... 1

Nonresidential Outdoor Lighting Controls

Advances in Lighting Controls and the Impact of ASHRAE Requirements. Rich Rattray, LC OSRAM SYLVANIA

REVISIONS Summary of Change. 6/1/12 All Replaced entire document with new revision

California Title Design Guide for Smart Lighting Control and Energy Solutions

California Title Lighting and Lighting Controls Only

Code Review TITLE PRESENTED BY POURIA NIKNAM

Reduce lighting energy costs with controls

visual environment technologies etcconnect.com

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A

Lighting Control Strategies. to meet code requirements save energy and improve building performance

PD-32: Light Pollution

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

Advanced Lighting For Office

Advanced Lighting Solutions

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

InvestSmart Business Energy Upgrades Lighting Equipment Catalog 01/01/2018

Technical Report One

Hubbell Controls Application Guide to CA Title 24 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

NEW ENHANCED CAPITAL ALLOWANCE EXPLAINED NEW ECA EXPLAINED HELEN LOOMES 2013/2014 SLL MASTERCLASS

SenScape Luminaires Ideal for Covered Parking, Canopy and Low Bay Applications

Code Compliance Commercial Application Guide

Lighting Control Solutions for Parking Facilities

Application Guide to CA Title 24

Lighting Solutions for Active Workspaces

Design and Commissioning of Lighting Control Systems. Rick Miller, PE, LC, LEED AP RNM Engineering, Inc. October 18, 2012

IES/IDA Model Lighting Ordinance

Dimming Ballast + Controls and CALCTP Bonus. New Product Overview

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

Non-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use

CA TITLE 24 QUICK SOLUTIONS GUIDE FOR

ANSI/ASHRAE/IES

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Wireless Indoor Lighting Control System

ANSI/ASHRAE/IES

Office Title Solutions

High Performance Lighting. Terry Egnor Senior Consultant NBI

Eligible Prescriptive Measures List:

2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply

BUG stands for Backlight, Uplight and Glare. The acronym

Codes and Controls Commercial Building Energy Code Requirements for Light Control. Michael Jouaneh, CEM, LEED AP September 20, 2012

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

600 Watt Dimmer Install Guide

Design Guidelines for Exterior Lighting

Energy Management. The Smart Choice for Lighting Control and Energy Solutions

Lighting Application Guide for K-12 Classrooms

A Guide for Applicants and Lighting Designers

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Advances in Non-Residential Lighting Technologies

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Lighting Depth: Courtyard Franklin Care Center, Franklin Lakes, NJ

Advanced Lighting Control for High Building Performance

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

PSO Business Rebates Retrofit Lighting Technical Requirements

Fixture Controller. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALC/ALCE Part #: /

MANDATORY MEASURES DAYLIGHTING. (Reference: Sub-Chapter 4, Section 130)

Solid State Lighting

Manufacturing. Industrial Lighting & Controls Solutions

Emery County Senior Center Green River 06/07

Sensors Explained AUTOMATION

COMMERCIAL ENERGY SAVINGS GUIDE

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

Richmond Building Energy Challenge. Project List - Lighting Technologies

Lighting Controls: The Next Big Thing in Lighting. June 18th, 2014

Stocking Solutions. Downlights LED Panels Floods & Wall Packs

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

Parking Garage. Lighting & Control Solutions SLGUS.COM

Applied Lighting Controls

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

Transcription:

CALIFORNIA ENERGY COMMISSION 2016 Building Energy Efficiency Standards California Code of Regulations, Title 24, Part 6 Non-Residential Lighting Requirements Summary 3/27/2018 Scope: The California Title 24 Part 6-2016 Building Energy Efficiency Standards is a building code. Title 24 is a broad set of requirements for energy conservation, green design, construction and maintenance, fire and life safety, and accessibility that apply to the structural, mechanical, electrical, and plumbing systems in a building. Lighting installations in all newly constructed buildings and alterations of existing buildings must meet applicable Title 24 requirements. This summary only covers non-residential lighting requirements. Requirements: California's current Building Energy Efficiency Standards have been in effect as of January 1, 2017. The 2016 Standards focus on several key areas to improve the energy efficiency of newly constructed buildings and additions/alterations to existing buildings. California's 2016 Standards now align with ASHRAE 90.1 2013 standards and include more stringent lighting power density limits for many indoor and outdoor spaces. There is no such thing as a Title 24 compliant lighting product as Title 24 does not dictate lighting product performance criteria. T24 compliance is dependent upon the building design and installation. The specific Title 24 lighting requirements vary depending on the installation application. Refer to the following sections of the Title 24 Code for detailed lighting requirements: Section 100.1 Definitions and rules of construction Section 110.9 Mandatory requirements for lighting control devices and systems, ballasts and luminaires Section 130.0 Lighting controls and equipment - general Section 130.1 Indoor lighting controls that shall be installed Section 130.2 Outdoor lighting controls and equipment Section 130.4 Lighting control acceptance and installation certificate requirements Section 130.5 Electrical power distribution systems Section 140.3 Prescriptive requirements for building envelopes Section 140.6 Prescriptive requirements for indoor lighting Note: A summary of the applicable code sections is shown in the CEC-400-2015-037_Table100A. For non-residential buildings, there are mandatory requirements (requiring the use of lighting controls) and lighting power density limits. The Lighting Power Allotments are the established maximum lighting power (typically watts per square foot) that can be installed based upon the compliance approach used, the building type, and the type of primary function area. Lighting Power Allotments for an application are determined by one of the following four compliance approaches: Prescriptive Approach Complete Building Method Prescriptive Approach Area Category Method Prescriptive Approach Tailored Method Performance Approach

KEY INDOOR LIGHTING REQUIREMENTS Mandatory lighting controls are required: o MANUAL AREA CONTROLS (Section 130.1(a)). o MULTILEVEL LIGHTING CONTROLS (Section 130.1(b)) LED luminaires & LED source systems shall provide continuous dimming 10-100%. HID luminaires shall provide a minimum one step dimming between 50 70%. o AUTOMATIC SHUT-OFF CONTROLS (Section 130.1(c)). Occupant Sensing Controls are required for some spaces. o DAYLIGHT HARVESTING (Section 130.1(d)). o DEMAND RESPONSE (Section 130.1(e)). Consider Lighting Power Allowances (LPA) and Lighting Power Density Adjustment Factors (PAF). KEY OUTDOOR LIGHTING REQUIREMENTS All outdoor lighting must be equipped with photocontrol OR an astronomical time switch device that turns OFF all lighting when sufficient daylight is available (Section 130.2(c)1). All outdoor lighting must be controlled independently from other electrical loads and must use an automatic scheduling control (Section 130.2(c)2). Outdoor lighting is no longer required to be separately circuited from other lighting, only separately controlled. Outdoor luminaires mounted at 24 feet or less from grade: Automatic dimming is required during vacant periods (Section 130.2(c)3). When an area is unoccupied, controls should automatically reduce the lighting power of each luminaire at least 40% but no more than 90% or provide continuous dimming through a range that includes 40-90%. When the area becomes occupied, controls should automatically increase light levels. No more than 1,500 watts of lighting power shall be controlled together. Outdoor luminaires mounted over 24 feet do not require motion sensors. Some applications with outdoor luminaires rated for greater than 150 watts must comply with uplight and glare limits in the Luminaire Cutoff Requirements (Section 130.2(b)). Backlight, Uplight, and Glare (collectively referred to as "BUG" in accordance with IES TM-15-11, Addendum A) requirements in T24: o 1. There are no Backlight requirements in Section 130.2 of Part 6; and o 2. Maximum zonal lumens for Uplight shall be in accordance with TABLE 130.2-A; and o 3. Maximum zonal lumens for Glare shall be in accordance with TABLE 130.2-B. Consider Lighting Power Allowances (LPA). The CEC has specified lighting power allowances based on project locations and whether the surrounding environment is wild (dark), rural (characterized by low ambient light levels) or urban (characterized by higher ambient light levels). Summary of key changes between the 2016 Code and 2013 Code: 1. Clarification and simplification of existing language; removing exceptions no longer relevant ( 130.0 through 130.5 and 140.6 through 140.8). 2. Reductions to lighting power density (LPD) values in TABLES 140.6-B, 140.6-C, and 140.6-G. 3. Removal/addition of power adjustment factors (PAFs) ( 140.6(a)2). 4. Significant reductions in outdoor lighting power allowances (TABLE 140.7-A). 5. Clarification and streamlining of alteration requirements, including addition of a new compliance path that allows compliance by reducing the existing lighting power. For indoor lighting, this path foregoes bi-level control requirements but is otherwise identical to the 85 percent or less of lighting power allowance path.

Code Compliance There are two steps required to comply with the Energy Standards. 1. Meet all mandatory requirements by installing required devices, including controls, and ensuring that they perform all required functions. 2. Select your method of compliance by choosing either the Performance Approach or the Prescriptive Approach. The Prescriptive Approach is considered the most direct path to compliance. It is a set of prescribed performance levels for various building components, where each component must meet the required minimum efficiency. This approach is often used in retrofit projects. The Performance Approach builds on the Prescriptive Approach by allowing energy allotments to be traded between building systems, such as lighting, HVAC or the building envelope. This compliance approach requires using energy analysis software approved by the Energy Commission to model the overall energy performance of a building. The performance approach is often used for new construction projects. Lighting Compliance Process Flow Chart Example

Finding Suitable Products Certain devices must be certified to the Energy Commission as meeting California s Appliance Efficiency Regulations (Title 20, Section 1601 1608 of the California Code of Regulations). Others are regulated only under the Energy Standards (Title 24, Part 6). Products Regulated Under Title 20 Fluorescent lamp ballasts (Section 110.9(f)) Self-contained lighting control devices (Section 110.9) Time-switch lighting controls: automatic time-switch controls, astronomical time-switch controls, multi-level astronomical time-switch controls, outdoor astronomical time-switch controls Daylighting controls: automatic daylight controls, photo controls Dimmers Occupant sensing controls: occupant sensors, motion sensors, vacancy sensors, partial-on sensors, partial- OFF sensors Ceiling fan light kits Lamps Emergency Lighting Torchieres and Metal Halide Luminaires Power supplies Products Regulated Under the Energy Standards The following lighting control devices are regulated under Section 110.9 of the Energy Standards only: Part-night outdoor lighting controls (Section 110.9(b)5) Track lighting integral current limiter Supplementary overcurrent protection panels for use with line-voltage track lighting Field-assembled lighting control systems Venture Lighting Products Venture offers a broad range of lighting solutions to support California Title 24 compliance. For more information, please refer to individual product specs sheets which identify California Title 24 Ready products. Notes: LED luminaires & source systems for indoor applications shall provide continuous dimming 10-100%. LED luminaires & source systems for outdoor applications mounted at 24 feet or less from grade shall provide continuous dimming 40-90%. Some applications require that outdoor luminaires rated for greater than 150 watts comply with uplight and glare Luminaire Cutoff Requirements (Section 130.2(b)). HID indoor luminaires shall provide a minimum one step dimming between 50 70%. All Venture HID lamps (excluding Natural White) and ballasts which can be dimmed at least 50% are California Title 24 Ready. HID outdoor luminaires mounted at 24 feet or less from grade: All Venture HID lamps (excluding Natural White) and ballasts which can be dimmed at least 40% are California Title 24 Ready. HID outdoor luminaires mounted over 24 feet: All Venture HID lamps and ballasts are California Title 24 Ready. Dimming is not required.

REFERENCES CEC-400-2015-037-CMF BUILDING ENERGY EFFICIENCY STANDARDS FOR RESIDENTIAL AND NONRESIDENTIAL BUILDINGS CEC-400-2015-038-CMF REFERENCE APPENDICIES CEC-400-2015-033-CMF NONRESIDENTIAL COMPLIANCE MANUAL CEC-400-2015-025-CMF-REV NONRESIDENTIAL ALTERNATIVE CALCULATION METHOD REFERENCE MANUAL CEC-400-2015-039-CMF ALTERNATIVE CALCULATION METHOD APPROVAL MANUAL CLTC NONRESIDENTIAL LIGHTING AND ELECTRICAL POWER DISTRIBUTION GUIDE http://www.energy.ca.gov/title24/2016standards/ http://energy.ca.gov/title24/2019standards/rulemaking/ https://cltc.ucdavis.edu/title24