Rosemount 2090F Hygienic Pressure Transmitter

Similar documents
Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 3051P In-Line Pressure Transmitter. Product Data Sheet August , Rev BA

Rosemount 2051G Pressure Transmitter

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Sanitary Pressure Transmitter

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Emerson Wireless SmartPower Solutions

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 752 Remote Indicator

Rosemount 3051HT Hygienic Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Rosemount 248 Temperature Transmitter

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Absolute and Gage Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount 3051 Pressure Transmitter

Rosemount 248 Temperature Transmitter

Annubar Flowmeter Series

Rosemount 3051S MultiVariable Extension Supplement

Rosemount 248 Temperature Transmitter

Rosemount 3051 Pressure Transmitter and Rosemount 3051CF Series Flowmeter

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2051 Pressure Transmitter and Rosemount 2051CF Series Flowmeter

Quick Start Guide , Rev HA January Rosemount 248 Temperature Transmitter

Rosemount 3490 Series

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series MultiVariable Flowmeter

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Rosemount 4088B MultiVariable Transmitter with Bristol Standard Asynchronous/Synchronous Protocol (BSAP)/MVS Protocol

Rosemount 3144P Temperature Transmitter

Rosemount 3144P Temperature Transmitter

Net Safety ST3 XChem Toxic Gas Sensor

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3144P Temperature Transmitters with FOUNDATION Fieldbus Protocol. Quick Start Guide , Rev DA June 2016

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 2140 and 2140:SIS Level Detectors

Rosemount 705 Wireless Totalizing Transmitter

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Rosemount 644H Temperature Transmitters

Rosemount 2051T In-line Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter. Start

Rosemount 644H Temperature Transmitters

Quick Start Guide , Rev DA June Rosemount 644H (Device Revision 7 or Previous) and 644R Smart Temperature Transmitters

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Rosemount 848T FOUNDATION Fieldbus High Density Temperature Transmitter

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 2051T In-Line Pressure Transmitter

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Rosemount 3051L Level Transmitter

Rosemount 752 Fieldbus Remote Indicator

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 2130 Level Switch

Rosemount 644 Temperature Transmitter

Rosemount 3095MFC Compact Orifice Mass Flowmeter

Rosemount 644H Temperature Transmitters

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Rosemount 644 Temperature Transmitter

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Rosemount 848T High Density Temperature Measurement Family

Rosemount 3051CFC Compact Flowmeter

Emerson Plantweb Insight

Rosemount 2100 Series

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation

User s Manual YTA610 and YTA710 NEPSI Certification

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 3144P Temperature Transmitter

J. Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol.

Rosemount 2051CF DP Flowmeters

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

Rosemount 3051S MultiVariable Transmitter

Rosemount 8800D Series Vortex Flowmeter. Quick Start Guide , Rev FE October 2018

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter

Rosemount 702 Wireless Discrete Transmitter

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Temperature Measurement Transmitters for field mounting

Transcription:

Rosemount 2090F Hygienic Pressure Transmitter Product Data Sheet December 2017 00813-0100-4698, Rev GA Conforms to 3-A Sanitary Standards Features CIP/SIP service for process temperatures up to 284 F (140 C) Absolute or gage pressure ranges up to 300 psi Mounts with either 1 1 /2 or 2-in. Tri Clamp connection Performance of 0.10 percent with high accuracy option

Rosemount 2090F December 2017 Accurate, stable, and reliable pressure measurement for the hygienic industries Conforms to 3-A Sanitary Standards The hygienic design of the Rosemount 2090F conforms to 3-A Sanitary Standards, and is USDA accepted. The materials of construction are Generally Recognized As Safe (GRAS) by the FDA, making it the ideal choice for any hygienic application. Features CIP/SIP service with an upper temperature limit of 284 F (140 C) The Rosemount 2090F provides accurate, stable, and reliable pressure measurement, which makes it an ideal choice for pharmaceutical and food and beverage applications, including CIP/SIP service for process temperatures up to 284 F (140 C). Absolute or gauge pressure ranges up to 300 psi and 20:1 turndown Mounts with either 1 1 /2 or 2-in. Tri Clamp connection The Rosemount 2090F is available with both 1 1 /2 and 2-in. Tri Clamp process connections, designed for sanitary applications to easily connect to standard sanitary fittings without requiring special mounting hardware. 0.10 percent reference accuracy performance with P8 high accuracy option The single-filled sensor system of the Rosemount 2090F leads to outstanding accuracy due to full sensor compensation. Higher turndown allows for lower inventories by allowing you to measure pressures from 1.5 to 300 psi with only three transmitter ranges. Contents Ordering information............................. 3 Specifications.................................... 6 Product Certifications............................. 9 Dimensional drawings............................13 2

December 2017 Rosemount 2090F Ordering information Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 7 for more information on Material Selection. Table 1. Rosemount 2090F Pressure Transmitter Ordering Information The starred offerings ( ) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time. Model 2090F Product description Hygienic Pressure Transmitter Transmitter type A Absolute G Gage Pressure ranges (range/minimum span) Rosemount 2090FG Rosemount 2090FA 1 14.7 to 30 psi/1.5 psi (-1,01 to 2,1 bar/103 mbar) 0 to 30 psia/1.5 psi (0 to 2,1 bar/103 mbar) 2 14.7 to 150 psi/7.5 psi (-1,01 to 10,3 bar/517 mbar) 0 to 150 psia/7.5 psi (0 to 10,3 bar/517 mbar) 3 14.7 to 300 psi/40 psi (-1.01 to 20,7 bar/2,8 bar) 0 to 300 psia/40 psi (0 to 20,7 bar/2,8 bar) Output S 4 20 ma dc/digital HART Protocol Material of construction Process connection Isolating diaphragm Oil fill 2D 316L SST (Stainless Steel) 316L SST Neobee Process connection E 1 1 /2 in. Tri Clamp connection F 2 in. Tri Clamp connection Conduit entry 1 1 /2 14 NPT 2 M20 1.5 female Options (include with selected model number) Extended product warranty WR3 3-year limited warranty WR5 5-year limited warranty Digital display M5 LCD display, configured for percent of range Mounting brackets B4 SST mounting bracket with SST bolts 3

Rosemount 2090F December 2017 Table 1. Rosemount 2090F Pressure Transmitter Ordering Information The starred offerings ( ) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time. Product certifications E5 USA Explosionproof (XP) and Dust-Ignitionproof (DIP) ED ATEX Flameproof EM Technical Regulations Customs Union (EAC) Flameproof I5 USA Intrinsic Safety (IS) and Nonincendive (NI) K5 USA Explosionproof (XP), Dust-Ignitionproof (DIP), Intrinsic Safety (IS), and Nonincendive (NI) I1 ATEX Intrinsic Safety N1 ATEX Type n C6 Canada Explosionproof, Intrinsic Safety, Division 2, and Dust-Ignitionproof KB USA Explosionproof, Dust-Ignitionproof, Intrinsic Safety, Nonincendive and Canada Explosionproof, Intrinsic Safety, Division 2, and Dust-Ignitionproof KM Technical Regulation Customs Union (EAC) Flameproof and Intrinsic Safety KH ATEX Flameproof, Intrinsic Safety, USA Explosionproof, Dust-Ignitionproof, Intrinsic Safety, and Nonincendive ND ATEX Dust NK IECEx Dust K7 IECEx Flameproof, Dust, Intrinsic Safety, Type n K1 ATEX Flameproof, Dust, Intrinsic Safety, Type n K6 Canada Explosion-Proof, Intrinsic Safety, Division 2, Dust-ignitionproof, and ATEX Flameproof, Intrinsic Safety I3 China Intrinsic Safety IM Technical Regulation Customs Union (EAC) Intrinsic Safety E3 China Flameproof Terminal blocks T1 Transient protection Special certificate Q4 Calibration certificate Quality calibration certificate traceability certification Q8 Material traceability certification per EN 10204 3.1 Alarm limit C4 NAMUR alarm and saturation levels, high alarm CN NAMUR alarm and saturation levels, low alarm Special procedures P2 Cleaning for special service Calibration accuracy P8 0.1 percent accuracy to 10:1 turndown Typical model number: 2090F G 2 S 2D E 1 4

December 2017 Rosemount 2090F Standard configuration Unless otherwise specified, transmitter is shipped as follows: Engineering units: psi 4 ma: 0 psi 20 ma: Upper range limit Alarm output: high LCD display: 0 to 100 percent Custom configuration Calibration Transmitters are factory calibrated to customer's specified range. If calibration is not specified, transmitters are calibrated at maximum range. Calibration is at ambient temperature and pressure. Tagging The transmitter will be tagged, at no charge, in accordance with customer requirements. All tags are stainless steel. The standard tag is wired to the transmitter. Tag character height is 1 /8-in. (0.318 cm). A permanently attached tag is available upon request. Accessories Item description Calibration adapter, 1 1 /2-in. Use to connect a calibration device to a transmitter. Calibration adapter, 2-in. Use to connect a calibration device to a transmitter. Part number 02088-0197 -0011 02088-0197 -0012 5

Rosemount 2090F December 2017 Specifications Functional specifications Service Liquid, gas, vapor, and high-viscosity applications Ranges Range Output 4 20 ma Selectable HART Protocol Range down 20:1 Minimum span Load limitations Maximum loop resistance is determined by the power supply voltage, as described by the following equation: Maximum loop resistance = 43.5 (power supply voltage 10.5) 10.5 20 30 42.4 Voltage (Vdc) The Field Communicator requires a minimum loop resistance of 250 Ω for communication. Power supply Upper (URL) 1. Assumes atmospheric pressure of 14.7 psig. Load (Ohms) 1 2 3 1387 1000 500 0 1.5 psi (103 mbar) 7.5 psi (517 mbar) 40 psi (2,76 bar) 30 psi (2,1 bar) 150 psi (10,3 bar) 300 psi (20,7 bar) Operating Region Lower (LRL) 0 psia (0 bar) Lower (1) (LRL)(gage) 14.7 psig (-1,01 bar) External power supply required. Transmitter operates on 10.5 42.4 Vdc with no load. Reverse polarity protection is standard. Overpressure limits Temperature limits Process 4 to 284 F ( 20 to 140 C) Ambient 4 to 185 F ( 20 to 85 C) Storage Range Overpressure limit (1) 1 120 psi (8,3 bar) 2 300 psi (20,7 bar) 3 600 psi (41,4 bar) 1. Overpressure limit is dependent on the clamp/pressure adapter or sensor rating (whichever is lower). 22 to 185 F ( 30 to 85 C) Process temperatures above 185 F (85 C) require lowering the ambient limits by a 1.5:1 ratio: Max. ambient temperature in F = 85 (Process Temp 185) 1.5 Max. ambient temperature in C = Humidity limits 0 to 100 percent relative humidity Volumetric displacement Less than 0.0005 in 3 (0,008 cm 3 ) Turn-on time Performance within specifications less than 2.0 seconds after power is applied to the transmitter Failure alarm If self-diagnostics detect a sensor or microprocessor failure, the analog signal is driven either high or low to alert the user. High or low failure mode is user-selectable by a jumper on the transmitter. The values to which the transmitter drives its output in failure mode depend on whether it is factory-configured to standard or NAMUR-compliant operation. The values for each are as follows: Standard operation 85 (Process Temp 85) 1.5 Linear output: 3.9 I 20.8 Fail high: I 21.75 ma Low: I 3.75 ma 6

December 2017 Rosemount 2090F NAMUR-compliant operation Linear output: 3.8 I 20.5 Fail high: I 22.5 ma Low: I 3.6 ma Transmitter security Activating the transmitter security function prevents changes to the transmitter configuration, including local zero and span adjustments. Security is activated by an internal jumper. Performance specifications Zero-based spans, reference conditions, and 316 SST isolating diaphragm Reference accuracy ±0.20 percent of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability. High accuracy (P8) option: ±0.10 percentof calibrated span to 10:1 turndown Ambient temperature effect per 50 F (28 C) ±(0.15% URL + 0.15% span) from 1:1 to 20:1 Stability ±0.10 percent of URL for one year, reference stability Time response Total response time (1) 145 ms Update rate 22 times per second 1. Nominal total response time at 75 F (24 C) reference conditions. Vibration effect Less than ±0.1 percent of upper range limit when subjected to vibration of peak to peak constant displacement of 4 mm (5 to 15 Hz) and constant acceleration of 2 g (15 to 150 Hz) and 1 g (150 to 2000 Hz) Power supply effect Less than ±0.005 percent of calibrated span per volt Electromagnetic compatibility (EMC) Meets all industrial environment requirements of EN61326 and NAMUR NE-21 (1). Maximum deviation < 1 percent span during EMC disturbance (2). 1. NAMUR NE-21 does not apply to low-power (Transmitter output option code N). 2. During surge event device may exceed maximum EMC deviation limit or reset; however, device will self-recover and return to normal operation within specified start-up time. Mounting position effect Zero shift of up to 5.0 inh 2 O (12,4 mbar), which can be calibrated out. No span effect. Physical specifications Material selection Emerson provides a variety of Rosemount product with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser s sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product, materials, options and components for the particular application. Emerson is not in a position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product, options, configuration or materials of construction selected. Electrical connection 1 /2 14 NPT or M20 1.5 conduit entry Process wetted parts Isolating diaphragm 316L SST Process connector 316L SST Transmissible Spongiform Encephalopathy (TSE) Declaration Emerson certifies no process wetted components used in this product contain substances of animal origin. Materials used in the production or processing of wetted components for this products meet the requirements stated in EMA/410/01 Rev. 3 and ISO 2242-1:2015. Wetted components in this product are considered free of TSE. Non-wetted parts Electronics housing Low-copper aluminum Enclosures meet NEMA Type 4X, IP66, and IP68 when properly installed Paint Polyurethane Cover O-rings Buna-N 7

Rosemount 2090F December 2017 Paint Polyurethane Fill fluid Neobee M-20 Weight Approximately 2.74 lb (1,24 kg) 8

December 2017 Rosemount 2090F Product Certifications Rev 2.0 European Directive Information A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at. Ordinary Location Certification As standard, the transmitter has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). North America E5 I5 C6 USA Explosionproof (XP) and Dust-Ignitionproof (DIP) Certificate: 1015441 Standards: FM Class 3600 2011, FM Class 3615 2006, FM class 3616 2011, FM Class 3810 2005, ANSI/NEMA 250 1991 Markings: XP CL I, DIV 1, GP B, C, D; DIP CL II, DIV 1, GP E, F, G; CL III, DIV 1; T5( 50 C T a +85 C); Conduit Seal Not Required; Type 4X USA Intrinsically Safe (IS) and Nonincendive (NI) Certificate: 1015441 Standards: FM Class 3600 1998, FM Class 3610 2010, FM Class 3611 2004, FM Class 3810 1989 Markings: IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F, G; Class III T4( 50 C T a +70 C); when connected per Rosemount drawing 02088-1024; NI CL 1, DIV 2, GP A, B, C, D; Type 4x Canada Explosionproof, Intrinsically Safe, and Division 2, and Dust-Ignitionproof Certificate: 1015441 Standards: CAN/CSA C22.2 No. 0-M91 (R2001), CSA Std C22.2 No. 25-1966, CSA Std C22.2 No. 30-M1986, CAN/CSA-C22.2 No. 94-M91, CSA Std C22.2 No. 142-M1987, CAN/CSA-C22.2 No. 157-92, CSA Std C22.2 No. 213-M1987, ANSI-ISA-12.27.01-2003 Markings: Explosionproof for Class I, Division 1, Groups B, C and D; Class II, Groups E, F, and G; Class III; Intrinsically Safe Class I, Division 1 when connected in accordance with Rosemount drawing 02088-1024, Temperature Code T3C; Ex ia; Class I Division 2 Groups A, B, C and D; Type 4X; Factory Sealed Europe ED ATEX Flameproof Certificate: KEMA97ATEX2378X Standards: EN60079-0:2012 + A11:2013, EN60079-1:2014, EN60079-26:2015 Markings: II 1/2 G Ex db IIC T6 T4 Ga/Gb, T6( 60 C T a +70 C), T4/T5( 60 C T a +80 C) Special Condition for Safe Use (X): 1. This device contains a thin wall diaphragm. Installation, maintenance and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer s instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime. 2. Flameproof joints are not intended for repair. 3. Non-standard paint options may cause risk from electrostatic discharge. Avoid installations that could cause electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information. I1 ATEX Intrinsic Safety Certificate: BAS00ATEX1166X Standards: EN60079-0:2012+A11:2013, EN60079-11:2012 Markings: II 1 G Ex ia IIC T4 Ga ( 55 C T a +70 C) Table 2. Input Parameters Parameter Voltage U i Current I i Power P i Capacitance C i HART 30 V 200 ma 0.9 W 0.012 μf Special Condition for Safe Use (X): 1. The apparatus is not capable of withstanding the 500 V insulation test required by EN60079-11. This must be taken into account when installing the apparatus. 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a Zone 0 environment. N1 ATEX Type n Certificate: BAS00ATEX3167X Standards: EN60079-0:2012+A11:2013, EN60079-15:2010 Markings: II 3 G Ex na IIC T5 Gc ( 55 C T a +70 C) 9

Rosemount 2090F December 2017 Special Condition for Safe Use (X): 1. When fitted with a transient suppression terminal block, the equipment is not capable of withstanding the 500 V insulation test that is required by EN60079-15. This must be taken into account when installing the apparatus. ND ATEX Dust Certificate: BAS01ATEX1427X Standards: EN60079-0:2012+A11:2013, EN60079-31:2009 Markings: II 1 D Ex t IIIC T 50 C T 500 60 C Da 1. Cable entries must be used which maintain the ingress protection of the enclosure to at least IP66. 2. Unused cable entries must be filled with suitable blanking plugs which maintain the ingress protection of the enclosure to at least IP66. 3. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7 J impact test. International K7 Combination IECEx Flameproof Certificate: IECEx KEM 06.0021X Standards: IEC60079-0:2011, IEC60079-1:2014, IEC60079-26:2014 Markings: Ex db IIC T6 T4 Ga/Gb, T6( 60 C T a +70 C), T4/T5( 60 C T a +80 C); 1. The device contains a thin wall diaphragm less than 1 mm thickness that forms a boundary between EPL Ga (process connection) and EPL Gb (all other parts of the equipment). The model code and datasheet are to be consulted for details of the diaphragm material. Installation, maintenance and use shall take into account the environmental conditions to which the diaphragm shall be subjected. The manufacturer's instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime. 2. Flameproof joints are not intended for repair. 3. Non-standard paint options may cause risk from electrostatic discharge. Avoid installations that could cause electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information. IECEx Dust: see Approval Option NK IECEx Intrinsic Safety Certificate: IECEx BAS 12.0071X Standards: IEC60079-0:2011, IEC60079-11:2011 Markings: Ex ia IIC T4 Ga ( 55 C T a +70 C), Table 3. Input Parameters Parameter Voltage U i Current I i Power P i Capacitance C i HART 30 V 1. When fitted with a transient suppression terminal block, the Rosemount 2090 is incapable of passing the 500 V isolation test. This must be taken into account during installation. 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a Zone 0 environment. IECEx Type n Certificate: IECEx BAS 12.0072X Standards: IEC60079-0:2011, IEC60079-15:2010 Markings: Ex na IIC T5 Gc ( 40 C T a +70 C) Special Condition for Safe Use (X): 1. When fitted with a transient suppression terminal block, the device is incapable of passing the 500 V isolation test. This must be taken into account during installation. NK IECEx Dust Certificate: IECEx BAS12.0073X Standards: IEC60079-0:2011, IEC60079-31:2008 Markings: Ex t IIIC T 50 C T 500 60 C Da Table 4. Input Parameters Parameter Voltage U i Current I i 200 ma 0.9 W 0.012 μf HART 36 Vdc 24 ma 1. Cable entries must be used which mention the ingress protection of the enclosure to at least IP66. 2. Unused cable entries must be filled with suitable blanking plugs which maintain the ingress protection of the enclosure to at least IP66. 3. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7 J impact test. 10

December 2017 Rosemount 2090F China E3 China Flameproof Certificate: GYJ15.1506X Standards: GB3836.1-2010, GB3836.2-2010 Markings: Ex d IIC T6/T4 Gb, T6( 20 C T a +40 C), T4( 20 C T a +80 C) 1. The ambient temperature is as follows: I3 T a Temperature class 20 C T a 80 C T4 20 C T a 40 C T6 2. The earth connection facility in the enclosure should be connected reliably. 3. During installation in hazardous location, cable glands, conduits, and blanking plugs, certified by state-appointed inspection bodies with Ex d IIC type of protection, should be used. 4. During installation, use and maintenance in explosive gas atmospheres, observe the warning Do not open when energized. 5. During installation, there should be no mixture harm to flameproof housing. 6. End user is not permitted to change any components insides, but to settle the problem in conjunction with manufacturer to avoid damage to the product. 7. Maintenance should be done in non-hazardous location. 8. During installation, use and maintenance of this product, observe the following standards: GB3836.13-2013, GB3836.15-2000, GB3836.16-2006, GB50257-2014. China Intrinsic Safety Certificate: GYJ15.1508X Standards: GB3836.1-2010, GB3836.4-2010, GB3836.20-2010 Markings: Ex ia IIC T4 Ga 1. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a zone 0 environment. 2. This apparatus is not capable of withstanding the 500 V r.m.s. insulation test required by Clause 6.3.12 of GB3836.4-2010. 3. The ambient temperature is: T a 4. Intrinsically safe parameters: Temperature class 55 C T a 70 C T4 Parameter Voltage U i Current I i Power P i Capacitance C i Inductance L i HART 30 V 200 ma 0.9 W 0.012 μf 0 mh 5. The product should be used with Ex-certified linear associated apparatus to establish explosion protection system that can be used in explosive gas atmospheres. Wiring and terminals should comply with the instruction manual of the product and associated apparatus. 6. The cables between this product and associated apparatus should be shielded cables (the cables must have insulated shields). The shield has to be grounded reliably in a non-hazardous area. 7. End users are not permitted to change any internal components, but to settle the problem in conjunction with the manufacturer to avoid damage to the product. 8. During installation, use and maintenance of this product, observe the following standards: GB3836.13-2013, GB3836.15-2000, GB3836.16-2006, G3836.18-2010, GB50257-2014. 11

Rosemount 2090F December 2017 Technical Regulations Customs Union (EAC) EM EAC Flameproof Markings: Ga/Gb Ex db IIC T4...T6 X, T4/T5 (-60 C T a +80 C),T6 (-60 C T a +70 C) Special Condition for Safe Use (X): See certificate for special conditions. IM EAC Intrinsically Safe Markings: 0Ex ia IIC T4 Ga X (-55 C T a +70 C) See certificate for special conditions. Combinations K1 Combination of ED, I1, ND, and N1 K5 Combination of E5 and I5 K6 Combination of C6, ED, and I1 KB Combination of K5 and C6 KM Combination of EM and IM KH Combination of ED, I1, and K5 Conduit plugs and adapters IECEx Flameproof and Increased Safety Certificate: IECEx FMG 13.0032X Standards: IEC60079-0:2011, IEC60079-1:2007-04, IEC60079-7:2006-07 Markings: Ex de IIC Gb ATEX Flameproof and Increased Safety Certificate: FM13ATEX0076X Standards: EN60079-0:2012, EN60079-1:2007, EN60079-7:2007 Markings: II 2 G Ex de IIC Gb Table 5. Conduit Plug Thread Sizes Thread Identification mark Table 6. Thread Adapter Thread Sizes Male thread M20 1.5 6H Identification mark M20 1 /2 14 NPT 1 /2 14 NPT 3 /4 14 NPT 3 /4 14 NPT Female thread M20 1.5 6H Identification mark M20 1 /2 14 NPT 1 /2 14 NPT PG 13.5 PG 13.5 1. When the thread adapter or blanking plug is used with an enclosure in type of protection increased safety e the entry thread shall be suitably sealed in order to maintain the ingress protection rating (IP) of the enclosure. 2. The blanking plug shall not be used with an adapter. 3. Blanking Plug and Threaded Adapter shall be either NPT or Metric thread forms. G 1 /2 and PG 13.5 thread forms are only acceptable for existing (legacy) equipment installations. M20 1.5 M20 1 /2 14 NPT 1 /2 NPT G 1 /2A G 1 /2 12

December 2017 Rosemount 2090F Dimensional drawings Figure 1. Rosemount 2090F 5.13(130) 4.29 (109) B 3.85 (98) F A C 4.71 (120) D A. Terminal connection side B. Optional display C. Transmitter circuity side E D. 2 1 /4 20 UNC 2BX depth 0.60 mounting holes E. 1 1 /2- or 2-in. Tri Clamp connection F. Certification tag Note: M20 1.5 female is also available as option. Dimensions are in inches (millimeters). 13

Rosemount 2090F 00813-0100-4698, Rev GA Product Data Sheet December 2017 Global Headquarters Emerson Automation Solutions 6021 Innovation Blvd. Shakopee, MN 55379, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@Emerson.com North America Regional Office Emerson Automation Solutions 8200 Market Blvd. Chanhassen, MN 55317, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RMT-NA.RCCRFQ@Emerson.com Latin America Regional Office Emerson Automation Solutions 1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA +1 954 846 5030 +1 954 846 5121 RFQ.RMD-RCC@Emerson.com Europe Regional Office Emerson Automation Solutions Europe GmbH Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland +41 (0) 41 768 6111 +41 (0) 41 768 6300 RFQ.RMD-RCC@Emerson.com Asia Pacific Regional Office Emerson Automation Solutions 1 Pandan Crescent Singapore 128461 +65 6777 8211 +65 6777 0947 Enquiries@AP.Emerson.com Middle East and Africa Regional Office Emerson Automation Solutions Emerson FZE P.O. Box 17033 Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates +971 4 8118100 +971 4 8865465 RFQ.RMTMEA@Emerson.com Linkedin.com/company/Emerson-Automation-Solutions Twitter.com/Rosemount_News Facebook.com/Rosemount Youtube.com/user/RosemountMeasurement Google.com/+RosemountMeasurement Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and Rosemount logotype are trademarks of Emerson. HART is a registered trademark of the FieldComm Group. 3-A is a registered trademark of 3-A Sanitary Standards, Inc. NEMA is a registered trademark and service mark of the National Electrical Manufacturers Association, Inc. Neobee is a registered trademark of Stepan Specialty Products, LLC. All other marks are the property of their respective owners. 2018 Emerson. All rights reserved.