1 Technical Specifications PSH - SERIES Hydronic Heating / Electric Cooling Self contained, high efficiency thru-the-wall heating & cooling unit Heating - 12000-63000 Btuh Cooling - 12800 Btuh, 16500 Btuh, 19500 Btuh, 24400 Btuh CONFORMS TO ANSI/UL STD. 1995, CERTIFIED TO CAN/CSA STD. C22.2 NO. 236 AND ANSI/AHRI STD. 390 FEATURES INLET OUTLET COMPATIBLE BOX SIZE Industry standard footprint for retrofit applications Appliance shell dimensions: 43-1/8" High x 28" Wide x 32 Deep Wall Sleeve dimensions where penetrating exterior wall: 44-7/8" High x 28-7/8" Wide Standard TAUPE color Custom color options are available FEATURES HEATING MODULE Up to 10.8 EER Up to 24400 Btuh Cooling Easily removable R-410A Air conditioning module Micro-Channel Condenser and Evaporator Coils High efficiency Copeland scroll compressor Pre-wired and pre-charged Up to 63000 Btuh Heating Easily removable hydronic heating modules containing 3 row or 4 row hot water coil 24VAC color coded din rail mounted terminals for easy thermostat wire connections 24VAC output signal for activating field installed water circulating pump or isolation valve Factory installed freeze protection to prevent water coil from freezing during non-use. Activates water circulation at 40 F and deactivates at 60 F. Plug-and-play installation and service CIRCULATION BLOWER Dual Inlet Blower for higher flow rates / reduced air noise Endura Pro Multi-Speed Electronically Commutated Motor for increased electrical efficiency SERVICE ADVANTAGES COOLING MODULE Indoor access to all parts & maintenance needs Innovative, dual slide-out chassis can be partially or fully removed for efficient servicing. Hot water coils are equipped with manual drain and vent valves for flushing water and releasing of trapped air during installation or servicing. Extended water inlet & outlet copper tube connections (3/4 water pipe) for easy installation. With spare modules, building management can perform quick swap outs, maintaining indoor conditions in the apartment/condo, while troubleshooting non functioning units off line. All control harnesses are separated with modular quick disconnects so module swap outs do not require time consuming rewiring. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada phone 866-820-8686 fax 705-725-1150 w w w. n a p o l e o n h e a t i n g a n d c o o l i n g. c o m
2 NOMENCLATURE P S C 040 A 018 A BRAND MODEL HEAT TYPE HEAT CAPACITY COOLING TYPE COOLING CAPACITY REVISION P=Condo Pack S=Single Packaged Vertical R=Roof Top P=Packaged Residential C - Gas Condensing S - Gas Standard E - Electrical H - Hydronic D - Duct only (No heat) i.e. PSD000A012A Gas Condensing Heat designation 000 - Duct Only 015-15 000 Btu/h 030-30 000 Btu/h 040-40 000 Btu/h 050-50 000 Btu/h Electric Heat Heat designation 000 - Duct Only 005-5.0 kw 007-7.5 kw 010-10 kw 015-15 kw Gas Standard(80%) Heat designation 000 - Duct Only 026-26 000 Btu/h 038-38 000 Btu/h 051-51 000 Btu/h 064-64 000 Btu/h Hydronic Heat Heat designation 000 - Duct Only 030-30 000 Btu/h 042-42 000 Btu/h A, B, C... Air Conditioning 000 - Blower Only 012-12 000 Btu/h / 1.0 Ton 018-18 000 Btu/h / 1.5 Ton 024-24 000 Btu/h / 2.0 Ton 030-30 000 Btu/h / 2.5 Ton A - Air Conditioning - std. eff. Rev A B - Air Conditioning - std. eff. Rev B C - Air Conditioning - high eff. H - Heat Pump - std. eff. P - Heat Pump - high eff. F - Blower Only (No Cool) i.e. PSC040F000A Example: PSC040B018A - Condo Pack - Single Packaged Vertical - Condensing Gas heating 40k Btu/h - Rev B AC 1.5 ton - Rev A Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada phone 866-820-8686 fax 705-725-1150 www. napoleonheatingandcooling. com
3 SPECIFICATIONS ELECTRICAL AND PHYSICAL DATA TABLE 1. Electric and Physical Data COMPRESSOR OUTSIDE FAN MOTOR INDOOR BLOWER Model No. HP Voltage/Hz/Phase Voltage Range Minimum Circuit Ampacity (A) Max. Overcurrent protection device (A) Comp. Rated Load Amps (RLA) Comp Locked Rotor Amps (LRA) Nominal RPM Rated Load Amps Cond. Motor HP Wheel Dia x Width (in x in) Rated Load Amps PSH030A012A 10.7 15 5.5 26 1 1/6 10 x 6 2.8 1/3 208-230/60/1 197-253 PSH030A018A 15.1 20 9 48 1 1/6 PSH030A024A 20.7 30 13.5 58.3 1 1/6 PSH030A030A 20.3 30 12.8 64 1.5 1/4 PSH030F000A 3.5 15 NA NA NA NA 1075 PSH042A012A 10.7 15 5.5 26 1 1/6 PSH042A018A 15.1 20 9 48 1 1/6 PSH042A024A 20.7 30 13.5 58.3 1 1/6 PSH042A030A 20.3 30 12.8 64 1.5 1/4 PSH042F000A 3.5 15 NA NA NA NA GENERAL PERFORMANCE DATA TABLE 2. COOLING HEATING Model No. Btuh EER CFM PSH030A012A-TP 12800 10.8 450 PSH030A018A-TP 16500 9.6 740 PSH030A024A-TP 19500 9.0 740 PSH030A030A-TP 24400 9.0 960 PSH042A012A-TP 12800 10.8 450 PSH042A018A-TP 16500 9.6 740 PSH042A024A-TP 19500 9.0 740 PSH042A030A-TP 24400 9.0 960 208V/230V Module No. Btu/Hr 30000 42000 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada phone 866-820-8686 fax 705-725-1150 www. napoleonheatingandcooling. com
4 HEATING MODULE PERFORMANCE MATRIX TABLE 3. Coil (FH x FL: 12" X 19") (3 ROW) Air FLOW (CFM) 388 529 744 908 971 Complete performance matrix from hydronic heating module GPM Fluid Pressure Drop (Ft. Water)@ 130 F Coil Capacity (Btu/hr) Inlet Water Temperature ( F) 120 F 130 F 140 F 150 F 160 F 1 0.65 11800 14000 16400 18900 21500 2 2.28 14100 16800 19600 22400 25200 3 4.77 14900 17800 20700 23700 26500 1 0.65 13600 16100 18700 21700 24600 2 2.28 16900 20100 23500 27000 30400 3 4.77 18200 21700 25300 29000 32600 1 0.65 15600 18500 21400 24700 28100 2 2.28 20500 24300 28400 32700 36900 3 4.77 22600 26800 31400 36000 40500 1 0.65 16600 19700 22800 26200 29800 2 2.28 22600 26700 31200 35900 40600 3 4.77 25200 29800 34900 40100 45200 1 0.65 16900 20100 23300 26700 30400 2 2.28 23300 27600 32100 37000 41900 3 4.77 26000 30900 36200 41500 46800 (4 ROW) 388 529 744 908 971 1 0.88 14000 16600 19300 22200 25100 2 3.02 16700 19800 23200 26500 29800 3 6.26 17600 21000 24400 27900 31400 1 0.88 16100 19100 22100 25400 28800 2 3.02 20400 24200 28200 32300 36400 3 6.26 21900 26100 30400 34800 39100 1 0.88 18300 21700 25200 28600 32600 2 3.02 24800 29400 34200 39300 44400 3 6.26 27500 32600 38000 43600 49000 2 3.02 27300 32400 37500 43100 48800 3 6.26 30800 36500 42600 48800 55100 4 10.52 32700 38800 45300 51900 58400 5 15.71 33900 40300 47100 53900 60500 3 6.26 31900 37800 44100 50600 57100 4 10.52 34000 40300 47200 54000 60800 5 15.71 35400 42100 49100 56200 63100 *All specifications and designs can change without notice to allow for on-going improvements. Images may not be exactly as shown. Consult with your owner s manual for current information. Check all local and national building codes and gas regulations. Napoleon is a registered trade mark of Wolf Steel Ltd. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada phone 866-820-8686 fax 705-725-1150 www. napoleonheatingandcooling. com
5 AIR FLOW TABLE 4. CFM at External Static Pressure (Inches of Water Column) for -3ROW COIL Speed Motor Tap# Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1 100% 999 967 939 909 875 833 780 682 595 544 2 85% 933 915 890 866 823 781 719 662 588 544 3 60% 779 755 734 707 673 643 609 578 537 484 4 35% 577 556 511 512 466 389 348 313 289 254 5 25% 472 421 388 340 292 251 229 199 TABLE 5. CFM at External Static Pressure (Inches of Water Column) for -4ROW COIL Speed Motor Tap# Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1 100% 980 943 918 883 852 800 750 633 578 495 2 85% 918 894 866 837 792 745 684 622 565 462 3 60% 768 737 716 684 656 622 582 555 515 461 4 35% 563 539 492 443 413 375 332 296 276 245 5 25% 458 404 371 322 276 234 218 198 TABLE 6. Model No. PSH030A012A PSH030A018A PSH030A024A PSH030A030A Available Motor Speed Taps Heating/Cooling Speed Heating/Cooling Speed Setting Model No. Setting Module Tap# Module Tap# HI 1 HI 1 CACM012A FACTORY 5 PSH042A012A FACTORY 5 CACM012A HI 4 HI 4 G - continuous fan 3 G - continuous fan 3 HI 1 HI 1 CACM018A FACTORY 3 PSH042A018A FACTORY 3 CACM018A HI 2* HI 2* G - continuous fan 5 G - continuous fan 5 HI 1 HI 1 CACM024A FACTORY 3 PSH042A024A FACTORY 3 CACM024A HI 2* HI 2* G - continuous fan 5 G - continuous fan 5 HI 1* HI 1* CACM030A FACTORY 1 PSH042A030A FACTORY 1 CACM030A HI NA HI NA G - continuous fan 5 G - continuous fan 5 *IMPORTANT: Do not use common motor speed tap for multiple functions; Connecting (any combination of) air conditioning blower speed, heating blower speed, and continuous fan speed to the same motor speed tap will cause the unit to malfunction. Each of the three blower functions must be connected to separate motor speed taps. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada phone 866-820-8686 fax 705-725-1150 www. napoleonheatingandcooling. com
6 DIMENSIONS WALL SLEEVE DIMENSIONS FOUR DIFFERENT WALL SLEEVE MODELS ARE DEPICTED BELOW: NOTE: TO IMPROVE RIGIDITY AND REDUCTION IN VIBRATION WALL MOUNTING BRACKETS CAN BE USED TO AFFIX WALL SLEEVE TO BUILDING SUB STRUCTURE FROM INSIDE OR OUTSIDE OF THE BUILDING. ENGINEER/ARCHITECT TO CONSULT WITH NAPOLEON ENGINEERING TO DETERMINE BRACKET LOCATION FOR SETTING THE DESIRED DEPTH OF WALL SLEEVE INTO WALL. CWSMUA CWSMUA15 CWSMUA17 CWSMUA19 DIMENSIONS FOR THE TOP PANEL (ITEM 1): <== CWSMUA <== CWSMUA15 <== CWSMUA17 WALL SLEEVE IS DIRECTLY LAGGED TO WALL SUBSTRUCTURE. 16.000 17.000 19.000 <== CWSMUA19 3 3 4 " 28 7 8 " POSITION A 1" POSITION B 42 1 4 " CENTRAL BRACE MOUNTING LOCATIONS 46 7 8 " 44 7 8 " 15 16 " 26 1 2 " 32 3 4 " 12.590 14.890 16.890 18.890 DIMENSIONS FOR THE SIDE PANELS (ITEM 3 & 4)): <== CWSMUA <== CWSMUA15 <== CWSMUA17 <== CWSMUA19 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada phone 866-820-8686 fax 705-725-1150 www. napoleonheatingandcooling. com
7 ENCLOSURE FOR CONDO PACK 0" MIN. CLEARANCE * 2" MIN. CLEARANCE 0" MIN. CLEARANCE 30" RECOMMENDED unobstructed clearance in front of the unit for servicing 29" REF. DOOR OPENING 1" REF 1.5" Ø (10" RECOMMENDED MIN. CLEARANCE FOR SERVICING) * If less then 10, servicing may be performed by opening the front door panels and the heating module may need to be removed to access components. Space required for Return Air Ducting must be considered. Flashing Seal around Sleeve and INSIDE wall 1" REF. CLEARANCE BETWEEN LEFT (HINGE) SIDE DOOR JAM AND CONDO PACK *** NOTE A 32 " *** DRAIN REQUIRED (1.5" Ø MIN.) FOR REMOVAL OF HEATING MODULE WATER DRAIN AND AC CONDENSATE Recommended unobstructed clearance in front of the unit ** Engineer/Architect - to consult with Napoleon Engineering to determine bracket location for setting the desired depth of Wall Sleeve into wall. A-A Flashing 2" MIN. CLEARANCE TO COMBUSTIBLE 32 1/8" REF. * **SECURE TO WALL 82" REF. 45 1/2" 45 3/8" 43 1/8" 44 7/8" REF. FLOOR 8" MIN. FABRICATED WOOD OR STEEL SUPPORT A DRAIN 16 " 12 9/16" Brick Wall PROTRUDE 1/2 MIN.-1 MAX. Seal around Sleeve and OUTSIDE wall PROTRUDE 1/2 MIN.-1 MAX. Brick Wall ROUGH OPENING TO SUIT 28 7/8" X 44 7/8" WALL SLEEVE 28 7/8" 44 7/8" REF. VIEW OF OUTSIDE WALL Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada phone 866-820-8686 fax 705-725-1150 www. napoleonheatingandcooling. com
CONDO PACK SHOWN IN WALL SLEEVE FLOOR 43 15 16 " 16" 20 1 2 " 5 3 8 " 24 1 28 1 4 " 4 " 3 1 8 " 8" AIR SUPPLY OUTLET 3 1 2 " 28" 29" ELECTRICAL CONNECTION WATER CONNECTIONS 3/4 WATER PIPES (7/8 OD) 45 1 2 " 1 8 " 45 3 8 " AC DRAIN 1 16 1 " 1 15 16 " 24 1 8 " 1 15 16 " 7 1 8 " AIR RETURN INLET 28 7 8 " WALL SLEEVE WATER INLET (SUPPLY) WATER OUTLET (RETURN) HEATING MODULE COOLING MODULE (AIR CONDITIONER) 12 9 16 " 25 1 16 " 32 1 8 " 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 8" MIN PHONE: 866-820-8686 FAX: 705-725-1150 Website: www.napoleonheatingandcooling.com General: hvac@napoleonproducts.com Technical inquiries: hvacsupport@napoleonproducts.com Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada phone 866-820-8686 fax 705-725-1150 www. napoleonheatingandcooling. com