SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

Similar documents
Electrical Safety Program

NFPA 70E Electrical Safety & Arc Flash Training

2014 National Electrical Code & NFPA 70E/Arc Flash

Electrical Safety Program.

PROTECTING AGAINST ARC FLASH HAZARDS

NFPA 70E Edition Update

NECA S System Approach to Electrical Safety for NFPA 70E

6/23/ National Electrical Contractors Association and Intec, Inc.

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

NECA S System Approach to Electrical Safety for NFPA 70E

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

NFPA 70E Elevates Safety. with Heightened Risk Awareness

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

Arc Flash Protection Training - NFPA 70e Electrical Safety

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

Safety Best Practices Manual

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

Electrical Safety Compliance: NFPA 70E

Electrical Hazards and NFPA-70E: Protecting Your Employees

Safety requirements for voltage testing instruments

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Muskogee Public Schools. Lockout/Tagout. Program

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

How many time has your company been asked by an owner or customer to work on equipment energized?

PREPARING YOUR ORGANIZATION FOR NFPA 70E 2015

Fire Prevention Plan

OSHA-Required Trainings Offered by Ultimate Risk Services

NFPA 70E Update: Key Changes You Need to Know to Assure Compliance

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

Safety Meeting Topic #37 NFPA 70E What is it?

Chapter 18 Welding Table of Contents

Electrical Safety Requirements

NECA. Standard for Electrical Safety in the Workplace

F&S Control of Hazardous Energy Program

FIRE SAFETY AND PREVENTION POLICY

HOT WORK SAFETY PROGRAM:

Fire Prevention Plan

Janine Bain Rhonda Lewis Harland Hirst Sandra Olive David Johnson Edward Maurer Kathy Felsten Joe Halle

Title: Electrical Safety Effective Date: 11/28/2014 Control Number: THG_0038 Revision Number: 1 Date: 10/22/2015 Annual Review Completed: 5/13/2015

Centennial Energized Electrical Work Permit Instructions

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

Pilz Safety Lockout System (PSLS)

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

Stillwater Area Community Services Center Inc.

ENERGY CONTROL LOCKOUT/TAGOUT PROGRAM PLAN

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

SALISBURY ASSESSMENT SOLUTIONS

You and OSHA. What and How To Comply. PRESENTED BY: Joan M. Spencer Compliance Assistance Specialist Tampa Area Office

State of North Carolina Department of Environment and Natural Resources Division of Waste Management. Safety and Risk Management Program

Applying the 2012 NFPA 70E. Arc Flash Standard

DUQUESNE UNIVERSITY. Fire Protection System Impairment Program (Red etag Permit)

-SAMPLE- Safety Inspection Checklist: Manufacturing

Facility Risk Assessment Questionnaire

ELECTRICAL SAFETY GUIDELINE

General Safety Training

NFPA 70E Electrical Safety in the Workplace

Rutgers Environmental Health and Safety (REHS)

This section applies to the use of cord- and plug-connected equipment, including cord sets (extension cords).

X-Ray Protection Program

Professional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ...

Electrical Safety for Facility Managers and Building Owners

General Safety Training

California State University Bakersfield Radiation Safety Program Revised November 2017

Board Policy 6819 Fire Safety and Prevention Plan

Health and Safety Plans Health and Safety Policy Statement Fire Prevention Plan Objective

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

PREVIEW COPY. Table of Contents. Annexes and Supplemental Materials Lesson One Article 90: Introduction and Purpose... 3

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

HEALTH AND SAFETY MANUAL

WORKPLACE SAFETY INSPECTION CHECKLIST

Brian McCauley December 2017

Patrick County Horizons Jeb Stuart Hwy. Stuart, Va

EFCOG Best Practice #121

IIPP. Injury & Illness Prevention Program Hartog Drive San Jose CA Responsibilities. Workplace Hazards. Training. Incident Investigations

PART V: WORKING WITH LASERS

Occupational Safety Next Review Date: 12/20/17. Scope: University Wide Original Creation Date: 2009

West Virginia University Laser Safety Program

UC Irvine Environmental Health & Safety TITLE: FIRE WATCH AND OUT OF SERVICE NOTIFICATION

SECTION 1-1 SAFETY PRECAUTIONS

Contractor Environment, Safety & Health (ESH) Briefing. Suite 100 Bldg. 726 Billerica, MA

HARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

Contractor Safety. Workplace Safety & Environmental Division

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

Fire Evacuation Plan Bressler Research Building. UMB POLICE or

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

National Electrical Code

1.3 REFERENCE STANDARDS

Energized Electrical Work Review. Thomas Jefferson National Accelerator Facility

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

Fire Prevention Plan. California State University, Chico

Transcription:

Policy Title: Electrical Safety Work Practice Program Policy Number: UNIV-EHS 430 Policy Approved: January 2014 Policies Superseded: FINA-730 Policy Management Area: Environmental Health and Safety Created/Revision(s): July 2017/December 2013, September 2017 SUMMARY: The Electrical Safety Policy establishes and prescribes procedures that will assure compliance with all federal, state and local regulations applicable to electrical work, and reduce the number of incidents and losses associated with the operation, maintenance and repair of electrical equipment and devices I. DEFINITIONS: A. Qualified employees - individuals who, through training and/or experience, are permitted to work on or near exposed energized electrical equipment or parts. The work conducted by a qualified employee will involve either direct contact or contact by means of tools and materials. A qualified individual must possess at minimum an Electrical Journeyman s license from a governmental agency. B. Unqualified employees - individuals who are not permitted to physically work on exposed energized electrical equipment, parts, or repairs electrical devises; but who will have this type of equipment in their work area. An unqualified employee will not get closer than 3.5 feet or posted Arc Flash Boundary away from an open energized circuit or panel. II. POLICY: A. s (CCU s) primary goal is to operate, maintain and repair all electrical equipment and devices in a safe and proper manner to protect students and employees from potentially hazardous or unsafe conditions. Guidelines and procedures outlined in this policy have been developed to help ensure safe work procedures and comply with Occupational Safety and Health Administration (OSHA) General Industry Standard 29 CFR 1910.301 through 1910.399 (Subpart S) and OSHA Construction Industry Standard 29 CFR 1926.400 through 1926.449 (Subpart J), National Fire Protection Association (NFPA) 70 E, National Electric Codes (NEC), state, and local building codes. The Page 1 of 7

following objectives will be met in order to accomplish this goal: 1. All electrical equipment and devices will be free from recognized hazards that are likely to cause injury or death. 2. Electrical safety procedures will be followed and proper protective equipment is provided to protect employees from electrical hazards and risk N Table 130.7(C)(14). 3. Electrical circuit equipment will be properly labeled to meet NFPA 70 E (2015 edition) Hazard/Risk Category Classification (Arc Flash Boundary) requirements by individual circuit calculations outlined in NFPA 70 E (2015 edition), Informational Annex D, or use NFPA 70 E (2015 edition) Table 130.7 (C)(15)(a). 4. Electric circuits will be marked in such a way to indicate their purpose and the location of the disconnect panel or energy source. 5. Arc flash and shock boundaries will be maintained around electrical equipment, and proper personal protective equipment outlined in NFPA 70 E (2015 edition), Table 130.7(C)(16) will be utilized by the qualified employee. 6. Each employee s specific job classification will be designated as qualified or unqualified with respect to potential electrical exposures. 7. Each employee s specific job classification will be designated as qualified or unqualified with respect to potential electrical exposures. 8. Qualified employees will de-energize electrical equipment according to NFPA 70 E and CCU Lockout/Tagout Policy (see policy UNIV-EHS 425). 9. Employees will utilize safe work practices that prevent contact with energized circuits and live electrical parts. 10. An Energized Electrical Work Permit (Appendix A) must be completed and approved prior to any work being performed on live circuits. 11. All electrical panels and associated equipment must have at least a 3.5 foot clearance or Arc Flash Boundary whichever is greater to provide an unobstructed boundary. 12. Electrical panel rooms must be kept clean of clutter and will not be used as general storage rooms. I. RESPONSIBILITIES A. Department Director - The Department Directors for both qualified and unqualified employees are responsible for the Electrical safety work Practices of their staffs. Every department must keep a current list of qualified employees and the name of at least one electrically knowledgeable person. The Safety Coordinator must receive a copy of each current list. Department Directors will ensure that proper protective equipment is available and used when necessary by their employees. B. Safety Coordinator The EHS Director is responsible for developing the written Electrical safety work Practice Program, with assistance from maintenance, and Page 2 of 7

EHS personnel. The Safety Coordinator will audit the entire program annually, and will ensure that required training is conducted for all affected employees. C. Supervisors - Each departmental supervisor is responsible for the day to day implementation and enforcement of the Electrical Safety Work Practice Program in their area of jurisdiction. Each department supervisor is responsible for notifying the safety coordinator when new installations and/or equipment need to have revision/additions made to the documented and implemented procedures. All procedures must be approved by the departmental supervisor before being implemented. Supervisors are responsible for the annual review of their employee s proficiency in following established work practices and procedures, and notifying the safety coordinator when employees need initial and refresher safety training. Documentation of annual reviews should be forwarded to the safety coordinator. Supervisors must ensure that required safety equipment is made available to employees required to perform electrical related duties. D. Qualified Employees - Qualified Employees are responsible for following procedures established in the Electrical safety work Practice Program. E. Unqualified Employees - Unqualified Employees are responsible for doing their best to avoid electrical shock and for notifying their supervisors if conditions exist which could lead to electrical shock. II. TRAINING A. Qualified Employees - Training will be in the classroom and/or on-the-job and will introduce and establish proficiency in electrical safety work practices. Training documents for employees will be kept on file for at least thirty (30) years past their last day of employment in the EHS Department files. All qualified employees will be trained in and become familiar with the following information: 1. The skills and techniques necessary to distinguish exposed live parts from other parts of electrical equipment. 2. The skills and techniques necessary to determine the nominal voltage of exposed live parts. 3. The clearance distances specified for various voltages to which the qualified person will be exposed. 4. Proper Lockout/Tagout procedures as outlined in Policy UNIV-EHS 425 used to de-energize electrical equipment before work is conducted. 5. The proper use of personal protective equipment, insulating and shielding materials, and insulated tools. 6. The safe and proper use of portable electrical equipment, including handling, visual inspection, grounding, conductive work locations and extension cords. 7. First aid, cardiopulmonary resuscitation (CPR), automatic external defibrillator (AED) and emergency procedures B. Unqualified Employees - All unqualified employees will be trained in and Page 3 of 7

become familiar with the following information: 1. The risks associated with energized equipment. 2. The tasks that can be done only by qualified employees. 3. The techniques to protect themselves when working around electricity. 4. The importance of obeying electrical hazard signs and tags. C. Training Frequency - Designated qualified and unqualified employees will receive initial training at the time of their employment and refresher training every three years. Additional training will be provided whenever there is a change in equipment or processes that will present a new hazard or when there is a change in electrical energy control procedures. Whenever a periodic inspection reveals that an employee has deviated from or has been inadequately trained regarding electrical safety work practices, said employee(s) will require repeat or additional training to re-establish employee proficiency and/or to introduce new or revised control methods and procedures as necessary. D. Random/Periodic Evaluations - The electrical safety program will be periodically evaluated by the EHS Department. Periodic evaluations will be performed to ensure that the electrical safety work practices are being properly implemented. Qualified and unqualified employees will be randomly evaluated during health and safety audits. Infractions will be reported immediately to the involved employee and his/her supervisor and will be documented in the inspection report. III. PROTECTICE MEASURES and EQUIPMENT A. Test Instruments and Equipment 1. Only qualified employees will perform test work on electrical circuits or equipment. 2. All test instruments, equipment and associated leads, cables, power cords, probes, and connectors will be visually inspected for external defects and damage before the equipment is used. If any defect or damage is noted that will expose the employee to injury, the item will be removed from service and will not be used until repairs and tests have been made. 3. Test instruments, equipment and their accessories will only be connected to the circuits and equipment for which they were designed and will only be used in the environment for which they are approved. They must be rated above the anticipated voltage of the circuit to be tested. B. Personal Protective Equipment (PPE) - Employees working in areas where there are potential electrical hazards will use electrically rated PPE that is appropriate for the specific parts of the body and that has the proper arc flash protection rating for the work being performed. 1. All qualified employees working on live electrical parts must utilize NFPA 70 E Table 130.7(C)(16) arc flash-rated PPE including approved insulating gloves, electrically rated steel-toed boots, safety glasses and face shield. Page 4 of 7

2. All qualified employees will be furnished fire and arc-rated (FR/AR) clothing. 3. Electrically rated insulated tools or handling equipment will be utilized if there is a potential risk that the items might make contact with conductors or live electrical parts. 4. Approved fuse handling equipment that is insulated for the circuit voltage must be used to remove or install fuses when the fuse terminals are energized. 5. Insulating materials, such as switchboard matting and insulated blankets, will be used when deemed necessary in work procedures. C. Protective Practices - The following is a list of electrical safety work practices that will be followed at : 1. Lockout/Tagout procedures will be used to deenergize electrical equipment before work is conducted. Verification of complete deenergization of the circuit is required prior to work startup. 2. When normally enclosed live parts are exposed for maintenance or repair, they will be guarded to protect unqualified persons from contact with live energized parts. Barricades will be used if necessary. If barricades are not sufficient, then attendants will be used. 3. All electrical switches, fuses and circuit breaker panels must be evaluated, rated and labeled as to the NFPA arc flash potential for the device. Any work done on these devices while energized must be performed by a qualified employee using the properly rated PPE. 4. Qualified employees will not approach or take any conductive object without an approved insulating handle closer than 4 feet to any exposed energized parts. Approved electrical gloves and sleeves must be utilized if approaching closer than 4 feet. 5. Employees and/or conductive tools will not come within 10 feet of any unguarded, energized overhead power line. 6. Conductive items, such as jewelry, watch bands, bracelets, rings, key chains, necklaces, etc., will not be worn if they could contact exposed energized parts. 7. Electrical extension cords will not be a substitute for permanent wiring. The minimum size of an extension cord will be 16 gauge copper wire, three-wire type, with one wire being a permanent ground. The extension cords must be in good condition with no damage to the outer protective insulation or the plug and receptacle ends. Damaged cords must be taken out of service immediately and repaired or destroyed. Sixteen-gauge extension cord repairs are prohibited and damaged ones must be destroyed. Larger gauge wire can be repaired by a qualified employee by installing new Nepco type ends and heat shrink insulation patches. Electrical tape repairs are not allowed on any extension cord. Extension cords must not be used in or routed through wet areas. 8. A Ground Fault Interrupt Circuit (GFIC) is required for all electrical outlets located in potentially wet locations (e.g., bathroom, laboratory, Page 5 of 7

kitchen), for outdoor extension cords, and for any construction site or building activity, including remodeling. Vending machine must be connected to a GFIC circuit regardless of location. 9. Flammable storage cabinets must be properly grounded per manufacturer s instruction. Bonding cables must be available in the interior of the cabinet to bond containers to the cabinet as well as to bond containers together when transferring contents between them. 10. Machines, branch circuits, and electrical equipment must have a separate switch in addition to the fuse or circuit breaker in the panel box to energize the device or circuit, i.e., light switches are available to energize lighting, and motor switches are available to start-up electric motors. 11. All electrical circuits must be properly phased as to current polarity. 12. Metal ladders are strictly prohibited for use on any electrical work. 13. Circuit breakers are not to be used as light switches or motor starters. Page 6 of 7

APPENDIX A Page 7 of 7