Powerflow Unvented water heater

Similar documents
POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

Handyflow Undersink HF05MVC

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Zen Boiling Tap Range

TH01B, TH02B, TH03B, TH04B

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Automatic Infrared Tap TAPIFR. Instruction Manual

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Unvented Electric Water Heater 10/15 litre Undersink

HS&S Alert No: 103 Date: 9 March 2017

SC2000Y, SC2000YST, SC2000YM

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Installation and User Instructions HS10U, HS15U.

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

Product Instruction Manual. Jetstream JET1600 (white) & JET1600BSS (brushed stainless steel) 1.6 kw automatic hand dryer V15.

Unvented Direct & Indirect Hot Water Cylinders (400L L)

Unvented water heater

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Unvented Direct & Indirect Hot Water Cylinders (400L L)

HOTFLO 10 / 15. Fitting Instructions and User Guide

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

AC500T, AC1000T, AC1500T, AC2000T

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

SEALED THERMAL STORE

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Quantum. Installation, User and Service Manual. Hot Spring

Instructions for Use Installation and Servicing

Multipoint Technical Data

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Alpha CombiMax 350 and 600

MULTIPOINT 30 & 50 Litre

EPU - WM30 EPU - WM 50 EPU - WM100

Technical and Installation manual All Models

MULTIPOINT SS H 50/80 & 100

Zircon Installation Manual

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS V 50/80 & 100

Instructions & Maintenance

INSTANTANEOUS ELECTRIC SHOWER

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

UNVENTED MAINS PRESSURE SOLAR WATER HEATERS 210, 250 AND 300 LITRE CAPACITY INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

PremierPlus Unvented Hot Water Cylinder Installation and User Manual

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

HOTFLO 10 / 15. Fitting Instructions and User Guide

MEGAFLO HE Iss 1

Unvented water heater

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

Megaflo HE issue 6

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

IMPORTANT: PLEASE READ ALL THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION

HW3 Handwash Installation and Operating Instructions

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

PremierPlus SystemFit Unvented Indirect Hot Water Cylinder Installation and User Manual

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

PremierPlus SystemFit Unvented Indirect Hot Water Cylinder Installation and User Manual

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

UNVENTED MAINS PRESSURE SOLAR WATER HEATERS 100 TO 300 LITRE CAPACITY DIRECT AND INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...

Congratulations! You've just purchased a new Santon tankless water heater and will soon begin to enjoy the benefits of going tankless.

T E C H C A L EBS-1 T High technology heating

Installation Manual EXCELSIOR Unvented Water Heater

TH100 Three in One Instant Hot Water Tap

Installation and Servicing Instructions

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

ZIP VARIPOINT II Direct unvented water heaters.

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

INSTALLATION & TECHNICAL MANUAL

Installation & User Instructions

INSTALLATION MANUAL. Domestic hot water tank with UK kit for air to water heat pump system EKHTS200AC EKHTS260AC EKHTSU200AC EKHTSU260AC EKUHWHTA

Mimosa dual control mixer shower Installation and operating instructions

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

Hotflo Vertical Litres Installation, operation and maintenance manual

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

Installation, operating and servicing instructions

Hotflo. Unvented point of use hot water

WATER HEATERS INSTALLATION MANUAL

Schuco SS-TC/SC Cylinders

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Installation and Servicing Instructions. Alpha GasSaver GS-1

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

ZIP AQUAFLO II Unvented storage cylinders

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

Transcription:

Product Instruction Manual Powerflow Unvented water heater 30, 50 and 90 litres v15.6/5

Thank you for purchasing a Powerflow series unvented electric water heater. The Powerflow is suitable for hand washing and dishwashing where a number of hot water outlets are required such as kitchens, schools, restaurants, washrooms and offices. The Powerflow is the ideal solution for light industrial, commercial and light domestic hot water requirements. Please read and understand these instructions before commencing installation, and leave them with the user when installation is complete. 1. Important safety points Installation must be undertaken by a competent installer trained in the installation of unvented water heating systems in accordance with building regulations G3. Building regulations G3 requires a temperature and pressure relief valve to be factory fitted. This must not be removed or blocked in any way. Installation must comply with the latest edition of the IEE wiring regulations. These units are very heavy. They must be securely fastened to a suitably strong wall using the fixings supplied. Remember to allow for the weight of the water (one KG per litre of capacity) when assessing the suitability of the wall. 2. Installation Overview Components Checklist Expansion Vessel 3/4" MBSP, precharge pressure 3.5 bar Pressure Reducing Valve, factory set at 3 bar Single Check Valve 15mm x 15mm compression Pressure (expansion) Relief Valve 1/2" BSP male inlet, 1/2" BSP female discharge, factory set at 6 bar Tundish 15mm x 22mm This unit must be installed vertically, with the pipes pointing downwards and the temperature and pressure relief valve at the top. Ensure the wall is strong enough to support the heater, including the weight of the water when full. This heater is not suitable for outdoor installation. Do not install where there is any risk of freezing. The heater is bulky and heavy, Do not attempt to lift alone.

Plan your installation carefully and choose a suitable position for the heater, allowing suitable space for accessories such expansion vessels, pipework and subsequent maintenance. See schematic Diagram 1 for the correct relative positions of the components. Diagram 1 Temperature and Pressure Relief Valve POWERFLOW Pressure (Expansion) Relief Valve Expansion Vessel Balanced Cold Water Draw Off Service Valve Hot Drain Cock To Drain (Waste) Check Valve Pressure Reducing Valve Cold Water Mains Fit all the components supplied, components may be supplied loose or connected to a mainfold. The manifold aids installation but does not alter the relative positions of the components. Do not remove the factory fitted temperature and pressure relief valve. Ensure in particular that there are no valves of any kind between the expansion relief vlave and the heater. Allow at least 400mm of space above and below the unity to permit for maintenance. Observe flow direction arrows on components. Wall mounting Drill holes for supplied heavy duty bolts to wall at the spacings shown in the table below (also See Diagram 2). Insert bolt hooks and tighten ensuring that they are secure then hang heater on the protruding hooks. B Diagram 2 A Model Vertical Bolt Spacing A (mm) Horizontal Bolt Spacing B (mm) PF30LC 270 320 PF50LC 520 320 PF90LC 430 320

Plumbing connections Connect ALL the plumbing valves in the sequence shown in diagram 1. The cold water inlet to the heater is marked BLUE and the hot water outlet is marked RED. Observe flow direction arrows on supplied valves. The drain valve must be fitted close to the COLD inlet to allow drain down if necessary. An isolating valve should be fitted UPSTREAM of all of the valves to allow the heater to be maintained without impacting on other facilities. Do NOT fit a service or other valves between the heater and the pressure relief (safety) valve as this could impede its correct operation. The pressure reducing valve is factory set at 3 bar. If a balanced cold water draw off is required this should be tee-ed off down stream of this valve. A balanced cold water feed is recommended as it ensures hot and cold water is supplied at the same pressure. Some mixer taps and thermostatic showers require hot and cold water to be to be at the same pressure for correct operation. The expansion vessel supplied must be supported using a bracket or similar fixing. Do not rely on the pipework alone it will not be strong enough. The orientation of the vessel is not important. When all valves are correctly fitted, open a hot tap and wait until the water flow is steady and without traces of air. Close the tap to allow the system to reach full pressure and carefully check system for leaks. Control valves may be supplied loosely connected for identification purposes, but these joins have not been leak tested. This must be done at installation. It is essential to also check the temperature pressure reflief valve connection to the heater for leaks. Note that a leak from the temperature and pressure reflief vlve may not be immediately obvious, as the connection is at the top of the heater and leaking water may in the first instance run down the pipework and collect in the heater insulation. Discharge pipe connections This product falls within the scope of Building Regulation G3 which stipulates certain conditions relating to the way any water discharge from relief valves is transported away. These conditions are designed to ensure that any discharge will not present a hazard to people or to property, and that any discharge is clearly visible so that the underlying cause is likely to be rectified promptly. The essential requirement of G3 in relation to water discharge is that the discharge pipe MUST terminate in a safe, visible position. In achieving this aim the G3 regulations strongly recommended that: The tundish is located within 500mm of the Temperature and Pressure Relief valve and it is wherever possible oriented vertically. It must be visible to occupants and positioned away from electrical devices. The discharge pipe has a vertical fall of at least 300mm immediately below the tundish. The discharge pipe below the tundish is at least 22mm diameter (i.e. one size larger than the Temperature and Pressure Relief valve outlet). The discharge pipe should be as straight and as short as is possible and positioned away from electrical components.

Diagram 3 illustrates an acceptable discharge pipe arrangement. The table below the diagram specifies how the maximum acceptable pipe length from the tundish to the final outlet depends on the pipe diameter and the number of bends (reference the chart on page 4 for pipe sizing). For example in 22mm copper with no bends the pipe could be up to 9m long. With two bends present the maximum length drops to 9.0m - (2 x 0.80m) = 7.4m. Diagram 3 Metal Discharge Pipe (D1) from Temperature Relief to Tundish Safety Device 600mm MAXIMUM Tundish 300mm MINIMUM Discharge Below Fixed Grating Metal Discharge Pipe (D2) from Tundish with Continuous Fall Fixed Grating Sizing of D2 Copper Discharge pipe for common temperature relief valve outlet size Valve outlet size Minimum size of discharge pipe (D1) Minimum size of discharge pipe (D2) from Tundish Maximum resistance allowed, expressed as a length of straight pipe (I.E. no elbows or bends) G1/2 15mm 22mm up to 9m Trapped Gully 28mm up to 18m 1.0m 35mm * to 27m 1.4m Resistance created by each elbow or bend 0.8m Electrical connections The heater is supplied pre-wired with appropriate cable. Electrical installation should conform to the latest edition of the IEE Wiring Regulations. Electrical supply should be capable of isolation via a user-accessible double pole isolation switch rated for a 13A supply. 3. Commissioning Visually re-confirm all plumbing and electrical connections are sound. Open a hot water tap and turn on mains water supply to the Powerflow heater. Allow unit to fill and leave tap running for a short time to flush out the pipework and purge any air from the system before closing the hot tap and checking the system for any leaks. Check the operation of the Temperature and Pressure relief valve located at the top of the heater twisting the knob at the top of the valve. This lifts the valve seat and water will flow rapidly and be visible at the tundish.

Ensure the discharge pipe can cope with this flow rate continuously. Release the Temperature and Pressure relief valve. The flow should stop completely. Open the expansion relief valve and likewise check that water flows freely through the discharge pipe, that the discharge pipe can cope with the flow rate and that the water flow ceases when the valve is released. Switch on the electrical supply and select an appropriate heater setting on the thermostat knob (the thermostat is adjustable in the approximate range 20 C to 65 C. The neon indicator light comes on when the element is heating. 4. Operation This water heater will store water at a temperature selected via the thermostat on the front of the heater. To set the temperature turn the control clockwise to increase the temperature and anti-clockwise to decrease it. The indicator light comes on when the unit is heating. Maximum energy efficiency and product life is obtained avoiding very high temperature settings. The optimal temperature setting balances these factors. The maximum temperature settings is about 65 degrees, this can be excessively hot for some situations. In situations where very young children, the elderly or other vulnerable people are likely users a suitable thermostatic mixing valve should be fitted by your installer. If there is any risk of frost the heater should be left switched on at it lowest heat setting. If the heater is to be left unused for long periods, it should be drained. This unit should be maintained in accordance with the instruction in the sections 12-16. Never interfere with any safety valves. Beware that hot water discharged from safety valves could be very hot. 5. Maintenance Draining the unit To drain the unit disconnect electrical supply and close service valve on cold inlet. Open the drain cock on cold inlet and open a hot water outlet to enable air to replace draining water. Note that a small quantity of water will remain in the tank. This residual water can be drained by removing the heating element. Electrical components Always switch the electrical supply off before undertaking any maintence to the heater unit. Servicing of electrial parts should only be undertaken by competent individuals.

All maintainable electrical components are located under a plastic cover that is next to the inlet and outlet pipes and held in position with two small screws. Remove screws and lower cover to provide access to components. See diagram below for electrical parts identification. If replacing electrical parts take particular attention to ensure that the earthing connections (green/yellow) to the element flange and thermostat housing are sound. Thermal cut-out reset This unit contains a manually re-settable thermal cut-out that will switch the power off if the temperature reaches an abnormally high level. To reset the cut-out the press button as shown in Diagram 4. Diagram 4 Thermostat Thermal cutout - Press here to reset Element flange - Remove to access anode De-scaling procedure If scale is allowed to build up heater performance will suffer and the life of the product will be reduced. The effects of limescale are excluded from any warranty. To de-scale the heater, gain access to the element following the instructions set out in section 10. Remove thermostat and thermal cut-out bulbs from respective pockets and unscrew the 6 nuts holding the element flange in position. Withdraw element. Remove scale carefully. If necessary, dip element in a de-scaling solution available from DIY or plumbing outlets. Do not allow electrical connections to become wet. It is not normally necessary (or practical) to attempt to remove any scale from the tank walls. Refit element and follow commissioning instructions as per section 8.

Anode & tank inspection It is possible to view the tank by removing the element to gain access. It is advisable the tank is inspected at regular intervals for signs of corrosion. There is a magnesium anode fitted to most models of the Power flow. It is a grey magnesium cylinder fitted to the element base and its role is to reduce the rate of corrosion of the tank. It should be inspected periodically and replaced if there are signs of disintegration from a solid metallic structure. To access the anode, follow instructions in section 10. Remove scale carefully. If necessary, dip element in a de-scaling solution available from DIY or plumbing outlets. Do not allow electrical connections to become wet. It is not normally necessary (or practical) to attempt to remove any scale from the tank walls. Rest element and follow commissioning instructions as per section 8. Safety valve checks The Temperature and Pressure relief and expansion relief valve relieve any dangerous pressure or temperature build up that may arise as a consequence of abnormal operation. BOTH valves should be tested periodically by twisting the cap and checking that water flows freely. The water flow should cease when the valve is released. The pressure reducing valve contains a wire mesh gauze that may become clogged over time.to clean, close off mains water and open a hot outlet to drain the system of water. Unscrew the plastic top of the pressure reducing valve from the brass housing and remove complete mechanism including wire mesh. Rinse mesh to remove grit, scale etc as necessary and replace. Re-commission system following instructions as per section 8. Expansion vessel Water expands when it is heated.the expansion vessel accommodates expanded water during the heating cycle via a pressurised diaphragm arrangement so that water is not wasted. The vessel is supplied already pressurised to 3 bar.over time the pressure may be lost and water may be discharged during the heating cycle. The pressure should be checked using a standard car tyre foot pump or similar device. The pressure should be re-set to 3 bar.

6. Specifications Model PF30LC PF50LC PF90LC Maximum water pressure to pressure reducing valve 12 bar Power (kw)* 3.0 Voltage (V) Current (A) 230V ~ 50 Hz 13A Capacity (Litres) 30 50 90 Operating Pressure Maximum design pressure Expansion vessel charge pressure Expansion relief valve setting Pressure Reducing Valve setting Temperature and Pressure Relief Minimum recommended pressure 3 bar 6 bar 3 bar 6 bar 3 bar 7 Bar 90 degrees C 0.8 bar Immersion heater specification Hyco PFEL30 EN60335 x 1 Weight empty (kg) 9 13 24 Weight full (kg) 39 63 114 Heat up time (from 13 C to 60 C) in minutes 21 40 86 Reheat time (70% contents to 60 C) in minutes 16.5 28 57 Standing heat losses(kw/h) 0.93 1.16 1.26 Height (mm) 620 915 930 Width (mm) 380 380 540 Depth (mm) 295 295 385 Tank Material Inlet / Outlet Stainless steel ½ BSP male *Units also available with 1kW element. Add suffix of 1KW to product code e.g. PF30LC1KW

H W D

7. Troubleshooting Symptom Likely Fault(s) Remedy Water not heating Thermal cut-out needs re-setting Reset as section 11. Element failure Replace. Thermostat failure Replace. Thermal cut-out failure Replace. Electrical supply failure Check supply is present. Water too hot Thermostat set too high Reduce setting. Fit thermostatic mixing valve. Water milky coloured Dissolved gases coming out of solution No action needed. as they are heated this is normal Water will turn clear after condition for pressurised systems standing for a few seconds. Water discharged during Expansion vessel has lost its charge Re-pressurise vessel as heating cycle only section 15. Water discharged all the Either the pressure reducing valve is Replace appropriate valve. time failing to reduce the water pressure to 3 bar approx, or one of the safety valves is operating at below is nominal level. To differentiate measure the water pressure downstream of the pressure reducing valve. If the pressure is more than about 4 bar, replace the pressure reducing valve. If the pressure is less than 4 bar, replace the safety valve that is opening. No / limited water flow Check mains water is turned on. Check pressure reducing valve for grit. Mixing valves not working Unbalanced pressure. Ensure cold is tee-ed off correctly after pressure reducing valve so hot and cold are at equal pressure. 8. Guarantee and service policy This product is guaranteed against faulty materials and manufacture for a period of one year from the date of purchase. Hycowill in its sole discretion replace, repair or refund any faulty unit. Incorrect installation, frost damage, and the consequences of limescale deposits are excluded. Consequential costs such as labour charges or damage to fittings and surroundings are expressly excluded.

INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE 2002/96/E. At the end of its working life this equipment must not be disposed of as household waste. It must be taken to a local authority waste collection centre or to a dealer providing this service. Disposing of electrical and electronic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resources. In order to underline the duty to dispose of this equipment separately, the product is marked with a crossed out dustbin. Hyco Manufacturing Ltd Normandy Court Express Way Castleford, WF10 5NR T 01924 225 200 F 01924 225 210 E sales@hyco.co.uk hyco.co.uk