P R O D U C T D ATA S H E E T

Similar documents
P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

APPLICATION DATA SHEET

P R O D U C T D ATA S H E E T

APPLICATION DATA SHEET

IGD. O p e r a t i o n a n d M a i n t e n a n c e V International Gas Detectors. Triton House Crosby Street Stockport SK2 6SH England

IGD.CO.UK

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

P R O D U C T D ATA S H E E T

TOCSIN 750 SERIES OLIVER IGD. Triton House Crosby Street Stockport SK2 6TS England

APPLICATION DATA SHEET

2-WIRE SYSTEMS OLIVER IGD. 2-Wire. Version 3.2 T750-INST. Addressable. Triton House Crosby Street Stockport SK2 6SH England

CH4 SO2NO2. C O2 mount options. The controller has two SPCO relays as standard with three 4-20mA outputs and an RS485 Modbus UK Design And Manufacture

CH4 NO TOC-30A-AN1 TOC-30A-ANN TOC-30A-AN2 TOC-30A-AN3. Pepper Road Bramhall Technology Park Stockport SK7 5BW England. International Gas Detectors

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

GAS DETECTION International Gas Detectors CH4 NO

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch Modular Fire & Gas Detection System

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

YOUR PARTNER IN FIRE & GAS DETECTION

Touchpoint Pro Flexible Gas Control System

MULTIFUNCTIONAL SYSTEM

3M Oldham MX 43 Controller

Operating Instructions

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Detection, Protection, Innovation

Industrial Grade Gas Detection

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

Industrial Grade Gas Detection

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Danfoss gas detection units

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

BC3250. Blowdown Controller

LC1350 Level Controller

TOCSIN 700+ INSTALLATION AND USER INSTRUCTIONS

Recalibrate the way you look at gas detection

For Complete Fire and Gas Solutions

Danfoss gas detection unit Type GD Heavy Duty

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger QuadGard Control System

System 57. An advanced World of intelligent gas detection system management

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Products and performance

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Industrial Grade Gas Detection Detecting The Difference

Danfoss gas detection units

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Dräger Polytron 8200 Stationary gas detector (CatEx)

Gas Controller Module GC-06

Gasmonitor+ Installation, Operation and Maintenance Manual

Certification Supplement Manual

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Dependable Solutions for Gas Detection

Fire and Gas Monitoring Panel ST7-HV

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Wireless Fire & Security Solutions. Fire Product Showcase

GS100M Gas Detection Controller

Zareba Metro Gas Detector

Danfoss gas detection Controller unit

IECEx Certificate of Conform ity

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Certification Supplement Manual

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Vocia VACIE. Reference Guide

System 57. An advanced world of intelligent gas detection system management

5000 Series Rack Panels

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)

Software Version 2.01 LEVEL MONITOR MODEL 220

VACIE REFERENCE GUIDE REVISION 1.2.6

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Multi-Gas-Controller MGC2

Wireless Fire & Security Solutions. Fire Product Showcase

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

SGF 104 Oxygen Sensor

Solution F2. Fire Alarm Control Panels one step ahead.

Dräger REGARD -1 Control System

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Complete packages with Software and Controller

An introduction to... Sigma

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger REGARD -1 Control System

IntesisBox BACnet/IP Server - Notifier ID3000 series

Transcription:

P R O D U C T D ATA S H E E T www.internationalgasdetectors.com Transmitters Control Systems Sensors Accessories TOCSIN 90 Wall, 19 Rack or Panel Mounting Units 110/30V 50/60Hz AC operation 50 Addressable devices as: Relays, Analogue Inputs or Gas Detectors Latest Colour Touch Screen HMI Interface Integrate Other Signal Inputs One Man calibration Function Fully Accessible Modbus Interface Use as a Host Unit In Conjunction With Tocsin 640 or i700 Controllers WAV File Audible Alarms Flexible Alarm Options Attractive ABS Wall MountEnclosure Control up to 50 Addressable Gas Detectors The TOCSIN 90 offers the user the ability to control up to 50 addressable gas detectors or other devices. The TOCSIN 90 control panel is compatible with the TOCSIN 10, 103, TOC-30, TOC-0 and 903 Series of Toxic Flammable and Oxygen detectors and transmitters. The TOCSIN 90 can also be used as a host unit in conjunction with TOCSIN 640 and i700 series control panels. The system can control any addressable detectors or device. To compliment the system a range of accessories, calibration sets and audio visual alarms are available. Simple Integration to BMS or DCS Systems Single Man Calibration Functions Modbus Template for Integration With RDM Data Manager SK 6TS Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06 Ref: O 90-9

P R O D U C T D ATA S H E E T www.internationalgasdetectors.com Transmitters Control Systems Sensors Accessories EC Declaration of Conformity Issuers name and address: Oliver Limited of Crosby St,, United Kingdom Declares that the product listed as: TOCSIN 90 Addressable Gas Detection Control Panel Are in conformity with the provisions of the following European Directive(s) when installed, operated, serviced and maintained in accordance with the installation and operating instructions contained in the product documentation. 004/108/EC EMC Directive 006/95/EC Low Voltage Equipment Directive (note not applicable to 4V DC Powered Versions) And that the standards and/or technical specifications referenced below have been applied or considered. EN 61779-1:000 Electrical apparatus for the detection and measurement of flammable gases, general requirements and test methods. EN 5071:010 Electrical apparatus for the detection and measurement of combustible gases, toxic gases or Oxygen: requirements and tests for apparatus using software and or digital technologies. Excluding requirements for SIL EN 61000-6-: 005 EN 61000-6-4/A1: 011 EN 61000-3-: 014 EN 61000-3-3: 013 EMC Generic standards. Immunity for industrial environments EMC Generic standards. Emission standard for industrial environments EMC Limits. Limits for harmonic current emissions (equipment input current 16 A per phase) EMC Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current 16 A per phase Technical File Reference T90-TF9 Product Markings TOCSIN-90 Oliver Limited Operate and Independently assessed ATEX/IECEX QAN. Quality Assurance Certificate Number ExVeritas 16PQAN0014 Quality Assurance Notification Number: 585 ExVeritas, Units 16-18, Abenbury Way, Wrexham Industrial Estate, Wrexham, UK, LL13 9UZ S/-serial number Oliver Limited operate an independently assessed Testing Agency: ISO9001:008 Quality Management System. TUV - SUD Octagon House Concorde Way Quality Management Certificate Number PO 15 5RL FS 646773 Fareham BSI Assurance UK LTD, Chiswick High Road, London W4 4AL UK TUV Certificates and reports can be checked on-line at https://www.tuev-sued.de/industry_and_consumer_products/certificates Issued on: 0th Feb 016 At Oliver Limited,, SK 6TS, United Kingdom Signature: Declaration of Conformity in accordance with EN ISO/IEC 17050-1:010 Name Andrew J Collier M.I.O.D Position: Managing Director Date: SK 6TS 0th Feb 016 Declaration Ref: T90-DEC-6 Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06 Ref: O 90-9

TOCSIN 90 Specification Power Source Power Consumption Display Operating Temperature Operating Humidity Accuracy Resolution Update Rate Size (mm) Inputs Outputs (Standard) 110/30V AC 50/60Hz 150 Watts Base Unit (system dependant) Colour HMI 800x480 0 c to 55 c 5 to 95% non-condensing Sensor dependant 0.00% 0.00ppm Dependant on Sensor Type 1 Second 365 (H) x 533 (W) x 110 (D) Wall Mounting Version 3U High Rack Mounting Version Up to 8 x RS485 loops (Expandable Using Additional Hubs) 8 x configurable SPCO relays (7A non conductive load Expandable using Additional relay Cards) 1 x RS3/485 Comms Link (Modbus) Construction Injection Moulded ABS Enclosure IP54 Order Codes TOC-90-30 Tocsin 90 Wall Mount Base Unit 110/30V AC 50/60Hz TOC-90-4 Tocsin 90 Wall Mount Base Unit 4V DC TOC-90-KIT Tocsin 90 Kit (For OEM Integration) Comprises Panel Mount Display, Din Rail Hub and Din Rail Mount Relay Card With Cables 4V DC Operation TOC-90-3U Tocsin 90 19 Rack Mount Base Unit 110/30V AC 50/60Hz 590301 Modbus Option 590501 Addressable Relay Card 8 SPCO Relays For Use in Base Units 590601 Addressable RS485 Hub 8 RS485 Ports For Use in Base Units 590701 Addressable Relay Card 8 SPCO Relays DIN Rail Mounting 590801 Addressable RS485 Hub 8 RS485 Ports DIN Rail Mounting 590901 Field Box. Field wall mounting enclosure to accommodate two cards, as either relays or hubs TOC-750-BAT1 Battery Backup Module 7AH (Use with 4V DC Panel TOC-90-4) TOC-750-BAT Battery Backup Module 17AH (Use with 4V DC Panel TOC-90-4) 591101 DIN Rail Mount 4V DC PSU Module 110/30V AC 50/60Hz SK 6TS Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06 Ref: O 90-9

TOCSIN 90 RDM Interface, LAN RS3/485 Comms Link To Host Systems, SCADA, BMS etc via MODBUS or similar 8 Volt Free Relay Contact Outputs As Standard Expandable Audio Visual Units Available Relay Output Nodes For Local Alarm or Control Up to 3 Detectors Flammable or Toxic Gases Per Loop 110/30 VAC 0r 4V DC Power Options Compatible With Tocsin 103, 10, TOC-30 or 903 Series Detectors. Battery Back Up Units Available Connect RS485 Ports to Act as a Host For Tocsin 640 or i700 Series Control Panels. See the Same Detectors Connected to The Tocsin 640 or i700 on The Tocsin 90 8 off RS485 Ports. Use as Either Double Ended (Looped Back) or Single Ended Cable Runs Any Mix of Detectors, Flammable, Toxic, Oxygen and Relay Outputs Power Boosters To Cater For Long Cable Runs ATEX or Safe Area Detectors SK 6TS Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06 Ref: O 90-9

TOCSIN 90 Typical system Block Diagram Typical Screen Shot, Tocsin 90 Series HMI Display. Touch Screen 60,000 Colours, 800 x 480, 7 Display. Base Systems Comprise: Touch Screen HMI Panel 150W PSU One Data Highway Hub One Addressable Relay Output Card. Tocsin 90 Series Control Panel 4 Core Cable Highway Data Highway Hub. 8 Ports Serving Up To 3 Devices Up to 3 Addressable Detectors, Relay Output Nodes, Cards or Signal Input Nodes Per Data Highway Note the Maximum Number of System Devices Per Tocsin 90 is 50 8 Port Hubs and Relay Cards can bechassis or DIN Rail Mounting for inclusion into OEM cabinets. All Devices are 4V DC Powered. Field boxes are available for in field installation of Hubs and relay cards if required. 8 Output Addressable Relay Card SK 6TS 8 Output Addressable Relay Card Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06 Ref: O 90-9

TOCSIN 90 19" Rack Mount Option 483.0 133.4 (3U) 44.45 (1U) 80.0 Wall Mount Option 360mm 10 off 0mm Cable Entries 56.5mm 30mm 0mm 48.5mm Top Face FRONT VIEW 10.5mm 38mm 7mm Front Face 134mm 9mm Side Face Installation Cables Supported Installation Cables Core 1.5mmSQ or.5mmsq See Cable System Calculator Typically SWA, MICC, FP00, SY, CY, or Similar screened cable SK 6TS Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06 Ref: O 90-9

TOCSIN 90 Detector Control Upgrade System for Existing Users Two Trays Per Tocsin 90 Highway Port. 16 Pellistor Flammable Gas Detection Channels Per Rack Tray 4V DC Supply Active Common Compensator P Y W Interfaces to Existing mv Mk3 Pellistors Using Existing Wiring 19" Rack Mount Controller 483.0 133.4 (3U) 44.45 (1U) Tocsin 90 Rack mount Units Are Standard 19 Rack Modules 3U High (133.35mm) 80.0 All electrical Terminations are to the Rear of the Rack SK 6TS Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06 Ref: O 90-9

TOCSIN 90 DIN Rail Mounted Highway Hub Dimensions DIN Rail Mounted Relay Card Dimensions SK 6TS Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06 Ref: O 90-9

TOCSIN 90 System Example LPG 0-100%LEL GAS DETECTOR SN:035-1-1 ADD:4110 Use Annunciators For Door Entry Control. Use Annunciators with Gas Detector Interfaces to Detect & Alarm in Specific Areas Controller in Supervisors Office Laboratory Mix Annunciators With Other Addressable Devices Such as 10 or TOC-30 Series Detectors. Use ATEX Rated detectors where required LPG 0-100%LEL GAS DETECTOR SN:035-1-1 ADD:4110 Gas Bottle Store 4 Core Highway as: 4V,A,B, 0V Typically 1.5mmSQ Screened Cable Use the Annunciator I/O Capability combined with a MK7 Pellistor to Control Gas Supply Valves, BeaconSounders or other devices ATEX Zoned Area SK 6TS Fax: +44 (0) 161 484 345 REF T10-LPG-3R-V1.06 Ref: O 90-9