Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Similar documents
Effects of Refrigerant-Lubricant Combinations on the Energy Efficiency of a Convertible Split-System Residential Air-Conditioner

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Study of R161 Refrigerant for Residential Airconditioning

Low GWP Refrigerants for Air Conditioning Applications

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

R-404A Alternative with Low Compressor Discharge Temperature

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Low Global Warming Refrigerants For Commercial Refrigeration Systems

R-407A R-448A R-449A

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Development of HFC-134a Compressor for Domestic Refrigerator

Oil Return Measurements In A Unitary Split System Air Conditioner Using Different Refrigerant Mixtures

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

Performance Measurement of R32 Vapor Injection Heat Pump System

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Test Results from the AHRI Low GWP AREP II (Alternative Refrigerant Evaluation Program) Transport Refrigeration

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Tribology Characteristics of HFO and HC Refrigerants with Immiscible Oils - Effect of Refrigerant with Unsaturated Bond -

R32 Compressor for Air conditioning and Refrigeration applications in China

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

High Efficiency R-134a Compressor for Domestic Refrigerator

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit

Efficiency of Non-Azeotropic Refrigerant Cycle

A Performance-Enhancing Additive for Vapor- Compression Heat Pumps: Additional Test Results

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Chapter 2. Alternatives to HCFCs and their Characteristics

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Behavior of R410A Low GWP Alternative Refrigerants DR-55, DR-5A, and R32 in the Components of a 4-RT RTU

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Sub-Critical Operation of the CO2 Expander/ Compressor

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Purdue e-pubs. Purdue University. T. Hamada Mitsubishi Heavy Industries Ltd. N. Nishiura Mitsubishi Heavy Industries Ltd.

Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Seminar 34 Refrigerants Today, Tomorrow, and Beyond

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Conversion of platelet incubator refrigeration system to R600a and performance optimization

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Purdue e-pubs. Purdue University

Selection of a refrigeration oil for the R32 refrigerant and evaluation of the compressor reliability

Extremely Low Refrigerant Charge Beverage Display Cooler Technology Using Propane

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Evaluation and Development of Air-conditioners using Low GWP Refrigerant

Compressor Durability Tests and System Tests with AB and HFCs

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

A fair comparison of CO2 and propane used in light commercial applications featuring natural refrigerants

An Experimental Investigation on Flow Characteristics of Refrigeration/Oil Mixture in Vertical Upward Flow

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Performance of CO2 Cycles with a Two-Stage Compressor

A study on retrofit methodologies for legacy air-conditioning systems to reduce their impact on global warming and ozone depletion

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

PRACTICAL EXPERIENCE WITH AN ALTERNATIVE TO R-22 BASED ON R-32lR /R a. R E Low, B E Gilbert, T W Dekleva.

Refrigerant Glide and Effect on Performances Declaration

A2L Refrigerants Leaks and Ignitions Testing under Whole Room Scale

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Dynamic Simulation of Liquid Chillers

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

DEEPAK PALIWAL, S.P.S.RAJPUT

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Refrigerant Mass and Oil Migration During Start-up Transient

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Air-Cooled Heat Exchanger Performance for R410A

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

Exploring the Performance Characteristics of CO2 Cycles in a Breadboard-Type Test Facility

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants Edward Hessell Industrial Performance Products Division, Chemtura Corporation, United States of America, ed.hessell@chemtura.com Roberto Urrego Industrial Performance Products Division, Chemtura Corporation, United States of America, roberto.urrego@chemtura.com Follow this and additional works at: http://docs.lib.purdue.edu/iracc Hessell, Edward and Urrego, Roberto, "Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants" (2016). International Refrigeration and Air Conditioning Conference. Paper 1679. http://docs.lib.purdue.edu/iracc/1679 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

2274, Page 1 Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants Edward HESSELL*, Roberto URREGO Industrial Performance Products Division, Chemtura Corporation 400 Elm Street, Naugatuck, CT Phone: 203-714-8674, Email: Ed.Hessell@Chemtura.com * Corresponding Author ABSTRACT This paper extends our previous investigations of refrigerant/lubricant property optimization to refrigerant blends; in particular, to nonflammable low global warming potential replacements for R-404A (GWP= 3952) with GWP < 1500. Solution phase behavior and solution property data are reported for R-449A/B and R-448A in combination with three POE lubricants of varied chemical structure, and corresponding varied solubility/miscibility with the refrigerant. When comparing refrigerant blends with a single lubricant, R-449A/B and R-448A gave a lower isobaric suction condition viscosity curve than R-404A; suggesting that these new refrigerant blends may give improved compressor energy efficiency at low operating temperatures. The results suggest that, although each polyol ester lubricant exhibits very different miscibility behavior in the refrigerant blends, the resulting solution viscosities at normal operating conditions is nearly identical for the isobaric suction curves. However, there were differences observed in the solution viscosities in the isobaric discharge condition curves. The overall conclusion is that there may be opportunities to improve frictional and wear performance through optimization of lubricant properties depending on compressor design and operating conditions. All three refrigerant blends can use the ISO 32 POE lubricants currently in use with R-404A without any detriment to performance or reliability. 1. INTRODUCTION Lubricants are important components of almost all air conditioning and refrigeration systems. Their primary function is to lubricate the compressor, provide sealing of clearances between low and high pressure sides of the compressor and remove frictional heat. But the lubricant is in contact with refrigerant at all times in the refrigeration cycle and plays a thermo-fluidic role that can impact both system capacity and coefficient of performance (COP). Lubricants can influence capacity by altering the refrigerant-side heat transfer coefficients, and increasing pressure drop required to maintain set point temperatures. Lubricants can also affect the isentropic efficiency of the compressor. Recent research has conclusively demonstrated that the optimization of lubricant/refrigerant properties can provide improvements in energy efficiency and COP (Benanti, 2014). The transition to lower global warming potential (GWP) alternative refrigerants is critical to the realization of environmentally sustainable and more energy efficient refrigeration technologies (Ritter, 2013). Leading candidates to replace R-404A (GWP= 3922) include refrigerant blends R-448A and R-449A/B; having GWP in the range of 1250-1400 [IPCC AR4]. 2. EXPERIMENTAL 2.1 Refrigerant/Lubricant Miscibility Measurements Glass tubes were charged with predetermined volumes of lubricant having a moisture content of less than 25 ppm. The tubes were then attached to a gas manifold of known volume and evacuated to < 13 Pa. The tubes were then cooled using liquid nitrogen and individually charged with predetermined amounts of refrigerant using pressure change to accurately control the amount of refrigerant added. Each tube was then flame sealed and slowly warmed to room temperature. The total volume of lubricant/refrigerant in each tube was fixed at 2.0 ml regardless of the

2274, Page 2 concentration of lubricant in refrigerant. The tubes were then secured in a computer controlled temperature chamber quipped with a video camera. The chamber temperature was then changed at a controlled rate of 0.1 C per minute while the video camera recorded any changes in the phase behavior of the refrigerant/lubricant mixtures in the tubes. The temperature change was always made starting at room temperature and either going up or down in temperature until the first signs of incompatibility (cloudiness) was observed. Both upper and lower critical solution temperatures were taken as the first point when a haze was observed. Measurements were conducted in the temperature range of -60 to 70 C. 2.2 Refrigerant/Lubricant Thermophysical Data Measurements Solution properties as a function of Pressure, Viscosity, and Temperature (PVT) were determined using the test equipment described by Seeton (2009) to collect data to obtain constants for the set of solubility, density, and viscosity refrigerant/oil equations (Seeton and Hrnjak, 2006). The PVT test equipment is illustrated in Figure 1. The construction provides a circulation loop to maintain thermodynamic equilibrium during a slow temperature ramp. A pump circulates the fluid and promotes mixing; a mass flow meter measures rate flow, temperature, and density of the fluid; a piston viscometer measures temperature and viscosity; thermocouples measure bulk liquid phase and vapor phase temperature; and a pressure transducer measures system pressure. The loop is placed inside a thermal chamber that maintains constant temperature or a ramp temperature small enough to maintain a thermodynamic equilibrium when it sweeps a range of temperature at a constant bulk composition (Seeton, 2009). A desktop computer records the set of properties for each run for regression analysis. Figure 1: PVT Test Equipment 3. RESULTS AND DISCUSSION 3.1 Refrigerants of the Study The compositions of the refrigerant blends of the study are shown in Table 1. The compositions of R-449A and R- 449B are essentially the same and so for the purposes of this paper they will be considered together with the designation R-449A/B. 3.2 Polyol Ester Lubricants of the Study All three polyol ester (POE) lubricants of the study were ISO 32 viscosity grade. The primary difference in the lubricants was their relative compatibility with the refrigerants. The miscibility of lubricants divided into three basic categories; fully miscible, partially miscible and non-miscible. Fully miscible lubricants are defined as those that remain as a single phase with the refrigerant of interest over the entire range of relative mixing ratios within the temperature range of -60 C to +70 C. Non-miscible lubricants are those that form a separate phase from the refrigerant of interest over the entire range of mixing ratios within the temperature range of -60 C to + 70C. Partially

2274, Page 3 miscible lubricants are those that show a mixture of single phase and 2-phase behavior as a function of temperature and relative mixing ratios. The latter are the most prevalent type of lubricants used today with HFC refrigerants. The predominant commercial ISO 32 lubricant used today with R-404A is fully miscible. Table 1: Refrigerant Blend Compositions of the Study Refrigerant R-404A R-448A R-449A R-449B Component R-125 44.0 26.0 24.7 24.3 R-134a 4.0 21.0 25.7 27.3 R-143a 52.0 R-32 26.0 24.3 25.2 R-1234yf 20.0 25.3 23.2 R-1234ze 7.0 Table 2: Physical Properties of the POE Lubricants of the Study Lubricant POE 1 POE 2 POE 3 KV @ 40 C 31 31 30 KV @ 100 C 5.3 5.6 5.6 Viscosity Index 129 135 145 Density (Kg/L) 0.998 0.970 0.967 Pour Point ( C) -60-45 -26 Flash Point ( C) 270 266 266 Refrigerant Miscibility R-404A Fully Miscible Partially Miscible Not Miscible R-448A Fully Miscible Partially Miscible Not Miscible R-449A/B Fully Miscible Partially Miscible Not Miscible 3.3 Miscibility of the Lubricants in Refrigerants Lubricants generally fall into one of three categories with regards to miscibility with refrigerants as illustrated in Figure 2. It should be noted that although the Not Miscible category still contains a single phase region, this region is only at very high lubricant to refrigerant ratios where the lubricant dominates the cohesive properties of the mixture. Any lubricant/refrigerant combination that is completely immiscible at all temperatures below a lubricant/refrigerant ratio of 1:1 is, in all practicality, Not Miscible. The majority of POE lubricant/hfc refrigerant mixtures used commercially today would fall into the Partially Miscible category. However, for refrigerants like R-404A used in low temperature applications, the desire is to have miscibility (single phase behavior of the mixture) that extends below -40 C. Thus, most POE s are fully miscible with R-404A. The miscibility of each lubricant, having varied polarity properties, was evaluated in each of the three lower GWP refrigerants and compared to that of R-404A. The results indicate that each of the low GWP refrigerant blends has relatively similar miscibility to R-404A (see Table 1). 3.4 Conditions for Reporting Solution Viscosities The ranges for reporting the solution viscosities of various combinations of lubricant and refrigerants are taken from actual measurements of suction and discharge temperatures taken from full system tests (Abbas, 2016). Although measurements were taken for a total of nine different conditions (Table 3), for the purposes of this paper, data will only be reported for one set of conditions (setting number 7). This one condition was taken as representative of a low temperature cooler in a modern grocery store. But it should be noted that the subsequent analysis presented in this paper for this one condition can equally be applied to the other sets of testing conditions.

2274, Page 4 Fully Miscible Partially Miscible Not Miscible Figure 2: General Categories of Miscibility Between Lubricants and Refrigerants Table 3: Ambient Temperature and Evaporator Settings for Calorimeter Measurements Setting Number Ambient Temperature ( C) 1 15.5-9.4 2 29.4-9.4 3 40.5-9.4 4 15.5-17.8 5 29.4-17.8 6 40.5-17.8 7 15.5-28.9 8 29.4-28.9 9 40.5-28.9 Evaporator Temperature ( C)

2274, Page 5 The suction/discharge temperatures and pressures for each combination of refrigerant and lubricant are reported in Table 4. The combination of R-404A with POE1 is included as a reference as this refrigerant/lubricant combination is used commercially today. Experimentally temperatures and pressures were not available for R-448A/POE 1 combination, however, values were estimated by simply averaging the suction and discharge temperatures and pressures from R-449A/B experimental data. This was considered valid based on the near equivalence of the critical temperatures, pressures and densities of R-448A and R-449A/B. Table 4: Suction/Discharge Temperatures and Pressures Refrigerant R-404A R-449A/B R-449A/B R-449A/B R-448A Lubricant POE 1 POE 1 POE 2 POE 3 POE 1 Suction Temp. ( C) -9.5-4.4-11.4-7.0-7.6* Discharge Temp ( C) 44.7 54.8 54.3 55.1 54.7* Suction Pressure (KPa) 169 147 144 140 144* Discharge Pressure (KPa) 1579 1576 1567 1560 1568* *Estimated as described in text. 3.5 Variation in Solution Viscosity as a Function of Refrigerant Composition The solution viscosity of a single ISO 32 POE (POE 1) was compared under both suction and discharge conditions for the low GWP alternatives R-448A and R-449A/B vs. R-404A as control. The viscosity under suction conditions is very representative of the viscosity of the liquid lubricant/refrigerant in the sump of a compressor. At suction, the solution viscosity of both low GWP alternatives R-448A and R-449A/B are essentially identical over the temperature range of -12 C to 55 C (Figure 3). The viscosities are always lower than that of R-404A, suggesting higher solubility of these refrigerants in POE 1 at low temperatures and pressures. But the absolute viscosity is always in the range of 30-150 cst which would be anticipated to be acceptable for proper lubrication of bearings in the sump of a reciprocating compressors. The difference in the viscosities between R-404A and the alternatives also disappears as the temperature increases. This effect is due to the fact that refrigerant is driven from the lubricant as the temperature increases so the observed viscosity becomes a function of the lubricant alone at low pressure. The solution viscosity as a function of temperature for the discharge conditions are shown in Figure 4. The isobaric discharge viscosity lines are representative of the viscosity of the liquid refrigerant/lubricant mixture as it leaves the discharge port. Note that the viscosities are much lower than the corresponding suction viscosities (Figure 3). The discharge liquid contains a high concentration of refrigerant. Because this liquid has no practical role in lubricating important moving parts of a typical reciprocating compressor, there is no concern that such viscosities are so low But there might be implications for scroll compressors where lubrication and sealing are required over the entire range of temperature/pressure from suction to discharge. 3.7 Variation in Solution Viscosity as a Function of Lubricant Type POEs with varying degrees of miscibility with the low GWP refrigerants were compared in a single refrigerant (R- 449B). The suction condition viscosity curves are shown in Figure 5. For all cases, the solution viscosities were virtually identical, despite significant differences in compatibility of the POEs with R-449B. This is somewhat surprising, but also highlights the fact that, regardless of the observed miscibility behavior, all of the lubricants have similar solubility with R-449B at very high lubricant:refrigerant ratios. The solution viscosity curves for three different lubricants of different compatibility with R-449B are shown in Figure 6. Here, where the concentration of refrigerant is high and the viscosity is low, there is a trend in observed viscosity as a function of the compatibility/solubility of the lubricant with the refrigerant. The non-miscible lubricant (POE 3) gives the highest viscosity curve while the fully miscible lubricant (POE 1) gives the lowest viscosity curve. Regardless, the differences are small.

2274, Page 6 Figure 3: Suction Condition Solution Viscosity Curves for Three Refrigerants with a Single Lubricant Figure 4: Discharge Condition Solution Viscosity Curves for Three Refrigerants with a Single Lubricant

2274, Page 7 Figure 5: Suction Condition Solution Viscosity Curves for Three Lubricants with a Single Refrigerant (R- 404A/POE 1 shown as reference) Figure 6: Discharge Condition Solution Viscosity Curves for Three Lubricants with a Single Refrigerant (R- 404A/POE 1 shown as reference)

2274, Page 8 4. CONCLUSIONS The solution properties of three ISO 32 POE lubricants of different miscibility/compatibility with several low GWP R-404A replacement refrigerant blends was studied. Comparison of suction and discharge isobaric viscosity curves for a single ISO 32 POE with all three refrigerants shows that all of the low GWP replacements have similar viscosity profiles to that of R-404A. This not surprising in that it is likely that a design criteria for all of the blends was near equivalent miscibility and solubility behavior with currently used commercial ISO 32 POE lubricants. Comparison of the suction and discharge solution viscosity curves for three different lubricants with one low GWP refrigerant (R-449B) shows very little difference in solution properties despite the large variation in the solubility/miscibility properties of the ISO 32 POEs. The overall conclusion of this study is that the current commercial ISO 32 lubricants used today with R-404A can also be safely used with low GWP replacement refrigerants R-449A/B and R-448A. There is no reason to believe that there will be any lubricant related issues with system performance and/or equipment reliability. 5. NOMENCLATURE AHRI Air-Conditioner Heating and Refrigeration Institute ( ) AREP Alternate Refrigerant Evaluation Program ( ) ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers ( ) ASTM American Society for Testing and Materials ( ) C Degrees Celsius ( ) cst Centistokes (viscosity) (millimeter/second 2 ) GWP Global Warming Potential ( ) HCFC Hydrochlorofluorocarbon ( ) HFC Hydrofluorocarbon ( ) HFO Hydrofluoro-olefin ( ) KV Kinematic Viscosity, Centistokes (millimeter/second 2 ) POE Polyol Ester ( ) ppm parts per million (milligram/liter) kpa kilopascals (killogram/meter second 2 ) PVT Pressure-Viscosity-Temperature (kpa-cst- degrees centigrade) REFERENCES Abbas, L., Kim, S., Hessell, E., Urrego, R., 2016, System Energy Efficiency Performance of New Low GWP Replacements for R-404A as a Function of Lubricant Structure and Refrigerant/Lubricant Properties in a Commercial Refrigeration Unit, ASHRAE Winter Conference, Seminar 16-1. Benanti, T., Hessell, E., Urrego, R., Wujek, S., Bowers, C., Elbel, S., 2014, Effects of Refrigerant-Lubricant Combinations on the Energy Efficiency of a Convertible Split-System Residential Air Conditioner, 15 th International Refrigeration and Air-Conditioning Conference, Purdue University, Section R-27: Refrigerant and Lubricant Design and Analysis I, paper 2499. IPPC AR4, 2007, Fourth Assessment Report of the Intergovernmental Panel on Climate Change, https://www.ipcc.ch/report/ar4/. Ritter, M., 2013, Domestic and International Policy for HFCs and Next Generation Refrigerants, ASHRAE 2013 Summer Conference, Denver, CO, Seminar 23, Paper 10469. Seeton, C. J. and Hrnjak, P., 2006, Thermophysical Properties of CO2-Lubricant Mixtures and Their Affect on 2- Phase Flow in Small Channels (Less than 1mm), International Refrigeration and Air Conditioning Conference, Paper 774.

2274, Page 9 Seeton, C. J., 2009, CO 2 -Lubricant Two-Phase Flow Patterns in Small Horizontal Wetted Wall Channels, the Effects of Refrigerant/Lubricant Thermophysical Properties, University of Illinois, Urbana-Champagne, IL ACKNOWLEDGEMENT The authors would like to thank Dr. Laurent Abbas and Dr. Sarah Kim of Arkema for their helpful discussions during the preparation of this manuscript as well as for kindly providing the system test conditions that allowed the generation of application specific solution viscosity data.