Interfacing with the ADAM Module

Similar documents
Added password for IP setup page : Password must be in IP format!

Avigilon Control Center System Integration Guide

Moxa Proactive Monitoring User s Manual

System Galaxy Quick Guide

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Configuration and Operation Manual for the Unipos

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

AxxonSoft. Operation Manual TROMBONE. Fire and Security Alarm Integration Module. Version 1.1. Moscow

ThermoControl 0 C - 10 C - 20 C - 30 C

Ademco Vista Alarm Panel

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

FlexZone SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE HOW-TO GUIDE

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Innovative protection that combines power and flexibility

Avigilon Control Center System Integration Guide

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Avigilon Control Center System Integration Guide

N-8000 SERIES IP INTERCOM SYSTEM

Access CONTROL. MANAGEMENT Software

Advisor Advanced Mobile Application User Manual

Architectural and Engineering Specification for a Security Management System. StarNet 2

ONYXWORKS AND FIRSTVISION. Version 4

GLOBAL. InstallatIon & operation manual

Recording Server PRELOADED

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

Security Management System Configuring TCP-IP MODBUS Inputs

[ [ ADMIN PANEL USER GUIDE

rvm4c Installation Guide Remote Video Module

D-TECT 3 IP. GJD260 IP Motion Detector

Network Hardware and wiring (quiz)...

Manage Alarms. Before You Begin CHAPTER

D-TECT 2 IP. GJD230 IP Motion Detector

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link -

IndigoVision Alarm Panel. User Guide

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

E3 Series Broadband System

Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

Alarm annunciation, control and communication systems

Avigilon Control Center System Integration Guide

Advanced FireAlarm Panel 1-4Loop

WiFi GSM APP Smart Home Security System

Multi-layered Perimeter Protection Systems Quality detection systems for high security sites

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Manage Alarms. Before You Begin CHAPTER

RLS-3060SH REDSCAN ULTIMATE

T a b l e o f C o n t e n t s

E3 Series Broadband System

Quick start guide. English

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

Model 4880 Status Output Display Module Manual

User Manual. Dryer Controller M720

AK SM 800 Commissioning Guide

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

INSTALLATION INSTRUCTIONS

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Consultant Specification AGILE Wireless Fire Detection System

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

LightSweep. Lighting Control System

USER S GUIDE. AXIS Cross Line Detection

Panel Remote Annunciators Installation Instructions

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

How to use the BTRM in Remote Enclosures

Intelligent Fire Detection & Alarm and Mass Notification System.

Dryer Controller M720

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

Maxline 2 Thermal Imaging Solutions for Manufacturing

Synergis Master Controller 2.2 Integration Guide for Assa Abloy IP Locks

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

CX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

Perimeter Product Overview. Effective protection for your business

Fiber Optic Cable Fence Disturbance Sensor

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

HikCentral Web Client. User Manual

VMD Guide for V960 Series Cameras

HD COMMUNICATOR. Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair.

Contents. What is Paxton10? 3. How does it work? 4. Paxton10 hardware 5. Paxton10 software 8. Paxton10 portal 9. Useful information 10

Ethernet General Purpose

UNC100 Integra Manual

Welcome to MultiSight TM Vision Sensor Hands-On Lab

USER MANUAL FOR OPERATING SYSTEM

Avigilon Control Center 5 System Integration Guide

Patriot Systems Limited

MILAN VORTEX WIRELESS MOTION SENSOR USER MANUAL

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Integrated Security Solutions

Avigilon Control Center 5 System Integration Guide

For Complete Fire and Gas Solutions

YachtSafe GPS Alarm Manual

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

SMS GSM Alarm Messenger

Fire Operator Workstation (Fire OWS) User s Guide

Architectural and Engineering Specification for a. Flash / Flare

Transcription:

Introduction Interfacing with the ADAM Module Fiber SenSys, Inc. (FSI) has goal to provide our customers with the best security solution available to fulfill their project requirements. Our design and engineering teams strive to build products that integrate well with other devices in the safety and security landscape. With product versatility and flexibility in mind, FSI provides a customizable and dynamic integrated perimeter security technology solution to address installation challenges located around the globe. We fulfill our customer s security and safety requirements both by offering a diverse group of products and by developing synergistic relationships with partner organizations. Fiber SenSys has identified the ADAM-6060 input/output (I/O) module (Picture 1) as an extremely reliable and useful tool for the integration of our products - both with each other and with the security solutions provided by our industry partners. The purpose of this document is to outline the process of using the ADAM I/O module to create a comprehensive, integrated security solution. Picture 1: The ADAM-6060 Module

The ADAM-6060 is an Ethernet-based data acquisition and control module that provides I/O, data acquisition and networking in one module to build a cost-effective, distributed monitoring and control solution for a wide variety of industries and applications. Through de-factor standard Ethernet networking, ADAM-6060 retrieves I/O values from sensors and publishes real-time I/O values to networking nodes at local area network or Intranet / Internet devices and software. With Ethernet-enabled technology, the ADAM-6060 module is a significant security systems integration tool. Communications in traditional security systems are typically facilitated through Form C dry contacts, where the alarm condition of an Alarm Processor Unit (APU) is communicated via twisted pair to industry-standard head end or annunciator panels. Fiber SenSys has developed Fiber Commander as a head end system to enable command and control of multiple devices in an integrated security solution. With the use of the ADAM-6060, the use of wire is converted to IP and as a result, many security system devices are integrated and communicate with each other (Picture 2). Please note that Fiber Commander is used in this example, but it is important to note that any industry-standard head end that accepts the same type of connectivity will provide the same security systems design and architecture functionality. Picture 2: The ADAM Module and Fiber Commander Head End Software, connected to multiple devices

Initial Setup Step-by-step guidelines for connecting and interfacing the ADAM-6060 module with our lightweight head end software are outlined in the Fiber Commander User Guide, which can be downloaded from http://www.fibersensys.com/. The ADAM configuration software for free at its support portal located here: http://support.advantech.com.tw/support/downloadsrdetail_new.aspx?sr_id=1-2akudb&doc_source=download. The ADAM software package is entitled ADAM/APAX.NET Utility. Please refer to the Configuring ADAM 6060 Devices for use with Fiber Commander in the Fiber Commander manual for a detailed process of setting the device IP address, setting the port number, changing the device name, and updating the communications settings. Setting Up Third Party Sensors or Inputs Once the ADAM s IP address has been altered to exist within the same subnet as the host computer, the next step is to configure the device to receive alarm signals into its input relays and/or to output a signal when the desired conditions are met. The ADAM 6060 device can support up to six inputs and the enabled ports can be chosen from the Advantech ADAM/APAX.NET Utility by selecting the device, choosing the Peer to Peer/Event tab, and checking the Modify channel enable checkbox (Picture 3). Bear in mind, a numeric mismatch exists between the ADAM utility and Fiber Commander the Advantech enumerates its ports beginning with 0 while Fiber Commander begins with 1. Picture 3: Observe there are two inputs enabled; use the [Apply list] button to activate these changes.

Next, open the Fiber Commander software, select the Configuration window from the Options menu and select the ADAM tab. Use the [Scan Network] button to locate the ADAM device in the network and select the [Add] button to attach it to the secured network. Observe in the screenshot below that there are only two editable zones in the Alarm Trigger Level frame. Determine if they should be active high or active low by checking or unchecking the Zone checkboxes. Active low will trigger when the relay is grounded. GND port and active high will trigger when the grounded relay is disconnected from the Iso GND port. In the screenshot below, the Zone 1 alarm will activate when the DI0 port connects to the Iso. GND terminal and the Zone 2 alarm will activate when the DI1 port disconnects from the Iso. GND terminal. The Zone 1 case is configured for a Normally Open (NO) third party sensor and the Zone 2 case is configured for a Normally Closed (NC) third party sensor. Picture 4: Observe adding Normally Open and Normally Closed inputs to the ADAM I/O module Configuring the ADAM-6060 Output Relays The purpose of the output relays is to activate alarm handling equipment when a zone enters into an alarm state. Examples of alarm handling equipment include audible alarms, Light Defender visual deterrents, camera presets, and third party alarm panels.

To activate an output relay, open the Fiber Commander software, right click the alarm that will act as a trigger and select output mapping. A window will open that displays the 6 output ports; select the desired port, give it a name in the IO Mapping Name field, select the desired trigger, and select the [Update] button. The most common trigger is the ALARMED dropdown option, but users may also choose to alarm during communications failures, faults, tamper alarms, or when the input becomes secure. The user may also choose a Hold Time, which holds the output in the changed state for a user defined amount of time. The versatile ADAM-6060 supports six dual output relays that can be either NO or NC based on user preference using the Closed when Active checkbox. Conclusion Meeting the diverse needs of a worldwide customer base is Fiber SenSys first priority. With the addition of 3 rd party proven and tested components, such as the ADAM-6060, we are poised to offer outstanding hardware and software to interface reliably and easily with FSI s other security products. Fiber Commander Software by Fiber SenSys offers an easy to configure, inexpensive, and highly secure method for interfacing with ADAM-6060 modules and many other third party devices. The ADAM product line is well known in the safety and security industry and adds value to our sensors resulting in a more comprehensive safety and security solution. For more information, contact us: info@fibersensys.com Tel: +1(503)692-4430 Toll free (US) +1(888)736-7971 www.fibersensys.com High Performance - High Reliability - High Security Fiber SenSys and Fiber SenSys logos are trademarks of Fiber SenSys, Inc. PI-SM-511 Rev A. 6-13