P125 High Pressure Sensor

Similar documents
DP86 Constant Voltage with Fitting

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

MSP340 Pressure Transducer

MSP100 Pressure Transducer

D5100 Industrial Differential Pressure Transducer

86BSD Digital Output

89BSD Digital Output

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

M7100 Pressure Transducer

D5100 Industrial Differential Pressure Transducer

ELAF LOAD CELL SPECIFICATIONS FEATURES

Sub psi SPECIFICATIONS

86BSD Digital Output

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Standard SPECIFICATIONS FEATURES APPLICATIONS

FC22 Compression Load Cell

M5800 Pressure Transducer with Rotatable Display

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

MSP300 Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

FC23 Compression Load Cell

M5200 Industrial Pressure Transducer

M5800 Pressure Transducer with Rotatable Display

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

MSP100 Pressure Transducer

MODEL 4000A & 4001A ACCELEROMETER

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

MODEL 834M1 ACCELEROMETER

The Importance of Pressure Sensors in HVACR Systems

U5700 Submersible Liquid Level Pressure Transducer

Cable Actuated Sensor Industrial Incremental Encoder Output

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

LOW PRESSURE Intrinsically Safe Transducer AST44LP

86BSD Digital Output

PT9420 (Extended Range)

U5300 Industrial Pressure Transducer

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

MS4525 SPECIFICATIONS

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

PT9600. Cable Actuated Encoder Reel. General. Environmental

CABLES AND ACCESSORIES FOR TRUBLUE DATA LOGGERS

OPERATION MANUAL MODEL & ACCELEROMETER

Cable Actuated Sensor Industrial User Scalable VDC Output

Cable Actuated Sensor Industrial User Scalable 4 20mA

PT9150 (Extended Range)

OPERATION MANUAL MODEL 4610 ACCELEROMETER

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

OPERATION MANUAL MODEL 805 ACCELEROMETER

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

U5600. Wireless Pressure Transducer SPECIFICATIONS

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

MODEL ACCELEROMETER

OPERATION MANUAL Model 8011 & mA

LMM-H03 Mass Air FLow Sensor

MEAS EMITTER ASSEMBLY ELM-4000 SERIES

LMM-H04 Mass Air FLow Sensor

HM1520LF Relative Humidity Module

OPERATION MANUAL MODEL 8102 ACCELEROMETER

HM1500LF Relative Humidity Module

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR IOS

TS105-10L5.5MM Thermopile Sensor

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

15203B 25203B 35203B Uniaxial Biaxia Triaxial

OPERATION MANUAL MODEL 805M1 ACCELEROMETER

OPERATION MANUAL MODEL 3038 ACCELEROMETER

TSEV01S01C10 SPECIFICATIONS

TESS WIRELESS SENSOR TAG DEMO V1.1

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

MINIATURE ELECTRONIC PRESSURE SCANNERS ESP-16HD/32HD/64HD

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

TSYS02S Digital Temperature Sensor

TE Connectivity's AMP NETCONNECT Cable Management

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

TESS WIRELESS SENSOR TAG DEMO V1.1

OPERATION MANUAL MODEL 3255A ACCELEROMETER

DOG2 MEMS SERIES USB INCLINOMETER

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

MEAS PICTAIL PLUS FOR MICROCHIP EXPLORER 16

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Seal Kits for BUDI Enclosures

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

OPERATION MANUAL MODEL mA

Transcription:

High Pressure Sensor SPECIFICATIONS Ranges from 2000 to 7000 bar (30k to 100k psi) Stainless steel pressure port Robust for Fatigue testing For static and dynamic applications Linearity up to ±0.3% F.S. FEATURES M16x1.5 high pressure port Metal / metal screw sealing Integrated Amplifier optional Heavy duty body APPLICATIONS Burst pressure test benches Fatigue test benches Laboratory and research Pressure amplifier equipment The P125 is a high pressure transducer designed for to measure static and dynamic pressure up to 7 000 bar (100 kpsi). The mechanical design and a stainless steel construction allow the sensor to withstand most aggressive liquids and fatigue testing. The sensing element is fitted with a temperature compensated Wheatstone bridge equipped with thin strain gauges. TESS offers amplified analogue versions to obtain 0.5-4.5V, 0-5V and 4-20mA. For miniature with flush diaphragm designs, the model XPM6 can measure up to 1 000 bar (15 kpsi). With many years of experience as a designer and a manufacturer of sensors, TE CONNECTIVITY often works with customers to design or customize sensors for specific uses and testing environments. On request, Instruction documents can be provided to ease the selection and use of our sensors and provide helpful tips. SENSOR SOLUTIONS ///P125_en 06/2017 Page 1

STANDARD RANGES psi Pressure Reference Gauge Combined Linearity & Hysteresis (%FS) 2k 30k ±0.5% 4k 60k ±0.5% 7k 100K ±0.5% TEMPERATURE CHARACTERISTICS Operating Temperature Range (OTR) Compensated Temperature Range (CTR) psi Celcius Farenheit Celcius Farenheit Shift in CTR /50 C Sensitivity Shift in CTR /50 C 2k 30k -20 to 80 C 0 to 170 F 0 to 60 C 32 to 140 F < ±2%FS < ±3% 4k 60k 7k 100K MECANICAL CHARACTERISTICS Pressure limit Tightening Torque psi Without damage Without destruction 2k 30k 1,5x FS 3x FS 30 265 4k 60k 1,5x FS 3x FS 30 265 7k 100K 1,2x FS 2x FS 45 400 Notes 1. Material: Body in stainless steel; housing in aluminium alloy. 2. Protection Index: IP65 with cable gland, IP50 with connector output 3. Electrical Termination: cable gland with Ø5 mm shielded cable with 4 wires, standard length 2.0 m [6.6 ft] N.m lbf.in SENSOR SOLUTIONS ///P125_en 06/2017 Page 2

ELECTRICAL CHARACTERISTICS (All values are typical at temperature 23±3ºC) NON AMPLIFIED VERSION Frequency resonnance Sensitivity Input Impedance Ze Zs 2k 30k TBD 10 Vdc 2 mv/v < ±1mV/V 1500 500 4k 60k TBD 1500 500 7k 1K TBD 1000 500 Note 1. impedance standard, available <100Ω on request AMPLIFIED VERSION A1 Sensitivity 1 Zs 2 All ranges 3 khz 10 to 30 Vdc 4 ±0.2V 0.5 ±0.2V 25 ma 1 000 AMPLIFIED VERSION A2 Full Scale 1 Zs 2 All ranges 3 khz 10 to 30 Vdc 4 ±0.2V 0.5 ±0.2V 25 ma 1 000 AMPLIFIED VERSION A3 4 Full Scale Zs All ranges 3 KHz 10 to 26 Vdc 16 ±0.3mA 4 ±0.3mA Up to 20 ma - Notes 1. Standard output signal, custom outputs available on request. 2. impedance standard, available <100Ω on request. 3. Insulation under 50Vdc 100MΩ 4. A3 current output is a two wires version 5. CE conformance according to EN 61010-1, EN 50081-1, EN 50082-1. SENSOR SOLUTIONS ///P125_en 06/2017 Page 3

DIMENSIONS (METRIC ONLY) SENSOR SOLUTIONS ///P125_en 06/2017 Page 4

OPTIONS SC : Connector output L00M : special cable length, replace 00 with total length in meters ORDERING INFORMATION P125 - A1-2KB G - /L4M Model - Electrical interface - Ranges & unit Pressure Reference - /Options P125 - (empty) = bridge mv/v A1 = 0.5 to 4.5V A2 = 0-5V A3 = 4-20mA - 2KB 4KB 7KB G = Gage - /ETX /SC /L00M The sensor ordering codes uses only bar as units because P125 uses metric threads. value correspondence is noted as information SUPPLIED ACCESSOIRES (ONLY WITH SC OPTION) EFMX-4M : mating plug Jaeger 530-801-006 with clamp 530-841-006 standard with SC option EFMX-4H : mating plug Jaeger 530-804-006 with clamp 530-844-006 for ET1, ET2 or ET3 & SC options NORTH AMERICA Measurement Specialties, Inc., Phone: +1 800 522 6752 Email: customercare.frmt@te.com EUROPE Measurement Specialties (Europe), Ltd. Phone: +31 73 624 6999 Email: customercare.lcsb@te.com ASIA Measurement Specialties (China), Ltd., Phone +86 400 820 6015 Email: customercare.shzn@te.com TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2015 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS ///P125_en 06/2017 Page 5